Ampeg_svt_csb0003 电路图 维修原理图.pdf

上传人:cc518 文档编号:176552 上传时间:2023-04-30 格式:PDF 页数:2 大小:55.13KB
下载 相关 举报
Ampeg_svt_csb0003 电路图 维修原理图.pdf_第1页
第1页 / 共2页
Ampeg_svt_csb0003 电路图 维修原理图.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

《Ampeg_svt_csb0003 电路图 维修原理图.pdf》由会员分享,可在线阅读,更多相关《Ampeg_svt_csb0003 电路图 维修原理图.pdf(2页珍藏版)》请在收音机爱好者资料库上搜索。

1、SLM Electronics #CSB0003 A Division of St. Louis Music, Inc 11880 Borman DrService Department St. Louis, MO 63146Phone 800 738 7563 Phone 314 569 0141Fax 314 567 7278 November 6, 1997 Customer Service Bulletin Units Affected: SVT-2PROJ units serial numbered T2PJJ40001 through T2PJJ40042 SVT-2PROJ un

2、its serial numbered T2PJJ80001 through T2PJJ80010 SVT-CLJ units serial numbered TCLJJ40001 through TCLJJ40032 SVT-CLJ units serial numbered TCLJJ60001 through TCLJJ60002 SVT-CLJ units serial numbered TCLJJ90001 through TCLJJ90020 Note: A number of units in these serial number ranges have been factor

3、y modified to correct the problem. These units do not need to be modified in the field. They can be identified by the presence of a “Star Quality” label affixed to the outside of the shipping carton adjacent to the serial number/Bar code label. Concern: AC mains fuse for filament transformer would f

4、ail prematurely during normal operation when turning unit on as a result of a design change to use IEC approved fuse beginning with 1/1/97 production. Replacement with larger value fuse would solve false tripping problem but would not always provide adequate protection against damage during severe f

5、ault condition. Corrective Action: Add two each 3A in-rush current limiters (ICLs) that have been prepared with .187” Fast-on connectors (SLME part number 97-123-23) to the filament transformer primary circuit as follows: 1. Disconnect the AC power from the unit. 2. Remove lower chassis assembly fro

6、m cabinet and view from bottom. 3. On the 07-319-xx AC termination PC board, remove blue and gray leads from tabs J17 and J18. 4. Add one 97-123-23 ICL assembly in series with the blue transformer lead and tab J17, and one in series with the gray lead and J18 by attaching the female Fast-on connecto

7、r of ICL to the tab on the printed circuit board and the male Fast-on to transformer lead. 5. Secure the assembly with a cable tie to other AC wires so that no leads are touching other parts. 6. Replace the fuse (F2) with a T1.25A (SLME part number 23-512-05). 7. Remove any fuse label so that “100VA

8、C T1.25A” is visible on the printed circuit board. 8. Reassemble and check out unit for proper operation. 收音机爱好者资料库 Ra d i o Fa n s .CN Note: For best operation of ICLs do not rapidly turn the amplifier off and on. These devices are self- heating and require a short time to cool and return to their protective, “high resistance” state. 07-319-xx AC Termination board as viewed from inside lower chassis Add one 97-123-23 ICL assembly in series with J17 and the blue transformer lead and one in series with J18 and the gray transformer lead. 收音机爱好者资料库 Ra d i o Fa n s .CN