1、1 MDS-E11/MDS-E52 RS232C INTERFACE MANUAL 1999 by Sony Sound Tec Corporation 01/MDS-E11/E52 P1P799.4.8, 3:55 PM1 收音机爱好者资料库 Ra d i o Fa n s .CN 2 1 Outline 2 Physical connection 3Communication conditions of RS-232C 4 Communication packet format 5 Remote mode 6 Transmission data 6.1Structure of this s

2、ection 6.2REMOTE MODE 6.3POWER 6.4PLAY 6.5STOP 6.6PAUSE ON/OFF 6.7PAUSE ON 6.8FF/REW OFF 6.9REW 6.10FF 6.11PREV TRACK 6.12NEXT TRACK 6.13REC 6.14TIME MACHINE REC 6.15EJECT 6.16AUTO PAUSE 6.17TRACK PLAY 6.18TRACK PAUSE 6.19ELAPSED TIME 6.20DIVIDE MODE REQ 6.21DIVIDE ADJUST 6.22DIVIDE REQ 6.23COMBINE

3、MODE REQ 6.24COMBINE REQ 6.25EDIT MODE CANCEL 6.26ERASE REQ 6.27MOVE REQ 6.28UNDO REQ 6.29MODEL REQUEST 6.30STATUS REQ 6.31DISC DATA REQ 6.32MODEL NAME REQ 6.33REC DATE REQ 6.34TOC DATA REQ 6.35TRACK NO. TIME REQ 6.36DISC NAME REQ 6.37TRACK NO. NAME REQ 6.38ALL NAME REQ 6.39NAME CANCEL 6.40REC REMAI

4、N REQ 6.41NAME REMAIN REQ 6.42DISC NAME WRITE 6.43TRACK NO. NAME WRITE 7 Transmission data 7.1Structure of this section 7.2REMOTE MODE 7.3POWER 7.4PLAY 7.5STOP 7.6PAUSE 7.7REC 7.8REC PAUSE 7.9EJECT 7.10MODEL DATA 7.11STATUS 7.12DISC DATA 7.13MODEL NAME 7.14REC DATE DATA 7.15DISC NAME 7.16TRACK NAME

5、7.17ALL NAME END 7.18ELAPSED TIME 7.19REC REMAIN 7.20NAME REMAIN 7.21TOC DATA 7.22TRACK TIME DATA 7.23DISC EXIST 7.241 TRACK END 7.25NO DISC NAME 7.26NO TRACK NAME 7.27WRITE PACKET RECEIVED 7.28NO TOC DATA 7.29ENTER DIVIDE MODE 7.30ENTER COMBINE MODE 7.31EDIT COMPLETE 7.32DIVIDE POINT DATA 7.33UNDEF

6、INED COMMAND 7.34IMPOSSIBLE 8 Command quick reference 01/MDS-E11/E52 P1P799.4.8, 3:55 PM2 收音机爱好者资料库 Ra d i o Fa n s .CN 3 1Outline This manual has the technical information necessary to control the MDS-E11/E52 with the RS-232C. Section 2Explanation about the connection between DS and PC. Section 3Ex

7、planation about the communication conditions to communicate between the RS-232C and MDS. Section 4Explanation about the packet format to be used for communication between MDS and PC. Section 5Explanation about the remote mode which controls MDS independently of the main unit. Section 6Explanation ab

8、out each command to control MDS. Section 7Quick reference which is the summary from section 1 to 6. In this manual, “MDS” is substituted for MD RECORDER, and “PC” is substituted for the equipment which controls MDS. As for the numbers, the hexadecimal number is shown in Italic with “H” in the end. E

9、xample: 18 (decimal) = 12H (hexadecimal) 01/MDS-E11/E52 P1P799.4.8, 3:55 PM3 收音机爱好者资料库 Ra d i o Fa n s .CN 4 2Physical connection Form of the connector for the RS-232C equipped with MDS, name of the pins and the cables for connection are mentioned in this section. 2-1Form of the connector and name o

10、f the pins D-Sub9 male pin is used in MDS-E11/52 at the RS232C connector. The names of pins are shown as below. Among them, the signal lines of 2:RXD, 3:TXD and 5:GND are connected to MDS. 4:DTR is connected to 6:DSR and 7:RTS is connected to 8:CTS inside MDS. 2-2Connection of the cables necessary f

11、or control Connections as follows are the minimum requirements to control MDS from PC. Pin numberName 1OPEN 2RXD 3TXD 4DTR 5GND 6DSR 7RTS 8CTS 9OPEN Connection cables to meet these requirements are commercially available as what are called “cross cable” or “interlink cable” . The model names of our

12、companys are ; D-Sub9 pin D-Sub25 pin : IF-RS15GDX D-Sub9 pin D-Sub9 pin : IF-IL15GG MDS namePin numberPC namePin number (D-Sub9 male pin)(D-Sub25 female pin) RXD2TXD32 TXD3RXD23 GND5GND57 01/MDS-E11/E52 P1P799.4.8, 3:55 PM4 5 3Communication conditions of RS-232C Communication conditions of RS-232C

13、are shov as follows. Baud rate : 9600 bps Character length : 8 bit Parity : No parity Stop bit : 1 bit Details of data format etc. are explained from section 4 onward. 01/MDS-E11/E52 P1P799.4.8, 3:55 PM5 6 4Communication packet format The packet used in communication between MDS and PC is mentioned

14、in this section. 4-1Packet structure It is changeable data length and composed of the following factors. The maximum packet length is 32 byte. 4-1-1 Header Header is different between the packet transmission directions, that is PC-MDS or MDS-PC. PC-MDS : 7EH MDS-PC : 6FH 4-1-2 Packet length Byte val

15、ue from header to terminator. The maximum packet length, 32 byte, occupies the value in the range from 05H to 20H. 4-1-3 Format type The value of this factor always occupies 05H. 4-1-4 Category The value of this factor always occupies 47H. 4-1-5 Data According to the value of this factor, a control

16、command or a request of condition is sent from PC to MD. And besides, a reply for control command or a current condition is sent from MD to PC. Details about these data is explained from section 6 onward. 4-1-6 Terminator The value of this factor always occupies FFH. 1Header 2Packet length 3Format t

17、ype 4Category 5Data 6Terminator 01/MDS-E11/E52 P1P799.4.8, 3:55 PM6 7 4-2Summary When some data are sent from PC to MDS, packet structure is shown as follows. And besides, when PC receives some data from MDS, packet structure is shown as follows. Details about these data is explained from section 6

18、onward. HeaderPacket lengthFormat typeCategoryDataTerminator 7EHPacket length05H47HData.FFH HeaderPacket lengthFormat typeCategoryDataTerminator 6FHPacket length05H47HData.FFH 01/MDS-E11/E52 P1P799.4.8, 3:55 PM7 8 5Remote mode 5-1What is remote mode? In MDS, processing way for RS-232C is different b

19、etween during remote ON and during remote OFF. To carry out the request from RS-232C, send off the remote ON command at first to set the MDS itself to remote ON mode. When MDS is not in remote ON mode, it does not reply to a command from RS-232C. 5-2Condition of MDS during remote ON MDS with remote

20、ON is capable of accepting any command via RS-232C. When MDS enters remote ON mode, MDS stops all workings and forcibly enters “STOP, REPEAT OFF and CONTINUE mode”. While MDS is remote ON, it accepts controls from RS-232C only and does not accept followings: Keys of main unit Wireless remote control

21、 Wired remote control Parallel remote input Relay playback/recording input (Do not operate keys of main unit during remote ON to avoid malfunctions.) While MDS is remote ON, INPUT switch and REC mode switch (E52 only) can be changed in main unit only. These switches cannot be changed by remote contr

22、ol. While MDS is remote ON, output for the following operation can be done according to an alternation of inside condition: Parallel remote Relay playback/recording input By sending off remote OFF command, MDS enters remote OFF mode. 5-3Condition of MDS during remote OFF When the power is turned on,

23、 MDS is in this mode. While MDS is remote OFF, it accepts followings: Keys of main unit Wireless remote control Wired remote control Parallel remote input Relay playback/recording input 9 As for the command from RS-232C, only remote ON command is acceptable. When MDS receives a command other than re

24、mote ON, it sends back a message means impossible execution. 5-4Summary To control MDS with RS-232C, it is necessary to send remote ON command after turn- ing on the power to enter remote ON mode. MDS does not accept an input other than the one from RS-232C during remote mode. 10 6Transmission data

25、6.1Structure of this section In this section, details about each command are mentioned. The commands are classified as function, data length, data, details of function and example of transmission packet. Function:General functions of commands are shown. Data length:Data length of commands are shown.

26、 Data:A fixed data is shown in hexadecimal notation. As for a variable value, meaning and range of the value are explained. Details of function:Explanation of the function of commands, notation for command use and etc. are mentioned. Example of transmission packet: Concrete examples of transmission

27、packet are shown. 6.2REMOTE MODE Function:To set the remote mode Data length:2 bytes Data:10H, Status Status:03H = On 04H = Off Details of function:This command changes remote mode of MDS. As MDS does not accept controls from RS-232C when remote mode is not ON, it is necessary to use this command to

28、 enter remote ON mode. When remote mode is OFF, if a packet other than the remote mode on is sent from PC, MDS sends back “CANT EXECUTE”. When MDS receives this command, it forcibly enters stop mode, REPEAT OFF or CONTINUE. In this condition, MDS accepts controls from RS-232C until it enters remote

29、mode OFF. 11 In remote ON mode, MDS does not accept keys of main unit, wire- less/wired remote control, parallel input or Relay Play/Rec. On the other hand, parallel output and relay output are carried out. Change of INPUT switch is acceptable even when remote mode is ON. Refer also to section 5 abo

30、ut details of remote mode. Example of transmission packet: Set remote mode to ON. 7EH, 07H, 05H, 47H, 10H, 03H, FFH 6.3POWER Function:To set the power mode Data length:2 bytes Data:01H, Status Status:02H = On 03H = Off Details of function:As well as the POWER button on the remote control, this comma

31、nd switches STANDBY mode and POWER ON mode. When “POWER Off” command is send during toc reading, MDS is turned off after toc reading is completed. However, “Power” comes back immediately from MDS. When the power mode of MDS is actually changed, MDS sends off “STATUS DATA” automatically. “STATUS DATA

32、” is reliable value to grasp the power condition accurately. Example of transmission packet: Set the power to ON. 7EH, 07H, 05H, 47H, 01H, 02H, FFH 6.4PLAY Function:To start playback. Data length:2 bytes Data:02H, 01H 12 Details of function:This command starts playback. When this command is sent in

33、stop mode, MDS starts playback from top of a disc. When this command is sent in playback pause mode, MDS starts playback again from the point. When this command is sent in recording pause mode, MDS starts recording. Example of transmission packet: Start playback. 7EH, 07H, 05H, 47H, 02H, 01H, FFH 6.

34、5STOP Function:To stop playback Data length:2 bytes Data:02H, 02H Details of function:This command stops playback. When this command is sent in playback mode, MDS stops playback. When playback is started again after the above, MDS starts playback from top of a disc. To start playback again from the

35、previous stopping point, “PAUSE ON/OFF” command must be used instead of this “STOP” command. Example of transmission packet: Stop playback. 7EH, 07H, 05H, 47H, 02H, 02H, FFH 6.6PAUSE ON/OFF Function:To pause playback/to cancel pause Data length:2 bytes Data:02H, 03H Details of function:This command

36、has the same function as the PAUSE key in the main unit or the remote control. 13 In short, this command changes playback mode to playback pause mode, and playback pause mode to playback mode. It changes recording pause mode to recording mode, and recording mode to recording pause mode. When this co

37、mmand is sent in stop mode, MDS enters playback pause mode at the top of a disc. Example of transmission packet: Start playback again in playback pause mode. 7EH, 07H, 05H, 47H, 02H, 03H, FFH 6.7PAUSE ON Function:To pause Data length:2 bytes Data:02H, 06H Details of function:This command changes pla

38、yback and recording mode to pause mode. Different from “PAUSE ON/OFF” command, this command does not cancel pause mode. So, if this command is sent during playback pause mode, playback does not start. The similar condition is applied to recording. Example of transmission packet: Pause playback durin

39、g playback mode. 7EH, 07H, 05H, 47H, 02H, 06H, FFH 6.8FF/REW OFF Function:To cancel FF/REW Data length:1 byte Data:00H Details of function:This command stops FF or REW operations during each operations due to FF or REW command. 14 As FF or REW is the command to start operation of FF or REW, the oper

40、ation will carried out to the end of a disc if only these commands are given. “Stop operation during FF or REW”, that is similar condition to the one of when FF or REW key in the main unit is released. Example of transmission packet: Stop FF during FF operation. 7EH, 06H, 05H, 47H, 00H, FFH 6.9REW F

41、unction:To start rewinding Data length:2 bytes Data:02H, 13H Details of function:This command has the same function when REW key in the main unit is pressed. To stop REW, send “FF/REW OFF” command. When this command is sent in playback pause mode, playback start- ing point goes back until “FF/REW OF

42、F” command is given or starting point reaches to the top of the disc. No sound is heard during this period. When this command is sent in playback mode, as well as in playback pause mode, playback starting point goes back until “FF/REW OFF” command is given or starting point reaches to the top of the

43、 disc. Sound is heard in this case. Example of transmission packet: Start REW operation. 7EH, 07H, 05H, 47H, 02H, 13H, FFH 6.10FF Function:To start fast forward Data length:2 bytes Data:02H, 14H 15 Details of function:This command has the same function when FF key in the main unit is pressed. To sto

44、p FF, send “FF/REW OFF” command. When this command is sent in playback pause mode, playback start- ing point goes forward until “FF/REW OFF” command is given or starting point reaches to the end of the disc. No sound is heard during this period. When this command is sent in playback mode, as well as

45、 in playback pause mode, playback starting point goes forward until “FF/REW OFF” command is given or starting point reaches to the end of the disc. Sound is heard in this case. Example of transmission packet: Start FF operation. 7EH, 07H, 05H, 47H, 02H, 14H, FFH 6.11PREV TRACK Function:To skip back

46、to a previous track Data length:2 bytes Data:02H, 15H Details of function:This command has the same function when AMS- key in the main unit is pressed. When this command is sent in the top of a track in playback pause mode, playback starting point goes back to the top of the previous track, and play

47、back pause mode is remained. When this command is sent in the middle of a track in playback pause mode, starting point goes back to the top of the current track, and playback pause mode is remained. When this command is sent during playback, playback starts from the top of the current track. Example

48、 of transmission packet: Start playback from the top of the current track. 7EH, 07H, 05H, 47H, 02H, 15H, FFH 16 6.12NEXT TRACK Function:To skip forward to the next track Data length:2 bytes Data:02H, 16H Details of function:This command has the same function when AMS+ key in the main unit is pressed

49、. When this command is sent during playback, playback starts from the next track. When this command is sent in playback pause mode, starting point goes forward to the top of the next track, and playback pause mode is remained. Example of transmission packet: Start playback from the top of the next track. 7EH, 07H, 05H, 47H, 02H, 16H, FFH 6.13REC Function:To prepare for recording Data length:2 bytes Data:02H, 21H Details of function:This command has the same function when REC button in the main unit is pressed. When this command is sent during playback, playback starts