Grundig-UMS4101-mc-sm维修电路原理图.pdf

上传人:cc518 文档编号:103818 上传时间:2020-11-07 格式:PDF 页数:38 大小:8.22MB
下载 相关 举报
Grundig-UMS4101-mc-sm维修电路原理图.pdf_第1页
第1页 / 共38页
Grundig-UMS4101-mc-sm维修电路原理图.pdf_第2页
第2页 / 共38页
Grundig-UMS4101-mc-sm维修电路原理图.pdf_第3页
第3页 / 共38页
亲,该文档总共38页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Grundig-UMS4101-mc-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Grundig-UMS4101-mc-sm维修电路原理图.pdf(38页珍藏版)》请在收音机爱好者资料库上搜索。

1、CIRFLEXX UMS 4100 GLL0150 CIRFLEXX UMS 4101 GLL0350 Zustzlich erforderliche Unterlagen fr den Komplettservice Additionally required Service Documents for the Complete Service Service Manual Grundig Service Hotline Deutschland TV TV SAT VCR/LiveCam HiFi/Audio Car Audio Telekommunikation Fax: Planatro

2、n (8.00-22.00 Uhr) 0180/52318-41 0180/52318-49 0180/52318-48 0180/52318-42 0180/52318-43 0180/52318-44 0180/52318-45 0180/52318-51 0180/52318-99 Mo.-Fr. 8.00-18.00 Uhr Telefon:0180/52318-40 0180/52318-50Fax: Technik: Ersatzteil-Verkauf:Mo.-Fr. 8.00-19.00 Uhr Kundendienst/Werksttten: 0180/52318-52 01

3、80/52318-46 Telefon: Fax: gebhrenpflichtig Mo.-Fr. 8.00-18.00 Uhr Sicherheit Safety Materialnr./Part No. 720108000000 HiFiService Manual Materialnummer/Part Number 720107718000 nderungen vorbehalten/Subject to alteration Printed in Germany W H-S44 0102 8002/8012, 8005/8015, 8006/8016 ? UMS 4101STERE

4、O MICRO HIFI SYSTEM + VOLUME CD TUNER/RADIO TAPE/AUX ON/OFF TAPE MODE RECORD RadioFans.CN 收音机爱 好者资料库 Allgemeiner Teil / General SectionUMS 4100, UMS 4101 1 - 2GRUNDIG Service Es gelten die Vorschriften und Sicherheitshin- weise gem dem Service Manual Sicherheit, Materialnummer 720108000000, sowie zu

5、stz- lich die eventuell abweichenden, landes- spezifischen Vorschriften! The regulations and safety instructions shall be valid as provided by the Safety Service Manual, part number 720108000000, as well as the re- spective national deviations! Table of Contents Page General Section. 1 - 2 1 - 15 Me

6、asuring Instruments / Equipment . 1 - 2 Technical Data . 1 - 3 Service Hints . 1 - 3 Disassembly Instructions . 1 - 4 Operating Hints . 1 - 12 Adjustment Procedures.2 - 3 . 2 - 4 Layout of PCBs and Circuit Diagrams . 3 - 1 3 - 23 Block Diagram. 3 - 1 Wiring Diagram . 3 - 2 Circuit Diagrams: Amplifie

7、r Part. 3 - 6 Tuner Part . 3 - 8 CD and Processor Part . 3 - 14 Cassette Part (only UMS 4101) . 3 - 16 Mains Unit . 3 - 19 Display PCB . 3 - 20 Keyboards UMS 4100 . 3 - 22 Keyboards UMS 4101 . 3 - 23 Layout of the PCBs: Amplifier Part. 3 - 4 Tuner Part . 3 - 10 CD and Processor Part . 3 - 12 Cassett

8、e Part (only UMS 4101) . 3 - 18 Mains Unit . 3 - 19 Display PCB . 3 - 21 Keyboards UMS 4100 . 3 - 22 Keyboards UMS 4101 . 3 - 23 Exploded Views and Spare Parts Lists. 4 - 1 4 - 8 Exploded View UMS 4100 . 4 - 1 Spare Parts List UMS 4100 . 4 - 5 Exploded View UMS 4101 . 4 - 3 Spare Parts List UMS 4101

9、 . 4 - 7 Inhaltsverzeichnis Seite Allgemeiner Teil . 1 - 2 1 - 11 Messgerte / Messmittel . 1 - 2 Technische Daten . 1 - 3 Servicehinweise . 1 - 3 Ausbauhinweise . 1 - 4 Bedienhinweise . 1 - 8 Abgleichvorschriften .2 - 1 . 2 - 2 Platinenabbildungen und Schaltplne . 3 - 1 3 - 23 Blockschaltplan . 3 -

10、1 Verdrahtungsplan. 3 - 2 Schaltplne: Verstrkerteil . 3 - 6 Rundfunkteil . 3 - 8 CD- und Prozessorteil . 3 - 14 Cassettenteil (nur UMS 4101) . 3 - 16 Netzteil . 3 - 19 Display-Platte . 3 - 20 Bedien-Platten UMS 4100. 3 - 22 Bedien-Platten UMS 4101. 3 - 23 Platinenabbildungen: Verstrkerteil . 3 - 4 R

11、undfunkteil . 3 - 10 CD- und Prozessorteil . 3 - 12 Cassettenteil (nur UMS 4101) . 3 - 18 Netzteil . 3 - 19 Display-Platte . 3 - 21 Bedien-Platten UMS 4100. 3 - 22 Bedien-Platten UMS 4101. 3 - 23 Explosionszeichnungen und Ersatzteillisten. 4 - 1 4 - 8 Explosionszeichnung UMS 4100 . 4 - 1 Ersatzteill

12、iste UMS 4100 . 4 - 5 Explosionszeichnung UMS 4101 . 4 - 3 Ersatzteilliste UMS 4101 . 4 - 7 Allgemeiner Teil Messgerte / Messmittel FrequenzzhlerMess-Sender WobbelsenderOszilloskop DigitalvoltmeterKlirrfaktormessgert Testcassette 3150Hz/10kHz (z.B. 448) Beachten Sie bitte das GRUNDIG Messtechnik-Pro

13、gramm, das Sie unter folgender Adresse erhalten: General Section Measuring Instruments / Equipment Frequency counterSignal generator Sweep generatorOscilloscope Digital voltmeterDistortion meter Test cassette 3150Hz/10kHz (e.g. 448) Please note the GRUNDIG Catalog Test and Measuring Equipment obtain

14、able from: GRUNDIG AG Geschftsbereich Instruments Test- und Mess-Systeme Wrzburger Str. 150 D 90766 Frth/Bay Tel. 0911/703-4540 Fax 0911/703-4130 eMail: Internet: http:/www.grundig-instruments.de RadioFans.CN 收音机爱 好者资料库 UMS 4100, UMS 4101Allgemeiner Teil / General Section GRUNDIG Service1 - 3 Servic

15、ehinweise Vor ffnen des Gehuses Netzstecker ziehen. Cassettenteil berprfen Sie vor Beginn der Service-Arbeiten, ob die Magnetkpfe, die Tonwelle und die Gummiandruckrolle frei von Bandabrieb sind. Zum Reinigen dieser Teile verwenden Sie ein mit Spiritus oder Reinigungsbenzin getrnktes Wattestbchen; d

16、adurch verbessert sich der Aufnahme- und Wiedergabepegel, sowie der Bandlauf. Nach dem Ersatz von Magnetkpfen oder sonstiger Bauteile mssen die technischen Daten des Gertes anhand der im Service Manual vorgegebenen Messwerte berprft bzw. eingestellt werden. Leitungsverlegung Bevor Sie die Leitungen

17、und insbesondere die Masseleitungen lsen, muss die Leitungsverlegung zu den einzelnen Baugruppen beachtet werden. Nach erfolgter Reparatur ist es notwendig, die Leitungsfhrung wieder in den werkseitigen Zustand zu versetzen um evtl. sptere Ausflle oder Strungen zu vermeiden. Service Hints Disconnect

18、 the mains plug before opening the set. Cassette Section Before commencing service work, ensure that the magnetic heads, the capstan and the pinch roller are free from particles produced by tape abrasion. The recording and playback levels and the tape run can be improved by cleaning these parts with

19、 a cotton-wool tip soaked in spirit or cleaning benzine. If the heads or other components have been replaced, the technical data of the recorder must be checked or adjusted according to the values specified in the Service Manual. Wiring Before disconnecting any leads and especially the earth connect

20、ing leads observe the way they are routed to the individual assemblies. On completion of the repairs the leads must be laid out as originally fitted at the factory to avoid later failures or disturbances. Technische Daten Verstrkerteil Ausgangsleistung: Sinusleistung. 2 x 12W Musikleistung . 2 x 20W

21、 Eingangsempfindlichkeit/Impedanz . 500mV/22k Empfangsteil Empfangsbereich FM . 87,5 .108,0MHz Empfangsbereich MW. 522 . 1620kHz CD Teil Frequenzgang . 20Hz . 20kHz Geruschspannungsabstand (wtd.) . 90dB Cassettenteil (nur UMS 4101) Tontrger . Compact-Cassette nach DIN 45516 (IECI) Frequenzbereich .

22、40Hz . 14,0kHz Spurlage.Viertelspur international Geruschspannungsabstand (wtd.) . 55dB Gleichlaufschwankungen (WRMS) . 0,15% Spannungsversorgung Betriebsspannung . 230V Netzfrequenz. 50/60Hz max. Leistungsaufnahme . 75W Leistungsaufnahme in Standby. 90dB Cassette unit (UMS 4101 only) Sound recordin

23、g medium . Compact tape according to DIN 45516 (IECI) Frequency range . 40Hz . 14.0kHz Tracking position . International quarter-track Noise voltage ratio (wtd.) . 55dB Wow and flutter (WRMS) . 0.15% Power supply Operating voltage. 230V Mains frequency. 50/60Hz Max. power consumption . 75W Power con

24、sumption in stand-by mode . 60dBV; Oszilloskop an Messpunkt TP5, IC502(-19). AM, 1620kHz; Digital-Voltmeter an Messpunkt TP3. AM; Mess-Sender ber Loop-Antennen ankoppeln; Ue 50dBV; fmod = 1kHz; Oszilloskop an Lautsprecher-Ausgang. FM, 98.0MHz; Mess-Sender an FM-Antennen-Eingang; Ue = 20dBV; fmod = 1

25、kHz; Hub = 75kHz; Klirrfaktormessgert an Lautsprecher-Ausgnge. FM; Mess-Sender an FM-Antennen-Eingang; Ue = 50dBV; fmod = 19kHz; Oszilloskop an Lautsprecher-Ausgnge. Mit T503 auf Maximum abgleichen. Mit T501 auf 8,0V 0,2V abgleichen. Wechselweise mit L502 bei 558kHz und mit VC501 bei 1440kHz auf NF-

26、Maximum abgleichen. Mit ZF-Filter A (unter dem Deckel) auf Klirrfaktor-Mini- mum abgleichen. Mit LPF501 (linker Kanal) und mit LPF502 (rechter Kanal) auf NF-Minimum abgleichen. CD Messgerte: Digital-Voltmeter AbgleichVorbereitung Abgleichvorgang DC-OffsetBetriebsart CD; Digital-Voltmeter zwischen TP

27、9 und TP10 Mit VR701 auf 0V 0,1V abgleichen. Cassette (nur UMS 4101) Messgerte: Frequenzzhler, Oszilloskop, Test-Cassette 3150Hz/10kHz (z.B. 448) AbgleichVorbereitung Abgleichvorgang 1. Lsch-Oszillator 2. Azimut 3. Band- geschwindigkeit Frequenzzhler an CN401A (-2). Leer-Cassette einlegen und Aufnah

28、me starten. Oszilloskop an Lautsprecher-Ausgang. Test-Cassette einlegen und 10kHz-Teil abspielen. Frequenzzhler an Lautsprecher-Ausgang. Test-Cassette einlegen und 3150Hz-Teil abspielen. Mit L401 auf 62kHz 0,5kHz abgleichen. Bei “ 2 “ mit Kopfschraube a auf maximalen und gleichen Pegel auf beiden Ka

29、nlen abgleichen. Bei “ 1 “ mit Kopfschraube b auf maximalen und gleichen Pegel auf beiden Kanlen abgleichen. Mit dem Einstellregler (im Cass.-Motor) auf 3150Hz 10Hz einstellen. Bandgeschwindigkeit Tape Speed ab RadioFans.CN 收音机爱 好者资料库 UMS 4100, UMS 4101Abgleichvorschriften / Adjustment Procedures GR

30、UNDIG Service2 - 2 Abgleichlageplne RadioFans.CN 收音机爱 好者资料库 Abgleichvorschriften / Adjustment ProceduresUMS 4100, UMS 4101 2 - 3GRUNDIG Service Adjustment Procedures Tuner Test equipment: Sweep / Signal Generator, Distortion Meter, Oscilloscope, Digital Voltmeter Note: The frontend is a completely p

31、readjusted module. Only the IF filter must be adjusted to the IF amplifier (Adjustment 4). The values of the tuning voltages are as follows: 87.5MHz = typ. 1,6V; 108MHz = typ. 8.0V. AdjustmentPreparation Adjustment Procedure 1. AM IF 2. AM Oscillator 3. AM Band Pass 4. FM IF 5. 19kHz Filter AM; Swee

32、p Generator 450kHz to AM Aerial Input; Ue 60dBV; Oscilloscope to Testpoint TP5, IC502(-19). AM, 1620kHz; Digital Voltmeter to Testpoint TP3. AM; Couple Signal Generator via Loop Antennas; Ue 50dBV; fmod = 1kHz; Oscilloscope to Loudspeaker Output. FM, 98.0MHz Signal Generator to FM Aerial Input; Ue =

33、 20dBV; fmod = 1kHz; Deviation = 75kHz; Distortion Meter to Loudspeaker Outputs. FM; Signal Generator to FM Aerial Input; Ue = 50dBV; fmod = 19kHz; Oscilloscope to Loudspeaker Outputs. Adjust with T503 for Maximum. Adjust with T501 for 8.0V 0.2V. Adjust alternating with L502 at 558kHz and with VC501 at 1440kHz for AF Maximum. Adjust with IF Filter A (under the cover) for Distortion Minimum. Adjust with LPF501 (left channel) and with LPF502 (right channel) for AF Minimum. CD Test equi

展开阅读全文