AustralianMonitor-AMIS1202P-pwr-sm维修电路原理图.pdf

上传人:cc518 文档编号:145414 上传时间:2022-07-06 格式:PDF 页数:18 大小:680.45KB
下载 相关 举报
AustralianMonitor-AMIS1202P-pwr-sm维修电路原理图.pdf_第1页
第1页 / 共18页
AustralianMonitor-AMIS1202P-pwr-sm维修电路原理图.pdf_第2页
第2页 / 共18页
AustralianMonitor-AMIS1202P-pwr-sm维修电路原理图.pdf_第3页
第3页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《AustralianMonitor-AMIS1202P-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《AustralianMonitor-AMIS1202P-pwr-sm维修电路原理图.pdf(18页珍藏版)》请在收音机爱好者资料库上搜索。

1、 Australian Monitor 1 Clyde Street, Silverwater NSW 2128 Australia +61 2 9647 1411 .au SERVICE INFORMATION AMIS1202P POWER AMPLIFIER CONTENTS: OPERATION MANUAL SCHEMATIC DIAGRAMS BOARD LAYOUT SERVICE BULLETINS * Over the years there have been a number of revisions to this model RadioFans.CN 收音机爱 好者资

2、料库 Clever Features, Contractor Friendly AMIS1202P 2 x 120w Power Amplifier Operating Manual AMIS1202P, 2 x 120 Watt Power Amplifier Product Description The AMIS1202P is a dual 120 watt power amplifier designed for commercial installations. The one unit contains two independent 120 watt amplifiers fo

3、r either stereo or dual zone applications. The AMIS1202P can be used for either low impedance (4 or 8 ohm) or 70/100v line speaker systems per channel. The amplifier can be mounted in a standard 19” equipment rack (rack ears supplied) or it can be used on a shelf or table. The AMIS1202P features a l

4、ine level input (with parallel output) per channel and is normally used with mixers, mixer amplifiers or other power amplifiers. RadioFans.CN 收音机爱 好者资料库 Front Panel Features Power Switch The black rocker switch on the right hand side of the front panel is used to switch the amplifier on and off. The

5、 up position is on. When the amplifier is connected to an appropriate AC power source and is switched on, the blue power LED will illuminate. This switch will not switch DC power on or off in DC operation. In DC operation mode, the amplifier is always on and the blue power LED will always be illumin

6、ated. On LED The blue “On” LED above the power switch will illuminate when the amplifier is connected to mains power and is switched on. In 24vdc operation the LED will always be on. Signal LED The green “Signal” LEDs located next to the On LED indicate that the AMIS1202P is receiving audio signal v

7、ia its line level inputs. One LED is provided per channel. The signal LEDs are a simple way of trouble-shooting installations especially in multi amplifier projects. At a glance the signal LEDs will indicate that audio is reaching the amplifier. Rack Mounting The AMIS1202P is supplied with rack ears

8、 attached to allow mounting within a standard 19” equipment rack. As is the case with almost all audio products, adequate ventilation and air flow is required. When installing multiple AMIS amplifiers within the one rack, it is recommended that at least one rack unit of ventilation space is left bet

9、ween every two amplifiers. For table or shelf mounting, the rack ears can be removed using a screwdriver. Once the rack ears are removed, please reinstall the screws. Rear Panel Features AC Power Inlet The operating voltage is 230/240 VAC 50 Hz. The 3 pin IEC power inlet is located on the bottom lef

10、t of the rear panel and accepts a standard mains power lead fitted with an IEC connector. Before plugging in a power lead, please check the rear panel of the amplifier to ensure that the voltage switch is set correctly for your part of the world. The inlet is equipped with an in-built AC fuse holder

11、 fitted with an 4 Amp slow blow fuse plus a spare fuse. Please ensure that the mains power cord is disconnected before attempting to check or replace this fuse. Power consumption is 400 VA (max). 230V/240V Slide Switch The operating voltage of the amplifier is user selectable between 230V and 240V v

12、ia a slide switch located on the right of the AC inlet. This switch should be set to match the AC voltage of your country 24 Volt DC Power Inlet The AMIS1202P feature optional 24VDC power to run off a battery back-up if required. This is connected via the rear terminal strip. The front panel Power S

13、witch will not switch DC power on or off in DC operation. In this mode the amplifier is always on. Speaker Output Terminal Strip Located on the top left of the rear panel are the speaker output terminal strips. A terminal strip is provided for each of the two amplifiers. Reading from left to right,

14、the connections per terminal strip are: COM Common or “-” for low impedance speaker loads (4 or 8 ohms). 4 The “+” for 4 ohm speaker loads (use with common) 8 The “+” for 8 ohm speaker loads (use with common) COM Common or “-” for 70v or 100v speaker loads (maximum load of 80 ohms at 100v) 70 The “+

15、” for 70v line speaker loads (use with common) 100 The “+” for 100v line speaker loads (use with common) Please ensure that the correct “Common” is used. Low impedance and 70/100v loads can be used simultaneously but please pay careful attention to the overall speaker load. When used individually, t

16、he low impedance load should be 4 ohms or higher while the 100v line load should not fall below 80 ohms per amplifier. When both low impedance and 70/100v outputs are used simultaneously on the one amplifier, ensure that neither output is loaded to maximum. Level Control Located next to the XLR inpu

17、t/output is a recessed screwdriver adjustable level control. One is provided per amplifier channel. The level control is an input attenuation control normally used to match the amplifier to a wide variety of input signals. In essence, the amplifier is designed to receive a 700mv input signal however

18、 the level control can be used to increase the level for lower signals or decrease the level for higher input signals. In normal use, the level control is used as a set and forget master level control for the amplifier. XLR Audio Input and Parallel Output The AMIS1202P includes both male and female

19、3 pin XLR connectors per channel. While the female is normally used as the input to the amplifier, both XLRs are connected in parallel so either will work. When signal is connected to one XLR, the other XLR becomes a line level output allowing the input signal to be distributed (split) to other ampl

20、ifiers. In some projects, the same input may be looped through to multiple amplifiers using this method. Up to 6 amplifiers can be looped together without any noticeable loss in level. A distribution amplifier should be used when more than 6 amplifiers need to be looped. The XLRs are wired as follow

21、s: Pin 1: Shield. Pin 2: Hot, +, Positive. Pin 3: Cold, -, Negative Fuse Sizes Mains, 230VAC: 4 Amperes Slow Blow. Notes: The DC fuse is located on the circuit board. This is a feature of the AMIS series amplifier, which is equipped with a current limiting circuit preventing excessive DC current, th

22、us eliminating the risk of blowing high tensions fuses. In the unlikely event that the DC fuse actuates, the output transistors should be checked, as it is probable that the amplifier has been subjected to very extreme conditions. Important Safety Information 1. Save the carton and packing material

23、even if the equipment has arrived in good condition. Should you ever need to ship the unit, use only the original factory packing. 2. Read all documentation before operating your equipment. Retain all documentation for future reference. 3. Follow all instructions printed on unit chassis for proper o

24、peration. 4. Do not spill water or other liquids into or on the unit, or operate the unit while standing in liquid. 5. Make sure power outlets conform to the power requirements listed on the back of the unit. 6. Do not use the unit if the electrical power cord is frayed or broken. The power supply c

25、ords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance. 7. Always operate the unit with the AC ground wire connected t

26、o the electrical system ground. Precautions should be taken so that the means of grounding of a piece of equipment is not defeated. 8. Mains voltage must be correct and the same as that printed on the rear of the unit. Damage caused by connection to improper AC voltage is not covered by any warranty

27、. 9. Have gain controls on amplifiers turned down during power-up to prevent speaker damage if there are high signal levels at the inputs. 10. Power down & disconnect units from mains voltage before making connections. 11. Never hold a power switch in the “ON” position if it wont stay there itself!

28、12. Do not use the unit near stoves, heat registers, radiators, or other heat producing devices. 13. Do not block fan intake or exhaust ports. Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit, such as a bed, rug, weathersheet, carpet,

29、 or completely enclosed rack. If the unit is used in an extremely dusty or smoky environment, the unit should be periodically “blown free” of foreign matter. 14. Do not remove the cover. Removing the cover will expose you to potentially dangerous voltages. There are no user serviceable parts inside.

30、 15. Do not drive the inputs with a signal level greater than that required to drive equipment to full output. 16. Do not connect the inputs / outputs of amplifiers or consoles to any other voltage source, such as a battery, mains source, or power supply, regardless of whether the amplifier or conso

31、le is turned on or off. 17. Do not run the output of any amplifier channel back into another channels input. Do not parallel- or series-connect an amplifier output with any other amplifier output. Australian Monitor is not responsible for damage to loudspeakers for any reason. 18. Do not ground any

32、red (“hot”) terminal. Never connect a “hot” (red) output to ground or to another “hot” (red) output! 19. Non-use periods. The power cord of equipment should be unplugged from the outlet when left unused for a long period of time. 20. Service Information Equipment should be serviced by qualified serv

33、ice personnel when: A. The power supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the equipment C. The equipment has been exposed to rain D. The equipment does not appear to operate normally, or exhibits a marked change in performance E. The equipment

34、 has been dropped, or the enclosure damaged. Engineered in Sydney, Australia .au International Sales & Corporate Head Office Private Bag 149, Silverwater NSW 1811 149 Beaconsfield Street, Silverwater NSW 2128 Australia Ph: 61-2- 9647 1411 Fax: 61-2-9748 2537 E-mail: ABCDDCBATitleNumberRevisionSizeA3

35、Date:13-Feb-2006Sheet of File:C:Protel FilesCDTRAXCD6262-21.DDBDrawn By:D51N4004VCCC16470uC1547uIC4LM7815R1847RVCCVCCC1410uC134u7C124u7D3D2D1IC2BIC2AR1710KR16100RR155K6R141KR1322RR12100KR1182KR102M2R933KC112u2C102u2C92u2C84u712356784910111214151613IC3ANE570R822KR750KIC1AC5100PC4100PC34u7C24u7C14u7R4

36、10KR310KR210KR110KC17330PR19100KR20100KC18330PR2110KR2210KR2310KR2410KC194u7C204u7C214u7C22100PC23100PIC2R2650KR2722K12356784910111214151613IC5ANE570C244u7C252u2C262u2C272u2R2833KR292M2R3082KR31100KR3222RR331KR345K6R35100RR3610KIC6IC7D4D6D7C284u7C294u7C3010uVCCVCCV1R54K7R64K7R253K9R37100RC647uC74u7C

37、314u7RS11INPUT15VDC33VDCOUTPUTX3/1X2/1X1/1JP1332211XLR-MXLR-FXLR-FXLR-M112233JP1INPUTAGAGX4/1OUTPUTAG7.5VDCAMIS1202 INPUTCD6262-112345678ABCD87654321DCBATitleNumberRevisionSizeA3Date:18-Jan-2007Sheet of File:C:ATCAMIS1202PAMIS1202P.ddbDrawn By:R2010KR1933KR1710KR1610KR1510KR1410KC1247PC11100PIC2BIC3

38、BIC3AIC1BC10100PC947PR1310KR1210KR1110KR1010KR933KD51N4004VCCC16470uC15470uIC4LM7815R1847RC84u7R810KR750KIC1AC5100PC4100PC34u7C24u7C14u7R410KR310KR210KR110KR2110KR2210KR2310KR2410KC194u7C204u7C214u7C22100PC23100PIC2AR2650KC244u7V1BC546R54K7R64K7R253K9R27100RC647uC14.1uC7.1uC13.1uC1747uVCCVCCVCCB11IN

39、PUT15VDC33VDCX2/1X1/1332211XLR-MXLR-FXLR-FXLR-M112233INPUTAGAGAG7.5VDCAMIS1202P INPUTCD6262-1X134X312RS-I-l3&ztu(s(ar1fICIo(oAOCoot12345678ABCD87654321DCBATitleNumberRevisionSizeA3Date:5-Feb-2003 Sheet of File:C:AMIS60-120 ManualCD6289-22.DDB Drawn By:C281nFC271nFVCCV17BC546D12BAV21D112V7R492K7R4810

40、KR4710KR321KC16.1uC19.1uVCCR464K7R454K7C34u7R441KC18330PC17330PR431KC84700uV16TIP36CR420R22R410R22V15TIP36CLK1X1X2R4015R/2WD51N4004C2120pC4120pVCCR3110RC1047uF1C74700uIC2LM7818C11100nR20R22R10R22R250R22R260R22V6TIP36CV2TIP36CR101kR131MR510kR947kR33100RR43k3R71kR610kR3470RR300R1IC1ALM1458C1470nV7BC63

41、9V3BD140V9TIP42CV1TIP36CR111kR221kV5TIP36CV10TIP42CV8BC639C6470nC54u7IC1BLM1458R17470RR2010kR191kR163k3R34100RR1447kR1510kR211MR241kV4BD140V11BC639R8330RR18330RR29100KR271kD1BAV21D4BAV21V12BC640C910nR28560RD3BAV21D2BAV21R122k2R232k2C1222PC1322PV13BC639R3522KR36470kD61N4004D71N4004C1447uC1547uRY1R375

42、60RV14BC640R381kR390R1LK2B1B2T1S1CX122n/400VCX2220nF24ampGNDCHTEMP CUTOUTAMIS120 POWER AMPCBATTERY TERM24VAC35VDCCT OUTPUT TR48FROM MIXER PCBBPBPPW510A S/B4PRE AMP653X1/8X1/7PW5PW5PW5PW5PW5BAT NEGBAT POS+35VDC-IN+IN35VDCCD6289-2123567PW52RS21235VDCPOWER GNDPOWER GNDX1/10X1/9240VAC24VDC-T12345678ABCD

43、87654321DCBATitleNumberRevisionSizeA3Date:15-Mar-2006Sheet of File:C:ATCAMIS120AMIS120-60.DDBDrawn By:VCCV13TIP36CR261K1V8BC640R271KRY1C1647uC1747uD81N4004D61N4004R35470kR3422KV5BC639C1522PR251KV6BC640R241K1R21150RR15150RR12470R R11100K R174K7R184K7VR12KR201KR226K8 R23100RIC2BNE5532C8470pFV15BC639V1

44、6TIP42CR131KR101KV11TIP42CV10BC639IC2ANE5532R19100RR166K8 R141KVR22KR8100K R9470RC28100nIC3LM7812C184700uFC21220uR3722RVCCC5100PC3100PD71N4004X2V12TIP36CR410R22R420R22C194700uFC10470pFC20220uVCCV14TIP36CV19TIP36CR430R22R450R22R460R22V17TIP36CV18TIP36CR470R22IC1ALM1458IC1BLM1458R710KR24K7R510KR610K V

45、CCR44K7C4100PR3882RC29.1uV7BC639C11.01uV9BC639C13.01uD101N5818CH1C25220uC2647uFC24.1uV3BC639R294K7R284K7D4IN4004D3IN4004X1LK1R302K2LK2F110 S/BR3622R 2WB1B2T1CX2.22uCX122N/400VS1F23.15 A S/BC22.1uRS76532135VDC84AMIS 120 POWER AMPCD6338-22 of2TO 24VACX1/16+BAT TERMINALPOWER TRX1/15-12V41235678-12V1234

46、5678-12VDCIC4MAX765TEMP CUTOUTX1/14X1/13+35VDCPRE AMPINPUT240VAC24VDCNOT ON PCBD96V8LK6LK7LK6LK7R3910RC2747uFV2BD139V1BD139D1IN4004D2IN4004C9.1uFC1422PR110KR310K-12V35VDCV4BD139R402K2R49470R 2WD1520VC23100u24V FAN+35VCX3.1uRX110R 5WX1/7X1/8X1/9X1/10X1/11X1/12X1/12 100 V to Barrier stripX1/11 100 V i

47、n from XFX1/9 Com from XF 4/8 ohmX1/10 Com from XF 100VX1/8 Com out to Barrier stripX1/7 Com out to Barrier strip654321LK9LK10C1.47uFC2.47uFD15 = 15V for AMIS120D15 = 20V for AMIS1202PIC5ALM358IC5BLM358C1247uR486K8R511K2R52100KR3110K NTCR3310KD161N4148D141N4148R3210KR501K5R53100KD52V7+12VBBTemp Cut

48、outC6220uB12345678ABCD87654321DCBATitleNumberRevisionSizeA3Date:1-Feb-2007 Sheet of File:C:ATCAMIS120AMIS120-60.DDBDrawn By:VCCV13TIP36CR261K1V8BC640R271KRY1C1647uC1747uD81N4004D61N4004R35470kR3422KV5BC639C1522PR251KV6BC640R241K1R21150RR15150RR12470R R11100K R174K7R184K7VR12KR201KR226K8 R23100RIC2BN

49、E5532C8470pFV15BC639V16TIP42CR131KR101KV11TIP42CV10BC639IC2ANE5532R19100RR166K8 R141KVR22KR8100K R9470RC28100nIC3LM7812C184700uFC21220uVCCC5100PC3100PD71N4004X2V12TIP36CR410R22R420R22C194700uFC10470pFC20220uVCCV14TIP36CV19TIP36CR430R22R450R22R460R22V17TIP36CV18TIP36CR470R22IC1ALM1458IC1BLM1458R710KR

50、24K7R510KR610K VCCR44K7C4100PC29.1uV7BC639V9BC639D101N5818CH1C25220uC2647uFV3BC639R291KR281KD4IN4004D3IN4004X1LK1R302K2LK2F110 S/BR3622R 2WB1B2T1CX2.22uCX122N/400VS1F23.15 A S/BC22.1uRS76532135VDC84AMIS 120 POWER AMPCD6338-22 of2TO 24VACX1/16+BAT TERMINALPOWER TRX1/15-12V41235678-12V47658-12VDCIC4LM

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 功放/音响/收扩 > AustralianMonitor

copyright@ 2008-2023 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号