1、Service Manual DIGITAL MULTITRACKER RadioFans.CN 收音机爱 好者资料库 Read Instructions - All the safety and operating instructions should be read before the appliance is operated. Retain Instructions - The safety and operating instructions should be retained for future reference. Heed Warnings - All warnings

2、 on the appliance and in the operating instructions should be adhered to. Follow Instructions - All operating and use instructions should be followed. Water and Moisture - The appliance should not be used near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basemen

3、t, or near a swimming pool, and the like. Carts and Stands - The appliance should be used only with a cart or stand that is recommended by the manufacturer. 1. 2. 3. 4. 5. 6. or pinched by items placed upon or against them, payingparticular attention to cords at plugs, convenience receptacles, and t

4、he point where they exit from the appliance. Cleaning - The appliance should be cleaned only as recommended by the manufacturer. Nonuse Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time. Object and Liquid Entry - Care should be t

5、aken so that objects do not fall and liquids are not spilled into the enclosure through openings. Damage Requiring Service - The appliance should be serviced by qualified service personnel when: 13. 14. 15. 16. The power supply cord or the plug has been damaged; or Objects have fallen, or liquid has

6、 been spilled into the appliance; or The appliance has been exposed to rain; or The appliance does not appear to operate normally or exhibits a marked change in performance; or The appliance has been dropped, or the enclosure damaged. A. B. C. D. E. Servicing - The user should not attempt to service

7、 the appliance beyond that described in the operating instructions. All other servicing should be referred to qualified service personnel. The appliance should be situated away from drops of water or spray of water. Objects containing liquid such as vase must not be put on the appliance. The applian

8、ce is not completely isolated from the power supply even if the power switch is at off position. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. Only use attachments/accessories specified by the manufacturer

9、. An appliance with a protective earth terminal should be connected to mains outlet with a protective earth connection. An appliance should be placed in a position where an AC plug / inlet can be easily pulled out by hand. Main plug is used as the disconnection device. It shall remain readily operab

10、le and should not be obstructed during intended use. To be completely disconnected the apparatus from supply mains, the main plug of the apparatus shall be disconnected from the mains socket outlet completely. 17. 18. 19. 20. 21. 22. 23. 24. 25. An appliance and cart combination should be moved with

11、 care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn. Wall or Ceiling Mounting - The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer. Ventilation - The appliance should be situated so that its locat

12、ion or position does not interfere with its proper ventilation. For example, the appliance should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or, place in a built-in installation, such as a bookcase or cabinet that may impede the flow of air throu

13、gh the ventilation openings. Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat. Power Sources - The appliance should be connected to a power supply only of the type described in the o

14、perating instructions or as marked on the appliance. Grounding or Polarization - The precautions that should be taken so that the grounding or polarization means of an appliance is not defeated. Power Cord Protection - Power supply cords should be routed so that they are not likely to be walked on 7

15、. 8. 9. 10. 11. 12. WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. SAFETY INSTRUCTIONS CAUTION CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER - SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVI

16、CE PERSONNEL. RISK OF ELECTRIC SHOCK DO NOT OPEN The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric

17、 shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLO

18、T, FULLY INSERT. ATTENTION: POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSSER JUSQU AU FOND. RadioFans.CN 收音机爱 好者资料库 3 & Service Manual Parts marked with this sign are safety critical components. They must always be re

19、placed with identical components. Refer to the Fostex Parts List and ensure exact replacement. CAUTION TABLE OF CONTENTS NOTES * PCB assembly, parts list and circuit diagrams are given in this manual to assist the service technician in maintaining the Model MR16HD and MR16HD/CD. To make it simple, M

20、R16HD and MR16HD/CD are just descried as MR16 hereafter in this manual. If a distinction is required between the two, the model number MR16HD and MR16HD/CD are described. * The following accessories are supplied with MR-16HD, MR-16HD/CD as the standard accessories. Owners manual, MR-16HD, ENG : 8588

21、088000 (452186) Owners manual, MR-16HD, JPN : 8588089000 (452188) Owners manual supplement, MR-16HD, ENG : 8588093000 (456636) Owners manual supplement, MR-16HD/CD, ENG : 8588095000 (456638) Owners manual supplement, MR-16HD, JPN : 8588094000 (456637) Owners manual supplement, MR-16HD/CD, JPN : 8588

22、096000 (456639) * The following is the packing material for MR-16HD/CD. Carton, inner, MR-16HD : 8528101000 (452153) Poly, Form, L, MR-16HD : 8528099000 (452151) Poly, Form, R, MR-16HD : 8528100000 (452152) 1. 2. 3. 4. 5. 6. 7. 8. 4 7 10 16 22 24 49 66 SPECIFICATIONS . . . . . . . . . . . . . . . .

23、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONTROLS, INDICATORS & CONNECTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SOFTWARE UPDATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SERV

24、ICE MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MR16HD & MR16HD/CD PCB CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . EXPLODED VIEW, PCB ASSEMBLY & PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . .

25、CIRCUIT DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ERROR CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RadioFans.CN 收音机爱 好者资料库 4 & Service Manual 1. SPECIFICATIONS SPECIFICA

26、TION UNIT 0 dBV = 1.0 Vrms, 0 dBu = 0.775 Vrms REFERENCE LEVEL 12 dB below full scale level ANALOG IN (A D) Connector XLR-3-31 type (Pin-1: GND, Pin-2: Hot, Pin-3: COLD) / 6 mm TRS phone balanced (Inserting TRS phone jack breaks signal fed to XLR connector.) Input Level - 48 dBu (MIC) + 4 dBu (LINE)

27、 Input Impedance 1.5 k or more 400 k or more (INPUT SW: GTR) Reference Input Level LINE + 4 dBu MIC - 48 dBu Phantom - 48 V, On/Off switchable by MENU setting. Fed to XLR connector only. INSERT (A) Connector 6 mm TRS phone (Tip: output, Ring: Input, Sleeve: GND) Load Impedance 10 k or more Reference

28、 Output Level - 10 dBV Input Impedance 10 k or more Reference Input Level - 10 dBV STEREO OUT (L, R) Connector 6 mm phone Reference Output Level - 10 dBV (Unbalanced) Load Impedance 10 k or more AUX OUT (x 2) Connector 6 mm phone Reference Output Level - 10 dBV (Unbalanced) Load Impedance 10 k or mo

29、re PHONES (x 2) Connector 6 mm STEREO phone Load Impedance 16 or more Maximum Output Level 50 mW or more at 32 MIDI OUT Connector DIN 5-pin Format MIDI Standard FOOT SW Connector 6 mm phone ON/OFF Level TTL Level Type Unlatched type S/P DIF OUT Connector Optical Format IEC60958 (S/P DIF) RadioFans.C

30、N 收音机爱 好者资料库 5 & Service Manual USB Device USB 1.1. USB logo certifi cate not acquired. Connecting a USB key board and a storage device for fi le transfer is possible. Connector A type USB Device USB 2.0 high speed. USB logo certifi cate not acquired. File transfer be tween PC and MR16 is possible.

31、Format B type 1 2 3 4 VBUS D - D + GND DATA 21 34 Record & Playback Medium Internal 3.5” HD Sampling Frequency 44.1 kHz Resolution 16 bits linear File System FAT-32 Number of Track 16 A/D & D/A Converter A/D 24 bits delta-sigma, Cirrus Logic CS5331 D/A 24 bits delta-sigma, Cirrus Logic CS4345 Fader

32、256 steps, 30 mm CD-R/RW Drive Accession No. 0221205 Maximum Output Level ST OUT + 2 dBV 1 dB (full scale level) AUX OUT + 2 dBV 1 dB (full scale level) PHONES 50 mW or more (32 load, 1 kHz) Reference Output Level ST OUT - 10 dBV 4 dB (Fader fi xed at standard position (0 dB), 1 kHz) AUX OUT - 10 dB

33、V 4 dB (Fader fi xed at standard position (0 dB), 1 kHz) Frequency Response ST OUT 20 Hz 20 kHz + 2 dB, - 3 dB (MIC/LINE) AUX OUT 20 Hz 20 kHz + 2 dB, - 3 dB (MIC/LINE) PHONES 50 Hz 15 kHz + 2 dB, - 3 dB (50 mW, 32 load) T.H.D. MIC - ST OUT 0.1 % or less (Full scale level - 2 dB, 1 kHz) LINE - ST OU

34、T 0.1 % or less (Full scale level - 2 dB, 1 kHz) LINE - PHONES 0.1 % or less (50 mW, 32 load, 1 kHz) Dynamic Range 89 dB or more S/N LINE 89 dB or more (IHF A, input terminated by 150 resistor.) MIC 80 dB or more (IHF A, input terminated by 150 resistor.) 1 2 3 4 VBUS D - D + GND DATA 1234 RadioFans

35、.CN 收音机爱 好者资料库 6 & Service Manual Residual Noise LINE - 87 dBV or less (DIN, input terminated by 150 resistor.) MIC - 78 dBV or less (DIN, input terminated by 150 resistor.) PHONES - 85 dBV or less (DIN) Crosstalk 65 dB or more (1 kHz) LINE (TRIM : MIN) 85 dB or more (1 kHz, full scale level is inpu

36、t to adjacent channel.) MIC (TRIM : MAX) 75 dB or more (1 kHz, full scale level is input to adjacent channel.) Click Noise Power On/Off - 20 dBVp-p or less (ST OUT) Others - 30 dBVp-p or less (ST OUT) Phantom Voltage + 48 2 V, On/Off on all channels at once by MENU setting. Dimensions 400 (W) x 85 (

37、H) x 265 (D) mm (including protruding portion) Weight 3.3 kg Power JPN 100 V AC USA 120 V AC EUR/UK 230 V AC Power Consumption 14 W Usage Condition Horizontal, continuous operation Environmental Condition Standard Temperature 20 2 C Standard humidity 65 5 % Characteristics Guaranteed Temperature + 5

38、 C + 40 C Humidity 30 % 70 % Voltage deviation 5 % or less Operation Guaranteed Temperature + 5 C + 45 C Humidity 85 % or less Voltage deviation 10 % or less Vibration & Drop Tests Comply to Fostex Company technical standards Safety Standard IEC60065 Others EMI EN55011 Group 1 Class B EN61000-3-2 &

39、3-3 EMS EN61000-6-1 (Year 2001 version) Environment Response RoHS directive compliance Specifi cations and physical appearance are subject to change without notice for product improvement. RadioFans.CN 收音机爱 好者资料库 7 & Service Manual 2. CONTROLS, INDICATORS & CONNECTORS 1. INPUT A input connectors 2.

40、INSERT connector 3. INPUT B, C, D input connectors 4. STEREO OUT jacks 5. AUX OUT jacks 6. PHONES jacks 7. PHONES VOL control 8. LCD display 9. POWER switch 10. MENU/ENTER rotary / push knob 11. MASTER fader 12. Track faders 13. REC SELECT keys 14. PAN controls 15. EFFECT SEND controls 16. INPUT EQ

41、keys 17. TO STEREO BUSS keys TO STEREO BUSS LEVEL control 18. PEAK indicators 19. DISTORTION control 20. TRIM controls PEAK GUITAR MIN DISTORTION MAXLINEMIC TRIM INSERT/GUITAR UNBAL BALBALBALBAL INPUT AINPUT BINPUT CINPUT D VOLUME MINMAX PEAK LINE TRIM MIC UNBAL POWER UNBAL MIC TRIM LINE PEAK UNBAL

42、MIC TRIM LINE PEAK MAX MIN 1 RL 100SIMULATIONSIMULATION AMPMIC 010 LR 010 LR 23 RL 100 48 010 LR 76 RL 100 RL 100010 LR 5 MAX MIN MASTER REC SELECT RECORDSTOPPLAY REWINDF FWD UNDO/REDOSTORE LOCATE REC ENDLOCATE ABS ZERO A-B PLAY BOUNCE MASTERING BRIGHT 15/16 STEREO WAV FILE NATURALPOWERFUL B / OUTA

43、/ INPLAY MODEAUTO PUNCH LOCATE EFFECT DELAYPLATEHALLROOM BOUNCE MODE CONTRAST TIMEBASE SELECT RHYTHM GUIDEDIRECT LOCATE EFFECT SEND PAN INPUT EQ TO STEREO BUSS LEVEL 9/1011/1213/1415/16 ABC1DEF2GHI3JKL4MNO5YZ9PQR6+-_0STU7VWX8DELETE MENU / ENTER MINMAX MINMAX REVERB / DELAY TIME LSTEREO OUTR 1AUX OUT

44、2 1PHONES2 DYNAMICBRIT STACK CONDENSERUS METAL TUBE60S COMBO INPUT AINPUT BINPUT CINPUT D 123 45 6 78 9 10 1112 13 14 15 16 17 18 19 20 RadioFans.CN 收音机爱 好者资料库 8 & Service Manual 21. REVERB/DELAY TIME control 22. EFFECT keys 23. BOUNCE MODE key 24. 15/16 STEREO WAV FILE key 25. MASTERING keys POWERF

45、UL key NATURAL key BRIGHT key 26. STORE key 27. UNDO/REDO key 28. TIME BASE SEL key 29. DIRECT LOCATE key 30. CONTRAST key 31. RHYTHM GUIDE key 32. Transport keys PLAY key STOP key RECORD key F FWD key REWIND key 33. LOCATE B/OUT key 34. LOCATE A/IN key 35. PLAY MODE key 36. AUTO PUNCH key 37. Inser

46、t effect selection keys PEAK GUITAR MIN DISTORTION MAXLINEMIC TRIM INSERT/GUITAR UNBAL BALBALBALBAL INPUT AINPUT BINPUT CINPUT D VOLUME MINMAX PEAK LINE TRIM MIC UNBAL POWER UNBAL MIC TRIM LINE PEAK UNBAL MIC TRIM LINE PEAK MAX MIN 1 RL 100SIMULATIONSIMULATION AMPMIC 010 LR 010 LR 23 RL 100 48 010 L

47、R 76 RL 100 RL 100010 LR 5 MAX MIN MASTER REC SELECT RECORDSTOPPLAY REWINDF FWD UNDO/REDOSTORE LOCATE REC ENDLOCATE ABS ZERO A-B PLAY BOUNCE MASTERING BRIGHT 15/16 STEREO WAV FILE NATURALPOWERFUL B / OUTA / INPLAY MODEAUTO PUNCH LOCATE EFFECT DELAYPLATEHALLROOM BOUNCE MODE CONTRAST TIMEBASE SELECT R

48、HYTHM GUIDEDIRECT LOCATE EFFECT SEND PAN INPUT EQ TO STEREO BUSS LEVEL 9/1011/1213/1415/16 ABC1DEF2GHI3JKL4MNO5YZ9PQR6+-_0STU7VWX8DELETE MENU / ENTER MINMAX MINMAX REVERB / DELAY TIME LSTEREO OUTR 1AUX OUT2 1PHONES2 DYNAMICBRIT STACK CONDENSERUS METAL TUBE60S COMBO INPUT AINPUT BINPUT CINPUT D 21 22

49、 23 24 25 26 27 28 29 30 31 32 3334353637 RadioFans.CN 收音机爱 好者资料库 9 & Service Manual 1. INPUT A SELECT switch 2. FOOT SW jack 3. DIGITAL OUT connector 4. MIDI OUT jack 5. USB HOST connector 6. USB port 7. AC IN conector 1. Internal CD-R/RW drive USB USB HOSTMIDI OUTDIGITAL OUTFOOT SW INPUT A SEL GTR CLEANMIC/LINE GTR DIST 1

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 功放/音响/收扩 > Fostex

copyright@ 2008-2023 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号