1、AD0303010C8Cassette DeckRS-DV290EGColour(S).Silver TypeSPECIFICATIONS RadioFans.CN 收音机爱 好者资料库1. NoteRefer to the service manual for Model No. SA-EH590EG, SA-EH590EP (Order No. AD0302008C8) for information on Accessories and Packaging.2. Location of Controls3. Operation Checks and Component Replaceme

2、nt / Procedures- This section describes procedures for checking the operation of the major printed circuit boards and replacing the main components.- For reassembly after operation checks or replacement, reverse the respective procedures. Special reassembly procedures are described only when require

3、d.3.1. Checking for the main P.C.B.- Check the main P.C.B. as shown above.3.2. Checking for the operation P.C.B.- Follow the (Step 1) - (Step 3) of item 3.1.2RadioFans.CN 收音机爱 好者资料库3- Check the operation P.C.B. as shown below.3.3. Replacement for the motor assy, capstan belt and winding belt- Follow

4、 the (Step 1) - (Step 3) of item 3.1.4- Follow the (Step 1) - (Step 7) of item 3.2.5673.4. Replacement for the components parts on the mechanism P.C.B.- Follow the (Step 1) - (Step 3) of item 3.1.- Follow the (Step 1) - (Step 7) of item 3.2.- Follow the (Step 1) - (Step 4) of item 3.3.83.5. Replacem

5、ent for the pinch roller assy and head block- Follow the (Step 1) - (Step 3) of item 3.1.- Follow the (Step 1) - (Step 7) of item 3.2.- Follow the (Step 1) - (Step 5) of item 3.3.3.6. Replacement for the cassette lid assy- Follow the (Step 1) - (Step 3) of item 3.1.93.7. Replacement for the cassette

6、 holder- Follow the (Step 1) - (Step 3) of item 3.1.- Follow the (Step 1) - (Step 11) of item 3.2.104. To Supply Power SourceThis unit is designed to operate on power supplied from system connected. / When a component requires service, use the system connections to supply power source. / For system

7、connections, refer to Fig.4-1. Fig. 4-1.5. Service Mode Function of Cassette MechanismThis unit is equipped with a service mode function of cassette mechanism, so that if the unit operates incorrectly, the fault displayed using an error code on the FL display of the Tuner/Amplifier (SA-EH590). The s

8、ystem control IC and FLdisplay are part of the Tuner/Amplifier so make sure the system has been connected properly before using this function. Use this function during maintenance to check faults of items below.5.1. Cassette tape to be preparedMetal tape:Recorded music tape with only one erasure pre

9、vention tab intact. / (use middle portion of tape)Normal tape: / CrO2 tape:Recorded music tape with both erasure prevention tabs intact. / (use middle portion of tape)115.2. Selecting service mode1. Turn on the power to the unit.2. Make sure that no tape is inserted in the cassette deck. (Service mo

10、de cannot be selected with a tape inserted in the cassette deck.)3. Press the DOLBY NR button for about 2 seconds, and keep pressing it, also press the STOP button for about 2 seconds. Refer to Fig. 5-1.Fig. 5-1.5.3. Deck 1 mechanism check1. Press the Deck 1/deck 2 select button to change the flashi

11、ng Deck 2 indicator to Deck 1. Refer to Fig. 5-2. / (No change required if Deck 1 indicator already flashing.) 2. Press the Deck 1 cassette holder open button to open the Deck 1 cassette holder. Refer to Fig. 5-2.3. Insert a CrO2 tape into the Deck 1 and close the cassette holder.4. Press the Fast f

12、orward button. Refer to Fig. 5-2. / (Tape fast forwards for about 2 seconds then stops.)5. Press the PLAY button. Refer to Fig. 5-2. / (After TPS operation and check, the tape stops.)6. Open the Deck 1 cassette holder and replace the tape with a normal tape.7. Close the Deck 1 cassette holder.8. Pre

13、ss the Record pause button. Refer to Fig. 5-2. / (No record operation.)9. Press the STOP button. Refer to Fig. 5-2. A mechanism error code is displayed. Refer to Table 5-1. Each time the STOP button is 12pressed, the fault items are displayed in sequence. Fig. 5-2.Table 5-1.FL displaySymptomCauseH01

14、Cassette deck does not operate correctly.Faulty cassette deck mechanism mode switch (Deck 1: S951, Deck 2: S971), plunger and capstan motor. / (Check and replace)H02Unit does not record or the unit goes into recording mode even when the erasure prevention tabs have been removed from the cassette.Fau

15、lty erasure prevention tabs detect switch (S974, S975) or short-circuit. (Check and replace)H03Tape does not play even when the tape deck play button is pressed. The motor operates when the tape deck play button is pressed even if cassette is loaded in the deck.Faulty tape detect switch (Deck 1: S95

16、2 S972) or short-circuit. (Check and replace)H06Cassette deck does not detect CrO2 tape.Faulty CrO2 tape detect switch (Deck 1Deck 2: S973). / (Check and replace)H07Cassette deck does not detect Metal tape.Faulty Metal tape detect switch (S976). and replace)F01When the tape play button is pressed, t

17、ape advances only slightly and then stops.Reel pulse error (Faulty Hall IC). (Check replace)F02TPS (tape program search) does not work.Faulty TPS signal detection or faulty plunger control. / (Check and replace mechanism control IC)5.4. Deck 2 mechanism check1. Press the Deck 1/deck 2 select button

18、to change the flashing Deck 1 indicator to Deck 2. Refer to Fig. 5-3.2. Press the Deck 2 cassette holder open button to open the Deck 2 13cassette holder. Refer to Fig. 5-3.3. Insert a metal tape into the Deck 2 with an intact erasure prevention tab on the right side.4. Close the Deck 2 cassette hol

19、der.5. Press the Fast forward button. Refer to Fig. 5-3. / (Tape fast forwards for about 2 seconds then stops.) 6. Open the Deck 2 cassette holder and turn over the metal tape. (intact erasure prevention tab on the left side.)7. Close the Deck 2 cassette holder.8. Press the Rewind button. Refer to F

20、ig. 5-3. / (Tape rewinds for about 2 seconds then stops.)9. Open the Deck 2 cassette holder and replace the metal tape with a CrO2 tape.10. Close the Deck 2 cassette holder.11. Press the PLAY button. Refer to Fig. 5-3. / (After TPS operation and check, the tape stops.)12. Open the Deck 2 cassette ho

21、lder and replace the CrO2 tape with a normal tape.13. Close the Deck 2 cassette holder.14. Press the Record pause button. Refer to Fig. 5-3. / (No record operation.)15. Press the STOP button. Refer to Fig. 5-3. A mechanism error code is displayed. Refer to Table 5-1. Each time the STOP button is pre

22、ssed, the fault items are displayed in sequence.Fig. 5-3.145.5. Exiting service mode1. Press the STOP button for more than 5 seconds. (Diagnostic contents stored in memory for both Deck 1 and 2 are erased.)2. Remove the cassette tape from the cassette holder.3. Turn off the unit.6. Schematic Diagram

23、 Notes- This schematic diagram may be modified at any time with the development of new technology.Notes:S900:Stop switch ()S901:Deck 2 cassette holder open switch (OPEN)S903:Tape edit switch (TAPE EDIT)S904:Record pause switch / (REC PAUSE)S905:Dolby noise reduction switch / (DOLBY NR)S906:15Fast fo

24、rward, TPS switch ()S907:Forward side playback switch ()S909:Reverse side playback switch ()S910:Rewind, TPS switch ()S911:Reverse mode switch / (REV MODE)S912:Deck 1/deck 2 select switch / (DECK 1/2)S913:Counter display switch / (COUNTER DISPLAY)S914:Counter reset switch / (COUNTER RESET)S915:Deck

25、1 cassette holder open switch (OPEN)S951:Deck 1 mode detect switchS952:Deck 1 half detect switchS953:Deck 1 CrO2 tape detect switchS971:Deck 2 mode detect switchS972:Deck 2 half detect switchS973:Deck 2 CrO2 tape detect switch16S974:Deck 2 reverse side record prevention tab detect switchS975:Deck 2

26、forward side record prevention tab detect switchS976:Deck 2 METAL tape detect switchVR101:Deck 1 playback gain adjustment VR / (R ch)VR102:Deck 2 playback gain adjustment VR / (L ch)VR103:Deck 2 playback gain adjustment VR / (R ch)VR104:Deck 1 playback gain adjustment VR / (L ch)VR801:Deck 1 tape sp

27、eed adjustment VR (normal)VR803:Deck 2 tape speed adjustment VR (normal)- Indicated voltage values are the standard values for the unit measured by the DC electronic circuit tester (high-impedance) with the chassis taken as standard. Therefore, there may exist some errors in the voltage values, depe

28、nding on theinternal impedance of the DC circuit tester.No mark: Playback( ): Recording- Important safety notice:Components identified by mark have special characteristics important for safety.Furthermore, special parts which have purposes of fire-retardant (resistors), high-quality sound (capacitor

29、s), low-noise (resistors), etc. are used.17When replacing any of components, be sure to use only manufacturers specified parts shown in the parts list.- The supply part number is described alone in the replacement parts list.- Caution!IC and LSI are sensitive to static electricity.Secondary trouble

30、can be prevented by taking care during repair.Cover the parts boxes made of plastics with aluminum foil.Ground the soldering iron.Put a conductive mat on the work table.Do not touch the legs of IC or LSI with the fingers directly.- Voltage and signal line: Positive voltage line: Playback signal line

31、: Recording signal line7. Schematic Diagram8. Printed Circuit Board Diagram9. Type Illustration of ICs, Transistors and Diodes10. Wiring Connection Diagram11. Block Diagram12. Terminal Function of ICs12.1. IC701 (M38503M2406F): / System Control18Pin No.Terminal NameI/OFunction1VCCIPower supply termi

32、nal2VREFIReference voltage input3AVSS-GND terminal4LMTOMuting control signal output5PL1ODeck 1 solenoid control signal output6M1ODeck 1 motor drive control signal output7HALTIPower failure detect signal input8REQISerial communication request signal input9CSISerial communication complete signal input

33、10CLKOSerial communication clock signal output11DATA OUTOSerial communication data signal output12 DATA INISerial communication data signal input13 METAL 2IDeck 2 tape detect switch signal (METAL) input14CRO2 2IDeck 2 tape detect switch signal (CrO2) input15VSS-GND terminal16 FWD LEDOLED drive contr

34、ol signal (FWD) output17 REV LEDOLED drive control signal (REV) output18RESETIReset signal input19XINIOscillator connected terminal (F=8 MHz)20XOUTO21VSS-GND terminal22CRO2 1IDeck 1 tape detect switch signal (CrO2) input23MODEIDeck 1 mechanism switch signal (MODE) input24HALF1IDeck 1 mechanism switc

35、h signal (Half) input25TPSITPS signal input26A DATAOSerial data signal output for IC 10127A CLKOSerial clock signal output for IC 10128 A LATCHOSerial latch signal output for IC 10119101Pin No.Terminal NameI/OFunction29PL2ODeck 2 solenoid control signal output30M2ODeck 2 motor drive control signal o

36、utput31 ENC/DECODolby NR record/playback mode select signal output32 DOLBY ON/OFFODolby NR ON/OFF control signal output33E CS-EEPROM chip select signal output (Not used, open)34 | 36 NC - Not used, open 37 LED CNTOLED color control signal output38PHOTO2TIDeck 2 reel pulse detect signal input39AD SWI

37、Deck 2 mechanism switch signal input (Half, Mode, F REC INH., R REC INH.)40PHOTO1TIDeck 1 reel pulse detect signal input41KEY2IOperation key signal input42KEY1IOperation key signal input13. Measurements and AdjustmentsNote:This unit RS-DV290 is designed to operate on power supplied from system conne

38、cted.13.1. Measurement condition- Dolby NR switch is OFF- Make sure heads are clean- Make sure capstan and pressure roller are clean- Temperature is 20 5 C13.2. Measurement instrument and special tool- Electronic Voltmeter- Frequency Counter20- AF Oscillator- Test tape- Head azimuth adjustment (8 kH

39、z, -20 dB): QZZCFM- Tape speed adjustment (3 kHz, -10 dB): QZZCWAT- Playback gain adjustment (315 Hz, 0 dB): QZZCFM- Recording/playback frequency response check:QZZCFM / (315 Hz, -20 dB, 12.5 kHz63 Hz, -20 dB)QZZCRA4 (Normal blank tape)QZZCRX2 (CrO2 blank tape)QZZCRZ6 (Metal blank tape)13.3. Head az

40、imuth adjustment (Deck 1/2)1. Connect the measuring instrument as shown in Fig. 13-1.2. Replace azimuth screws for both forward and reverse directions after removing the screw-locking bond left on the head base. (Supply part No. of azimuth screw: RHD17015 )3. Playback the azimuth adjustment portion

41、(8 kHz, -20 dB) of test tape (QZZCFM). Adjust the azimuth screw until the outputs of the L/R ch are maximized. Refer to Fig. 13-2. Make sure that thedifference in the peak level between the left and right channels does not exceed 0.5 dB.4. Perform the same adjustment in reverse playback mode.Check o

42、f the level difference forward and reverse directions.5. Playback the playback gain adjustment portion (315 Hz, 0 dB) of test tape (QZZCFM). Check if level difference between forward and reverse direction is within 1.5 dB.6. After the adjustment, apply screw lock to the azimuth screw.Fig. 13-1.Fig.

43、13-2.2113.4. Tape speed adjustment / (Deck 1/2)Note:When connecting the unit to other system components for test, short the section between the test point TP604 and TP609 and turn on the entire system. (The unit is set to the TEST mode, and either Deck 1 or Deck 2 indicatorwill blink.)Normal speed (

44、Standard value: 3000 45 Hz)1. Connect the measuring instrument as shown in Fig. 13-3.2. Playback the middle portion of test tape. (QZZCWAT)3. Adjust VR801 (Deck 1) and VR803 (Deck 2) for output value shown below. (For adjustment point, refer to Fig. 13-11. )Adjustment target: 3000 15 Hz (Normal spee

45、d)Standard value: 3000 45 Hz (Normal speed)Fig. 13-3.Note:When the unit is finished for adjusting, disconnect the short section between TP604 and TP609 .13.5. Playback gain adjustment (Deck 1/2)1. Connect the measuring instrument as shown in Fig. 13-4.2. Find the start of the 315 Hz, 0 dB section of

46、 test tape (QZZCFM), insert the tape into Deck 1 and 2, and play it back (FWD).3. Adjust Deck 2: VR102 (L ch) VR103 (R ch) and Deck 1: VR104 (L ch) VR101 (R ch) so that the output is within the standard value shown below. (For adjustment point, refer to Fig. 13-11. )22 Standard value:265 mV 300 mV F

47、ig. 13-4.13.6. Erase current confirmation (Deck 2)1. Connect the measuring instrument as shown in Fig. 13-5.2. Insert the blank tape into Deck 2, and press the Record pause button.3. Check if the output at this time between the erase current confirmation point TP301 and TP302 (the output on both edg

48、ed of R313) is within the standard value shown below. (For the erase current confirmation point, referto Fig. 13-11. )Standard ValueEVM readingNormal tape:85 25 mA(85 25 mV)CrO2 tape:150 25 mA(150 25 mV)Metal tape:185 25 mA(185 25 mV)Fig. 13-5.Note:The test tape is not required when confirming the e

49、rase current.13.7. Playback frequency response check (Deck 1/2)1. Connect the measuring instrument as shown in Fig. 13-6.2. Playback the 315 Hz, -20 dB and 12.5 kHz to 63 Hz, -20 dB sections of test tape (QZZCFM) and then, using the 315 Hz, -20 dB playback 23output as a reference (0 dB).3. Confirm t

50、he playback frequency response is within the range shown in Fig. 13-7.Fig. 13-6.Fig. 13-7.13.8. Recording/playback / frequency response and gain check (Deck 2)13.8.1. Normal tape check1. Connect the measuring instrument as shown in Fig. 13-8.2. Insert a Normal type blank tape (QZZCRA4) into Deck 2.3

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 卡座/开盘/组合/收录机 > Technics

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号