1、TK No.9101E SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT DVD PLAYER SERVICE MANUAL 2001FebruaryDigital Media Products Division, Tokai DV-P315U DV-P313U 1. Precautions 2. Reference Information 3. Product Specification 4. Operating Instructions 5. Disassembly and Reassembly 6. Circui

2、t Descriptions 7. Troubleshooting 8. Exploded Views 9. Replacement Parts List 10. Block Diagram 11. PCB Diagrams 12. Wiring Diagram 13. Schematic Diagrams CONTENTS POWER/STANDBY RadioFans.CN 收音机爱 好者资料库 updated 11/19/02 Precautions 1-1 1. Precautions 1-1 Safety Precautions 1) Before returning an inst

3、rument to the customer, always make a safety check of the entire instrument, including, but not limited to, the following items: (1) Be sure that no built-in protective devices are defective or have been defeated during servicing. (1)Protective shields are provided to protect both the technician and

4、 the customer. Correctly replace all missing protective shields, including any remove for servicing convenience. (2)When reinstalling the chassis and/or other as- sembly in the cabinet, be sure to put back in place all protective devices, including, but not limited to, nonmetallic control knobs, ins

5、ulating fish papers, adjustment and compartment covers/shields, and isolation resistor/capacitor networks. Do not operate this instrument or permit it to be operated without all protective devices correctly installed and functioning. (2) Be sure that there are no cabinet openings through which adult

6、s or children might be able to insert their fingers and contact a hazardous voltage. Such openings include, but are not limited to, excessively wide cabinet ventilation slots, and an improperly fitted and/or incorrectly secured cabinet back cover. (3) Leakage Current Hot Check-With the instrument co

7、mpletely reassembled, plug the AC line cord directly into a 120V AC outlet. (Do not use a isolation transformer during this test.) Use a leakage current tester or a metering system that complies with American National Standards institute (ANSI) C101.1 Leakage Current for Appliances and Underwriters

8、Laboratories (UL) 1270 (40.7). With the instruments AC switch first in the ON position and then in the OFF position, measure from a known earth ground (metal water pipe, conduit, etc.) to all exposed metal parts of the instrument (antennas, handle brackets, metal cabinets, screwheads, metallic overl

9、ays, control shafts, etc.), especially any exposed metal parts that offer an electrical return path to the chassis. Any current measured must not exceed 0.5mA. Reverse the instrument power cord plug in the outlet and repeat the test. See Fig. 1-1. Any measurements not within the limits specified her

10、ein indicate a potential shock hazard that must be eliminated before returning the instrument to the customer. Fig. 1-1 AC Leakage Test (4) Insulation Resistance Test Cold Check-(1) Unplug the power supply cord and connect a jumper wire between the two prongs of the plug. (2) Turn on the power switc

11、h of the instrument. (3) Measure the resistance with an ohmmeter between the jumpered AC plug and all exposed metallic cabinet parts on the instrument, such as screwheads, antenna, control shafts, handle brackets, etc. When an exposed metallic part has a return path to the chassis, the reading shoul

12、d be between 1 and 5.2 megohm. When there is no return path to the chassis, the reading must be infinite. If the reading is not within the limits specified, there is the possibility of a shock hazard, and the instrument must be re-pared and rechecked before it is returned to the customer. See Fig. 1

13、-2. Fig. 1-2 Insulation Resistance Test DEVICE UNDER TEST (READING SHOULD NOT BE ABOVE 0.5mA) LEAKAGE CURRENT TESTER EARTH GROUND TEST ALL EXPOSED METER SURFACES ALSO TEST WITH PLUG REVERSED (USING AC ADAPTER PLUG AS REQUIRED) 2-WIRE CORD Antenna Terminal Exposed Melal Part ohm ohmmeter RadioFans.CN

14、 收音机爱 好者资料库 Precautions 1-2 2) Read and comply with all caution and safety re- lated notes non or inside the cabinet, or on the chassis. 3) Design Alteration Warning-Do not alter of add to the mechanical or electrical design of this instrument. Design alterations and additions, including but not lim

15、ited to, circuit modifications and the addition of items such as auxiliary audio output connections, might alter the safety characteristics of this instrument and create a hazard to the user. Any design alterations or additions will make you, the service, responsible for personal injury or property

16、damage resulting therefrom. 4) Observe original lead dress. Take extra care to assure correct lead dress in the following areas: (1) near sharp edges, (2) near thermally hot parts (be sure that leads and components do not touch thermally hot parts), (3) the AC supply, (4) high voltage, and (5) anten

17、na wiring. Always inspect in all areas for pinched, out-of-place, or frayed wiring, Do not change spacing between a component and the printed-circuit board. Check the AC power cord for damage. 5) Components, parts, and/or wiring that appear to have overheated or that are otherwise damaged should be

18、replaced with components, parts and/ or wiring that meet original specifications. Additionally, determine the cause of overheating and/or damage and, if necessary, take corrective action to remove any potential safety hazard. 6) Product Safety Notice-Some electrical and mechanical parts have special

19、 safety-related characteristics which are often not evident from visual inspection, nor can the protection they give necessarily be obtained by replacing them with components rated for higher voltage, wattage, etc. Parts that have special safety characteristics are identified by shading, an ( )or a

20、( )on schematics and parts lists. Use of a substitute replacement that does not have the same safety characteristics as the recommended replacement part might created shock, fire and/or other hazards. Product safety is under review continuously and new instructions are issued whenever appropriate. P

21、recautions 1-3 1-2 Servicing Precautions CAUTION : Before servicing Instruments covered by this service manual and its supplements, read and follow the Safety Precautions section of this manual. Note : If unforseen circument create conflict between the following servicing precautions and any of the

22、safety precautions, always follow the safety precautions. Remember: Safety First. 1-2-1 General Servicing Precautions (1) a. Always unplug the instruments AC power cord from the AC power source before (1) re-moving or reinstalling any component, circuit board, module or any other instrument assembly

23、, (2) disconnecting any instrument electrical plug or other electrical connection, (3) connecting a test substitute in parallel with an electrolytic capacitor in the instrument. b. Do not defeat any plug/socket B+ voltage interlocks with which instruments covered by this service manual might be equi

24、pped. c. Do not apply AC power to this instrument and /or any of its electrical assemblies unless all solid-state device heat sinks are correctly in- stalled. d. Always connect a test instruments ground lead to the instrument chassis ground before connecting the test instrument positive lead. Always

25、 remove the test instrument ground lead last. Note : Refer to the Safety Precautions section ground lead last. (2) The service precautions are indicated or printed on the cabinet, chassis or components. When servicing, follow the printed or indicated service precautions and service materials. (3) Th

26、e components used in the unit have a specified flame resistance and dielectric strength. When replacing components, use components which have the same ratings. Components i- entified by shading, by( ) or by ( ) in the circuit diagram are important for safety or for the characteristics of the unit. A

27、lways replace them with the exact replacement components. (4) An insulation tube or tape is sometimes used and some components are raised above the printed wiring board for safety. The internal wiring is sometimes clamped to prevent contact with heating components. Install such elements as they were

28、. (5) After servicing, always check that the removed screws, components, and wiring have been in- stalled correctly and that the portion around the serviced part has not been damaged and so on. Further, check the insulation between the blades of the attachment plug and accessible conductive parts. 1

29、-2-2 Insulation Checking Procedure Disconnect the attachment plug from the AC outlet and turn the power ON. Connect the insulation resi- stance meter (500V) to the blades of the attachment plug. The insulation resistance between each blade of the attachment plug and accessible conductive parts(see n

30、ote) should be more than 1 Megohm. Note : Accessible conductive parts include metal panels, input terminals, earphone jacks, etc. Precautions 1-4 1-3 ESD Precautions Electrostatically Sensitive Devices (ESD) Some semiconductor (solid state) devices can be damaged easily by static electricity. Such c

31、omponents commonly are called Electrostati- cally Sensitive Devices(ESD). Examples of typical ESD devices are integrated circuits and some field- effect transistors and semiconductor chip components. The following techniques should be used to help reduce the incidence of component damage caused by s

32、tatic electricity. (1) Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging wrist strap device, which should be

33、 removed for potential shock reasons prior to applying power to the unit under test. (2) After removing an electrical assembly equipped with ESD devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly. (3) Use onl

34、y a grounded-tip soldering iron to solder or unsolder ESD devices. (4) Use only an anti-static solder removal devices. Some solder removal devices not classified as anti-static can generate electrical charges sufficient to damage ESD devices. (5) Do not use freon-propelled chemicals. These can gener

35、ate electrical charges sufficient to damage ESD devices. (6) Do not remove a replacement ESD device from its protective package until immediately before your are ready to install it.(Most replacement ESD devices are packaged with leads electrically shorted together by conductive foam, aluminum foil

36、or comparable conductive materials). (7) Immediately before removing the protective ma- terials from the leads of a replacement ESD device, touch the protective material to the chassis or circuit assembly into which the device will be installed. CAUTION : Be sure no power is applied to the ch- assis

37、 or circuit, and observe all other safety precautions. (8) Minimize bodily motions when handling unpackaged replacement ESD devices. (Otherwise harmless motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity suffi

38、cient to damage an ESD device). Precautions 1-5 1-4 Handling the optical pick-up The laser diode in the optical pick up may suffer electrostatic breakdown because of potential static electricity from clothing and your body. The following method is recommended. (1) Place a conductive sheet on the wor

39、k bench (The black sheet used for wrapping repair parts.) (2) Place the set on the conductive sheet so that the chassis is grounded to the sheet. (3) Place your hands on the conductive sheet(This gives them the same ground as the sheet.) (4) Remove the optical pick up block (5) Perform work on top o

40、f the conductive sheet. Be careful not to let your clothes or any other static sources to touch the unit. Be sure to put on a wrist strap grounded to the sheet. Be sure to lay a conductive sheet made of copper etc. Which is grounded to the table. Fig.1-3 (6) Short the short terminal on the PCB, whic

41、h is in- side the Pick-Up ASSY, before replacing the Pick- Up. (The short terminal is shorted when the Pick- Up Assy is being lifted or moved.) (7) After replacing the Pick-up, open the short terminal on the PCB. THE UNIT WRIST-STRAP FOR GROUNDING 1M 1M CONDUCTIVE SHEET Precautions 1-6 1-5-1 Disasse

42、mbly 1) Remove the power code. 2) Disassemble the Deck-Assy. 3) Solder land 2 points short on Pick-up. (See Fig. 1- 4) 4) Disassembly the Pick-up. 1-5-2 Assembly 1) Replace the Pick-up. 2) Remove the soldering 2 points on Pick-up. 3) Reassemble the Deck-Assy. DECK-ASSY SOLDER LAND 2 POINTS SHORT Not

43、e : If the assembly and disassembly are not done in correct sequence, the Pick-up may be damaged. Fig. 1-4 1-5 Pick-up disassembly and reassembly 3-1 3. Product Specifications Power RequirementsAC 120V, 60Hz Power Consumption15W GENERAL Weight2.7kg DimensionsW 430mm X D 240mm X H 79mm Operating Temp

44、erature Range+5C +35C Operating Humidity Range10% to 75% DVDReading Speed : 3.49 m/s (Digital Versatile Disc)Approx. Play Time (Single Sided, Single Layer Disc) : 135 min. CD : 12CmReading Speed : 1.2 to 1.4 m/s DISC (Compact Disc)Maximum Play Time : 74min. CD : 8CmReading Speed : 1.2 to 1.4 m/s (Co

45、mpact Disc)Maximum Play Time : 20min. VCD : 12Cm Reading Speed : 1.2 to 1.4 m/s Maximum Play Time : 74min. (Video + Audio) Composite Video1 channel : 1.0Vp-p (75ohm load) Y : 1.0Vp-p (75ohm load) Video Output Component VideoPr : 0.70Vp-p (75ohm load) Pb : 0.70Vp-p (75ohm load) S-Video Luminance Sign

46、al : 1Vp-p (75ohm load) Chrominance Signal : 0.286Vp-p (75ohm load) 2 ChannelL (1/L), R (2/R) Audio Output * Frequency Response 48kHz Sampling : 4Hz to 22kHz 96kHz Sampling : 4Hz to 44kHz * S/N Ratio110dB * Dynamic Range100dB * Total Harmonic Distortion0.004% * : Nominal specification Product Specif

47、ication 3-2 MEMO 4-1 4. Operating Instructions 14 POWER/STANDBY When the unit is first plugged in, the indicator lights. When POWER/STANDBYis pressed, the lamp goes out and the player is turned on. DISC TRAY Press OPEN/CLOSE to open and close the disc tray. DISPLA Y Operation indicators are displaye

48、d here. OPEN/CLOSE Press to open and close the disc tray. (PLA Y/PAUSE) Begin or pause disc play. (STOP) Stops disc play. (SKIP/SEARCH) Use to skip a scene or music. If this button is held down for approx. two seconds, it will switch to the search button: Thereafter, each time the button is pressed,

49、 the search speed will switch to 2X, 4X, 8X, 16X, 32X, 128X, after which SKIP will be restored. Description-Front Panel Front Panel Controls POWER/STANDBY 15 You can now select different viewing points of the scene recorded by different cameras (Multi Angle). Disc type indicators Reverse playback / Pause / Forward playback Lights when 3D sound is turned on. DVD : Title number DVD : Chapter number. Video/Audio CD : Track number Repeat play mode Linear PCM audio output Dolby Digital audio output DTS (Digital Theater System) audio output(Digital only) MPEG-2 Aud