1、HR-16/HR16B Service Manual 1.00 i 03/31/06 HR-16/HR-16B Drum Machines Service Manual V1.00 7/27/95 RadioFans.CN 收音机爱 好者资料库HR-16/HR16B Service Manual 1.00 ii 03/31/06 PREFACE This document is intended to assist the service technician in the operation, maintenance and repair of the HR-16 and HR-16B Dr

2、um Machines. Together with the HR-16/B Reference Manual, this document provides a complete description of the functionality and serviceability of these machines. Any comments or suggestions you may have pertaining to the document are welcome and encouraged. READ THIS! In addition to any purchase pri

3、ce that Alesis may charge as consideration for Alesis selling or otherwise transferring this service manual (“Manual”) to you, if you are not a service and repair facility (“Service Center”) authorized by Alesis in writing to be an authorized Service Center, Alesis sells or transfers the Manual to y

4、ou on the following terms and conditions: Only Service Centers authorized by Alesis in writing are authorized to perform service and repairs covered by an Alesis warranty (if any), and transfer of the Manual to you does not authorize you to be an authorized Service Center. Therefore, if you perform,

5、 or if the Manual is used to perform, any service or repairs on any Alesis product or part thereof, any and all warranties of Alesis as to that product and any service contract with Alesis for that product shall be voided and shall no longer apply for such product, even if your services or repairs w

6、ere done in accordance with the Manual. All service or repairs done by you or with reference to the Manual shall be solely your responsibility, and Alesis shall have no liability for any such repairs or service work. All such service or repairs are performed at the sole risk of the person performing

7、 the service or repairs. You agree that all such work will be performed in a competent, professional and safe manner at all times and to indemnify and fully hold Alesis and its successors and assigns harmless in the event of any failure to so perform. Your purchase of the Manual shall be for your ow

8、n ultimate use and shall not be for purposes of resale or other transfer. As the owner of the copyright to the Manual, Alesis does not give you the right to copy the Manual, and you agree not to copy the Manual without the written authorization of Alesis. Alesis has no obligation to provide to you a

9、ny correction of, or supplement to, the Manual, or any new or superseding version thereof. Alesis shall have the right to refuse to sell or otherwise transfer repair parts or materials to you in its sole discretion. You shall not use, sell or otherwise transfer spare or replacement parts supplied by

10、 Alesis to you (i) to repair or be used in products manufactured for or by third parties or (ii) to any third parties for any purpose. You shall not make any warranties or guarantees with respect to the products of Alesis or the use thereof on behalf of Alesis or in your own name. The foregoing desc

11、ribes the entire understanding related to sale or transfer of the Manual to you, and no other terms shall apply unless in a writing signed by an authorized representative of Alesis. RadioFans.CN 收音机爱 好者资料库HR-16/HR16B Service Manual 1.00 iii 03/31/06 WARNINGS TO REDUCE THE RISK OF ELECTRIC SHOCK OR F

12、IRE, DO NOT EXPOSE THIS PRODUCT TO WATER OR MOISTURE. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The arrowhead symbol on a lightning flash inside a triangle is intended to alert the user to the presence of un-insulated dangerous voltage within the enclosed product which may be of sufficient magnitud

13、e to constitute a risk of electric shock to persons. The exclamation point inside a triangle is intended to alert the user to the presence of important operating, maintenance and servicing instructions in the literature which accompanies the product. CAUTION Danger of explosion if battery is incorre

14、ctly replaced. Replace only with the same type or equivalent type recommended by the equipment manufacturer. Battery Manufacturer: Tadiran Type: TL-5101 Rating 3.6V REPAIR BY ANY PERSON OR ENTITY OTHER THAN AN AUTHORIZED ALESIS SERVICE CENTER WILL VOID THE ALESIS WARRANTY. PROVISION OF THIS MANUAL D

15、OES NOT AUTHORIZE THE RECIPIENT TO COMPETE WITH ANY ALESIS DISTRIBUTOR OR AUTHORIZED REPAIR SERVICE CENTER IN THE PROVISION OF REPAIR SERVICES OR TO BE OR MAKE REPAIRS AS AN AUTHORIZED SERVICE CENTER. ALL REPAIRS DONE BY ANY ENTITY OTHER THAN AN AUTHORIZED ALESIS SERVICE CENTER SHALL BE SOLELY THE R

16、ESPONSIBILITY OF THAT ENTITY, AND ALESIS SHALL HAVE NO LIABILITY TO THAT ENTITY OR TO ANY OTHER PARTY FOR ANY REPAIRS BY THAT ENTITY. RadioFans.CN 收音机爱 好者资料库HR-16/HR16B Service Manual 1.00 iv 03/31/06 SAFETY SUGGESTIONS Carefully read the applicable items of the operating instructions and these safe

17、ty suggestions before using this product. Use extra care to follow the warnings written on the product itself and in the operating instructions. Keep the operating instructions and safety suggestions for reference in the future. 1. Power Source. The product should only be connected to a power supply

18、 which is described either in the operating instructions or in markings on the product. 2. Power Cord Protection. AC power supply cords should be placed such that no one is likely to step on the cords and such that nothing will be placed on or against them. 3. Grounding the Plug. This product has a

19、3-wire grounding type of plug (a plug with a grounding pin) for safety purposes. This plug can only be used in a grounding power outlet. If the plug does not insert into the outlet you are using, the outlet probably is not a grounding type of power outlet. Contact your electrician to replace the obs

20、olete outlet with a grounding type of outlet instead of defeating the safety feature of the grounding type of plug. 4. Periods of Non-use. If the product is not used for any significant period of time, the products AC power supply cord should be unplugged from the AC outlet. 5. Foreign Objects and L

21、iquids. Take care not to allow liquids to spill or objects to fall into any openings of the product. 6. Water or Moisture. The product should not be used near any water or in moisture. 7. Heat. Do not place the product near heat sources such as stoves, heat registers, radiators or other heat produci

22、ng equipment. 8. Ventilation. When installing the product, make sure that the product has adequate ventilation. Improperly ventilating the product may cause overheating, which may damage the product. 9. Mounting. The product should only be used with a rack which the manufacturer recommends. The comb

23、ination of the product and rack should be moved carefully. Quick movements, excessive force or uneven surfaces may overturn the combination which may damage the product and rack combination. 10. Cleaning. The product should only be cleaned as the manufacturer recommends. 11. Service. The user should

24、 only attempt the limited service or upkeep specifically described in the operating instructions for the user. For any other service required, the product should be taken to an authorized service center as described in the operating instructions. 12. Damage to the Product. Qualified service personne

25、l should service the unit in certain situations including without limitation when: a. Liquid has spilled or objects have fallen into the product, b. The product is exposed to water or excessive moisture, c. The AC power supply plug or cord is damaged, d. The product shows an inappropriate change in

26、performance or does not operate normally, or e. The enclosure of the product has been damaged. RadioFans.CN 收音机爱 好者资料库HR-16/HR16B Service Manual 1.00 v 03/31/06 General Troubleshooting While this manual assumes that the reader has a fundamental understanding of electronics and basic troubleshooting

27、techniques, a review of some of the techniques used by our staff may help. 1. Visual Inspection - A short visual inspection of the unit under test will often yield results without the need of complex signal analysis (burnt, or loose components are a dead giveaway). 2. Self Test - Alesis products tha

28、t utilize microprocessor control contain built in test software which exercises many of the units primary circuit functions. Self test should always be done following any repair to ensure basic functionality. 3. Environmental Testing - Applying heat and cold (heat gun/freeze spray) will often reveal

29、 thermally intermittent components (Clock crystals, I.C.s, and capacitors are particularly prone to this type of failure). 4. Burn in Testing - Leaving a unit running overnight often reveals intermittent failures such as capacitors that begin to leak excess current after a significant amount of time

30、. 5. Cable Checks - Wiggling cables can reveal intermittent failures such as loose cables or poorly soldered headers. Remember to check power supply cables as well. 6. Flexing the PC Board - Poor solder joints and broken traces can often be found by pressing the PC Board in various places. 7. Tappin

31、g Componants - Somtimes tapping on a component (particularly crystals) will cause it to fail. 8. Power Down/up - Turning the unit off and back on rapidly several times may reveal odd reset and/or power supply failures. 9. Reset Threshold - A Variac (variable transformer) can be used to check reset t

32、hreshold levels. This can be particularly useful in helping customers with low line problems. 10. Compressors - Using a compressor/limiter is often helpful when attempting to solve low level noise problems, as well as assisting with DAC adjustments. 11. Sweep Tests - Sweep generators are very useful

33、 in checking the frequency response envelopes of anti-aliasing filters. 12. Piggybacking - Piggybacking I.C.s is particularly useful when troubleshooting large sections of logic. This is especially true when working with older units. RadioFans.CN 收音机爱 好者资料库HR-16/HR16B Service Manual 1.00 vi 03/31/06

34、 TABLE OF CONTENTS PREFACE.ii READ THIS! .ii WARNINGS.iii SAFETY SUGGESTIONS.iv General Troubleshooting.v 1.0 General Description .1 1.1 Main PC Board Revisions .1 2.0 Power Supply.1 2.1 Battery Backup.2 2.2 PUP Circuit.2 3.0 The 8031 .3 3.1 Reset.3 3.2 Memory Mapped I/O.4 3.3 Keypad I/O.4 3.4 MIDI

35、I/O .4 4.0 DM3AG ASIC.5 4.1 Mask ROMs.5 5.0 Analog Signal Paths.6 5.1 Drum Signal Output.6 5.2 Piezo/Data Slider Input.6 5.3 Tape I/O.6 5.4 Tape Output.7 5.5 Tape Input .7 6.0 Test Procedures.7 6.1 General Testing.8 6.2 Internal Diagnostics and Hidden Keys.8 6.3 DAC Adjustments.8 7.0 Updates and Cor

36、rections .9 7.1 New SRAM Supply Circuit.9 7.2 Glass Zener (D15).9 7.3 Dirty Cliff jacks.10 7.4 Ground CE.10 7.5 RF resistor.10 7.6 10K MIDI Resistor (R5).11 7.7 MIDI Pullup.11 7.8 RF Shields.11 7.9 LCD Contrast Adjustments.11 7.10 DAC Drift .12 7.11 Old Keypad PC Boards.12 7.12 Lifting R41 .12 7.13

37、Reset Capacitor.12 7.14 Sram Capacitor .12 7.15 Tape Capacitors.13 7.16 RF chokes .13 7.17 AQ reset threshold .13 7.18 AQ R116.13 7.19 Volume Slider Wiring.13 7.20 PUP Capacitor.14 8.0 Common Solutions.15 9.0 Service Parts List .18 10.0 Software History.20 11.0 MIDI Implementation.23 12.0 Service Ma

38、nual History .31 INDEX.32 RadioFans.CN 收音机爱 好者资料库HR-16/HR16B Service Manual 1.00 1 1.0 General Description Diagram 1 provides a simplified block diagram to show major sub systems. Note that the schematic reference designations and pinouts used in this manual refer to the AQ revision of both the main

39、 PCB, and schematic. 1.1 Main PC Board Revisions There are 3 major main PC Board revisions. A-This was the initial release. This board revision will require the most extensive updating of the three. CA-This version of the board was a 4 layer design. While offering several advantages over the older v

40、ersion (improved R.F. characteristics, smaller size, etc.) it was found to be extremely difficult to service (internal shorts can only be repaired using lifted pins and jumpers). AQ-This was the final revision. This revision will of course need the fewest updates, and should be relatively easy to tr

41、oubleshoot. Diagram 2 is provided in order to assist with board revision identification. 2.0 Power Supply The power supply begins with the 9 Volt A.C., adapter (Alesis P2 mini plug or P3 barrel types). Input from J1 is R.F. filtered before on/off switch S1. From there it is split for the +12V, -12V,

42、 and +5V rails. The +12V rail consists of a voltage doubler (C1, C3, and D2, D3), a 7812 regulator (U8), and a filter capacitor (C6). The -12V rail is a mirror of the +12V rail, consisting of voltage doubler (C2, C4, and D1, D4), a 7912 regulator (U9), and a filter capacitor (C7). The +5V rail consi

43、sts of a rectifier diode (D5), a filter capacitor (C5), a 7805 regulator (U10), and a multitude of 0.1F bypass capacitors. Note that the raw +10V line used by the microprocessor reset, and the SRAM power supply (when retrofitted), is located at the input to the 7805 regulator. Note that revision AQ

44、(the latest) boards also incorporate several R.F. suppression chokes and current limiting resistors. These have resulted in a few unique situations that may need to be dealt with (see section 7.16 for details) Diagram 1 RadioFans.CN 收音机爱 好者资料库HR-16/HR16B Service Manual 1.00 2 2.1 Battery Backup Batt

45、ery backup is actually more complicated than it might first appear, as it depends on a good system reset (see section 3.1 for details) in order to function properly. The actual backup circuit consists of a battery (3V - 3.6V Lithium), a 10K resistor (R97) for checking standby current (see below), a

46、steering diode (D7), a filter capacitor (C59), and a transistor/resistor/diode combination that acts as a steering diode. This combination may be missing on older board revisions, and must be installed (see section 7.1) to prevent data corruption due to a significant difference between Vcc and the a

47、mplitude of the data buss. SRAM standby current should always be checked. While the unit is off, check the voltage across R97. If the voltage is higher than 80mV (specification, although a 1 to 20mV range is more normal) then a problem exists. Usually it indicates a bad (or simply wrong) SRAM, or a

48、short somewhere along the MEM PWR line. Note that for a short time Sony 58256-PM (high power) SRAMs were being installed at the factory, causing batteries to drain in about 1 year. They should be replaced with low power versions (58256-LP) when found, in order to eliminate excess battery drain. We a

49、re currently using Hitachi 62256ALPs as replacements. CAUTION:Danger of explosion if battery is incorrectly replaced. Replace only with the same type or equivalent type recommended by the equipment manufacturer. Battery Manufacturer: Tadiran Type: TL-5101 Rating 3.6V 2.2 PUP Circuit The PUP (quiet P

50、ower UP) circuit is designed to prevent the unit from making noise during power up. Note that this circuit will not be present on the earliest main PC boards. The circuit utilizes the RESET line (section 3.1) to control the power supply lines to U20, which is the final active stage before the output

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 功放/音响/收扩 > Alesis

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号