Icom_RS-BA1_user.pdf

上传人:cc518 文档编号:193775 上传时间:2025-03-06 格式:PDF 页数:28 大小:1.68MB
下载 相关 举报
Icom_RS-BA1_user.pdf_第1页
第1页 / 共28页
Icom_RS-BA1_user.pdf_第2页
第2页 / 共28页
Icom_RS-BA1_user.pdf_第3页
第3页 / 共28页
亲,该文档总共28页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Icom_RS-BA1_user.pdf》由会员分享,可在线阅读,更多相关《Icom_RS-BA1_user.pdf(28页珍藏版)》请在收音机爱好者资料库上搜索。

1、rs-ba1? remote control software quick reference guide 1 C Co on nt te en nt ts s Requirements . 2 Firewall Considerations . 3 Connecting to the RS-BA1 Locally . 4 Finding the IP of your Base Station Computer . 4 Setting up Port Forwarding . 5 Setting up the RS-BA1 Remote Utility Software for the Bas

2、e Station . 8 Connection Errors . 16 Setting up the RS-BA1 Remote Control Software . 17 Accessing the RS-BA1 Remotely over the Internet . 20 Errors Explained . 26 2 R Re eq qu ui ir re emme en nt ts s ? Icom radio with most updated firmware that supports RS-BA1(IC-7600 is being used in our documenta

3、tion) ? A Router for setting up Port forwarding (Linksys RV042 being used in our documentation and is in no way being recommended) ? Desktop Computer that will always remain connected to the Router that is also being used by the Icom radio. This router should be connected directly to the Internet ?

4、Desktop or Laptop computer at the Remote Station that is On the Internet (different Network than the Icom radio network) with exceptions enabled in the Firewall setting. ? CAT-5 Straight cables ? Both Base and Remote Stations computers should have the most latest RS-BA1 driver and software installed

5、 (1.2 or Up) 3 F Fi ir re ewwa al ll l C Co on ns si id de er ra at ti io on ns s The Windows operating system includes a Firewall setting as standard; this is the security function that can prevent improper access through the Internet. To let the Remote Utility work properly, add it as an exception

6、 in the Firewall In the “Allowed programs and features” list, make sure to Add Remote Control and Remote Utility softwares on the Base Station Computer. You can remotely control the radio only if on the Base Station Remote Utility Software is up and running. The software should NOT be connected to t

7、he Radio under Radio list and Server List. When you remotely connect to your radio, this screen will show the BUSY icon. 4 C Co on nn ne ec ct ti in ng g t to o t th he e R RS S- -B BA A1 1 L Lo oc ca al ll ly y Finding the IP of your Base Station Computer 1. Click Start. 2. Click Run. 3. Type “cmd”

8、. 4. Click OK. 5. In the Command window, type “ipconfig”. 6. Press Enter on your keyboard. 5 7. Record your computers IP address. You will need this information later while setting up the RS-BA1 software. In the following example, the Base Station computers IP is 192.168.3.106 Setting up Port Forwar

9、ding 1. Log into your router. The Linksys RV 042 is shown for example purposes only. 2. Click Setup. 3. Click Forwarding. 4. Click the Service Management tab 6 5. Enter RS-BA1 in the Service Name field. 6. Select UDP in the Protocol field. 7. Enter the Port Range from 50001 to 50003. 8. Click Add to

10、 List. 9. Once you see the RSBA 1 in the list, click Update this service. 7 10. Select the RSBA1 UDP port in the Service field. 11. Enter your Base Stations Computer IP in the IP Address field. 12. Click the Enable Checkbox. 13. Click Add to List. 8 14. After your see the RSBA1 ports forwarding box,

11、 Click Save Settings. Setting up the RS-BA1 Remote Utility Software for the Base Station 1. Open the RS-BA1 Remote Utility Software. 2. Select Network Setting. 9 3. Enter your Computers Name in the PC Name field. 4. Choose FTTH in the Internet Access Line field. 5. Click Apply. 6. Close (exit) the R

12、S-BA1 Remote Utility software and open it again. 10 7. Select Server Setting. 8. Click the User List tab. 9. Enter your User ID and password 10. Click the Administrator Checkbox 11. Click Add. Record/save your user ID and password for future reference. 12. Click OK 11 13. Click the Radio List Tab. 1

13、4. Click Add. 15. Enter your radio name in the Radio Name field. 16. Click the CI-V checkbox and enter your CI-V address in the Address field. This information is available in the Instruction manual for your radio or in the Set Mode window. 17. Click the Public Checkbox. 18. Click User Permission. 1

14、2 19. Select your Username from the Radio User Permission box and click Permit. 20. When you see your Username in the Permitted Users field, click OK. 13 21. When using a USB connection between your computer and Icom radio, Click Auto for COM Port/Audio Setting. 22. When setting a COM port manually,

15、 click the Manual Checkbox and select your COM Port in the COM Port Number field. 23. You can look up your COM Port number in the Device Manager window. 14 24. When using a USB headset/mic, select your headset under AF Input / MOD Output Device. Your computer should auto detect your speakers. 25. Cl

16、ick OK. 26. Click the Radio List tab and you will see your radio. 27. Select Radio Operation. 15 28. Select your radio and click Connect. 29. Click OK on the Remote Utility Box (Com port number can be looked up in the Device manager). 16 will appear if the connection is successful. Connection Errors

17、 If you get a error, verify the following: ? Is the COM Port correct? ? Are all cables plugged in the correct connectors? ? Check that all devices are powered. ? The firmware on your Icom radio should be current and that supports the RS-BA1. ? Reboot your computer, sometimes the COM Port (regular an

18、d virtual) requires a PC reboot for complete installation. ? Audio issues can be resolved by selecting the right Output/Input Audio Device in the Settings window (below). This screen appears after clicking Settings. 17 S Se et tt ti in ng g u up p t th he e R RS S- -B BA A1 1 R Re emmo ot te e C Co

19、on nt tr ro ol l S So of ft twwa ar re e 1. Verify that the Remote Control software is turned Off. 2. Click Option and select Connect Setting CLICK CLICK 18 3. At the Connect Setting window, click Model and select your radio (verify the revision number). 4. Click Remote Utility and select your radio

20、. 5. Click COM Port to select your port 6. Enter the address for your model radio in the CI-V address (Radio) field. 7. If using any USB headsets/mic, click Audio Device (Voice Memory) and select your headset/mic. 19 8. Turn the Remote Control Software on. Wait for the software to change its frequen

21、cy. 20 A Ac cc ce es ss si in ng g t th he e R RS S- -B BA A1 1 R Re emmo ot te el ly y o ov ve er r t th he e I In nt te er rn ne et t The following steps are for the Remote Base Station computer only. 1. Click Server List. 2. Click Add. 3. Enter following information: Enter your User name and Pass

22、word* Enter your Base Station Network global IP* Enter your Computer Name * You can check global IP on the Router settings. Or you do a search for “whats my ip” on Google website. * Same Username/Password that you have created previously Click Ok 21 4. You have now created a Server on your Remote co

23、mputer to talk to your Base Station network. 5. Select Server List. 6. Click Connect. 22 If connection is successful, you will see the following window. CONNECTING means you are connected. 7. Click Radio List and you will see your radio come up. 23 8. Click your radio. 9. Click Settings. 10. Click V

24、irtual Com Port Number and select your virtual COM Port ( You can look up your Virtual Comport in the Device Manager). 24 11. Click Save. 12. Click Connect. 13. Click OK on the Remote Utility window. 25 If you see on the window your connection is successful. 14. Open the RS-BA1 Remote Control softwa

25、re on the Remote Station computer and set it up as described in Setting up the RS-BA1 Remote Control Software. 26 Errors Explained You will get the OFFLINE error on the remote computer Utility Software if the Remote Utility software on the Base Station computer is not running. In order to use the Ra

26、dio remotely (over IP), you should have the Remote Utility running (but Not Connected). You will see a BUSY error on the remote computers Utility Software if the Remote Utility on the Base Station computer is connected to the radio (Locally). You wont be able to connect because local Base computer is connected to radio. A Server is out error displays on the remote computers Utility Software when network goes down on the Base station computer and its Remote utility software. 2380 116th Ave NE, Bellevue WA, 98004 ? ? ? ? ? ? ? ? ? ? ?

展开阅读全文