《Denon-AVRS710W-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Denon-AVRS710W-avr-sm维修电路原理图.pdf(169页珍藏版)》请在收音机爱好者资料库上搜索。
1、MODELJPE3E2EKEAE1E1CE1KAVR-X1200WPPPPAVR-S710WPINTEGRATED NETWORK AV RECEIVERVer. 1 Please use this service manual with referring to the operating instructions without fail. Some illustrations using in this service manual are slightly different from the actual set. For purposes of improvement, speci
2、fications and design are subject to change without notice.eSERVICE MANUALeD&M Holdings Inc.RadioFans.CN 收音机爱 好者资料库ABOUT THIS MANUAL .3What you can do with this manual .3Using Adobe Reader (Windows version) .4SAFETY PRECAUTIONS .6NOTE FOR SCHEMATIC DIAGRAM .7NOTE FOR PARTS LIST .7INSTRUCTIONS FOR HAN
3、DLING SEMI-CONDUCTORS AND OPTICAL UNIT .71. Ground for Human Body .72. Ground for Workbench .7TECHNICAL SPECIFICATIONS for AVR-X1200W .9DIMENSION for AVR-X1200W .10TECHNICAL SPECIFICATIONS for AVR-S710W .11DIMENSION for AVR-S710W .12CAUTION IN SERVICING (AVR-X1200W) .13Initializing This Unit .13JIG
4、FOR SERVICING .13CAUTION IN SERVICING (AVR-S710W) .14Initializing This Unit .14JIG FOR SERVICING .14DISASSEMBLY .151. FRONT PANEL ASSY .172. DIGITAL PCB .173. RADIATOR ASSY .184. POWER PCB .185. REGULATOR PCB .186. TRANS POWER .18SPECIAL MODE .19Special mode setting button (for AVR-X1200W) .19Specia
5、l mode setting button (for AVR-S710W) .201. Version Display Mode .212. PANEL / REMOTE LOCK Selection Mode .253. Selecting the Mode for Service-related Operations .26 DIAGNOSTIC PATH DIAGRAM .294. Remote ID Setup Mode .485. Protection Pass Mode .496. CY920 Reboot Mode .497. CY920 Initialization Mode
6、.50JIG FOR SERVICING .51PROCEDURE AFTER REPLACING THE MICROPROCESSOR, ETC. .53FIRMWARE UPDATE PROCEDURE .541. Updating via USB .542. Updating via DPMS .63ADJUSTMENT .70SURROUND MODES AND PARAMETERS .71TROUBLE SHOOTING .741. POWER .742. Analog video .753. HDMI/DVI .764. AUDIO .785. Network/Bluetooth/
7、USB .816. SMPS .85CLOCK FLOW & WAVE FORM IN DIGITAL BLOCK .87LEVEL DIAGRAM .88BLOCK DIAGRAM .94POWER DIAGRAM .97WIRING DIAGRAM .98PRINTED CIRCUIT BOARDS .99SCHEMATIC DIAGRAMS (01/17).103SCH01_HDMI RX .103SCH02_HDMI TX .104SCH03_OSD.105SCH04_DIGITAL SUPPLY .106SCH05_MCU .107SCH06_MCU LEVEL CHG .108SC
8、H07_DIR, PLD .109SCH08_DSP .110SCH09_MAIN DAC .111SCH10_NETWORK .112SCH11_ALALOG .113SCH12_MAIN .114SCH13_FRONT HDMI .115SCH14_DIFF-AMP .116SCH15_FRONT .117SCH16_REGULATOR .118SCH17_SMPS .119EXPLODED VIEW .120PACKING VIEW .121SEMICONDUCTORS .1221. ICs .1222. FL DISPLAY .147CONTENTS2RadioFans.CN 收音机爱
9、 好者资料库Jump to the target of a schematic diagram connectorClick the Ref. No. of the target connector in the red box around a schematic diagram connector.The screen jumps to the target connector. Pagemagnificationstaysthesameasbeforethejump.CP401CP106vABOUT THIS MANUALReadthefollowinginformationbefore
10、usingtheservicemanual.What you can do with this manualSearch for a Ref. No. (phrase)(Ctrl+Shift+F)YoucanusethesearchfunctioninAcrobatReadertosearchforaRef.No.inschematicdiagrams,printedwiringcircuitdiagrams,blockdiagrams,andpartslists.1.PressCtrl+Shift+Fonthekeyboard.TheSearchwindowappears.2.Enterth
11、eRef.No.youwanttosearchforintheSearchwindow,andthenclicktheSearchbutton.Alistofsearchresultsappears.3.Clickanitemonthelist. Thescreenjumpstothepageforthatitem,andthesearchphraseisdisplayed.CtrlShiftF3Using Adobe Reader (Windows version) Properties Clickthisbuttonandcheckthattheprinterissettoasuitabl
12、epapersize. Page to print Selectthefollowingcheckbox.More Options:Current View Page Sizing & Handling Selectthefollowingcheckbox.Size/Size Options :FitAdd notes to this data (Sign)TheSignfunctionletsyouaddnotestothedatainthismanual.Savethefileonceyouhavefinishedaddingnotes.Example using Adobe Reader
13、 XOntheViewmenu,clickSign.TheSignpaneappears.Example using Adobe Reader 9Onthe Documentmenu,clickSign.Magnify schematic / printed circuit board diagrams - 1(Ctrl+Space, mouse operation)PressCtrl+Space onthekeyboardanddragthemousetoselecttheareayouwanttoview.Theselectedareaismagnified. Whenyouwanttom
14、ovetheareashown,holddownSpaceanddragthemouse. Whenyouwanttoshowafullpageview,pressCtrl+0onthekeyboard.CtrlSpace0Print a magnified part of the manualThePropertiesdialogboxandfunctionswillvarydependingonyourprinter.1.Dragthemousetomagnifythepartyouwanttoprint.2.OntheFilemenu,clickPrint.3.Configurethef
15、ollowingsettingsinthePrintdialogbox.4.ClickthePrintbuttontostartprinting.4Magnify schematic / printed circuit board diagrams - 2(Pan & Zoom function)ThePan&Zoomfunctionletsyouseewhichpartofamagnifieddiagramisbeingshowninaseparatewindow.Example using Adobe Reader XOntheViewmenu,pointtoZoom,andthencli
16、ckPan & Zoom.ThePan&Zoomwindowappearsonthescreen.Example using Adobe Reader 9OntheToolsmenu,pointto Select & Zoom,andthenclickPan & Zoom Window.Magnify schematic / printed circuit board diagrams - 3(Loupe Tool function)TheLoupeToolfunctionletsyoumagnifyaspecificpartofadiagraminaseparatewindow.Exampl
17、eusingAdobeReaderXOntheViewmenu,pointtoZoom,andthenclickLoupe Tool.TheLoupeToolwindowappearsonthescreen.Example using Adobe Reader 9OntheToolsmenu,pointtoSelect & Zoom,andthenclickLoupe Tool Window.5SAFETY PRECAUTIONSThe following items should be checked for continued protection of the customer and
18、the service technician.leakage current checkBefore returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is
19、 less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicable.CAUTION Please heed the following cautions and instructions during servicing and inspection
20、. Heed the cautions!Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the handling instructions. Cautions concerning electric shock!(1) An AC voltage is impressed on this s
21、et, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing while the set is energized, or by unplugging the power cord when replacing parts, for example.(2) Th
22、ere are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly!Through great care is taken when parts were manufactured from sheet metal, there may be burrs on the edges of parts. The burrs could cause injury if fingers are moved acro
23、ss them in some rare cases. Wear gloves to protect your hands. Use only designated parts!The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use parts which have the same properties for replacement. The burrs have the same properties. In particular,
24、 for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally placed!For safety seasons, some parts use tapes, tubes or other insulating materials, and
25、some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and high voltage parts, so be sure to set everything back as it was originally placed. Make a safety check afte
26、r servicing!Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area around. Then make an insulation check on the external metal connectors and between the blades of the power
27、plug, and otherwise check that safety is ensured.(Insulation check procedure)Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V insulation resistance tester, check that the insulation resistance value between the inplug and the externally
28、 exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired.Many of the electric and the structural parts used in the set have special safety properties. In most cases these properties are difficult to dis
29、tinguish by sight, and the use of replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety properties are indicated as shown below on the wiring diagrams and the parts list in this service ma
30、nual. Be sure to replace them with the parts which have the designated part number.(1) Schematic diagrams .Indicated by the z mark.(2) Parts lists .Indicated by the z mark.The use of parts other than the designated parts could cause electric shocks, fires or other dangerous situations.CAUTION Concer
31、ning important safety parts6NOTE FOR SCHEMATIC DIAGRAMWARNING:Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.CAUTION:Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a lin
32、e to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective.WARNING:DO NOT return the set to the customer unless the problem is identified and remedied.NOTICE:ALL RESISTAN
33、CE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHMALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNLESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO FARAD. EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.NOTE FOR PAR
34、TS LIST1. Parts indicated by nsp on this table cannot be supplied.2. When ordering a part, make a clear distinction between 1 and I (i) to avoid mis-supplying.3. A part ordered without specifying its part number can not be supplied. 4. Part indicated by mark is not illustrated in the exploded view.W
35、ARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.INSTRUCTIONS FOR HANDLING SEMI-CONDUCTORS AND OPTICAL UNITElectrostatic breakdown of the semi-conductors or optical pickup may occur due to a potential difference caused by
36、 electrostatic charge during unpacking or repair work.1. Ground for Human BodyBe sure to wear a grounding band (1 M) that is properly grounded to remove any static electricity that may be charged on the body.2. Ground for WorkbenchBe sure to place a conductive sheet or copper plate with proper groun
37、ding (1 M) on the workbench or other surface, where the semi-conductors are to be placed. Because the static electricity charge on clothing will not escape through the body grounding band, be careful to avoid contacting semi-conductors with your clothingCBAGrounding BandConductive Sheet orCopper Pla
38、te1M1MCBA78Personal notes:TECHNICAL SPECIFICATIONS FOR AVR-X1200W n Audio section Power amplifierRated output : Front : 80 W + 80 W ( 8 , 20 Hz - 20 kHz with 0.08 % T.H.D.)120 W + 120 W ( 6 , 1 kHz with 0.7 % T.H.D.)Center : 80 W ( 8 , 20 Hz - 20 kHz with 0.08 % T.H.D.)120 W ( 6 , 1 kHz with 0.7 % T
39、.H.D.)Surround : 80 W + 80 W ( 8 , 20 Hz - 20 kHz with 0.08 % T.H.D.)120 W + 120 W ( 6 , 1 kHz with 0.7 % T.H.D.)Surround back : 80 W + 80 W ( 8 , 20 Hz - 20 kHz with 0.08 % T.H.D.)120 W + 120 W ( 6 , 1 kHz with 0.7 % T.H.D.)Output connectors : 4 - 16 n Analog sectionInput sensitivity/Input impedanc
40、e : 200 mV / 47 kFrequency response : 10 Hz - 100 kHz +1, -3 dB (Direct mode)S/N ratio : 98 dB (IHF-A, Direct mode) n Video section Color component video connectorInput/output level and impedance : 1 Vp-p, 75 Frequency response : 5 Hz - 10 MHz 0, 3 dB n Tuner section (Note : V at 75 , 0 dBf = 1 x 10
41、 15 W)Reception frequency range : FM 87.5 MHz - 107.9 MHz (for E3) FM 87.5 MHz - 108.0 MHz (for E2, E1C) FM 76.0 MHz - 95.0 MHz (for JP) AM 520 kHz - 1710 kHz (for E3) AM 522 kHz - 1611 kHz (for E2, E1C) AM 522 kHz - 1629 kHz (for JP)Effective sensitivity : FM 1.2 V (12.8 dBf) AM 18 V50 dB sensitivi
42、ty : MONO 2.8 V (20.2 dBf)S/N ratio : MONO 70 dB (IHFA weighted, Direct mode) STEREO 67 dB (IHFA weighted, Direct mode) Distortion : MONO 0.7 % (1 kHz) SRETEO 1.0 % (1 kHz) n Wireless LAN sectionNetwork type (wireless LAN standard) : Conforming to IEEE 802.11b Conforming to IEEE 802.11g Conforming t
43、o IEEE 802.11n (Wi-Fi compliant)z1Security : WEP 64 bit, WEP 128 bit WPA/WPA2-PSK (AES) WPA/WPA2-PSK (TKIP)Radio frequency : 2.4 GHzNo. of channels : 1 - 11 ch (for E3) 1 - 13 ch (for E2, E1C, JP)z1 The Wi-Fi CERTIFIED Logo and the Wi-Fi CERTIFIED On-Product Logo are registered trademarks of the Wi-
44、Fi Alliance. n Bluetooth sectionCommunications system : Bluetooth Version 2.1 + EDR (Enhanced Data Rate)Transmission power : Maximum 2.5 mW (Class 2)Maximum communication range : Approx. 32.8 ft/10 m in line of sightz2Frequency band : 2.4 GHz bandModulation scheme : FHSS (Frequency-Hopping Spread Sp
45、ectrum)Supported profiles : A2DP (Advanced Audio Distribution Profile)1.2 AVRCP (Audio Video Remote Control Profile)1.4Corresponding codec : SBC, AACTransmission range (A2DP) : 20 Hz - 20,000 Hzz2 The actual communication range varies depending on the influence of such factors as obstructions betwee
46、n devices, electromagnetic waves from microwave ovens, static electricity, cordless phones, reception sensitivity, antenna performance, operating system, application software etc. n GeneralPower supply : (for E3) : AC 120 V, 60 Hz (for E2) : AC 230 V, 50 Hz / 60 Hz (for E1C) : AC 220 V, 50 Hz (for J
47、P) : AC 100 V, 50 Hz / 60 HzPower consumption : 430 WPower consumption in standby mode : 0.1 WPower consumption in CEC standby mode : 0.5 WPower consumption in network standby mode : 2.7 WFor purposes of improvement, specifications and design are subject to change without notice.917 1/16 (434)13 9/1
48、6 (344)1 3/4 (45)2 3/8 (60)1 3/4 (45)9/16 (15)5 3/8 (136)5 15/16 (151)8 7/16 (215)11 5/16 (288)13 3/8 (339)3/4(19)1 1/4(32)7 3/4 (197)1 3/4 (44)1 7/8(47)DIMENSION FOR AVR-X1200WUnit : in. (mm)Weight : 18 lbs 12 oz (8.5 kg)10TECHNICAL SPECIFICATIONS FOR AVR-S710W n Audio section Power amplifierRated
49、output : Front : 75 W + 75 W ( 8 , 20 Hz - 20 kHz with 0.08 % T.H.D.)110 W + 110 W ( 6 , 1 kHz with 0.7 % T.H.D.)Center : 75 W ( 8 , 20 Hz - 20 kHz with 0.08 % T.H.D.)110 W ( 6 , 1 kHz with 0.7 % T.H.D.)Surround : 75 W + 75 W ( 8 , 20 Hz - 20 kHz with 0.08 % T.H.D.)110 W + 110 W ( 6 , 1 kHz with 0.7
50、 % T.H.D.)Surround back : 75 W + 75 W ( 8 , 20 Hz - 20 kHz with 0.08 % T.H.D.)110 W + 110 W ( 6 , 1 kHz with 0.7 % T.H.D.)Output connectors : 4 - 16 n Analog sectionInput sensitivity/Input impedance : 200 mV / 47 kFrequency response : 10 Hz - 100 kHz +1, -3 dB (Direct mode)S/N ratio : 98 dB (IHF-A,