Grundig3301 维修电路图、原理图.pdf

上传人:cc518 文档编号:108921 上传时间:2024-07-20 格式:PDF 页数:30 大小:1.76MB
下载 相关 举报
Grundig3301 维修电路图、原理图.pdf_第1页
第1页 / 共30页
Grundig3301 维修电路图、原理图.pdf_第2页
第2页 / 共30页
Grundig3301 维修电路图、原理图.pdf_第3页
第3页 / 共30页
亲,该文档总共30页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Grundig3301 维修电路图、原理图.pdf》由会员分享,可在线阅读,更多相关《Grundig3301 维修电路图、原理图.pdf(30页珍藏版)》请在收音机爱好者资料库上搜索。

1、Zustzlich erforderliche Unterlagen fr den Komplettservice Additionally required Documents for the Complete Service Service Manual Dieses Service Manual ist nur in Datenform verfgbar This Service Manual is only available as data nderungen vorbehalten Subject to alteration Made by GRUNDIG in Germany E

2、-BS360999 Sicherheit Safety Materialnr./Part No. 72010 800 0000 GB Table of Contents Page Adjustment Procedures. 3 5 Circuit Diagrams and Layout of PCBs . 6 26 Circuit Diagrams RF Part . 6 Processor Part . 10 Cassette Part . 14 AF Part. 16 Connection Board . 20 Layout of PCBs . 22 Spare Parts Lists

3、and Exploded View. 27 30 Spare Parts List and Exploded View Tape Drive . 27 Spare Parts List 3301 . 29 D Inhaltsverzeichnis Seite Abgleichvorschriften . 2 5 Schaltplne und Druckplattenabbildungen. 6 26 Schaltplne HF-Teil . 6 Prozessor-Teil. 10 Cassetten-Teil. 14 NF-Teil . 16 Anschluplatte . 20 Druck

4、plattenabbildungen . 22 Ersatzteillisten und Explosionszeichnung . 27 30 Ersatzteilliste und Explosionszeichnung Laufwerk . 27 Ersatzteilliste 3301 . 29 Service-Management Service Manual 3301(G.HK 45-00) Abgleichvorschriften / Adjustment Procedures 2GRUNDIG Service SEAT 3301 D Abgleichvorschriften 1

5、. Hauptplatte Megerte: DC-Voltmeter, Mesender, NF-Voltmeter, Stereocoder Nach Reparaturen am HF- oder ZF-Teil ist der Feldstrke-Offsetabgleich (Pkt. 8) unbedingt durchzufhren. 1. Oszillator (AM und FM) 2. AM-ZF 3. FM-Vorkreis 4. FM-Zwischenkreis 5. FM-ZF 6. FM-Demodulator 7. Gleitender Mono- Stereo

6、bergang 8. Feldstrke-Offset- Spannung AbgleichVorbereitung Abgleichvorgang FM; DC-Voltmeter an FMP16. Mesender an Antenneneingang; LW; Frequenz 153kHz; ohne Modulation; E = 50V (34dBV). DC-Voltmeter an FMP108. Mesender an Antenneneingang; Frequenz 88,0MHz; ohne Modulation; E = 3V (10dBV); DC-Voltmet

7、er an FMP108. Mesender an Antenneneingang; Frequenz 88,0MHz; ohne Modulation; E = 3V (10dBV); DC-Voltmeter an FMP108. Mesender an Antenneneingang; Frequenz 88,0MHz; ohne Modulation; E = 3V (10dBV); DC-Voltmeter an FMP108. Mesender an Antenneneingang; Frequenz 88,0MHz; fmod= 1kHz; Hub = 22,5kHz; E =

8、2V (6dBV); NF-Voltmeter an Lautsprecher-Ausgang. Mesender mit Stereocoder an Antenneneingang; Fre- quenz 88,0MHz; fmod= 1kHz; Hub = 22,5kHz; Pilothub = 7,5 kHz; E = 100V (40dBV); NF-Voltmeter an Lautsprecher-Ausgang. DC-Voltmeter an FMP108. AM: Mesender an Antenneneingang; Frequenz 1008kHz; ohne Mod

9、ulation; E = 16V (24dBV); FM: Mesender an Antenneneingang; Frequenz 95,0MHz; ohne Modulation; E = 7V (17dBV); Gerte-Parameter aufrufen: Gert auschalten. Die Taste RADIO gedrckt halten und das Gert einschalten. Taste RADIO erst loslassen nach- dem 1 Signalton zu hren war (ca. 5 Sekunden). Taste RADIO

10、 erneut so lange drcken bis 2 Signaltne zu hren waren (ca. 7 Sekunden). Taste TP so lange drcken bis 1 Signalton zu hren war (ca. 1 Sekunde). AM: Mit den Tasten r TUNING t den Parametersatz 00 anwhlen 00 1700 . Den Wert UAM (hier z.B. 1700) notieren. FM: Mit den Tasten r TUNING t den Parametersatz 0

11、2 anwhlen 02 1640 . Den Wert UFM (hier z.B. 1640) notieren. Berechnung des Offset-Wertes W: AM: UOffs = UAM - UFS (in Millivolt) FM: UOffs = UFM - UFS (in Millivolt) Ist UOffs negativ: W = 256 + (siehe Beispiel 1); ist UOffs positiv: W = (siehe Beispiel 2). UOffs 20 UOffs 20 Wechselweise mit L06 bei

12、 87,5MHz auf 2,0V20mV und mit C29 bei 108MHz auf 6,0V 100mV abgleichen. Mit F603A auf maximale Spannung abgleichen. Mit L02 auf maximale Spannung abgleichen. Mit L04 auf maximale Spannung abgleichen. Mit F101 auf maximale Spannung abgleichen. Mit F106 auf NF-Maximum abgleichen. Linken Kanal modulier

13、en und mit R206 auf 6dB ber- sprechdmpfung im rechten Kanal einstellen. Spannung (UFS) messen und notieren (in Millivolt). Beispiel 1: UAM = 1700; Gemessene Spannung UFS = 1842mV; UOffs = UAM - UFS = 1700 - 1842mV = -142mV. Da UOffs negativ: W = 256 + = 256 + W = 256 + (-7) = 249 Beispiel 2: UFM = 1

14、640; Gemessene Spannung UFS = 1220mV; UOffs = UFM - UFS = 1640 - 1220mV = 420mV. Da UOffs positiv: W = = = 21 AM: Mit den Tasten r TUNING t den Parametersatz 50 anwhlen 50 174 . Taste TP kurz drcken. Mit den Tasten r TUNING t jetzt den errechneten Wert W einstellen (z.B. W = 249: 50 249 ). Taste TP

15、erneut kurz drcken. FM: Mit den Tasten r TUNING t den Parametersatz 51 anwhlen 51 14 . Taste TP kurz drcken. Mit den Tasten r TUNING t jetzt den errechneten Wert W einstellen (z.B. W = 21: 51 21 ). Taste TP erneut kurz drcken. UOffs 20 -142 20 UOffs 20 420 20 SEAT 3301Abgleichvorschriften / Adjustme

16、nt Procedures GRUNDIG Service3 AbgleichlageplanAlignment Layout ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? EMK Rg 50 Kabel 50 37.555 15pF 150 ? ? ? 37.5 60pF E E= EMK - 26dB AM ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? EMK Rg 50 Kabel 50 1045 10nF 60 75 E E= EMK - 6dB FM Zum Abgleich die Antennenna

17、chbildungen fr AM bzw. FM verwenden. For adjustment use the aerial dummies for AM resp. FM. (09) /2L 442.00 19353- FMP16 FMP108 R206 1 2 15 IC1601 1 2 15 IC1602E L06 L04 L02 SCH1007 51 62 BU1102 R07 SCH1001SCH1002 SCH1006 SCH1005 SCH1004 SCH1003 L602A 1 4 BU1000 51 62 BU1101 R819 Q201 F603A 1 5 F604

18、A F103 F104 F102 Q801 Q701 F106 F101C29 19353-442.00(05)/4B Abgleichvorschriften / Adjustment Procedures 4GRUNDIG Service SEAT 3301 GB Adjustment Procedures 1. Main Board Test equipment: DC Voltmeter, Test Generator, AF Voltmeter, Stereo Coder After repairing the RF or IF Part the adjustment of Sign

19、al Level Offset (para 8) must be done. 1. Oscillator (AM and FM) 2. AM IF 3. FM Pre Stage 4. FM Band Pass 5. FM IF 6. FM Demodulator 7. Sliding Stereo Mono Transition 8. Signal Level Offset AdjustmentPreparation Adjustment Procedure FM; Connect a DC Voltmeter to FMP16. Connect a Test Generator to ae

20、rial input; LW; Frequency 153 kHz; no modulation; E = 50V (34dBV). Connect a DC Voltmeter to FMP108. Connect a Test Generator to aerial input; Frequency 88.0MHz; no modulation; E = 3V (10dBV). Connect a DC Voltmeter to FMP108. Connect a Test Generator to aerial input; Frequency 88.0MHz; no modulatio

21、n; E = 3V (10dBV). Connect a DC Voltmeter to FMP108. Connect a Test Generator to aerial input; Frequency 88.0MHz; no modulation; E = 3V (10dBV). Connect a DC Voltmeter to FMP108. Connect a Test Generator to aerial input; Frequency 88.0MHz; fmod= 1kHz; dev. = 22,5kHz; E = 2V (6dBV); Connect an AF Vol

22、tmeter to Loudspeaker Output. Connect Test Generator with Stereo Coder to aerial input; Frequency: 88.0MHz; E = 100V (40dBV); fmod : 1kHz; dev. 22.5kHz; Pilot dev. 7.5kHz. Connect an AF Voltmeter to Loudspeaker Output. Connect a DC Voltmeter to FMP108. AM: Connect a Test Generator to aerial input; F

23、requency 1008kHz; no modulation; E = 16V (24dBV); FM: Connect a Test Generator to aerial input; Frequency 95.0MHz; no modulation; E = 7V (17dBV); Calling up parameter sets: Switch off the unit. Hold button RADIO depressed and switch on the unit. Release button RADIO only after 1 peep was heard (abt.

24、 5 seconds). Press button RADIO again, until 2 peeps could be heard (abt. 7 seconds). Press button TP until 1 peep could be heard (abt. 1 second). AM: With buttons r TUNING t select parameter 00: e.g. 00 1700 . Note the value UAM (here e.g. 1700). FM: With buttons r TUNING t select parameter 02: e.g

25、. 02 1640 . Note the value UFM (here e.g. 1640). Calculating the Offset Value W: AM: UOffs = UAM - UFS (in millivolts) FM: UOffs = UFM - UFS (in millivolts) If UOffs is negativ: W = 256 + (see example 1); if UOffs is positiv: W = (see example 2). UOffs 20 UOffs 20 Align alternating with L06 at 87.5M

26、Hz for 2.0V20mV and with C29 at 108MHz for 6.0V 100mV. Align with F603A for maximum Voltage. Align with L02 for maximum Voltage. Align with L04 for maximum Voltage. Align with F101 for maximum Voltage. Align with F106 for maximum AF Voltage. Modulate left channel and adjust with R206 for 6dB cross-

27、talk attenuation in the right channel. Measure Voltage (UFS in millivolts) and note it. Example 1: UAM = 1700; Measured Voltage UFS = 1842mV; UOffs = UAM - UFS = 1700 - 1842mV = -142mV. As UOffs is negativ: W = 256 + = 256 + W = 256 + (-7) = 249 Example 2: UFM = 1640; Measured Voltage UFS = 1220mV;

28、UOffs = UFM - UFS = 1640 - 1220mV = 420mV. As UOffs is positiv: W = = = 21 AM: With buttons r TUNING t select parameter 50: e.g. 50 174 . Briefly press button TP. With buttons r TUNING t now set the calculated value (e.g. W = 249: 50 249 ). Briefly press button TP again. FM: With buttons r TUNING t

29、select parameter 51: e.g. 51 14 . Briefly press button TP. With buttons r TUNING t now set the calculated value (e.g. W = 21: 51 21 ). Briefly press button TP again. UOffs 20 -142 20 UOffs 20 420 20 SEAT 3301Abgleichvorschriften / Adjustment Procedures GRUNDIG Service5 AbgleichVorbereitung Abgleichv

30、organg 1. Bandgeschwindig- keit 2. Azimut Frequenzzhler an Lautsprecher-Ausgang anschlieen. Test Cassette 448A (3150Hz-Teil) abspielen. NF-Voltmeter an Lautsprecher-Ausgang anschlieen. Test Cassette 448A abspielen (10kHz-Teil). Mit Motorpoti auf 3150Hz einstellen. Motorpoti In Laufrichtung TAPE A mi

31、t beiden Schrauben A (bzw. in Laufrichtung TAPE B mit beiden Schrauben B) auf maximalen und mglichst gleichen Pegel auf beiden Kanlen einstellen. D 2. Cassettenlaufwerk Megerte: NF-Voltmeter, Frequenzzhler, Test-Cassette 3150Hz (z.B. 448A) AdjustmentPreparation Adjustment Procedure 1. Tape Speed 2.

32、Azimuth Connect Frequency Counter to Loudspeaker Output. Play Test Cassette 448A (3150Hz part). Connect AF Voltmeter to Loudspeaker Outputs. Play Test Cassette 448A (10kHz part). With Motorpoti adjust for 3150Hz. Motorpoti In direction TAPE A adjust both screws A (resp. in direction TAPE B with scre

33、ws B) for maximal and equal level on both channels. GB 2. Cassette Drive Test equipment: AF Voltmeter, Frequency Counter, Test Cassette 3150Hz (e.g. 448A) B AA B B AA B Schaltplne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs 6GRUNDIG Service SEAT 3301 Schaltplne und Druckplatten

34、abbildungen / Circuit Diagrams and Layout of PCBs HF-Teil / RF Part FMP601 BU01 D SG BF543 CT01 BB914 CD01 100K CR04 330K CR606A 1 2 3 4 678 F101 + 22U/16V C606A 10R CR11 820R CR13 AM- (10.7M) AM-IF IN AM-FM-IF FM-IF OUT SEL 8/10 AM-IN AM-IF OUT AM-IF OUT FM-IF OUT FM-IF OUT GND-RF +VS-RF IN 333 32

35、31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 161 1SV172 CD02 22R CR111 15P CC09 47K CR06 K 1N C604A 100N CC615A 1N0 CC14 1M0 CR01 1N0 CC12 R601A 10R 1N0 CC11 3R9 CR12 47N CC34 22N CC102A R14 10R 270R CR103 47K CR02 120R CR102 3 2 1 F102 22N CC33 1 2 34 L02 FMP602 22N CC103A CC32A 3 2 1 F103 100N CC6

36、11 Z47 CD601A 3 2 1 F104 CC22 2UH2 CL03 10P CC04 3N3 CC03 470P CC612A 330R CR104 100R CR03 3P3 CC02 K 33P C01 R07 100R 1 2 3 78 L602A GS D J310 CT602A 22N CC101 BC849C CT601A 100R CR607A 47N CC607A 3U3 L604A + U47/50V C609 10N CC608A 270UH L607A 120UH L606A 3MH3 L603A 15P CC603A 47P CC602A 100N CC60

37、1A 1K5 CR602A 10UH L601A FMP01 6P8 CC17 6P8 CC16 BB914 CD03 10P CC06 8P2 CC08 8P2 CC07 1 2 34 L04 603 CR604A 100R 603 CR605A 0R +S C D ABGLEICHPUNKTE MESSPUNKTE 8V6 8V3 8V3 0V2 1V6 0V9 6V1 0V 0V 0V 6V7 8V6 8V1 AM-Vorstufe FM PRE STAGE FM-VORSTUFE SEAT 3301Schaltplne und Druckplattenabbildungen / Cir

38、cuit Diagrams and Layout of PCBs GRUNDIG Service7 22K CR09 1 2 34 L06 BB914 CD04 2P5-6P C29 FMP617 FMP109 FMP108 6N8 CC203 FMP217 FMP200 FMP202 TUA4300 VREF/RF AM-IF OUT 0.7M) M-IF IN M-FM-IF FM-IF OUT FOSC /8/10 SEL 8/10 PATH MULTI AM-/FM-SWNF-LNF-R PILOT-IND MPX IN NOISE DET IN MPX-OUT FM DEMODULA

39、TOR FM-IF AMPLIFIER +VS-RF AM/FM FS AM-SEEK MODE SW AM-IF COUNTER FM-IF IN (450K) AM-IF IN 2.LO 2.LO OUT(450K) AM-IF FOSC 1.LO 1.LO FM-IN FM-IN AM-IN AM-IN AM-IF OUT AM-IF OUT FM-IF OUT FM-IF OUT ND-RF VS-RF N AGC for AM-/FM-PRESTAGE FM-MIXER AM-MIXER 1.LO OSCILLATOR 2.LO OSCILLATOR AM-DEMODULATOR N

40、OISE BLANKER AM-AGC AMP 1.IF IF CONVERTER STEREODECODER 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48474645444342414039383736353433 16151413121110987654321 CIC01 FMP201 10R CR30 FMP21 + 10U/16V C613A 10K CR110 + 22U/16V C104 510K CR116 1N0 CC18 R200 47K FMP28 470P CC201 R108 10R 120K CR204 10K

41、R206 6X 432 51 F604A 360K CR114 22K CR15 180K CR118 470K CR117 22N CC103A 220P CC32A 78 2 3 4 6 1 F603A 47N CC24 1N0 CC23 300K CR113 41 8637 F106 470R R617A NP02N2 CC614A 100N CC616A 10N CC28 1K8 CR611A 22N CC112 100N CC22 6N8 CC204 100N CC617A 100N CC618A 4K7 CR08 10K R109 10N CC109 470R CR107 47N

42、CC108 100P CC107 100N CC106 CSB456F11 Q201 10K CR616 100N CC214 10N CC213 R614A 10R R07 100R 22P CC217 68P CC212 100N CC208 47K CR202 100K CR203 51K CR201 1N0 CC21 130K CR112 F 100N C202 100N CC206 CC216 NP0 1N0 CC27 NP0 1N0 CC26 + 2U2/35V C105 + 1U0/50V C113 100P CC620A LO -M F STER R R LOC Q-10.25

43、MHZ AM-SEE AM/F +S MULTI B A 8V6 Abstimmspannung 2, Tuning Voltage 2.0V AM-FM OSCILLATOR G 5V 5V 5V Schaltplne und Druckplattenabbildungen / Circuit Diagrams and Layout of PCBs 8GRUNDIG Service SEAT 3301 1N0 CC713 10N CC712A BC848C CT707A FMP617 10K CR718A FMP106 FMP217 200 202 OSCIN INLOCK HFREF AM

44、_IN SSTOP IF_FM IF_AM SDA SCL ADDR OSCOUT FM_IN 11 - 21 BIT PROG.CNT CONTROLTIMER14 BIT PROG.CNT INTERFACE I2C BUS 16 BIT PROG.CNTREF.OSCILLATOR 11 BIT PROG.CNT SWM/DIRSWM/DIR SWITCHSWITCH 5 BIT PROG.CNT :32/33 PRECOUNTER AM/FM SWITCH 9 10 12 13 14 15 16 19 20 24 25 201 21 1K8 CR714A 10,25MHZ Q701 F

45、MP16 22N CC702 R200 47K 28 FMP726FM FMP714 R108 10R CR704A 10K 220P CC718A 10K CR717A 1K2 CR106 BC848C CT706A 4 86 6 470R CR107 47N 33K R731 10K CR721A N 14 R719 33K 6K8 CR715A 100N CC216 LOC-OSC LOC-OSC -MONO/ST +G +G +G FELDST MPX STEREO-ANZ RF-NF-R RF-NF-L LOC-OSC/10 LOC-OSC/10 Q-10.25MHZ FM-SW AM-SEEK

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 德国收音机 > 根德GRUNDIG

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号