《IC-PCR1000_user.pdf》由会员分享,可在线阅读,更多相关《IC-PCR1000_user.pdf(16页珍藏版)》请在收音机爱好者资料库上搜索。
1、iPCR1000 INSTRUCTION MANUAL COMMUNICATIONS RECEIVER FOR COMPUTER This device complies with Part 15 of the FCC Rules. Operation is sub- ject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interf
2、erence that may cause undesired operation. Downloaded by? Amateur Radio Directory? ? www.hamdirectory.info i IMPORTANT READ ALL INSTRUCTIONSand on-line help care- fully and completely before using the receiver. SAVE THIS INSTRUCTION MANUALThis instruction manual contains important operating instruct
3、ions for the IC-PCR1000 COMMUNICATIONS RECEIVER FOR COMPUTER. USEantenna(s), such as a well-matched 50 antenna and feedline. For radio communications, the antenna is of critical importance, along with sensitivity. SYSTEM REQUIREMENTS IBM PC compatible computer An RS-232C serial port (38400 bps or fa
4、ster) MicrosoftWindows95 or MicrosoftWindows3.1 with appropriate DOS Intel i486DX4 processor or faster (Pentium 100 MHz or faster recommended) At least 16 MB RAM At least 10 MB of hard disk space 640 480 pixel display (800 600 pixel display recommended) FEATURES USER-SELECTABLE INTERFACE Users can c
5、hoose from 3 different operating screens de- pending on their ability level and preference. WIDE FREQUENCY RANGE, MULTI-MODE RECEIVE The IC-PCR1000 has a wide frequency coverage from 0.5 MHz to 1300 MHz* with all mode receive capability. *Some frequency ranges are restricted depending on version. IF
6、 SHIFT The IF shift function is effective in SSB mode for reducing in- terference from nearby signals. It does so by electronically shifting the passband of the IF fi lter. REAL-TIME BANDSCOPE FUNCTION The real-time bandscope function makes it easy to fi nd busy frequencies and also easy to observe
7、receive frequency band conditions. The maximum band width is 200 kHz. NOISE BLANKER VSC (Voice Scan Control) FUNCTION S-METER SQUELCH HIGH PERFORMANCE PLL CIRCUIT A VARIETY OF TUNING STEPS A VARIETY OF SCANS DIGITAL AFC CIRCUIT Versions of the IC-PCR1000 which display “CE” on the serial number seal,
8、 comply with the essential requirements of the 89/336/EEC directive for Electromagnetic Compatibility. ii CAUTIONS RWARNING! NEVERconnect the receiver to an AC outlet. This may pose a fire hazard or result in an electric shock. NEVER connect other than the specifi ed AC adapter to the receiver. This
9、 connection will ruin the receiver. NEVERconnect the receiver to a power source of more than 16 V DC such as a 24 V battery. This connection will ruin the receiver. NEVERallow children to touch the receiver. NEVERexpose the receiver to rain, snow or any liquids. DO NOTuse or place the receiver in ar
10、eas with tempera- tures below 0C (+32F) or above +50C (+122F) or, in areas subject to direct sunlight. AVOIDplacing the receiver in excessively dusty environ- ments. AVOIDthe use of chemical agents such as benzine or al- cohol when cleaning, as they damage the receiver surfaces. For U.S.A. only (FCC
11、 information) CAUTION:Changes or modifications to this receiver, not expressly approved by Icom Inc., could void your authority to oper- ate this receiver under FCC regulations. Class B digital device users This equipment has been tested and found to comply with the limits for a Class B digital devi
12、ce, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment gen- erates, uses and can radiate radio frequency energy and, if not in- stalled and used in accordance with the instruction
13、s, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, th
14、e user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver
15、is connected. - Consult the dealer or an experienced radio/TV technician for help. For Canada only Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any in- terference, including interference that may cause undesired ope
16、ra- tion of the device. IBM is registered trademark of International Business Machines Corporation in the U.S.A. and other countries. Microsoftand Windowsare registered trade- marks of Microsoft Corporation in the U.S.A and other countries. Screen shots produced with permission from Microsoft Corpor
17、ation. All other products or brands are registered trademarks or trademarks of their respective holders. INSTALLATION1 1 IHardware installation Refer to the diagram below for connections. COMMUNICATIONS RECEIVER iC- pcr1000 Ground Remove the protective sheet and attach to a specified place. to an AC
18、 adapter to an RS-232C port Optional speaker (SP-7, SP-10, SP-12) Personal computer Downloaded by? Amateur Radio Directory? ? www.hamdirectory.info 1INSTALLATION 2 IAntenna installation Antennas play a very important role in receiver operation. Connecting a poor quality antenna to the IC-PCR1000 wil
19、l re- sult in less than optimum performance. Select antenna(s), such as a well-matched 50 antenna and feedline. 1.5:1 of Voltage Standing Wave Ratio (VSWR) is recommended for a desired band. Of course, the antenna line should be a coaxial cable. CAUTION:Protect your receiver from lightning by using
20、a lightning arrestor. NOTE: The supplied antenna is a simple plain antenna which may not obtain indicated specifi cations. To obtain maximum performance from the IC-PCR1000, you must purchase an external wide band antenna such as an optional Icom AH-7000 (251300 MHz), etc. Contact your nearest Icom
21、Dealer or Service Center for re- garding optimum antenna locations. The antenna connector type is BNC, so an adapter may be necessary to connect an optional antenna. IGrounding RWARNING: NEVERuse a gas pipe or electrical conduit pipe for grounding. To prevent accidents involving electricity and inte
22、rference from computers, ground the receiver through the GROUND terminal on the rear panel. For best results, connect a heavy gauge cable to a water pipe or long, earth-sunk copper rod. Make the distance between the GND terminal and ground as short as possible. COMMUNICATIONS RECEIVER iC- pcr1000 1I
23、NSTALLATION 3 IAF output level selection The received audio can be input into your computer via the sound card. Before inputting the received audio into the LINE IN con- nector (connector name depends on your sound card), the output level of the EXT-SP must be set properly. Perform as follows: q Rem
24、ove the 8 screws from the cover as shown below. Open the cover. w Select the output level as shown below. - “SPEAKER” for internal speaker. - “PHONES” for PC sound card or headphones. e Replace the 8 screws and cover. r Connect an appropriate cable between IC-PCR1000 and PC. - Plug for EXT-SP is sup
25、plied with the receiver. SPEAKER PHONES COMMUNICATIONS RECEIVER iC- pcr1000 IC-PCR1000 EXT-SP to LINE IN (depends on your sound card) 1INSTALLATION 4 ITNC connection The IC-PCR1000 can receive 9600 bps packet communica- tion (AFSK). Connect the TNC (Terminal Node Controller) as follows. COMMUNICATIO
26、NS RECEIVER iC- pcr1000 TNCPersonal computer IC-PCR1000 to PACKET 1INSTALLATION 5 ISoftware installation NOTE: Before using the program, make a backup copy of the original disk. After making a backup copy, keep the original disk in a safe place. DWindows 95 q Boot up Windows. - Quit all applications
27、 when windows is running. w Insert the backup disk 1 into the appropriate fl oppy drive. e Select Run from the Start menu. r Type the setup program name with full path name, then press the Enter key. (A:SETUP Enter) t Follow the prompts. y Program group IC-PCR1000 appears in the Programs folder of t
28、he Start menu. DWindows 3.1 q Boot up Windows. - Quit all applications when windows is running. w Insert the backup disk 1 into the appropriate fl oppy drive. e Select Run from the File menu of the Program Manager. r Type the setup program name with full path name, then press the Enter key. (A:SETUP
29、 Enter) t Follow the prompts. y Program group IC-PCR1000 appears in the Program Manager. DOn-line help information See the on-line help for software usage. q Click the Contents in the Help menu to bring up the on- line help. w Click the desired information you want to know. DSoftware update informat
30、ion Software update information will be available at the Icom America home page: ISerial port setting Select the RS-232C serial port correctly if the title bar dis- plays “COM port trouble?”. q Before launching the program make sure the IC-PCR1000 interface unit power is turned on (the LED lights wh
31、en power is on). w Launch the IC-PCR1000 software. e Click the POWER button in the tool bar to temporarily pause the program. r Click the PORT button to bring up the RS-232C PORT Number dialog box. t Click the desired port COM number to choose it. y Click the OK button. PANEL DESCRIPTION2 6 ICompone
32、nt screen See the on-line help for more information. q BANK (memory bank) button Used to change the memory bank number indication and memory bank name indication when using the component screen. w BANK (memory bank) indicator Indicates the memory bank (and its name if it has one) being received. e M
33、EMO (memory) indicator Indicates the memory channel (and its name if it has one) being received. r FREQ (frequency) indication Indicates the receive frequency and data as it is being input such as memory channel numbers, etc. t TS (tuning step) indicator This is the frequency increment used when sel
34、ecting a fre- quency using the Main dial and when searching for signals using a scan function. y Numeral buttons (0 to 9) Used to input a receive frequency or memory channel directly. u Mch (memory channel) button Used to set the numeral buttons for memory channel input. i Tuning step buttons Used t
35、o change the tuning step. o Main dial Used to select a receive frequency. !0 MW (memory write) button Writes the current receive frequency into a memory channel. !1 MCL (memory clear) button Used to clear the contents of unneeded memory channels. !2 ENT (enter) button Used to set the numeral buttons
36、 for frequency input. q w e r tyuiio !0!1!2 2PANEL DESCRIPTION 7 !3 BUSY indicator Appears when receiving a signal or when signal noise opens the squelch. !4 Signal meter Indicates the receive signal strength. Also indicates the S- meter squelch receive level set via the SQUELCH scroll bar. !5 Cente
37、r indicators Indicate the tuning level when selecting the 6 kHz or 15 kHz IF fi lter in FM mode. !6 STOP button Cancels scan operation. !7 PROG (program scan) button Used to start/stop program scan. The indicator lamp lights during scan and Program SCAN appears in the Condition in- dicator window. !
38、8 II (scan pause) button Used to pause/resume a scan. When a scan is paused, Pause appears in the Condition indicator window. !9 AUTO (auto memory write scan) button Used to start/stop auto memory write scan. The indicator lamp lights during scan and Auto MW SCAN appears in the Condition indicator w
39、indow. 0 Condition indicator window Indicates the scan function operating condition. When scan temporarily pauses to receive a signal Busy Stop appears. 1 MEMO (memory scan) button Used to start/stop any of the memory scans. The indicator lamp lights during scan and Memory SCAN appears in the Condit
40、ion indicator window. 2 SET button Shows/hides the Setting dialog box used to adjust settings for scan functions, the band scope function and the automatic mode function. !3!4!5!6!7!8 !9 0 1 2345 6789#0#1#2#3#4#5#6#7#8 2PANEL DESCRIPTION 8 3 DELAY TIME scroll bar This sets the period in which a scan
41、 pauses after receiving a signal. Moving the knob to the right increases the period; to the left decreases the period. 4 SPEED (scan speed) scroll bar Sets the speed at which scans search through frequen- cies/memories for signals. Moving the knob to the right in- creases the speed; to the left decr
42、eases the speed. 5 VSC (Voice Scan Control) button Turns the voice scan control function on and off. This function detects whether signals are modulated (contain voice or music components, etc.) or not. 6 AF (audio frequency) GAIN scroll bar Adjusts the audio output. 7 MUTE button Turns the mute fun
43、ction on and off. Used to temporarily mute audio output. 8 SQUELCH scroll bar Adjusts the squelch level. 9 MONI (Monitor) button Turns the monitor function on and off. The monitor function is used to temporarily open the squelch to listen to weak sig- nals. #0 ATT (Attenuator) button Turns the atten
44、uator on and off. #1 AGC (Automatic Gain Control) button Turns the AGC function on and off. #2 NB (Noise Blanker) button Turns the noise blanker function on and off. The noise blanker is used to reduce pulse type noise. #3 AFC (Automatic Frequency Control) button Turns the AFC function on and off. T
45、his function tracks the re- ceive signal when drifting. #4 Center button After moving a signals passband position with the IF-SHIFT scroll bar, this button returns it to the center position. #5 IF-SHIFT (IF shift) scroll bar Sets a signals passband position. Moving the knob to the right sets the pas
46、sband higher, moving the knob to the left sets the passband lower. #6 FILTER (IF fi lter) buttons Change the IF fi lter in use. The WIDE button selects a wider fi lter, the NAR button selects a narrower fi lter. - Usable IF fi lters vary according to receive mode. #7 T (Tone squelch) button Shows/hi
47、des the TONE SQUELCH dialog box for setting tone squelch tone frequencies. #8 Receive mode buttons Select a receive mode. Using the AUT-M button to select au- tomatic mode also selects a receive mode. 2 9 PANEL DESCRIPTION #9 +200k/200k (Max. frequency span value) indicators Indicate the upper and l
48、ower observable frequency limits around a receive frequency. In the diagram, the upper and lower limits are +200 kHz and 200 kHz. $0 Center frequency indicator Indicates the center frequency of the frequency span; this is for the currently received frequency. $1 Frequency span indication Indicates t
49、he frequency span selected with the SPAN+/ but- ton. $2 LIMIT indicator Indicates when the tuning step is greater than the automatic sweep step setting. In the diagram, the tuning step is greater than the automatic sweep step setting and the tuning step (TS) and the sweep step width are not the same. $3 Sweep step indicator Indicates band scope sweep step. $4 STOP button Stops the band scope (sweep) function. $5 START button Starts the band scope (sweep) function which is used to ob- serve signal conditions around the receive frequency. $6 II (sweep pause) button Pauses/resume