《JVC-RCST1-cs-sch 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RCST1-cs-sch 维修电路原理图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCD PORTABLE SYSTEMNo.MB0622003/11COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD.RC-ST1SLRC-ST1RDRC-ST1BKContentsArea SuffixB - U.K.E -Contnental EuropeEN - Northern EuropeEV - Eastern EuropeSpecification -1-2Safety Precautions -1-3Important of laser products - 1-5preventing static electri
2、city - 1-6Block Diagram - 1-8Schematic Diagrams - 1-10Assembly - 1-14RadioFans.CN 收音机爱 好者资料库1-2Compact disc player sectionTypeCompact disc playerSignal detectionNon-contact optical pick-up (semiconductor laser)Number of channels2 channelsRadio sectionFrequency rangesFM 88 MHz - 108 MHzAM 530 kHz - 1
3、,600 kHzAntennasTelescopic antenna for FMFerrite core antenna for AMCassette deck sectionTrack4-track 2-channel stereoMotorElectronic governor DC motor for capstanHeadsHard permalloy head for recording/playback, magnetic head for erasureFast wind timeApprox. 120 sec. (C-60 cassette)GeneralSpeakers10
4、 cm 2 (8 )Power output2 W per channel, min. RMS, driven into 8 at 1 kHz, with no more than10% total harmonic distortion (IEC 268-3)Output terminalPHONES 1 ( 3.5 mm, stereo)Power supplyAC 230 V, 50 HzDC 12 V (“R20/D (13F)” cells 8)Power consumption19 W (power-on mode)2.5 W (standby mode)Dimensions440
5、 mm (W) 168 mm (H) 241 mm (D)MassApprox. 3 kg (without batteries)Accessories provided AC power cord 1Remote control unit 1Batteries for remote control unit, R03 (UM-4)/AAA (24F) 2SpecificationRadioFans.CN 收音机爱 好者资料库1-31. This design of this product contains special hardware and many circuits and com
6、ponents specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2.
7、Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property dama
8、ge resulting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for hig
9、her voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a sub
10、stitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be
11、separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assem
12、bling.5. Leakage currnet check (Electrical shock hazard testing)After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to
13、operate without danger of electrical shock.Do not use a line isolation transformer during this check.Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having
14、 a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).Alternate check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W
15、 resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the ch
16、assis, and meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1. This equipment has been designed and manufactured to meet international safet
17、y standards.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs must be made in accordance with the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector i
18、s provided, check setting for local voltage.Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in
19、the case of preforming repair of this system.In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety.
20、 (This regulation does not correspond to J and C version.)1-41. Service should be performed by qualified personnel only.2. This equipment has been designed and manufactured to meet international safety standards.3. It is the legal responsibility of the repairer to ensure that these safety standards
21、are maintained.4. Repairs must be made in accordance with the relevant safety standards.5. It is essential that safety critical components are replaced by approved parts.6. If mains voltage selector is provided, check setting for local voltage.1. This design of this product contains special hardware
22、 and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. 2. Any unauthorised design alterat
23、ions or additions will void the manufacturers guarantee ; furthermore the manufacturer cannot accept responsibility for personal injury or property damage resulting therefrom.3. Essential safety critical components are identified by ( ) on the Parts List and by shading on the schematics, and must ne
24、ver be replaced by parts other than those listed in the manual. Please note however that many electrical and mechanical parts in the product have special safety related characteristics. These characteristics are often not evident from visual inspection. Parts other than specified by the manufacturer
25、 may not have the same safety characteristics as the recommended replacement parts shown in the Parts List of the Service Manual and may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from liv
26、e parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.!Burrs forme
27、d during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.(U.K only)1-5Important for laser products1.CLASS 1 LASER PRODUCT2.DANGER : Invisible laser radiation when open and inter lock failed or defeated. Avo
28、id direct exposure to beam.3.CAUTION : There are no serviceable parts inside theLaser Unit. Do not disassemble the Laser Unit. Replace the complete Laser Unit if it malfunctions.4.CAUTION : The compact disc player uses invisible laser radiation and is equipped with safety switches which prevent emis
29、sion of radiation when the drawer is open and the safety interlocks have failed or are defeated. It is dangerous to defeat the safety switches.5.CAUTION : If safety switches malfunction, the laser is able to function.6.CAUTION : Use of controls, adjustments or performance of procedures other than th
30、ose specified herein may result in hazardous radiation exposure.VARNING : Osynlig laserstrlning r denna del r ppnad och sprren r urkopplad. Betrakta ej strlen.VARO : Avattaessa ja suojalukitus ohitettaessa olet alttiina nkymttmlle lasersteilylle.l katso steeseen.ADVARSEL : Usynlig laserstrling ved b
31、ning , nr sikkerhedsafbrydere er ude af funktion. Undg udsttelse for strling.ADVARSEL : Usynlig laserstrling ved pning,nr sikkerhetsbryteren er avslott. unng utsettelse for strling.Position and position of labelsWARNING LABEL! CAUTIONPlease use enough caution not to see the beam directly or touch it
32、 in case of an adjustment or operationcheck.DANGER : Invisibie laser radiation when open and interlock or defeated.AVOID DIRECT EXPOSURE TO BEAM (e)VARNING : Osynlig laserstrlning r denna del r ppnad och sprren r urkopplad. Betrakta ej strlen. (s)VARO : Avattaessa ja suojalukitus ohitettaessa olet a
33、lttiina nkymttmlle lasersteilylle.l katso steeseen. (d)ADVARSEL :Usynlig laserstrling ved bning , nr sikkerhedsafbrydere er ude af funktion. Undg udsttelse for strling. (f)CLASS 1LASER PRODUCTCLASS 1LASER PRODUCTCLASS1 LABELPLACED OUTSIDETHE UNITWAQRNING LABELPLACED INSIDETHE UNIT1-6Preventing stati
34、c electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs. Grounding to prevent damage by static electricityStat
35、ic electricity in the work area can destroy the optical pickup (laser diode) in devices such as mechanism unit. Be careful to use proper grounding in the area where repairs are being performed. 1. Ground the workbench Ground the workbench by laying conductive material (such as a conductive sheet) or
36、 an iron plate over it before placing the traverse unit (optical pickup) on it.2. Ground yourself Use an anti-static wrist strap to release any static electricity built up in your body. 3. Handling the optical pickup1. In order to maintain quality during transport and before installation, both sides
37、 of the laser diode on the replacement optical pickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.)2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily destroy
38、 the laser diode. Handling the traverse unit (optical pickup)1. Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit. 2. Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refe
39、r to the replacement procedure in the text. Remove the anti-static pin when replacing the traverse unit. Be careful not to take too long a time when attaching it to the connector. 3. Handle the flexible cable carefully as it may break when subjected to strong force. 4. It is not possible to adjust t
40、he semi-fixed resistor that adjusts the laser power. Do not turn it(caption)Anti-static wrist strapConductive material (conductive sheet) or iron plate1-71-8Block Diagram1-91-10Main CircuitSchematic Diagrams1-111-12CD Servo Circuit1-131-14Assembly-1S11819S1S1101175463211-15S11112131415S4S32120S11819S21617S4S1S1981-16Assembly-21767S1054321879S9111213S810141819S620S722211615S3S2S123S4S51-171-18Assembly-3S7S7S6S8S811S598S7FRONT CABINETCD TRAY1-198S41076S3S3S3S3S254132S1(No.MB062)2003/11JVC Euorpe LimitedJVC HouseJVC Budiness Park 12 Priestley Way, London NW2 7BA United Kingdom