Marantz-SR7005-avr-sm 维修电路原理图.pdf

上传人:cc518 文档编号:147764 上传时间:2022-07-06 格式:PDF 页数:205 大小:22.52MB
下载 相关 举报
Marantz-SR7005-avr-sm 维修电路原理图.pdf_第1页
第1页 / 共205页
Marantz-SR7005-avr-sm 维修电路原理图.pdf_第2页
第2页 / 共205页
Marantz-SR7005-avr-sm 维修电路原理图.pdf_第3页
第3页 / 共205页
亲,该文档总共205页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Marantz-SR7005-avr-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Marantz-SR7005-avr-sm 维修电路原理图.pdf(205页珍藏版)》请在收音机爱好者资料库上搜索。

1、ServiceManual Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purposes of improvement, specifi cations and design are subject to change without notice.AV Surround

2、 ReceiverSR7005 /N1SG/N1B/U1B/K1BsSR7005SR7005S00114-1V02DM/DG1009Copyright 2010 D&M Holdings Inc. All rights reserved.WARNING: Violators will be prosecuted to the maximum extent possible.Ver. 2Please refer to the MODIFICATION NOTICE.2MARANTZ DESIGN AND SERVICEUsing superior design and selected high

3、 grade components, MARANTZ company has created the ultimate in stereo sound.Only original MARANTZ parts can insure that your MARANTZ product will continue to perform to the specifi cations for which it is famous. Parts for your MARANTZ equipment are generally available to our National Marantz Subsid

4、iary or Agent. ORDERING PARTS : Parts can be ordered either by mail or by Fax. In both cases, the correct part number has to be specifi ed. The following information must be supplied to eliminate delays in processing your order : 1. Complete address 2. Complete part numbers and quantities required 3

5、. Description of parts 4. Model number for which part is required 5. Way of shipment 6. Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void.In case of diffi culties, do not hesitate to contact the Technical Department at above mentioned ad

6、dress. 091105DM/DGUSAMARANTZ AMERICA, INC100 CORPORATE DRIVEMAHWAH, NEW JERSEY 07430USAEUROPE / TRADING D&M EUROPE B. V. P. O. BOX 8744, BUILDING SILVERPOINTBEEMDSTRAAT 11, 5653 MA EINDHOVENTHE NETHERLANDSPHONE : +31 - 40 - 2507844FAX : +31 - 40 - 2507860KOREAD&M SALES AND MARKETING KOREA LTD.2F,YEO

7、N BLDG.,88-5, BANPO-DONG, SEOCHO-GU,SEOUL KOREAPHONE : +82 - 2 - 715 - 9041FAX : +82 - 2 - 715 - 9040CANADAD&M Canada Inc.5-505 APPLE CREEK BLVD. MARKHAM, ONTARIO L3R 5B1CANADAPHONE : 905 - 415 - 9292FAX : 905 - 475 - 4159JAPAND&M BUILDING, 2-1 NISSHIN-CHO,KAWASAKI-KU, KAWASAKI-SHI,KANAGAWA, 210-856

8、9 JAPAND&M Holdings Inc.CHINAD&M SALES AND MARKETING SHANGHAI LTD.ROOM.808 SHANGHAI AIRPORT CITY TERMINAL NO.1600 NANJING (WEST) ROAD, SHANGHAI, CHINA. 200040TEL : 021 - 6248 - 5151FAX : 021 - 6248 - 4434SHOCK, FIRE HAZARD SERVICE TEST : CAUTION : After servicing this appliance and prior to returnin

9、g to customer, measure the resistance between either primary AC cord connector pins (with unit NOT connected to AC mains and its Power switch ON), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms should cause unit to be repaired o

10、r corrected before AC power is applied, and verifi ed before it is return to the user/customer. Ref. UL Standard No. 60065.NOTE ON SAFETY :Symbol z Fire or electrical shock hazard. Only original parts should be used to replaced any part marked with symbol z . Any other component substitution (other

11、than original type), may increase risk of fi re or electrical shock hazard.安全上注意:z部品、安全上重要部品。必指定部品番号部品使用下。3SAFETY PRECAUTIONSThe following check should be performed for the continued protection of the customer and service technician.LEAKAGE CURRENT CHECKBefore returning the unit to the customer, mak

12、e sure you make either (1) a leakage current check or (2) a line to chassis resistance check. if the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective.Be sure to test for leakage current with the AC

13、 plug in both polarities, in addition, in each power ON, OFF and STANDBY mode, if applicable.CAUTION Please heed the points listed below during servicing and inspection. Heed the cautions!Spots requiring particular attention when servicing, such as the cabinet, parts, chassis,etc., have cautions ind

14、icated on labels. be sure to heed these causions and the cautions indicated in the handling instructions. Caution concerning electric shock!(1) An AC voltage is impressed on this set, so touching internal metal parts when the set is energized could cause electric shock. Take care to avoid electric s

15、hock, by for example using an isolating transformer and gloves when servicing while the set is energized, unplugging the power cord when replacing parts, etc.(2) Tere are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly!Through

16、great care is taken when manufacturing parts from sheet metal, there may in some rare cases be burrs on the edges of parts which could cause injury if fi ngers are moved across them. Use gloves to protect your hands. Only use designated parts!The sets parts have specific safety properties (fire resi

17、stance, voltage resistance, etc.). For replacement parts, be sure to use parts which have the same poroperties. In particular, for the important safety parts that are marked z on wiring diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as the

18、y were originally!For safety seasons, some parts use tape, tubes or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wores omsode amd clamps are used to keep wires away from heating and high voltage p

19、arts, so be sure to set everything back as it was originally. Inspect for safety after servicing!Check that all screws, parts and wires removed or disconnected for servicing have been put back in their original positions, inspect that no parts around the area that has been serviced have been negativ

20、ely affected, conduct an inslation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured.(Insulation check procedure)Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and turn the power switch on. U

21、sing a 500V insulation resistance tester, check that the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired.Many of the electric and structural parts used in the set have

22、special safety properties. In most cases these properties are difficult to distinguish by sight, and using replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be poreserved. Parts with safety properties are indicated a

23、s shown below on the wiring diagrams and parts lists is this service manual. Be sure to replace them with parts with the designated part number.(1) Schematic diagrams .Indicated by the z mark.(2) Parts lists .Indicated by the z mark.Using parts other than the designated parts could result in electri

24、c shock, fi res or other dangerous situations.CAUTION Concerning important safety parts4NOTE FOR SCHEMATIC DIAGRAMWARNING:Parts marked with this symbol z have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.CAUTION:Before returning the unit to the customer, make

25、sure you make either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective.WARNING:DO NOT return the unit to the customer un

26、til the problem is located and corrected.NOTICE:ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHMALL CAPACITANCE VALUES IN MICRO FARAD. P=MICRO-MICRO FARAD EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.Parts

27、 for which nsp is indicated on this table cannot be supplied.When ordering of part, clearly indicate 1 and I (i) to avoid mis-supplying.Ordering part without stating its part number can not be supplied. Not including General-purpose Carbon Chip Resistor in the P.W.Board parts list. (Refer to the Sch

28、ematic Diagram for those parts.)Parts marked with this symbol z have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.Not including General-purpose Carbon Film Resistor in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.)Part indicated wi

29、th the mark is not illustrated in the exploded view.WARNING:1.2.3.4.5.6.ResistorsRD:CarbonRC:CompositionRS :Metal oxide filmRW:windingRN:Metal filmRK :Metal mixtureP:Pulse-resistant typeNL :Low noise typeNB :Non-burning typeFR :Fuse-resistorF:Lead wire forming2B :1/8 W2E :1/4 W2H :1/2 W3A :1 W3D :2

30、W3F :3 W3H :5 WF:1%G:2%J:5%K:10%M :20%Ex.:RNType14KShapeand per-formance2EPower182Resist-anceGAllowableerrorFROthers* Resistance1800ohm=1.8kohm1 82Indicates number of zeros after effective number.2-digit effective number.1.2ohm1 R22-digit effective number, decimal point indicated by R.1-digit effect

31、ive number.: Units: ohmCapacitorsCE :Aluminum foilelectrolyticCA :Aluminium solidelectrolyticCS :Tantalum electrolyticCQ:FilmCK :CeramicCC:CeramicCP :OilCM:MicaCF :MetallizedCH:MetallizedHS :High stability typeBP :Non-polar typeHR:Ripple-resistant typeDL :For change and dischargeHF :For assuring hig

32、h requencyU:UL partC:CSA partW :UL-CSA partF:Lead wire forming0J :6.3 V1A :10 V1C :16 V1E :25 V1V :35 V1H :50 V2A :100 V2B :125 V2C :160 V2D :200 V2E :250 V2H :500 V2J :630 VF:1%G:2%J:5%K:10%M :20%Z:80%:- 20%P:+100%C:0.25pFD:0.5pF=:OthersEx.:CEType04WShapeand per-formance1HDielectricstrength3R2Capac

33、ityMAllowableerrorBPOthers Units:F.2200F2 22Indicates number of zeros after effective number.2-digit effective number. Units:F.2.2F2 R22-digit effective number, decimal point indicated by R1-digit effective number.*Capacity (electrolyte only)When the dielectric strength is indicated in AC,AC is incl

34、uded after the dieelectric strength value.*Capacity (except electrolyte) Units:pF2200pF=0.0022F2 22Indicates number of zeros after efective number. (More than 2)2-digit effective number. Units:pF220pF2 212-digit effective number.Indicates number of zeros after effective numver. (0 or 1)NOTE FOR PART

35、S LIST5TECHNICAL SPECIFICATIONS n Audio Section Power amplifi erRated output :Front :125 W + 125 W (8 , 20 Hz 20 kHz with 0.08 % T.H.D.)Center :125 W (8 , 20 Hz 20 kHz with 0.08 % T.H.D.)Surround :125 W + 125 W (8 , 20 Hz 20 kHz with 0.08 % T.H.D.)Surround back / Front height / Front wide:125 W + 12

36、5 W (8 , 20 Hz 20 kHz with 0.08 % T.H.D.)Maximum effective output power :Front :195 W + 195 W (6 , 1 kHz with 10 % T.H.D.)Center :195 W (6 , 1 kHz with 10 % T.H.D.)Surround :195 W + 195 W (6 , 1 kHz with 10 % T.H.D.)Surround back / Front height / Front wide:195 W + 195 W (6 , 1 kHz with 10 % T.H.D.)

37、Output connectors : 6 8 AnalogInput sensitivity/Input impedance : 200 mV/47 kFrequency response : 10 Hz 100 kHz +1, 3 dB (DIRECT mode) S/N : 96 dB (IHFA weighted, DIRECT mode)Distortion : 0.008 % (20 Hz 20 kHz) (DIRECT mode)Rated output : 1.2 V DigitalD/A output : Rated output 2 V (at 0 dB playback)

38、 Total harmonic distortion 0.008 % (1 kHz, at 0 dB) S/N ratio 102 dB Dynamic range 100 dBDigital input : Format Digital audio interface Phono equalizer (PHONO input REC OUT)Input sensitivity : 2.5 mVRIAA deviation : 1 dB (20 Hz to 20 kHz) S/N : 96 dB (IHFA weighted, DIRECT mode)Distortion : 74 dB (A

39、 weighting, with 5 mV input)Rated output : 150 mVDistortion factor : 0.03 % (1 kHz, 3 V) n Video Section Standard video connectorsInput/output level and impedance : 1 Vp-p, 75 Frequency response : 5 Hz 10 MHz +1, 3 dB Color component video connectorInput/output level and impedance:Y (brightness) sig

40、nal 1 Vp-p, 75 PB / CB signal 0.7 Vp-p, 75 PR / CR signal 0.7 Vp-p, 75 Frequency response :5 Hz 60 MHz +0, 3 dB (when “Video Convert” set to “OFF”) n HD Radio section (for U)FM(Note: V at 75 , 0 dBf = 1 x 1015 W)Receiving Range :FM 87.5 MHz 107.9 MHz AM530 kHz 1710 kHzUsable Sensitivity :FM1.5 V (14

41、.8 dBf) AM18 VS/N (IHF-A) :FMMONO 78 dB AMSTEREO 68 dBHD 85 dB 85 dBTotal harmonic Distortion (at 1 kHz) :FMMONO 0.1 % AMSTEREO 0.1 %HD 0.02 % 0.02 % n Tuner section (for N, K) sFM(Note: V at 75 , 0 dBf = 1 x 1015 W)Receiving Range : FM 87.5 MHz 108.0 MHz AM522 kHz 1611 kHzUsable Sensitivity :FM1.2

42、V (12.8 dBf) AM18 V50 dB Quieting Sensitivity :FMMONO 2.0 V (17.3 dBf)STEREO 42 V (34.5 dBf)S/N (IHF-A) :FMMONO 72 dBSTEREO 67 dBTotal harmonic Distortion (at 1 kHz) :FMMONO 0.3 %STEREO 0.7 % n GeneralPower supply (for U) : AC 120 V, 60 HzPower supply (for N) : AC 230 V, 50 Hz Power supply (for K) :

43、 AC 220 V, 50 Hz sPower consumption :700 W0.2 W (Standby)4.0 W (CEC standby)Maximum external dimensions : 440 (W) x 187 (H) x 406 (D) mmWeight : 13.0 kg n Remote Control Unit (RC011SR)Batteries : R03/AAA Type (two batteries)625752.729.840.716.5170.518742326752.723.522.5360406100340440DIMENSION s7CAU

44、TION IN SERVICINGFirmware update s When you replace the DIGITAL UNIT ASSY (8U-310051), you need software updates. Refer to VERSION UPGRADE PROCEDURE OF FIRMWARE (27 - 37 page) .Please update the following procedure.1. First, Please update by DFW (34 - 37 page).2. Next, Please update the latest fi rm

45、ware by DPMS (27 - 33 page).Initializing AV SURROUND RECEIVERAV SURROUND RECEIVER initialization should be performed when the com, peripheral parts of com, and Digital P.W.B. are replaced.1. Turn off the power using ON/STANDBY button.2. Press ON/STANDBY button while simultaneously pressing SURROUND

46、MODE and AUTO buttons.3. Check that the entire display is fl ashing with an interval of about 1 second, and release your fi ngers from the 2 buttons and the microprocessor will be initialized.Service Jigs When you repair the printing board, you can use the following JIG (Extension cable kit). Please

47、 order to marantz Offi cial Service Distributor in your region if necessary.8U-110084S : EXTENSION UNIT KIT : 1 Set(Refer to JIG FOR SERVICING.)Note: If step 3 does not work, start over from step 1. All user settings will be lost and this factory setting will be recovered when this initialization mo

48、de. So make sure to memorize your setting for restoring after the initialization.ON/STANDBYSURROUND MODEAUTO8DISASSEMBLY Disassemble in order of the arrow of the fi gure of following fl ow. In the case of the re-assembling, assemble it in order of the reverse of the following fl ow. In the case of t

49、he re-assembling, observe attention of assembling it. If wire bundles are untied or moved to perform adjustment or parts replacement etc., be sure to rearrange them neatly as they were originally bundled or placed afterward.Otherwise, incorrect arrangement can be a cause of noise generation.FRONT PA

50、NEL ASSYRefer to DISASSEMBLY 1. FRONT PANEL ASSYand EXPLODED VIEWFRONT UNIT ASSY(Ref. No. of EXPLODED VIEW : P1)OPT UNIT(Ref. No. of EXPLODED VIEW : P2)H/P UNIT(Ref. No. of EXPLODED VIEW : P3)FRONT HDMI UNIT(Ref. No. of EXPLODED VIEW : P4)DOORDET UNIT(Ref. No. of EXPLODED VIEW : P5)TRANS MAINRefer t

展开阅读全文