1、Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19)Date:30-June-2003Model: SR4300,SR4400Page:1 / 1REF.NBR:MZ03-023Circulation:Application:Subject:Int.ref:PHENOMENONWhen the playback CD-R/RW of Digital that SCMS(Serial Copy Management System) signal was recorded,The so

2、und is interruptedSOLUTIONReplace MICRO PROCESSOR(Flash) ICS18 on the DIGITAL/AUDIO PCB.NECESSARY PART1. SR4300 POS.NO ICS18 Part no. *HS09AWH0R New version no: VER .030527 (H8/3026F Flash Ver.030527 wrote FACTORY PART No. OICH83026F43SV0527) OLD part no. *HU100620R FACTORY PART No. OICH83026F2. SR4

3、400 POS.NO ICS18 Part no. *HS26AWH0R New version no: VER .030515 (HD6433026D04F Mask Ver.030515 FACTORY PART No. OICHD6433026D04F) OLD part no. *HU100620R FACTORY PART No. OICH83026FVersion no can be confirmed with SERVICE MODE, Refer to service manual of SR4300 page56 orSR4400 page52.REMARKSThe cou

4、ntermeasure apply to this claim only.This improvement has been done in the productionthe serial no.XE000323xxxxxx and after (SR4300)the serial no.XE000322xxxxxx and after (SR4400/N1B/N1S)SR4400/A1B/A1S/K1S/K1G/U1B have used New MICRO PROCESSOR.Therefore, this problem doesnt occur.SERVICE BULLETIN Th

5、e sound is interrupted, when the playback DIGITAL of CD-R/RW of the SCMS signal.x for information customercomplaint in case of servicemandatory. See BelowRadioFans.CN 收音机爱 好者资料库Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19)Date:31-Oct.-2003Model: SR4300/SR4400Pag

6、e:1 / 3REF.NBR:MZ03-047Circulation:Application:Subject:Int.ref:PHENOMENON1) The protection circuit does not work when the power transistor was damaged.2) When the power transistor was damaged, about 40 V outputs to speaker out.3) The protection circuit function does not operate, then the unit will n

7、ot be in POWER STANDBY mode and the speaker output RELAY does not work.REASON 1) When the transistor is damaged before turn on the unit, the micro processor can not detect protection signal (Protect2).2) Turn on the unit, the down edge of a protection signal (Protect2) is undetectable for about 2 se

8、conds after the micro processor resetSOLUTIONThe protection output signal of Protection IC is added to the SPK MUTE signal in hard, andSpeaker MUTE is always set to “ON” when abnormal occur protection 1.SR4300 DIGITAL/AUDIO PCB1) Chip Resistor LS850 (100 ohm 1/16W part no. NN05101610 ) is changed to

9、 Silicon Diode(Part no. *HD201810R- 1SS400 POHM: EMD2, EIAJ: SC-79, JEDEC: SOD-523 ).MAIN PCB2) Chip Resistor DN601(Part no.HD20002000-Silicon Diode 1SS254 ROHM) is added between BASE of QN606 SEMICOM.COMP and No.5 pin of JFN101 Connector2.SR4400 DIGITAL/AUDIO PCB1) Chip Resistor RS928 (100 ohm 1/16

10、W part no. NN05101610 ) is changed to Silicon Diode(Part no. *HD201810R- 1SS400 POHM: EMD2, EIAJ: SC-79, JEDEC: SOD-523 ).MAIN PCB2) Chip Resistor DN601(Part no.HD20002000-Silicon Diode 1SS254 ROHM) is added between BASE of QN606 SEMICOM.COMP and No.5 pin of JFN101 ConnectorAs for the details, Pleas

11、e see page2/3 and 3/3REMARKSThe countermeasure apply to this claim only.This problem apply to the Service code number XE00 xxxxxxxxxx.This improvement has been done in the production the Service code number XE01xxxxxxxxx and after.SERVICE BULLETIN The problem of the Speaker protection circuit.x for

12、information customercomplaint in case of servicemandatory.Service code XE00XE00 xxxxxxxxxxRadioFans.CN 收音机爱 好者资料库Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19)SR4300/SR4400 SERVICE BULLETIN (REF.NBR:MZ03-047) page2/3 SR4300LS850 is changed toPart no. *HD201810RCa

13、utionJFS08 (FPC CONNECTOR) side isCATHODEDIGITAL/AUDIO PCBNo.5 pin of JFN101BASE of QN606Adhesives:SC608LVZ (Sony Chemical Corp. Self-extinguishing adhesive) or the equivalentInsulation tube is usedMAIN PCBDN601Part no. HD20002000CATHODE MARKApproved by S.NAGAO Written by WQ-19 2 817/additional rule

14、 3 (1st Issue 2003-03-19)SR4300/SR4400 SERVICE BULLETIN (REF.NBR:MZ03-047) page3/3 SR4400CATHODE MARKRS928 is changed toPart no. *HD201810RCautionJFS08 (FPC CONNECTOR) side isCATHODEDIGITAL/AUDIO PCBNo.5 pin of JFN101BASE of QN606Adhesives:SC608LVZ (Sony Chemical Corp. Self-extinguishing adhesive) o

15、r the equivalentInsulation tube is usedMAIN PCBDN601Part no. HD20002000Approved by S.NAGAO Written by WQ-19 2 817/additional rule 3 (1st Issue 2003-03-19)Date:30-June-2003Model: SR4300,SR4400Page:1 / 1REF.NBR:MZ03-025Circulation:Application:Subject:Int.ref:PHENOMENONThe problem occurs in the followi

16、ng operation.1. First, RDS(Radio Data System) in the FM signal is received.2. Then preset memory newly.3. Then press the POWER button on the remote controller , the unit became Standby mode.4. Again, press the POWER button on the remote controller, the volume level becomes “ - ” and Frequency indica

17、tion becomes the setup of default.(This problem occurs only SR4300/N1B/N1G/A1B/A1G and SR4400/N1B/N1S/A1B/A1S)SOLUTIONReplace MICRO PROCESSOR(Flash) ICS18 on the DIGITAL/AUDIO PCB.NECESSARY PART1. SR4300 POS.NO ICS18 Part no. *HS09AWH0R New version no: VER .030527 (H8/3026F Flash Ver.030527 wrote FA

18、CTORY PART No. OICH83026F43SV0527) OLD part no. *HU100620R FACTORY PART No. OICH83026F2. SR4400 POS.NO ICS18 Part no. *HS26AWH0R New version no: VER .030515 (HD6433026D04F Mask Ver.030515 FACTORY PART No. OICHD6433026D04F) OLD part no. *HU100620R FACTORY PART No. OICH83026FVersion no can be confirme

19、d with SERVICE MODE, Refer to service manual of SR4300 page56 orSR4400 page52.REMARKS1. The countermeasure apply to this claim only.2. This improvement has been done in the production the serial no.XE000322xxxxxx and after (SR4400)3. The production of SR4300/N1B/N1G/A1B/A1G has been finished.SERVICE BULLETIN FM(with RDS) signal is received, Frequency Indication becomes the setup of default by the remote control operation . (only N and A version occurs)x for information customercomplaint in case of servicemandatory. See Below