1、D&M Holdings lnc.eSERVICE MANUALAV SURROUND RECEIVERAV SURROUND AMPLIFIERMODELJPEUECE2EKE2AE1CEUTAVR-4310CI?AVR-4310? ?MODELJPEUECE2EKE2AE1CEUTAVC-4310? ?sdVer. 6For purposes of improvement, specifications and design are subject to change without notice.Please use this service manual with referring

2、to the operating instructions without fail.Some illustrations using in this service manual are slightly different from the actual set.S0025-1V06DM/DG0912Please refer to theMODIFICATION NOTICE.RadioFans.CN 收音机爱 好者资料库2AVR-4310CI/AVR-4310/AVC-4310Please heed the points listed below during servicing and

3、 inspection.Heed the cautions!Spots requiring particular attention when servicing, suchas the cabinet, parts, chassis, etc., have cautions indicatedon labels or seals. Be sure to heed these cautions and thecautions indicated in the handling instructions.Caution concerning electric shock!(1) An AC vo

4、ltage is impressed on this set, so touching in-ternal metal parts when the set is energized couldcause electric shock. Take care to avoid electric shock,by for example using an isolating transformer andgloves when servicing while the set is energized, un-plugging the power cord when replacing parts,

5、 etc.(2)There are high voltage parts inside. Handle with extracare when the set is energized.Caution concerning disassembly andassembly!Though great care is taken when manufacturing parts fromsheet metal, there may in some rare cases be burrs on theedges of parts which could cause injury if fingers

6、aremoved across them. Use gloves to protect your hands.Only use designated parts!The sets parts have specific safety properties (fire resis-tance, voltage resistance, etc.). For replacement parts, besure to use parts which have the same properties. In par-ticular, for the important safety parts that

7、 are marked z onwiring diagrams and parts lists, be sure to use the desig-nated parts.Be sure to mount parts and arrangethe wires as they were originally!For safety reasons, some parts use tape, tubes or other in-sulating materials, and some parts are mounted away fromthe surface of printed circuit

8、boards. Care is also taken withthe positions of the wires inside and clamps are used tokeep wires away from heating and high voltage parts, sobe sure to set everything back as it was originally.Inspect for safety after servicing!Check that all screws, parts and wires removed or discon-nected for ser

9、vicing have been put back in their original po-sitions, inspect that no parts around the area that has beenserviced have been negatively affected, conduct an insu-lation check on the external metal connectors and betweenthe blades of the power plug, and otherwise check thatsafety is ensured.(Insulat

10、ion check procedure)Unplug the power cord from the power outlet, disconnectthe antenna, plugs, etc., and turn the power switch on. Us-ing a 500V insulation resistance tester, check that the in-sulation resistance between the terminals of the powerplug and the externally exposed metal parts (antenna

11、ter-minal, headphones terminal, microphone terminal, inputterminal, etc.) is 1M or greater. If it is less, the set mustbe inspected and repaired.Concerning important safetypartsMany of the electric and structural parts used in the sethave special safety properties. In most cases these prop-erties ar

12、e difficult to distinguish by sight, and using re-placement parts with higher ratings (rated power andwithstand voltage) does not necessarily guarantee thatsafety performance will be preserved. Parts with safetyproperties are indicated as shown below on the wiring dia-grams and parts lists is this s

13、ervice manual. Be sure to re-place them with parts with the designated part number.(1) Schematic diagrams . Indicated by the z mark.(2) Parts lists . Indicated by the z mark.Using parts other than the designatedparts could result in electric shock, fires orother dangerous situations.SAFETY PRECAUTIO

14、NSThe following check should be performed for the continued protection of the customer and service technician.LEAKAGE CURRENT CHECKBefore returning the unit to the customer, make sure you make either (1) a leakage current check or (2) a line to chassisresistance check. If the leakage current exceeds

15、 0.5 milliamps, or if the resistance from chassis to either side of thepower cord is less than 460 kohms, the unit is defective.CAUTIONCAUTIONRadioFans.CN 收音机爱 好者资料库3AVR-4310CI/AVR-4310/AVC-4310DIMENSIONAVR-4310CI/AVR-4310/AVC-431034443415515.5170.520.7244.5372.820.541454.74AVR-4310CI/AVR-4310/AVC-4

16、310WIRE ARRANGEMENTIf wire bundles are untied or moved to perform adjustment or parts replacement etc., be sure to rearrange them neatly as they were originally bundled or placed afterward.Otherwise, incorrect arrangement can be a cause of noise generation.Wire arrangement viewed from the topFront P

17、anel sideBack Panel side5AVR-4310CI/AVR-4310/AVC-4310CAUTION IN SERVICINGBefore the Digital P.W.B. are replacedIf you cannot specify the cause of the digital PWB defect, carry out Initializing Update to latest firmware. The defect may be cleared. See the following for the method of initializing the

18、com.Initializing AV SURROUND RECEIVERAV SURROUND RECEIVER initialization should be performed when the com, peripheral parts of com, and Digital P.W.B. are replaced.1. Switch off the unit.2. Hold the following STANDARD button and DSP SIMULATION button, and switch on the unit.3. Check that the entire

19、display is flashing with an interval of about 1 second, and release your fingers from the 2 buttons and the microprocessor will be initialized.Note:If step 3 does not work, start over from step 1. All user settings will be lost and this factory setting will be recovered when this initialization mode

20、.So make sure to memorize your setting for restoring after the initialization.JIG to use for servicingWhen you repair the printing board, you can use the following JIG. Please order to Denon Official Service Distributor in your region if necessary.Extention cable kit00D SPK- 561 EXTENSION UNIT KIT :

21、 1 Set00D SPK- 562 TUCP CONN. JOINT KIT : 1 SetExtention cable for Idling CurrentParts Number for Extension Cables and Quantity of Unit. How to use and Adjust Idle Current.1. The thin and hard plate (ex. Ruler) is fixed with the tape behind the cable. 2. The voltmeter is connected with the other sid

22、e of the extension cable.3. Refer to ADJUSTMENT(Idling Current).Parts NumberParts NameQty / unitRemarks612050082004D6P 250mm NH1L=250mm 6P NH Cable612050083007D8P 250mm NH1L=250mm 8P NH Cable1,22,36AVR-4310CI/AVR-4310/AVC-4310DISASSEMBLY Disassemble in order of the arrow of the figure of following f

23、low. In the case of the re-assembling, assemble it in order of the reverse of the following flow. In the case of the re-assembling, observe attention of assembling it.TOP COVERBACK PANEL UNIT ASSYFRONT PANEL UNIT ASSYRefer to DISASSEMBLYREG UNITRefer to DISASSEMBLY2. BACKPANEL UNIT ASSYRefer to DISA

24、SSEMBLY1.FRONT PANEL UNIT ASSY5. REG UNITP.SW UNITand EXPLODED VIEW (Ref. No. of EXPLODED VIEW : A-8)DIGITAL UNIT ASSYREG UNIT FRONT HDMI UNITRefer to DISASSEMBLY (Ref. No. of EXPLODED VIEW : B-4) (Ref. No. of EXPLODED VIEW : E-4)3. DIGITAL UNIT ASSYREG CONNECT-1 UNITFRONT USB UNITand EXPLODED VIEW

25、(Ref. No. of EXPLODED VIEW : A-15) (Ref. No. of EXPLODED VIEW : E-3)DIGITAL UNIT CONNECT UNIT-2MIC UNIT (Ref. No. of EXPLODED VIEW : G) (Ref. No. of EXPLODED VIEW : D-4) (Ref. No. of EXPLODED VIEW : A-9)FRONT IN UNIT (Ref. No. of EXPLODED VIEW : A-10)A.VIDEO UNIT, AUDIO UNIT AMP UNITVR CONNECT UNITa

26、nd RADIATOR UNIT ASSYRefer to DISASSEMBLY (Ref. No. of EXPLODED VIEW : A-5)Refer to DISASSEMBLY6. AMP UNITVOLUME UNIT4. A.VIDEO UNIT, AUDIO UNITand EXPLODED VIEW (Ref. No. of EXPLODED VIEW : A-4)and RADIATOR UNIT ASSYAMP UNITFUNC CONNECT UNITand EXPLODED VIEW (Ref. No. of EXPLODED VIEW : D-1) (Ref.

27、No. of EXPLODED VIEW : A-7)A.VIDEO UNITFUNC UNIT (Ref. No. of EXPLODED VIEW : E-1) (Ref. No. of EXPLODED VIEW : A-6)AUDIO UNITP.AMP JOINT UNITFLD UNIT (Ref. No. of EXPLODED VIEW : E-2)Refer to DISASSEMBLY (Ref. No. of EXPLODED VIEW : A-1)MAIN CPU UNIT7. P.AMP JOINT UNIT (Ref. No. of EXPLODED VIEW :

28、F)and EXPLODED VIEWREMOTE/IPOD UNITP.AMP JOINT UNIT (Ref. No. of EXPLODED VIEW : B-5) (Ref. No. of EXPLODED VIEW : D-2)232C UNIT (Ref. No. of EXPLODED VIEW : B-6)P.AMP UNITRefer to DISASSEMBLY9.P.AMP UNITand EXPLODED VIEWP.AMP UNIT (Ref. No. of EXPLODED VIEW : D-17)7AVR-4310CI/AVR-4310/AVC-4310About

29、 the photos used for descriptions in the “DISASSEMBLY” section. The direction from which the photographs used herein were photographed is indicated at Direction of photograph: * at the left of the respective photographs. Refer to the table below for a description of the direction in which the photos

30、 were taken. Photographs for which no direction is indicated were taken from above the product.1. FRONT PANEL UNIT ASSY(1) Remove the screws.(2) Cut the wire clampers then disconnect the connector wires. Front sideDirection of photograph: BDirection of photograph: DDirection of photograph: CDirectio

31、n of photograph: AThe viewpoint of each photograph(Photografy direction)View from aboveProceeding:TOP COVER FRONT PANEL UNIT ASSYView from bottomCX021CY062Direction of photograph: Dcutcutcut8AVR-4310CI/AVR-4310/AVC-4310(3) Remove the FFC cover and acetate tapes. Disconnect the FFC Cables.(4) Remove

32、the screws.Attention of assemblingWhen mounting the FRONT PANEL ASSY on the CHASSIS, do so with the DOOR open so as to prevent breaking the EARTH PLATE(DOOR).If the FRONT PANEL ASSY is mounted on the chassis with the DOOR closed, the EARTH PLATE(DOOR) willhit the CHASSIS and break.Acetate tapeFFC Co

33、verFFC CableDirection of photograph: CFFC Cable?Please refer to EXPLODED VIEW for the disassembly method of each P.W.B included in FRONT PANEL ASSY.DOOR openDOOR closed (EARTH PLATE (DOOR) will be broken.)EARTH PLATE (DOOR)DOORDOOREARTH PLATE (DOOR)Direction of photograph: ADirection of photograph:

34、A9AVR-4310CI/AVR-4310/AVC-43102. BACK PANEL UNIT ASSY(1) Remove the Sheets, then remove the screws.(2) Remove the screws.(3) Disconnect the connector wires and FFC Cable, then remove the screws. Proceeding:TOP COVER BACK PANEL UNIT ASSYSheetsView from bottom?Direction of photograph: ACY153CY101CX055

35、CX074FFC CableCY05210AVR-4310CI/AVR-4310/AVC-4310(4) Remove the FFC cover, PWB HOLDER and acetate tapes. Cut the wire clamper, then disconnect the connector wire and FFC Cable.(5) Cut the wire clamper, then disconnect the connector wire.FFC CableCX068PWB HOLDERDirection of photograph: CcutAcetate ta

36、peAcetate tapeFFC CovervDirection of photograph: DBACK PANEL UNIT ASSYCX091cut11AVR-4310CI/AVR-4310/AVC-43103. DIGITAL UNIT ASSY (1) Remove the alminium tape, then cut the wire clampers. Disconnect the connector wire, FFC Cables, and board to board.(2) Remove the screws.Proceeding:TOP COVER BACK PAN

37、EL UNIT ASSYDIGITAL UNIT ASSYFFC CableFFC CableFFC CablecutcutMAIN CPU UNITDIGTAL UNIT ASSYBoard to boardCX058CX124CX047CY061Alminium TapeCY124?Direction of photograph: A12AVR-4310CI/AVR-4310/AVC-43104. A.VIDEO UNIT, AUDIO UNIT and RADIATOR UNIT ASSY(1) Disconnect the board to board.(2) Disconnect t

38、he connector wires.(3) Remove the screws.Proceeding:TOP COVER BACK PANEL UNIT ASSY A.VIDEO UNIT, AUDIO UNIT and RADIATOR UNIT ASSYDIGITAL UNIT ASSYvDirection of photograph: CMAIN CPU UNITCX073CX192Direction of photograph: AA.VIDEO UNITAUDIO UNITRADIATOR UNIT ASSY13AVR-4310CI/AVR-4310/AVC-43105. REG

39、UNIT (1) Disconnect the board to board and connector wires.(2) Disconnect the connector wires, then remove the screws.6. AMP UNIT(1) Disconnect the VH connector and conector.Proceeding:TOP COVER BACK PANEL UNIT ASSY A.VIDEO UNIT, AUDIO UNIT and RADIATOR UNIT ASSYDIGITAL UNIT ASSY REG UNITBoard to bo

40、ardDirection of photograph: ACX231CX092v?Direction of photograph: AProceeding:TOP COVER BACK PANEL UNIT ASSY A.VIDEO UNIT, AUDIO UNIT and RADIATOR UNIT ASSYDIGITAL UNIT ASSY REG UNIT AMP UNITCX851CX891CX876CX874CX871CX873CX872CX875CX877View from bottom14AVR-4310CI/AVR-4310/AVC-43107. P.AMP JOINT UNI

41、T(1) Disconnect the connector.8. P.AMP UNIT(1) Remove the screws. Proceeding:TOP COVER BACK PANEL UNIT ASSY A.VIDEO UNIT, AUDIO UNIT and RADIATOR UNIT ASSYDIGITAL UNIT ASSY REG UNIT AMP UNIT P.AMP JOINT UNITCX803CX805CX806CX811CX812CX807CX804Direction of photograph: AProceeding:TOP COVER BACK PANEL

42、UNIT ASSY A.VIDEO UNIT, AUDIO UNIT and RADIATOR UNIT ASSYDIGITAL UNIT ASSY REG UNIT AMP UNIT P.AMP JOINT UNIT P.AMP UNITDirection of photograph: B15AVR-4310CI/AVR-4310/AVC-4310SPECIAL MODESpecial mode setting button Press the ON/OFF button to turn on while pressing both buttons A and B at the same t

43、ime.*1 : About RS-232C communicationsRS-232C communications are not possible when is displayed on the FL display.Press and hold in the STATUS and buttons for over 3 seconds with the power turned on to turn the display off. RS-232C communications are now enabled.ModeButton AButton BcontentsVersion di

44、splay(com/DSP Error Display)STATUSRETURNSerial No. and firmware versions such as Main, Sub, DSP are displayed in the FL manager. Errors are displayed when they occur. (Refer to 16 page.)Displaying the protection history modeSTATUSMENUDisplaying the protection history(Refer to 18 page.)Initialization

45、 mode(Remove settings for Installer Setup.)STANDARDDSP SIMULATIONBackup data initialization is carried out.(Remove settings for Installer Setup.)Initialization mode(Includes settings for Installer Setup)CURSOR UPCURSOR DOWNBackup data initialization is carried out.(Includes settings for Installer Se

46、tup)Mode for switching tuner frequency stepSTANDARDDIRECT/STEREO-E2 model only-Change tuner frequency step to FM:200kHz/AM:10kHzSTEP. gMode for preventing remote control acceptanceSTATUSENTEROperations using remote control are rejected.(Mode cancellation: Turn off power and execute the same button o

47、perations as when performing setup.)Panel lock modeDSP SIMULATIONZONE2 Operations using main unit panel buttons or master volume are rejected.Panel lock mode(Remove Master volume)DIRECT/STEREOZONE2Operations using main unit panel buttons are rejected.Cancellation of panel lock modePURE DIRECTZONE2 P

48、anel lock mode is cancelled.Installer Setup mode*1MENUCURSOR LEFTAccess Remote Maintenance mode via the internet.Installer Setup is displayed on GUI/Option Menu.Refer to AVR4310_RemoteMaintenance_.pdf of SDI.ON/OFFRETURNZONE2DSP SIMULATIONSTANDARDSTATUSENTERPUREDIRECTDIRECT/STEREOMENUCURSOR16AVR-431

49、0CI/AVR-4310/AVC-43101. Version display (com/DSP Error Display)1.1. Operation Speccom version display mode:When the following conditions are satisfied at its starting state, error information is displayed before version information.Starting method (same as com version display):Press the ON/OFF butto

50、n to turn on while pressing both buttons STATUS and RETURN at the same time.(Error information is displayed after about 10 seconds.)The FL display changes in the order given in item-1.2. each time you press the STATUS button.1.2. Display OrderError information(Refer to 1.3. Error display) qModel des