《sony_MDX-C800REC_service_manual 维修电路图.pdf》由会员分享,可在线阅读,更多相关《sony_MDX-C800REC_service_manual 维修电路图.pdf(8页珍藏版)》请在收音机爱好者资料库上搜索。
1、1 SUPPLEMENT-1 File this supplement with the service manual. Subject : Electrical Adjustments SERVICE MANUAL MDX-C800REC AEP Model UK Model E Model 收音机爱好者资料库 Ra d i o Fa n s .CN 2 TEST MODE This set has the test mode functionality. The test mode should be always set before performing adjustments. 1.
2、 Input the specified voltage (14.4 V) to the ACC and BATT terminals. 2. “1:00” is displayed on the LCD display. 3. Press 4 key. 4. Press 5 key. 5. Press 1 key for more than 2 seconds. 6. All segments are lit on the LCD display entering the test mode. 1. Press OFF key. DISPLAY TEST 1. Once the test m
3、ode is set, each pressing of the DSPL key will cause the LCD display to change as follows: All segments ON Press DSPL key. Half segments ON (1) Press DSPL key. Half segments ON (2) (The other half segments that were OFF in (1) are ON.) Press DSPL key. All segments OFF Press DSPL key. TEST MODE STRUC
4、TURE 1. Set the test mode. 2. Insert a disc and press 5 key. 3. Each time 6 key is pressed, the mode will change as follows: ADJUSTMENT mode “SHUF” indication off Press 6 key. PLAY mode “SHUF1” indication is lit. Press 6 key. REC mode “SHUF2” indication is lit. Press 6 key. Unused mode “SHUF ALL” in
5、dication is lit. Press 6 key. ELECTRICAL ADJUSTMENT ADJUSTMENT mode: SHUF indication off KeyDescription of test 2Laser power adjustment mode 3Traverse adjustment mode 4Focus bias adjustment mode 5STOP 6Switch the mode ENTERCLV jitter measurement DSPLSelect the display PLAY mode: SHUF1 KeyDescription
6、 of test 2Laser power check mode 3Focus + CLV ON 4Tracking servo ON/OFF 5STOP 6Switch the mode ENTERCPLAY mode (middle/outer/inner area) DSPLSelect the display REC mode: SHUF2 KeyDescription of test 2Laser power check mode 3Focus + CLV ON 4Tracking servo ON/OFF 5STOP 6Switch the mode ENTERCREC mode
7、(middle/outer/inner area) DSPLSelect the display Unused mode: SHUF ALL 收音机爱好者资料库 Ra d i o Fa n s .CN 3 NOTES FOR ADJUSTMENT 1. Perform the following adjustments as listed when the optical pick- up and IC400, IC402 and/or IC440 in the MD SERVO board have been replaced: (1) Laser power adjustment (2)
8、Traverse adjustment (3) Focus bias adjustment (4) CD error rate check (5) MO error rate check 2. Set the test mode to perform these adjustments. Release the test mode after the adjustments are completed. 3. Perform the adjustments in the order that they are listed. 4. Use the following jigs and meas
9、uring equipment: Test disc (special disc for playback) TDYS-1 (Part No.: 4-963-646-01) Laser power meter LPM-8001 (Part No.: J-2501-046-A) Oscilloscope (Measure after the probe is calibrated.) Digital voltmeter 5. When observing multiple signals with an oscilloscope or other equipment, take care to
10、prevent connection between VC and ground in the oscilloscope. (Otherwise, VC and ground are shorted.) PREPARING A CONTINUOUSLY RECORDED DISC This disc is used for focus bias adjustment and error rate check. This disc is prepared as follows: 1. Set the test mode. (See page 2.) 2. Insert a commercial
11、disc (blank) and press 5 key. 3. Press 6 key twice to set the REC mode. (Verify that the “SHUF2” indication is lit on the LCD display.) 4. Verify that no number is displayed at the disc No. indicator. If any number is displayed, repeatedly press DSPL key until the number disappears (only two digits
12、are displayed). 5. Press ENTER key three times and verify that there is no disc number displayed (the disc is recorded from the inner area). If “3” or “7” is displayed, press ENTER key again to clear the indicator. LCD display 6. Record the data until the disc number indicator shows “9” and then pre
13、ss 5 key to stop recording. 7. Press Z key and take out the disc. The continuously recorded disc for focus bias adjustment and error rate check is now prepared. Note: Take care to prevent vibrations during continuous recording. SHUF 2 Disc No. indicator REC mode 收音机爱好者资料库 Ra d i o Fa n s .CN 4 KMS-2
14、63A 2 7 X 9 3 B 0 8 2 5 (Optical pick-up label) In this case, Iop = 82.5 mA Iop (mA) = Reading on the digital voltmeter (mV)/1 () For the measurement points, see page 7. LASER POWER ADJUSTMENT Connection: Procedure: 1. Connect a digital voltmeter between TP (I+3V) and TP (IOP). 2. Set the test mode.
15、 (See page 2.) 3. Insert a laser power meter into the disc insertion port and press 5 key. 4. Press 2 key. LCD display + optical pick-up objective lens laser power meter digital voltmeter MD servo board TP (I+3V) TP (IOP) 5. Use DISC + or DISC key to adjust so that the reading on the laser power met
16、er is 6.9 to 7.1 mW. 6. Press + M key for 2 seconds to save the data that has been set in step 5. 7. Verify that the digital voltmeter reads out the specified value. Specified value: Reading on the digital voltmeter: Optical pick-up label indication value 10% Mode No. (LD Power Adj.) 7.0 mW power 8.
17、Press 2 key. LCD display 9.Use DISC + or DISC key to adjust so that the reading on the laser power meter is 0.69 to 0.71 mW. 10. Press + M key for 2 seconds to save the data that has been set in step 9. 11. Press 2 key. LCD display Mode No. (LD Power Adj.) 0.7 mW power 12. Verify that the reading on
18、 the laser power meter is 6.0 to 6.4 mW. If outside the specified value, adjust again from step 1. 13. Press 2 key. The laser power adjustment is completed. Mode No. (LD Power Adj.) Main beam conversion power 5 Mode No. (Focus Bias Adj.) Represents the point B measurement Indicates the C1 error rate
19、 Mode No. (Focus Bias Adj.) Represent the point A measurement Indicates the C1 error rate Mode No. (EF-B Adj.) Represents EF adjustment Initial set value Value after automatic adjustment TRAVERSE ADJUSTMENT Connection: Procedure: 1. Connect an oscilloscope between TP (TE) and TP (VC). 2. Set the tes
20、t mode. (See page 2.) 3. Insert the test disc TDYS-1 and press 5 key. 4. Press 3 key. LCD display 5. The traverse is automatically adjusted. Verify that the waveform of the oscilloscope meets the specified value. 6. If outside the specified value, use DISC + or DISC to adjust the waveform. Pressing
21、of DISC + or DISC will cause the value after automatic adjustment to be varied. 7. Press + M key for 2 seconds to save the data set in steps 5 and 6. After saving the data, verify that the initial set value is equal to the value after automatic adjustment. 8. Press 3 key. The traverse adjustment is
22、completed. + oscilloscope V: 0.5 V/div H: 10 ms/div Input: DC mode MD servo board TP (TE) TP (VC) A B VC (Traverse waveform) Specification: A = B FOCUS BIAS ADJUSTMENT Procedure: 1.Set the test mode. (See page 2.) 2.Insert the continuously recorded disc (see page 3.) and press 5 key. 3.Press 4 key a
23、nd check the error rate in the current focus bias setting. LCD display 4.Verify that the first digit of the C1 error rate are “0”. Then, press 4 key. LCD display 5.Press DISC + key until the C1 error rate value reaches “1.00” (Note 1). 6.Press + M key for 2 seconds to save the data set in step 5. 7.
24、Press 4 key. LCD display 8.Press DISC key until the C1 error rate value reaches “1.00” (Note 1). 9.Press + M key for 2 seconds to save the data set in step 8. 10. Press 4 key. LCD display Mode No. (Focus Bias Adj.) Represents the initial measurement Indicates the C1 error rate Mode No. (Focus Bias A
25、dj.) Represents the calculated point C measurement Indicates the C1 error rate 6 11. Verify that the calculated point C error rate is “0.30” or less. If more than “0.30”, adjust again from step 1. 12. Press 4 key. The focus bias adjustment is completed. Note 1) Since the C1 error rate varies, the av
26、erage should be read to perform this adjustment. Note 2) The relationship between C1 error rate and focus bias amount is shown in the figure below. Find out the points A and B in the above adjustment. The total focus point C is automatically calculated from the points A and B. CD ERROR RATE CHECK Pr
27、ocedure: 1. Set the test mode. (See page 2.) 2. Insert the test disc TDYS-1 and press 5 key. 3. Press 6 key to set the PLAY mode. (Verify that the “SHUF1” indication is lit on the display.) 4. Verify that no number is displayed at the disc No. indicator. If any number is displayed, repeatedly press
28、DSPL key until the number disappears (only two digits are displayed). 5. Press ENTER key and verify that the disc No. indicator shows “3”. If “7” is shown or there is no display, repeatedly press ENTER key until “3” is displayed. LCD display 6. Verify that the C1 error rate is “0.30” or less. 7. Pre
29、ss 5 key. The CD error rate check is completed. MO ERROR RATE CHECK Procedure: 1. Set the test mode. (See page 2.) 2. Insert the continuously recorded disc (see page 3.) and press 5 key. 3. Press 6 key to set the PLAY mode. (Verify that the “SHUF1” indication is lit on the display.) 4. Verify that n
30、o number is displayed at the disc No. indicator. If any number is displayed, repeatedly press DSPL key until the number disappears (only two digits are displayed). 5. Press ENTER key and verify that the disc No. indicator shows “3”. If “7” is shown or there is no display, repeatedly press ENTER key
31、until “3” is displayed. LCD display 6. Verify that the C1 error rate is “0.30” or less. 7. Press 5 key. The MO error rate check is completed. 100 BCA C1 error rate Focus bias amount (F. BIAS) SHUF 1 Disc No. indicatorC1 error ratePLAY mode SHUF 1 Disc No. indicatorC1 error ratePLAY mode 7 I+3V IOP VCTE Measurement points: MD SERVO BOARD (SIDE A) 8 MDX-C800REC Sony Corporation Audio Entertainment Group 9-870-144-81 2000F0455-1 Printed in Japan 2000. 6 Published by ME General Engineering Dept.