NAD-M55-ddp-sm 维修电路原理图.pdf

上传人:cc518 文档编号:152256 上传时间:2024-07-20 格式:PDF 页数:78 大小:8.51MB
下载 相关 举报
NAD-M55-ddp-sm 维修电路原理图.pdf_第1页
第1页 / 共78页
NAD-M55-ddp-sm 维修电路原理图.pdf_第2页
第2页 / 共78页
NAD-M55-ddp-sm 维修电路原理图.pdf_第3页
第3页 / 共78页
亲,该文档总共78页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《NAD-M55-ddp-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《NAD-M55-ddp-sm 维修电路原理图.pdf(78页珍藏版)》请在收音机爱好者资料库上搜索。

1、SERVICE MANUALSERVICE MANUALM55MODEL : M55 AHSERVICE MANUAL NAD 2010NAD ELECTRONICS INTERNATIONALTORONTOM55DIGITAL DISC PLAYERM55DIGITAL DISC PLAYERDIGITAL DISCPLAYERRadioFans.CN 收音机爱 好者资料库CONTENTSSECTION 1 . . . .SUMMARYSECTION 2 . . . .CABINET CHASSIS NEW LOADERSECTION 3 . . . .ELECTRICALSECTION 4

2、 . . . .MECHANISM (ORIGINAL LOADER)SECTION 5 . . . .REPLACEMENT PARTS LISTRadioFans.CN 收音机爱 好者资料库SECTION 1SUMMARYCONTENTSPRODUCT SAFETY SERVICING GUIDELINES FOR VIDEO PRODUCTS. 1-3SERVICING PRECAUTIONS. 1-4 General Servicing Precautions Insulation Checking Prodedure Electrostatically Sensitive Devic

3、esSPECIFICATIONS. 1-51-21-3CAUTION : DO NOT ATTEMPT TO MODIFY THIS PRODUCT IN ANY WAY,NEVER PERFORM CUSTOMIZED INSTALLATIONS WITHOUT MANUFAC-TURERS APPROVAL. UNAUTHORIZED MODIFICATIONS WILL NOT ONLYVOID THE WARRANTY, BUT MAY LEAD TO YOUR BEING LIABLE FOR ANYRESULTING PROPERTY DAMAGE OR USER INJURY.S

4、ERVICE WORK SHOULD BE PERFORMED ONLY AFTER YOU ARETHOROUGHLY FAMILIAR WITH ALL OF THE FOLLOWING SAFETYCHECKS AND SERVICING GUIDELINES. TO DO OTHERWISE,INCREASES THE RISK OF POTENTIAL HAZARDS AND INJURY TO THEUSER.WHILE SERVICING, USE AN ISOLATION TRANSFORMER FOR PROTEC-TION FROM A.C. LINE SHOCK.SAFE

5、TY CHECKSAFTER THE ORIGINAL SERVICE PROBLEM HAS BEEN CORRCTED. ACHECK SHOULD BE MADE OF THE FOLLOWING.SUBJECT : FIRE & SHOCK HAZARD1. BE SURE THAT ALL COMPONENTS ARE POSITIONED IN SUCH A WAYAS TO AVOID POSSIBILITY OF ADJACENT COMPONENT SHORTS.THIS IS ESPECIALLY IMPORTANT ON THOSE MODULES WHICH ARETR

6、ANSPORTED TO AND FROM THE REPAIR SHOP.2. NEVER RELEASE A REPAIR UNLESS ALL PROTECTIVE DEVICESSUCH AS INSULATORS, BARRIERS, COVERS, SHIELDS, STRAIN RELIEFS, POWER SUPPLY CORDS, AND OTHER HARDWARE HAVEBEEN REINSTALLED PER ORIGINAL DESIGN. BE SURE THAT THESAFETY PURPOSE OF THE POLARIZED LINE PLUG HAS N

7、OT BEENDEFEATED.3. SOLDERING MUST BE INSPECTED TO DISCOVER POSSIBLE COLDSOLDER JOINTS, SOLDER SPLASHES OR SHARP SOLDER POINTS.BE CERTAIN TO REMOVE ALL LOOSE FOREIGN PARTICLES.4. CHECK FOR PHYSICAL EVIDENCE OF DAMAGE OR DETERIORATIONTO PARTS AND COMPONENTS. FOR FRAYED LEADS, DAMAGEDINSULATION (INCLUD

8、ING A.C. CORD). AND REPLACE IF NECESSARYFOLLOW ORIGINAL LAYOUT, LEAD LENGTH AND DRESS.5. NO LEAD OR COMPONENT SHOULD TOUCH A RECIVING TUBE ORA RESISTOR RATED AT 1 WATT OR MORE. LEAD TENSION AROUNDPROTRUNING METAL SURFACES MUST BE AVOIDED.6. ALL CRITICAL COMPONENTS SUCH AS FUSES, FLAMEPROOFRESISTORS,

9、 CAPACITORS, ETC. MUST BE REPLACED WITH EXACTFACTORY TYPES, DO NOT USE REPLACEMENT COMPONENTSOTHER THAN THOSE SPECIFIED OR MAKE UNRECOMMENDED CIR-CUIT MODIFICATIONS.7. AFTER RE-ASSEMBLY OF THE SET ALWAYS PERFORM AN A.C.LEAKAGE TEST ON ALL EXPOSED METALLIC PARTS OF THE CABI-NET, (THE CHANNEL SELECTOR

10、 KNOB, ANTENNA TERMINALS. HAN-DLE AND SCREWS) TO BE SURE THE SET IS SAFE TO OPERATEWITHOUT DANGER OF ELECTRICAL SHOCK. DO NOT USE A LINE ISOLATION TRANSFORMER DURING THIS TEST USE AN A.C. VOLT-METER, HAVING 5000 OHMS PER VOLT OR MORE SENSITIVITY, INTHE FOLLOWING MANNER; CONNECT A 1500 OHM 10 WATT RE

11、SIS-TOR, PARALLELED BY A .15 MFD. 150.V A.C TYPE CAPACITORBETWEEN A KNOWN GOOD EARTH GROUND (WATER PIPE, CON-DUIT, ETC.) AND THE EXPOSED METALLIC PARTS, ONE AT A TIME.MEASURE THE A.C. VOLTAGE ACROSS THE COMBINATION OF 1500 OHM RESISTOR AND .15 MFD CAPACITOR. REVERSE THE A.C. PLUGAND REPEAT A.C. VOLT

12、AGE MEASUREMENTS FOR EACH EXPOSED METALLIC PART. VOLTAGE MEASURED MUST NOT EXCEED 75VOLTS R.M.S. THIS CORRESPONDS TO 0.5 MILLIAMP A.C ANYVALUE EXCEEDING THIS LIMIT CONSTITUTES A POTENTIAL SHOCKHAZARD AND MUST BE CORRECTED IMMEDIATELY.SUBJECT: GRAPHIC SYMBOLSTHE LIGHTNING FLASH WITH APROWHEAD SYMBOL.

13、 WITHINAN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THESERVICE PERSONNEL TO THE PRESENCE OF UNINSULATED“DANGEROUS VOLTAGE” THAT MAY BE OF SUFFICIENT MAG-NITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK.THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIAN-GLE IS INTENDED TO ALERT THE SERVICE PERSONNEL TOT

14、HE PRESENCE OF IMPORTANT SAFETY INFORMATION INSERVICE LITERATURE.SUBJECT : X-RADIATION1. BE SURE PROCEDURES AND INSTRUCTIONS TO ALL SERVICE PER-SONNEL COVER THE SUBJECT OF X-RADIATION. THE ONLY POTEN-TIAL SOURCE OF X-RAYS IN CURRENT T.V. RECEIVERS IS THE PIC-TURE TUBE. HOWEVER, THIS TUBE DOES NOT EM

15、IT X-RAYS WHENTHE HIGH VOLTAGE IS AT THE FACTORY SPECIFIED LEVEL. THE PROPER VALUE IS GIVEN IN THE APPLICABLE SCHEMATIC. OPERA-TION AT HIGHER VOLTAGES MAY CAUSE A FAILURE OF THE PIC-TURE TUBE OR HIGH VOLTAGE SUPPLY AND, UNDER CERTAIN CIR-CUMSTANCES, MAY PRODUCE RADIATION IN EXCESS OF DESIR-ABLE LEVE

16、LS.2. ONLY FACTORY SPECIFIED C.R.T. ANODE CONNECTORS MUST BEUSED. DEGAUSSING SHIELDS ALSO SERVE AS X-RAY SHIELD INCOLOR SETS, ALWAYS RE-INSTALL THEM.3. IT IS ESSNTIAL THAT SERVICE PERSONNEL HAVE AVAILABLE ANACCURATE AND RELIABLE HIGH VOLTAGE METER. THE CALIBRATION OF THE METER SHOULD BE CHECKED PERI

17、ODICALLYAGAINST A REFERENCE STANDARD, SUCH AS THE ONE AVAILABLEAT YOUR DISTRIBUTOR.4. WHEN THE HIGH VOLTAGE CIRCUITRY IS OPERATING PROPERLYTHERE IS NO POSSIBILITY OF AN X-RADIATION PROBLEM. EVERYTIME A COLOR CHASSIS IS SERVICED. THE BRIGHTNESS SHOULDBE RUN UP AND DOWN WHILE MONITORING THE HIGH VOLTA

18、GEWITH A METER TO BE CERTAIN THAT THE HIGH VOLTAGE DOESNOT EXCEED THE SPECIFIED VALUE AND THAT IT IS REGULATINGCORRECTLY, WE SUGGEST THAT YOU AND YOUR SERVICE ORGA-NIZATION REVIEW TEST PROCEDURES SO THAT VOLTAGE REGU-LATION IS ALWAYS CHECKED AS A STANDARD SERVICING PROCE-DURE. AND THAT THE HIGH VOLT

19、AGE READING BE RECORDER ONEACH CUSTOMERS INVOICE.5. WHEN TROUBLESHOOTING AND MAKING TEST MEASUREMENTS INA PRODUCT WITH A PROBLEM OF EXCESSIVE HIGH VOLTAGE,AVOID BEING UNNECESSARILY CLOSE TO THE PICTURE TUBE ANDTHE HIGH VOLTAGE SUPPLY. DO NOT OPERATE THE PRODUCTLONGER THAN IS NECESSARY TO LOCATE THE

20、CAUSE OF EXCESSIVE VOLTAGE.6. REFER TO HV. B+ AND SHUTDOWN ADJUSTMENT PROCEDURES DESCRIBED IN THE APPROPRIATE SCHEMATIC AND DIAGRAMS(WHERE USED).SUBJECT: IMPLOSION1. ALL DIRECT VIEWED PICTURE TUBES ARE EQUIPPED WITH AN INTEGRAL IMPLOSION PROTECTION SYSTEM, BUT CARE SHOULD BETAKEN TO AVOID DAMAGE DUR

21、ING INSTALLATION, AVOIDSCRATCHING THE TUBE. IF SCRATCHED REPLACE IT.2. USE ONLY RECOMMENDED FACTORY REPLACEMENT TUBES.SUBJECT : TIPS ON PROPER INSTALLATION1. NEVER INSTALL ANY PRODUCT IN A CLOSED-IN RECESS, CUBBY-HOLE OR CLOSELY FITTING SHELF SPACE. OVER OR CLOSE TOHEAT DUCT, OR IN THE PATH OF HEATE

22、D AIR FLOW.2. AVOID CONDITIONS OF HIGH HUMIDITY SUCH AS: OUTDOOR PATIOINSTALLATIONS WHERE DEW IS A FACTOR, NEAR STEAM RADIA-TORS WHERE STEAM LEAKAGE IS A FACTOR, ETC.3. AVOID PALCEMENT WHERE DRAPERIES MAY OBSTRUCT REARVENTING. THE CUSTOMER SHOULD ALSO AVOID THE USE OF DEC-ORATIVE SCARVES OR OTHER CO

23、VERINGS WHICH MIGHTOBSTRUCT VENTILATION.4. WALL AND SHELF MOUNTED INSTALLATIONS USING A COMMER-CIAL MOUNTING KIT. MUST FOLLOW THE FACTORY APPROVED MOUNTING INSTRUCTIONS A PRODUCT MOUNTED TO A SHELF ORPLATFORM MUST RETAIN ITS ORIGINAL FEET (OR THE EQUIVALENTTHICKNESS IN SPACERS) TO PROVIDE ADEQUATE A

24、IR FLOW ACROSS THE BOTTOM, BOLTS OR SCREWS USED FOR FASTENERSMUST NOT TOUCH ANY PARTS OR WIRING. PERFORM LEAKAGETEST ON CUSTOMIZED INSTALLATIONS.5. CAUTION CUSTOMERS AGAINST THE MOUNTING OF A PRODUCT ONSLOPING SHELF OR A TILTED POSITION, UNLESS THE PRODUCT ISPROPERLY SECURED.6. A PRODUCT ON A ROLL-A

25、BOUT CART SHOULD BE STABLE ON ITSMOUNTING TO THE CART. CAUTION THE CUSTOMER ON THE HAZ-ARDS OF TRYING TO ROLL A CART WITH SMALL CASTERS ACROSSTHRESHOLDS OR DEEP PILE CARPETS.7. CAUTION CUSTOMERS AGAINST THE USE OF A CART OR STANDWHICH HAS NOT BEEN LISTED BY UNDERWRITERS LABORATORIES, INC. FOR USE WI

26、TH THEIR SPECIFIC MODEL OF TELEVISION RECEIVER OR GENERICALLY APPROVED FOR USE WITH T.V.S OFTHE SAME OR LARGER SCREEN SIZE.8. CAUTION CUSTOMERS AGAINST THE USE OF EXTENSION CORDS, EXPLAIN THAT A FOREST OF EXTENSIONS SPROUTING FROM A SIN-GLE OUTLET CAN LEAD TO DISASTROUS CONSEQUENCES TOHOME AND FAMIL

27、Y.PRODUCT SAFETY SERVICING GUIDELINES FOR VIDEO PRODUCTSA.C. VOLTMETERGOOD EARTH GROUNDSUCH AS THE WATERPIPE. CONDUIT. ETCPLACE THIS PROBEON EACH EXPOSEDMETAL PART1-4aSERVICING PRECAUTIONSCAUTION : Before servicing the DVD covered by this servicedata and its supplements and addends, read and follow

28、theSAFETY PRECAUTIONS. NOTE : if unforeseen circum-stances create conflict between the following servicing pre-cautions and any of the safety precautions in this publica-tions, always follow the safety precautions.Remembers Safety First:General Servicing Precautions1. Always unplug the DVD AC power

29、cord from the ACpower source before:(1)Removing or reinstalling any component, circuit board, module, or any other assembly.(2)Disconnection or reconnecting any internal electricalplug or other electrical connection.(3)Connecting a test substitute in parallel with an elec-trolytic capacitor.Caution

30、: A wrong part substitution or incorrect polarity installation of electrolytic capacitors may resultin an explosion hazard.2. Do not spray chemicals on or near this DVD or any ofits assemblies.3. Unless specified otherwise in this service data, cleanelectrical contacts by applying an appropriate con

31、tact cleaning solution to the contacts with a pipe cleaner,cotton-tipped swab, or comparable soft applicator.Unless specified otherwise in this service data, lubricationof contacts is not required.4. Do not defeat any plug/socket B+ voltage interlocks withwhitch instruments covered by this service m

32、anual mightbe equipped.5. Do not apply AC power to this DVD and/or any of itselectrical assemblies unless all solid-state device heatsinks are cerrectly installed.6. Always connect test instrument ground lead to theappropriate ground before connection the test instrumentpositive lead. Always remove

33、the test instrument ground lead last.Insulation Checking ProcedureDisconnect the attachment plug from the AC outlet and turnthe power on. Connect an insulation resistance meter(500V)to the blades of the attachment plug. The insulation resis-tance between each blade of the attachment plug and acces-s

34、ible conductive parts (Note 1) should be more than 1M-ohm.Note 1 : Accessible Conductive Parts including Metal pan-els, Input terminals, Earphone jacks, etc.Electrostatically Sensitive (ES) DevicesSome semiconductor (solid state) devices can be damagedeasily by static electricity. Such components co

35、mmonly arecalled Electrostatically Sensitive (ES) Devices. Examples oftypical ES devices are integrated circuits and some fieldeffect transistors and semiconductor chip components.The following techniques should be used to help reduce theincidence of component damage caused by static electricity.1.

36、Immediately before handling any semiconductor compo-nent or semiconductor-equipped assembly, drain off anyelectrostatic charge on your body by touching a knownearth ground. Alternatively, obtain and wear a commer-cially available discharging wrist strap device, which should be removed for potential

37、shock reasons prior to applying power to the unit under test.2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.3. Use only a grouned-tip soldering ir

38、on to solder or unsolderES devices.4. Use only an anti-static solder removal device. Somesolder removal devices not classified a “anti-static” cangenerate electrical charges sufficient to damage ES devices.5. Do not use freon-propelled chemicals. These cangenerate electrical charge sufficient to dam

39、age ESdevices.6. Do not remove a replacement ES device from its protective package until immediately before you are ready toinstall it. (Most replacement ES devices are packaged withleads electrically shorted together by conductive foam,aluminum foil, or comparable conductive material).7. Immediatel

40、y before removing the protective material fromthe leads of a replacement ES device, touch the protectivematerial to the chassis or circuit assembly into which thedevice will be installed.Caution : Be sure no power is applied to the chassis orcircuit, and observe all other safety precautions.8. Minim

41、ize bodily motions when handling unpackaged replacement ES devices. (Normally harmless motion such as the brushing together of your clothes fabric or the liftingof your foot from a carpeted floor can generate static elec-tricity sufficient to damage an ES device.)IMPORTANT M55 & M5 MECHANISM INSTALL

42、ATION NOTESINSTRUCTION FOR HANDLING 02-55598-00 FOR M55 & M5 AS WELL AS OPTICAL BLOCKElectrostatic breakdown of the laser diode in the optical system block may occur due to a poten-tial difference caused by electrostatic charge accumulated on clothing, human body, etc. A groundmust be provided as fo

43、llows to prevent any electrostatic charge during unpacking or repair work.1. Ground for Human BodyBe sure to wear a ground band (1M ohm) that is properly to remove any static electricity that maybe charged on the body.2. Ground for Work BenchBe sure to place a conductive sheet (1M ohm) or copper pla

44、te with proper grounding on the workbench or other surface on which the pick-up is to be placed.3. Because the static electricity charge on the clothing does not discharge through the bodygrounding band, do not let clothing to get in contact with the pick-up unit. INCORRECTCORRECTNOTE: Laser diodes

45、are so susceptible to damage fromstatic electricity that even if a static discharge does notruin the diode, it can shorten its life or cause it to workimproperly.1.Grounding band1M ohm1M ohm2.Conductive Sheetor Copper PlateGround ConductiveWrist Band for BodyGround LineLess than10 ohmConductive Gum

46、MatSolderingIron withGroundwireCaution:Laser diodes are extremely susceptible to damagefrom static electricity. Even if a static dis-chargedoes not ruin the diode, it can shorten its life or cause it to work improperly. When replac-ing the pick-up, use a conductive mat, a grounded soldering iron, an

47、d so on, to protect the laser diode from static damage.1-4b1-5SPECIFICATIONS GENERALPower requirements:AC 100-240 V , 50/60 HzPower consumption: 45W Dimensions (Approx.):435 x 100 x 300 mm (W x H x D) without foot Weight (Approx.): 8.6 kgOperating temperature:5 C to 35 C (41 F to 95 F)Operating humi

48、dity: 5 % to 90 % OUTPUTSVIDEO OUT:1 Vp-p 75 , sync negative, RCA jack x 1/ SCART (TO TV)AUDIO OUT:2.0 Vrms (1 KHz, 0 dB), 600 , RCA jack (L, R) x 1/ SCART (TO TV)DIGITAL OUT (COAXIAL):0.5 V (p-p), 75 , RCA jack x 1 SystemLaser: Semiconductor laser, wavelength 650 nmSignal system: PAL / NTSCFrequenc

49、y response:DVD (PCM 96 kHz): 8 Hz to 44 kHz DVD (PCM 48 kHz): 8 Hz to 22 kHzCD: 8 Hz to 20 kHzSignal-to-noise ratio:More than 100 dB (ANALOG OUT connectors only)Harmonic distortion: Less than 0.008%Dynamic range:More than 85 dB (DVD/CD) AccessoriesVideo cable (1), Audio cable (1), Remote control (1)

50、, Batteries (2)SECTION 2 CABINET & MAIN CHASSISCONTENTSEXPLODED VIEWS.2-21. Cabinet and Main Frame Section.2-2,32. Exploded view parts list .2-4 3. New Loader, Rail Assembly & Loader Driv e Current Change .2-5-7 4. New FFC Bend Angle wit hout Clamp .2-8 5. Packing accessory sect ion.2-92-12-22-31.Ca