1、1CAUTION: THE 1800-V PROFESSIONAL STEREO POWERAMPLIFIER SYSTEM CONTAINS NO USER-SERVICEABLE PARTS.TO PREVENT WARRANTY INFRACTIONS, REFER SERVICING TOWARRANTY SERVICE STATIONS OR FACTORY SERVICE.PROPRIETARY INFORMATIONTHIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OFBOSE CORPORATION WHICH IS BEING FU

2、RNISHED ONLY FORTHE PURPOSE OF SERVICING THE IDENTIFIED BOSE PRODUCTBY AN AUTHORIZED BOSE SERVICE CENTER OR OWNER OF THEBOSE PRODUCT, AND SHALL NOT BE REPRODUCED OR USEDFOR ANY OTHER PURPOSE.Table of ContentsSAFETY INFORMATION. 2SUPPLEMENT OVERVIEW AND PROCEDURES . 3Figure 1. 1800-V Amplifier PCB. 4

3、Figure 2. 1800-V Power Supply PCB . 4Figure 3. 1800-V Regulator PCB . 4RadioFans.CN 收音机爱 好者资料库21. Parts that have special safety characteristics are identified by the symbol onschematics or by special notes on the parts list. Use only replacement parts that havecritical characteristics recommended b

4、y the manufacturer.2. Make leakage current or resistance measurements to determine that exposed partsare acceptably insulated from the supply circuit before returning the unit to thecustomer. Use the following checks to perform these measurements:A. Leakage Current Hot Check-With the unit completely

5、 reassembled, plug the ACline cord directly into a 120V AC outlet. (Do not use an isolation transformer duringthis test.) Use a leakage current tester or a metering system that complies withAmerican National Standards Institute (ANSI) C101.1 Leakage Current for Appli-ances and Underwriters Laborator

6、ies (UL) 1492 (71). With the unit AC switch first inthe ON position and then in OFF position, measure from a known earth ground(metal waterpipe, conduit, etc.) to all exposed metal parts of the unit (antennas,handle bracket, metal cabinet, screwheads, metallic overlays, control shafts, etc.),especia

7、lly any exposed metal parts that offer an electrical return path to the chassis.Any current measured must not exceed 0.5 milliamp. Reverse the unit power cordplug in the outlet and repeat test. ANY MEASUREMENTS NOT WITHIN THE LIM-ITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCK HAZARD THAT MUSTBE ELI

8、MINATED BEFORE RETURNING THE UNIT TO THE CUSTOMER.B. Insulation Resistance Test Cold Check-(1) Unplug the power supply and con-nect a jumper wire between the two prongs of the plug. (2) Turn on the power switchof the unit. (3) Measure the resistance with an ohmmeter between the jumpered ACplug and e

9、ach exposed metallic cabinet part on the unit. When the exposed metallicpart has a return path to the chassis, the reading should be between 1 and 5.2Megohms. When there is no return path to the chassis, the reading must be infi-nite. If it is not within the limits specified, there is the possibilit

10、y of a shock hazard,and the unit must be repaired and rechecked before it is returned to the customer.SAFETY INFORMATION!RadioFans.CN 收音机爱 好者资料库3This supplement provides two additional test procedures, which will assist in the diagnosisand repair of the 1800-V Amplifier.Use the following procedures

11、to check and adjust the Output Bias and High-voltage Rails.Channel 1 and 2 Output Bias Adjust:NOTE: The bias should be set without an input signal or load on the outputs.The components involved in this procedure are located on the Amplifier PCB, refer toFigure 1 for their location.To adjust the bias

12、 of Channel 1, measure across one of the output emitter resistors(R146, R148, R150, R151 and R153) with a DC meter (the DC meters -input should befloated). Adjust R124 until the DC meter reads 1 mV. To ensure that the emitter resistorsshare the bias current equally, its recommended that two or three

13、 be measured. Equal biascurrent sharing is indicated by a 1 mV voltage drop across each emitter resistor.To adjust the bias of Channel 2, measure across one of the output emitter resistors(R246, R248, R250, R251 and R253) with a DC meter (the DC meters -input should befloated). Adjust R224 until the

14、 DC meter reads 1 mV. To ensure that the emitter resistorsshare the bias current equally, its recommended that two or three be measured. Equal biascurrent sharing is indicated by a 1 mV voltage drop across each emitter resistor.High-voltage Rail Adjust:NOTE: The rail voltages should be set with the

15、line voltage at its nominal value and withoutan input signal or output load.The Test Points TP1, TP2 and TP3 are located on the Power Supply PCB, refer to Figure 2.Potentiometer R36 is located on the Regulator PCB, refer to Figure 3.To adjust the high-voltage rail use a DC meter to measure across TP

16、1 and TP3. Adjust R36on the Regulator PCB until the meter reads -106 volts ( 2 VDC). The reading across TP1and TP2 should be approximately +104 volts.SUPPLEMENT OVERVIEW AND PROCEDURESFigure 1. 1800-V Amplifier PCBFigure 3. 1800-V Regulator PCBFigure 2. 1800-V Power Supply PCBFOR TECHNICAL ASSISTANCE OR PART ORDERS, CALL 1-800-367-4008P/N 181812-S1 12/95SPECIFICATIONS AND FEATURES SUBJECT TO CHANGE WITHOUT NOTICEBose CorporationThe MountainFramingham, Massachusetts USA 01701