1、CI-V REFERENCE GUIDE i7610 HF/50MHz TRANSCEIVER Table of contents 1 1 Remote control 2 Remote control (CI-V) information 2 D CI-V connection 2 D Preparing 2 D About the data format 2 D Command table 3 D Command formats 10 Remote control 2 Connection example DCI-V connection The transceivers operatin

2、g frequency, mode, VFO and memory selection, can be remotely controlled using a PC. Use a USB cable (A-B type, user supplied) to connect the IC-7610 and the PC (controller). The required USB driver and driver installation guide can be downloaded from the Icom web site. Go to “http:/www.icom.co.jp/wo

3、rld,” and then click “Support,” “Firmware Updates / Software downloads” in sequence. L The download procedure on the web page may be changed without notice. DPreparing The Icom Communications Interface V (CI-V) is used for remote control. To control the transceiver, fjrst set its address, data commu

4、nication speed, and transceive function. These settings are set in Set mode (Refer to the IC-7610 instruction manual). DAbout the data format The CI-V system can be written using the following data formats. Data formats differ according to command numbers. A data area or sub command is added for som

5、e commands. Controller to IC-7610 IC-7610 to controller FE FE98E0CnScData areaFD Preamble code (fixed) Transceivers default address Controllers default address Command number (see the command table) Sub command number (see the command table) BCD code data for frequency or memory number entry End of

6、message code (fixed) FE FEE098FBFD FE FEE098FAFD Preamble code (fixed) Controllers default address Transceivers default address OK code (fixed) End of message code (fixed) NG code (fixed) qwertyu FE FEE098CnScData areaFD qwertyu OK message to controller NG message to controller Remote control (CI-V)

7、 information L Make the connection as short as possible. The transceiver may not be recognized by the controller, depending on the USB cable length. PC Type A Type B To a USB port To the USB 1 port A/B USB cable (user supplied) Cmd. Sub cmd.DataDescription 00see p. 10Send frequency data (transceive)

8、 01see p. 10Send mode data (transceive) 02see p. 10Read band edge frequencies 03see p. 10Read operating frequency 04see p. 10Read operating mode 05see p. 10Set operating frequency 06see p. 10Set operating mode 07Select the VFO mode B0Exchange main and sub bands B1Equalize main and sub bands C0Turn O

9、FF Dualwatch C1Turn ON Dualwatch C2*00 or 01Send/read the dualwatch setting (00=OFF, 01=ON) D0Select the main band D1Select the sub band D2*00Send/read main band selection 01Send/read sub band selection 08Select the Memory mode 0001 to 0099 Select the Memory channel (0001=M-CH01, 0099=M-CH99) 0100Se

10、lect program scan edge channel P1 0101Select program scan edge channel P2 09Memory write 0AMemory copy to VFO 0BMemory clear 0E00Cancel the scan 01Start a Programmed/memory scan 02Start a Programmed scan 03Start a F scan 12Start a Fine programmed scan 13Start a Fine F scan 22Start a Memory scan 23St

11、art a Select memory scan Ax (x=1 to 7) Select F scan span ( x=1 (5 kHz), x=2 (10 kHz), x=3 (20 kHz), x=4 (50 kHz), x=5 (100 kHz), x=6 (500 kHz), x=7 (1 MHz) B0Clear the Select channel setting B1Set as select channel ( The previously set number by CI-V is set after turning power ON, or “1” is selecte

12、d if no selection is performed.) 01 to 03Set the channel as a Select channel (01=SEL1, 02=SEL2, 03=SEL3) B200 to 03Set the Select memory scan channel (00=ALL, 01=SEL1, 02=SEL2, 03=SEL3) D0Set Scan resume OFF D3Set Scan resume ON 0F00Read Split OFF setting 01Read Split ON setting 00Turn OFF the Split

13、 function 01Turn ON the Split function 10*00 to 08Send/read the tuning step ( 00=OFF (10 Hz or 1 Hz), 01=100 Hz, 02=1 kHz, 03=5 kHz, 04=9 kHz, 05=10 kHz, 06=12.5 kHz, 07=20 kHz, 08=25 kHz) 11*00Send/read attenuator OFF setting 03Send/read 3 dB attenuator setting 06Send/read 6 dB attenuator setting 0

14、9Send/read 9 dB attenuator setting 12Send/read 12 dB attenuator setting 15Send/read 15 dB attenuator setting 18Send/read 18 dB attenuator setting 21Send/read 21 dB attenuator setting 24Send/read 24 dB attenuator setting Cmd. Sub cmd.DataDescription 27Send/read 27 dB attenuator setting 30Send/read 30

15、 dB attenuator setting 33Send/read 33 dB attenuator setting 36Send/read 36 dB attenuator setting 39Send/read 39 dB attenuator setting 42Send/read 42 dB attenuator setting 45Send/read 45 dB attenuator setting 12*00*100 or 01Select/read ANT1 selection (00=RX ANT OFF, 01=RX ANT ON) 01*100 or 01Select/r

16、ead ANT2 selection (00=RX ANT OFF, 01=RX ANT ON) 1300Speech all data with voice synthesizer (S meter level, frequency and mode) 01Speech the operating frequency and S meter level by voice synthesizer 02Speech the operating mode by voice synthesizer L The mode is announced after the ongoing speech. 1

17、4*010000 0255 Send/read the AF level (0000=min. to 0255=max.) 020000 0255 Send/read the RF gain level (0000=min. to 0255=max.) 030000 0255 Send/read the squelch level (0000=min. to 0255=max.) 050000 0255 Send/read the APF level (10 Hz steps) ( 0000=Pitch550 Hz, 0128=Pitch, 0255=Pitch+550 Hz) 060000

18、0255 Send/read the NR level (0000=0%, 0255=100%) 070000 0255 Send/read inner TWIN PBT position ( 0000=max. CCW, 0128=center, 0255=max. CW) 080000 0255 Send/read outer TWIN PBT position ( 0000=max. Counter Clockwise, 0128=center, 0255=max. Clockwise) 090000 0255 Send/read CW pitch (5 Hz steps) ( 0000

19、=300 Hz, 0128=600 Hz, 0255=900 Hz) 0A0000 0255 Send/read RF power ( 0000=min. to 0255=max.) 0B0000 0255 Send/read MIC gain ( 0000=min. to 0255=max.) 0C0000 0255 Send/read keying speed (0000=6 wpm to 0255=48 wpm) 0D0000 0255 Send/read Nothc fjlter setting ( 0000=max. Counter Clockwise, 0128=center, 0

20、255=max. Clockwise) 0E0000 0255 Send/read the COMP level (0000=0 to 0255=10) 0F0000 0255 Send/read the Break-IN Delay setting (0000=2.0 d to 0255=13.0 d) 120000 0255 Send/read NB level (0000=0% to 0255=100%) 130000 0255 Send/read the DIGI-SEL shift amount ( 0000=min. to 0255=max.) 140000 0255 Send/r

21、ead DRIVE gain (0000=0% to 0255=100%) 150000 0255 Send/read Monitor audio MONI level (0000=0% to 0255=100%) 160000 0255 Send/read the VOX gain (0000=0% to 0255=100%) 170000 0255 Send/read the Anti VOX gain (0000=0% to 0255=100%) 190000 0255 Send/read LCD backlight brightness (0000=0% to 0255=100%) 1

22、50100 or 01Read noise or S-meter squelch status (00=Close, 01=Open) 020000 to 0255 Read S-meter level (0000=S0, 0120=S9, 0241=S9+60 dB) 0500 or 01Read various squelch (tone squelch, and so on) status (00=Close, 01=Open) DCommand table NOTE: Operation to the some control dials overrides CI-V commands

23、. If a control dial (such as the AF Volume dial that has a mark on it) is rotated after sending a CI-V command, the command will be overwritten by the operation. 11* Remote control 3 Cmd. Sub cmd.DataDescription 0700 or 01Read the Overfmow status ( 00=OVF indicator is OFF, 01=OVF indicator is ON) 11

24、0000 0255 Read the PO meter level (0000=0% to 0143=50% to 212=100%) 120000 0255 Read SWR meter level ( 0000=SWR1.0, 0048=SWR1.5, 0080=SWR2.0, 0120=SWR3.0) 130000 0255 Read ALC meter level (0000=Min. to 0120=Max.) 140000 0255 Read COMP meter level (0000=0 dB, 0130=15 dB, 0241=30 dB) 150000 0255 Read

25、Vd meter level (0000=0 V, 0151=10 V, 0211=16 V) 160000 0255 Read Id meter level ( 0000=0A, 0077=10A, 0165=20A, 0241=30A) 16*0200Preamp OFF 01Preamp 1 ON 02Preamp 2 ON 1201 03Set the AGC time constant (01=FAST, 02=MID, 03=SLOW) 2200 or 01Set the Noise blanker (00=OFF, 01=ON) 3200Audio peak fjlter OFF

26、 01Audio peak fjlter WIDE ON (320 Hz is selected when SHARP APF is set) 02Audio peak fjlter MID ON (160 Hz is selected when SHARP APF is set) 03Audio peak fjlter NAR ON (80 Hz is selected when SHARP APF is set) 4000 or 01Set the Noise reduction (00=OFF, 01=ON) 4100 or 01Set the Auto Notch function (

27、00=OFF, 01=ON) 4200 or 01Set the Repeater tone (00=OFF, 01=ON) 4300 or 01Set the Tone squelch (00=OFF, 01=ON) 4400 or 01Set the Speech compressor (00=OFF, 01=ON) 4500 or 01Set the Monitor MONI function (00=OFF, 01=ON) 4600 or 01Set the VOX function (00=OFF, 01=ON) 4700BK-IN function OFF 01Semi BK-IN

28、 function ON 02Full BK-IN function ON 4800 or 01Set the Manual Notch function (00=OFF, 01=ON) 4E00 or 01Set the DIGI-SEL function (00=OFF, 01=ON) 4F00 or 01Set the Twin peak fjlter (00=OFF, 01=ON) ( Can be turned ON only when Mark and Shift are set to 2125 Hz and 170 Hz, respectively) 5000 or 01Set

29、the Dial lock function (00=OFF, 01=ON) 53*200 or 01Set the ANT-RX I/O (00=OFF, 01=ON) 5600 or 01Set the DSP IF fjlter type (00=SHARP, 01=SOFT) 5700 02Set the Manual Notch width (00=WIDE, 01=MID, 02=NAR) 5800 02Set the SSB transmit bandwidth (00=WIDE, 01=MID, 02=NAR) ( One of following values is appl

30、ied, depending on the “COMP” status (ON or OFF): WIDE (Command: 1A 05 0015), MID (Command: 1A 05 0016) or NAR (Command: 1A 05 0017) 5E00 or 01MAIN/SUB Tracking function (00=OFF, 01=ON) 6500 or 01Set the IP Plus function (00=OFF, 01=ON) D Command table (Continued) Cmd. Sub cmd.DataDescription 17*3see

31、 p. 10Send CW messages 1800Turn OFF the transceiver 01*4Turn ON the transceiver 1900Read the transceiver ID 1A*00see p. 11Send/read memory contents 01see p. 10Send/read band stacking register contents 02*6see p. 13Send/read memory keyer contents 03see p. 12Send/read the selected IF fjlter width 04se

32、e p. 12Send/read the selected AGC time constant 050001see p. 12Tone Control RX Send/read SSB RX HPF/LPF settings 000200 10Tone Control RX Send/read SSB RX Tone (Bass) level (00=5 to 10=+5) 000300 10Tone Control RX Send/read SSB RX Tone (Treble) level (00=5 to 10=+5) 0004see p. 12Tone Control RX Send

33、/read AM RX HPF/LPF settings 000500 10Tone Control RX Send/read AM RX Tone (Bass) level (00=5 to 10=+5) 000600 10Tone Control RX Send/read AM RX Tone (Treble) level (00=5 to 10=+5) 0007see p. 12Tone Control RX Send/read FM RX HPF/LPF settings 000800 10Tone Control RX Send/read FM RX Tone (Bass) leve

34、l (00=5 to 10=+5) 000900 10Tone Control RX Send/read FM RX Tone (Treble) level (00=5 to 10=+5) 0010see p. 12Tone Control RX Send/read CW RX HPF/LPF settings 0011see p. 12Tone Control RX Send/read RTTY RX HPF/LPF settings 0012see p. 12Tone Control RX Send/read PSK RX HPF/LPF settings 001300 10Tone Co

35、ntrol TX Send/read SSB TX Tone (Bass) level (00=5 to 10=+5) 001400 10Tone Control TX Send/read SSB TX Tone (Treble) level (00=5 to 10=+5) 0015see p. 12Tone Control TX Send/read SSB TX bandwidth for wide 0016see p. 12Tone Control TX Send/read SSB TX bandwidth for mid 0017see p. 12Tone Control TX Send

36、/read SSB TX bandwidth for narrow 001800 10Tone Control TX Send/read AM TX Tone (Bass) level (00=5 to 10=+5) 001900 10Tone Control TX Send/read AM TX Tone (Treble) level (00=5 to 10=+5) 002000 10Tone Control TX Send/read FM TX Tone (Bass) level (00=5 to 10=+5) 002100 10Tone Control TX Send/read FM T

37、X Tone (Treble) level (00=5 to 10=+5) 00220000 0255 Function Beep Level (0000=min. to 0255=max.) 002300 or 01Function Beep Level Limit (00=OFF, 01=ON) 002400 or 01Function Beep (Confjrmation) (00=OFF, 01=ON) 002500 or 01Function Band Edge Beep (00=OFF, 01=ON) ( ON = Beep sounds with a default amateu

38、r band) 02Function Band Edge Beep (02=ON (User) 03Function Band Edge Beep (03=ON (User) 0.1 steps) D Command table (Continued) 1A* 051A* 05 Remote control 7 Cmd. Sub cmd.DataDescription 022900 03CW-KEY SET Rise Time (00=2 msec., 01=4 msec., 02=6 msec., 03=8 msec.) 023000 or 01CW-KEY SET Paddle Polar

39、ity (00=Normal, 01=Reverse) 023100 02CW-KEY SET Key Type (00=Straight, 01=Bug, 02=Paddle) 023200 or 01CW-KEY SET MIC Up/Down Keyer (00=OFF, 01=ON) 023300 03RTTY DECODE SET FFT Scope Averaging (00=OFF, 01=2, 02=3, 03=4) 0234see p. 12RTTY DECODE SET FFT Scope Waveform Color 023500 or 01RTTY DECODE SET

40、 Decode USOS (00=OFF, 01=ON) 023600 or 01RTTY DECODE SET Decode New Line Code (00=CR, LF, CR+LF, 01=CR+LF) 023700 02RTTY DECODE SET Diddle (00=OFF, 01=BLANK, 02=LTRS) 023800 or 01RTTY DECODE SET TX USOS (00=OFF, 01=ON) 023900 or 01RTTY DECODE SET Auto CR+LF by TX (00=OFF, 01=ON) 024000 or 01RTTY DEC

41、ODE SET Time Stamp (00=OFF, 01=ON) 024100 or 01RTTY DECODE SET Time Stamp (Time) (00=Local, 01=“CLOCK2 UTC Offset” setting) 024200 or 01RTTY DECODE SET Time Stamp (Frequency) (00=OFF, 01=ON) 0243see p. 12RTTY DECODE SET Font Color (Receive) 0244see p. 12RTTY DECODE SET Font Color (Transmit) 0245see

42、p. 12RTTY DECODE SET Font Color (Time Stamp) 0246see p. 12RTTY DECODE SET Font Color (TX Buffer) 024700 or 01RTTY DECODE LOG Decode Log (00=OFF, 01=ON) 024800 or 01RTTY DECODE LOG Log Set File Type (00=Text, 01=HTML) 024900 03PSK DECODE SET FFT Scope Averaging (00=OFF, 01=2, 02=3, 03=4) 0250see p. 1

43、2PSK DECODE SET FFT Scope Waveform Color 025100 or 01PSK DECODE SET AFC Range (00=8 Hz, 01=15 Hz) 025200 or 01PSK DECODE SET Time Stamp (00=OFF, 01=ON) 025300 or 01PSK DECODE SET Time Stamp (Time) (00=Local, 01=“CLOCK2 UTC Offset” setting) 025400 or 01PSK DECODE SET Time Stamp (Frequency) (00=OFF, 0

44、1=ON) 0255see p. 12PSK DECODE SET Font Color (Receive) 0256see p. 12PSK DECODE SET Font Color (Transmit) 0257see p. 12PSK DECODE SET Font Color (Time Stamp) 0258see p. 12PSK DECODE SET Font Color (TX Buffer) 025900 or 01PSK DECODE LOG Decode Log (00=OFF, 01=ON) 026000 or 01PSK DECODE LOG Log Set Fil

45、e Type (00=Text, 01=HTML) 026100 or 01SCAN SET SCAN Speed (00=SLow, 01=Fast) 026200 or 01SCAN SET SCAN Resume (00=OFF, 01=ON) 02630000 0255 VOICE TX TX LEVEL (0000=0%, 0255=100%) 026400 or 01VOICE TX SET Auto Monitor (00=OFF, 01=ON) 026501 15VOICE TX SET Repeat Time (01=1 sec. to 15=15 sec.) 026600

46、or 01Recorder Set REC Mode (00=TX 0.1 sec steps) 029300 03VOX voice delay (00=OFF, 01=Short, 02=Mid, 03=Long) 029400 or 01APF TYPE (00=SHARP, 01=SOFT) 029500 06APF AF LEVEL (00=0 dB to 06=6 dB) 06see p. 12DATA mode with fjlter set 0700 or 01NTP server access (00=Terminate, 01=Initiate) 08*500 02Read

47、 NTP server access result (00=Accessing, 01=Succeeded, 02=Failed) 0900 or 01AF Mute (00=OFF, 01=ON) 1B*00see p. 13Repeater tone frequency 01see p. 13TSQL tone frequency 1C00*00 or 01Ttransceivers status (00=RX, 01=TX) *When “CI-V Output (for ANT)” (Command: 1C 04) is set to “ON,” automatically outpu

48、ts when changed. 01*00 02Antenna tuner (00=OFF, 01=ON, 02=Tune) 02*00 or 01Transmit frequency monitor (XFC) (00=OFF, 01=ON) 03see p. 10Read transmit frequency ( When “CI-V Output (for ANT)” (Command: 1C 04) is set to “ON,” automatically outputs when changed.) 04*00 or 01CI-V Output (for ANT) (00=OFF

49、, 01=ON) 1A* 051A* 05 Remote control 8 D Command table (Continued) *4 When sending the power ON command (18 01), you need to repeatedly send “FE” before the standard format. The following is the approximate number of needed repetitions. 115200 bps: 150 “FE”s 57600 bps: 75 “FE”s 38400 bps: 50 “FE”s 19200 bps: 25 “FE”s 9600 bps: 13 “FE”s 4800 bps: 7 “FE”s 7 Example: When using 4800 bps F89EFEFEE10810DF