JVC-FSSD1000-cs-sm 维修电路原理图.pdf

上传人:cc518 文档编号:160256 上传时间:2022-07-13 格式:PDF 页数:61 大小:4.30MB
下载 相关 举报
JVC-FSSD1000-cs-sm 维修电路原理图.pdf_第1页
第1页 / 共61页
JVC-FSSD1000-cs-sm 维修电路原理图.pdf_第2页
第2页 / 共61页
JVC-FSSD1000-cs-sm 维修电路原理图.pdf_第3页
第3页 / 共61页
亲,该文档总共61页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《JVC-FSSD1000-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-FSSD1000-cs-sm 维修电路原理图.pdf(61页珍藏版)》请在收音机爱好者资料库上搜索。

1、SERVICE MANUALCOMPACT COMPONENT SYSTEMNo.21011Jul. 2001COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD.FS-SD1000FS-SD1000REMOTE CONTROL RM-SFSSD1000J STANDBY/ONDIMMERSLEEPDISPLAYFM MODECDPROGRAMDOORSLIDEAUTOPRESETREPEATRANDOMBASSTREBLECANCELUPSETDOWNMD/AUXFM /AMVOLUMECDFADE MUTINGSP-PW1000SP-FSSD1000CA-

2、FSSD1000SP-FSSD1000ContentsSafety PrecautionsPreventing static electricityImportant for laser productsDisassembly methodMaintenance of laser pickupReplacement of laser pickupFlow of functional operation unit TOC readMethod of connecting treatment device wireDescription of major ICs 1-21-31-41-51-161

3、-161-171-181-1931This model not have adjustment. Area suffix UF - China UP - Korea US - Singapore UT - Taiwan UW - Brazil,Mexico,PeruRadioFans.CN 收音机爱 好者资料库FS-SD10001-21. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continu

4、ed protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterations of the design or circuitry of the prod

5、uct should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mech

6、anical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which

7、 have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same s

8、afety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts,

9、 moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.5. Leakage currnet check (Electrical shock h

10、azard testing)After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not

11、use a line isolation transformer during this check.Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good ear

12、th ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).Alternate check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor

13、 between an exposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to eachexposed metal part, particularly any exposed metal part having a return path to the chassis, and meausre the AC voltage across the resist

14、or. Now, reverse the plug in the AC outlet and repeat each measurement. voltage measured Any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of th

15、e repairer to ensure that these safety standards are maintained.3. Repairs must be made in accordance with the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Good ea

16、rth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.In reg

17、ard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. When replacing them, be sure to use the parts of t

18、he same type and rating as specified by the manufacturer. (Except the JC version)RadioFans.CN 收音机爱 好者资料库FS-SD10001-3ShortingFlexible cableSub board(Reverse side)Preventing static electricity1.Grounding to prevent damage by static electricityElectrostatic discharge (ESD), which occurs when static ele

19、ctricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.2.About the earth processing for the destruction prevention by static electricity Static electricity in the work area can dest

20、roy the optical pickup (laser diode) in devices such as CD players. Be careful to use proper grounding in the area where repairs are being performed. 2-1 Ground the workbench Ground the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the t

21、raverse unit (optical pickup) on it.2-2 Ground yourself Use an anti-static wrist strap to release any static electricity built up in your body. 3. Handling the optical pickup1. In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement opt

22、ical pickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.)2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily destroy the laser diode. 4.Handling the traverse

23、unit (optical pickup)1. Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit. 2. Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refer to the replacement procedure in the te

24、xt. Remove the anti-static pin when replacing the traverse unit. Be careful not to take too long a time when attaching it to the connector. 3. Handle the flexible cable carefully as it may break when subjected to strong force. 4. It is not possible to adjust the semi-fixed resistor that adjusts the

25、laser power. Do not turn itConductive material (conductive sheet) or iron plate(caption)Anti-static wrist strapAttention when traverse unit is decomposed1.Solder is put up before the card wire is removed from connector on the CD substrate as shown in Figure. (When the wire is removed without putting

26、 up solder, the CD pick-up assembly might destroy.)2.Please remove solder after connecting the card wire with when you install picking up in the substrate.*Please refer to Disassembly method in the text for pick-up and how to detach the substrate. FS-SD10001-4Important for laser products1.CLASS 1 LA

27、SER PRODUCT2.DANGER : Invisible laser radiation when open and inter lock failed or defeated. Avoid direct exposure to beam.3.CAUTION : There are no serviceable parts inside theLaser Unit. Do not disassemble the Laser Unit. Replace the complete Laser Unit if it malfunctions.4.CAUTION : The compact di

28、sc player uses invisible laser radiation and is equipped with safety switches which prevent emission of radiation when the drawer is open and the safety interlocks have failed or are defeated. It is dangerous to defeat the safety switches.5.CAUTION : If safety switches malfunction, the laser is able

29、 to function.6.CAUTION : Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.VARNING : Osynlig laserstrlning r denna del r ppnad och sprren r urkopplad. Betrakta ej strlen.VARO : Avattaessa ja suojalukitus ohitettaess

30、a olet alttiina nkymttmlle lasersteilylle.l katso steeseen.ADVARSEL : Usynlig laserstrling ved bning , nr sikkerhedsafbrydere er ude af funktion. Undg udsttelse for strling.ADVARSEL : Usynlig laserstrling ved pning,nr sikkerhetsbryteren er avslott. unng utsettelse for strling.REPRODUCTION AND POSITI

31、ON OF LABELSWARNING LABELDANGER : Invisible laser radiation when open and interlock or defeated.AVOID DIRECT EXPOSURE TO BEAM (e)VARNING : Osynlig laserstrlning r denna del r ppnad och sprren r urkopplad. Betrakta ej strlen. (s)VARO : Avattaessa ja suojalukitus ohitettaessa olet alttiina nkymttmlle

32、lasersteilylle.l katso steeseen. (d)ADVARSEL :Usynlig laserstrling ved bning , nr sikkerhedsafbrydere er ude af funktion. Undg udsttelse for strling. (f)CLASS 1LASER PRODUCT!CAUTIONPlease use enough caution not to see the beam directly or touch it in case of an adjustment or operationcheck.FS-SD1000

33、1-5Piror to performing the following procedure, remove the CD door.Remove the ten screws B and the five screws C attaching the rear cover on the back of the body.1.Removing the rear cover (See Fig.2)Remove the four screws A attaching the CD door on the upper side of the body.1.Removing the CD door (

34、See Fig.1)Prior to performing the following procedure, remove the CD door, the rear cover.Remove the four screws D attaching the side covers on the bottom of the body.Move the left cover backward and remove outward. Also remove the right cover in the same way.1.2.Removing the right and left covers (

35、See Fig.3)Disassembly methodFig.1Fig.2Fig.3BBBBBBCCCRear coverDDRight coverLeft coverBottomCD doorAAFS-SD10001-6Prior to performing the following procedure, remove the CD door, the rear cover and the side covers.Remove the three screws E on the bottom of the body.Release two joints a and two joints

36、b on both sides of the body using a screwdriver and remove the front panel assembly toward the front.1.2.Removing the front panel assembly (See Fig.4 to 6)Prior to performing the following procedure, remove the CD door, the rear cover, the side covers and the front panel assembly.Disconnect the card

37、 wire from connector CN104 and CN105 of the main board in the front part of the body. Disconnect the card wire from CN101 of the main board on the right side, and the wire from CN705 and CN708 of the CD mechanism base assembly respectively.Remove the four screws F attaching the CD mechanism base ass

38、embly on the upper side of the body. Remove the screw I attaching the earth terminal on the right side.1.2.Removing the CD mechanism base assembly (See Fig.7 to 14)Fig.4Fig.6Fig.5EFront panel assembly(Left side)(Right side)Front panel assemblyJoints aJoints bBottomFig.7Fig.8FFCD mechanism base assem

39、blyCD mechanism base assemblyMain bardCN105CN104Front panel assemblyFS-SD10001-7Remove the screw G attaching the power amplifier board on the back of the body. Disconnect the wire from connector CN301 and pull the power amplifier board fully outward.Raise the right and left door arms by turning the

40、gear a in the rear of the power amplifier board.After the CD mechanism base assembly is detached from the door arms, pull the CD mechanism base assembly toward the front and disconnect the wire from connector CN804 on the left side of the door arm board.Pull out the CD mechanism base assembly toward

41、 the front.3.4.5.6.Fig.9Fig.10Fig.11FICD mechanism base assemblyMain boardCN101CN708FCD mechanism base assemblyCN804CD mechanism base assemblyCN301GPower amplifier boardFig.13Gear aFig.12Fig.14CD mechanism base assemblyPower amplifier boardDoor armDoor armIGear aCD mechanism base assemblyDoor arm bo

42、ard (L)CN804CN705FS-SD10001-8Prior to performing the following procedure, remove the rear cover, the side covers, the front panel assembly and the CD mechanism base assembly.In case that the upper parts of the door arms attached to the CD door are not level, let down them to the level position by tu

43、rning the gear a in the direction of the arrow.1.Removing the door arm assembly / the door arm board (R) and (L)(See Fig.15 to 20)When the door arms incline, the door arm assembly and the door arm board (R) and (L) may not be removed.ATTENTION: Remove the four screws H on the upper side and the one

44、screw I on the left side of the body.Remove the four screws J attaching the door arm board (L) and (R) on both sides of the door arm assembly.2.3.Fig.15Fig.16Fig.18Fig.20Fig.17Fig.19Door armDoor arm board (L)Door armDoor arm board (R)Door arms (Attached to the CD door)HHDoor arm assemblyDoor arm ass

45、emblyJJIDoor arm board (L)Door arm assemblyJJDoor arm board (R)Fan motorFS-SD10001-9Prior to performing the following procedure, remove the CD mechanism base assembly.Disconnect the wires from connector CN102 and CN193 on the main board and release them from the cord stopper respectively.Remove the

46、two screws K and the two screws L attaching the heat sink and the power amplifier board.1.2.Removing the power amplifier board(See Fig.21 and 22)Prior to performing the following procedure, remove the CD mechanism base assembly.Disconnect the wires from connector CN191 and CN192 on the main board an

47、d release them from the cord stopper respectively.Remove the four screws M attaching the transformer assembly.1.2.Removing the transformer assembly (See Fig.21)Prior to performing the following procedure, remove the CD mechanism base assembly and the door arm assembly.Disconnect the wires from conne

48、ctor CN106 on the main board and release it from the cord stopper.Remove the three screws N attaching the gear motor assembly. Remove the gear motor assembly with the gear motor stopper.Remove the belt from the gear motor assembly.Remove the two screws O from the gear motor assembly.1.2.3.4.Removing

49、 the gear motor assembly (See Fig.23 and 24)Fig.21Fig.22Fig.23Fig.24Power amplifier boardDoor arm assemblyCN191CN193Cord stopperCord stopperMain boardCN106CN181CN192CN102Cord stopperMMTransformer assemblyPower amplifier boardHeat sinkKLGear motor stopperGear motor assemblyCord stopperCN106NNMotorBel

50、tOCord stopperFS-SD10001-10Prior to performing the following procedure, remove the CD mechanism base assembly.Disconnect the wires from connector CN181 on the main board.Remove the two screws P on the left side of the body. Move the fan motor assembly upward to remove it from the base chassis.Remove

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 卡座/开盘/组合/收录机 > JVC

copyright@ 2008-2023 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号