Kenwood_RC-D710_user.pdf

上传人:cc518 文档编号:196180 上传时间:2025-03-07 格式:PDF 页数:73 大小:8.87MB
下载 相关 举报
Kenwood_RC-D710_user.pdf_第1页
第1页 / 共73页
Kenwood_RC-D710_user.pdf_第2页
第2页 / 共73页
Kenwood_RC-D710_user.pdf_第3页
第3页 / 共73页
亲,该文档总共73页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Kenwood_RC-D710_user.pdf》由会员分享,可在线阅读,更多相关《Kenwood_RC-D710_user.pdf(73页珍藏版)》请在收音机爱好者资料库上搜索。

1、INSTRUCTION MANUAL CONTROL PANEL RC-D710 Version: 2.10 CONTENTS-1 OPERATING THROUGH REPEATERS .REPEATER- OPERATING THROUGH REPEATERS .1 REPEATER ACCESS .1 Selecting an Offset Direction .1 Selecting an Offset Frequency .1 Activating the Tone Function .1 Selecting a Tone Frequency .2 Automatic Repeate

2、r Offset (K and E Types Only) .2 TRANSMITTING A 1750 Hz TONE .3 REVERSE FUNCTION .3 AUTOMATIC SIMPLEX CHECKER (ASC) .3 TONE FREQUENCY ID .3 MEMORY CHANNELS .MEMORY CH- MEMORY CHANNELS .1 SIMPLEX however, you will hear audio only when the signal contains the same CTCSS tone or DCS code that you selec

3、ted. When using S-meter Squelch, Scan stops when the received signal strength matches or exceeds the S-meter setting. Scan resumes 2 seconds after the signal level drops below the S-meter setting. Pressing and holding PTT causes Scan to temporarily stop if it is functioning on a non TX band. Startin

4、g Scan switches the Automatic Simplex Checker OFF. SELECTING A SCAN RESUME METHOD The transceiver stops scanning at a frequency or Memory channel on which a signal is detected. It then continues scanning according to which resume mode you have selected. You can choose one of the following modes. The

5、 default is Time-operated mode. Time-Operated mode The transceiver remains on a busy frequency or Memory channel for approximately 5 seconds, and then continues to scan even if the signal is still present. Carrier-Operated mode The transceiver remains on a busy frequency or Memory channel until the

6、signal drops out. There is a 2 second delay between signal drop-out and scan resumption. Seek mode The transceiver remains on a busy frequency or Memory channel even after the signal drops out and does not automatically resume scanning. Note: To temporarily stop scanning and monitor weak signals, pr

7、ess the microphone PF key assigned to the Monitor function. Press the PF key again to resume scanning. 1 Enter Menu mode and access Menu 514. 2 Set the Scan Resume mode to TIME (Time-Operated), CARRIER (Carrier-Operated) or SEEK. VFO SCAN VFO Scan monitors all frequencies tunable on the band, using

8、the current frequency step size. 1 Select your desired band. 2 Press VFO (1s). Scan starts at the current frequency. The 1 MHz decimal blinks while scanning is in progress. To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can als

9、o press microphone UP/ DWN. 3 To quit VFO Scan, press VFO again. SCAN-1 SCAN-2 MEMORY SCAN Use Memory Scan to monitor all Memory channels programmed with frequency data. 1 Select your desired band. 2 Press MR (1s). v Scan starts at the current frequency. The 1 MHz decimal blinks while scanning is in

10、 progress. To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone UP/ DWN. 3 To quit Memory Scan, press MR again. Note: At least 2 Memory channels must contain data and must not be locked out of scan. The L0/U

11、0 to L9/U9 Memory channels will not be scanned. You can also start Memory Scan when in Channel Display mode. While Scan is paused on a channel, the channel number blinks. Locking Out a Memory Channel You can select Memory channels that you prefer not to monitor while scanning. 1 Press MR, then rotat

12、e the Tuning control to select your desired channel. 2 Enter Menu mode and access Menu 202. 3 Set the lockout to ON to lock the channel out of the scanning sequence. To cancel lockout, set the lockout to OFF. The icon appears on the display for a channel that has been locked out. Note: The L0/U0 to

13、L9/U9 Memory channels cannot be locked out. GROUP SCAN For the purpose of Group Scan, the 1000 Memory channels are divided into 10 groups, with each group containing 100 channels. Group Scan monitors only the 100 channels which belong to the specific group you are scanning. The channels are grouped

14、as follows: Memory Group Channel Range Memory Group Channel Range 00 995500 599 1100 1996600 699 2200 2997700 799 3300 3998800 899 4400 4999900 999 1 Press MR, then rotate the Tuning control to select a channel in your desired group. 2 Press the Tuning control (1s). Scan starts at the current channe

15、l. The 1 MHz decimal blinks while scanning is in progress. To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone UP/ DWN. 3 To quit Group Scan, press the Tuning control again. Note: At least 2 Memory channels

16、 in the selected group must contain data and must not be locked out of scan. You can also start Memory Scan when in Channel Display mode. While Scan is paused on a channel, the channel number blinks. Memory Group Link Memory Group Link provides you with the ability to link 2 or more Memory channel g

17、roups together to act as a single group when scanning. You can link up to 10 separate groups together, or even add multiple instances of the same group to the group link, to ensure that one group is scanned more often than the other groups. 1 Enter Menu mode and access Menu 203. 2 Press the Tuning c

18、ontrol. The cursor will begin blinking. 3 Rotate the Tuning control to select a group to link. 4 Press the Tuning control to set the group and move the cursor to the right. Press to move the cursor back or to move the cursor to the right. 5 Repeat steps 3 and 4 to link additional groups together. 6

19、When you have entered your desired groups, press to move the cursor to the right, then press the Tuning control to complete the entry and exit Menu mode. You can insert one space by pressing SPACE. You can insert a character by pressing INS. You can delete the selected character by pressing CLR. If

20、you have entered the maximum of 6 groups, simply press the Tuning control to complete the entry and exit Menu mode. SCAN-3 PROGRAM SCAN Program Scan is identical to VFO Scan except that you select a frequency range for the scan. Setting Scan Limits You can store up to 10 scan ranges in Memory channe

21、ls L0/U0 to L9/U9. 1 Press VFO. 2 Select your desired band. 3 Rotate the Tuning control to select your desired frequency for the lower limit. 4 Press F. A memory channel number appears and blinks. 5 Rotate the Tuning control to select a channel from L0 to L9. 6 Press M.IN to set the channel number.

22、The lower limit is stored in the channel. 7 Rotate the Tuning control to select your desired frequency for the lower limit. 8 Press F. 9 Rotate the Tuning control to select a matching channel number from U0 to U9. For example, if you select channel L3 in step 5, select channel U3 here. 10 Press M.IN

23、 to set the channel number. The upper limit is stored in the channel. To confirm the stored scan limits, press MR, then select the L and U channels. Note: The lower limit must be lower in frequency than the upper limit. The lower and upper frequency step sizes must be equal. The lower and upper limi

24、ts must be selected on the same band. Using Program Scan 1 Select your desired band. 2 Press VFO. 3 Rotate the Tuning control to select a frequency within your desired scan range. 4 Press VFO (1s). Scan starts at the current frequency. The 1 MHz decimal blinks while scanning is in progress. To rever

25、se the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microphone UP/ DWN. 5 To quit Program Scan, press VFO again. Note: If the step size differs between the lower limit and upper limit, VFO scan will begin instead of Program S

26、can. If the current VFO frequency is within more than one Program Scan range, the range stored in the smallest channel number is used. MHz SCAN MHz Scan monitors a 1 MHz segment of the band, using the current frequency step size. The current 1 MHz digit determines the limits of the scan. For example

27、, if the current frequency is 145.400 MHz, then the scan range would be from 145.000 MHz to 145.995 MHz (the exact upper limit depends on the current frequency step size). 1 Select your desired band. 2 Press VFO. 3 Rotate the Tuning control to select a frequency within your desired 1 MHz range. 4 Pr

28、ess and hold the Tuning control for 1 second to start scanning. Scan starts at the current frequency. The 1 MHz decimal blinks while scanning is in progress. To reverse the scan direction, turn the Tuning control clockwise (upward scan) or counterclockwise (downward scan). You can also press microph

29、one UP/ DWN. 5 To quit MHz Scan, press the Tuning control again. CALL SCAN Use Call Scan to monitor both the Call channel and either the currently selected VFO frequency or the currently selected Memory channel. 1 Select your desired VFO frequency or Memory channel. 2 Press CALL (1s) to start Call S

30、can. The 1 MHz decimal blinks while scanning is in progress. When scanning a Memory channel, the Call channel on the same band as the selected Memory channel is used for scan. 3 To quit Call Scan, press CALL again. Note: The Memory channel selected is scanned even if it has been locked out of scan.

31、SCAN-4 VISUAL SCAN While you are receiving, Visual Scan allows you to monitor frequencies near the current operating frequency. Visual Scan graphically and simultaneously shows how all frequencies in the selected range are busy. You will see up to 21 segments, for each channel, that represent 7 S- m

32、eter levels (3 segments per level). Determine the scan range by selecting the center frequency and the number of channels. The default number of channels is 61. Selecting the Number of Channels 1 Enter Menu mode and access Menu 515. 2 Set the number of channels to MODE 1 (31ch), MODE 2 (61ch), MODE

33、3 (91ch), or MODE 4 (181ch). Using Visual Scan 1 Select your desired band. 2 Rotate the Tuning control select the operating frequency. This frequency will be used as the center frequency. 3 Press F, VISUAL to start Visual Scan. To halt Scan, press PAUSE. “PAUSE” appears and blinks. Press PAUSE again

34、 to resume. 4 To change the operating frequency, rotate the Tuning control. The displayed frequency changes and the cursor moves. Press SET to use the changed operating frequency as the center frequency. Press RESET to restore the previous operating frequency. 5 To exit Visual Scan, press ESC. Note:

35、 You cannot use the Visual Scan Function under the following circumstances: When the APRS/NAVITRA or Packet mode is turned ON. When only 1 channel has been stored in the memory channels. When using Weather Alert (K models only). If you start Visual Scan in Memory Recall mode, the memory channel freq

36、uencies will be scanned. If you start Visual Scan after recalling the Call channel, the Call channel frequency will be used as the center frequency. If the frequency range specified for Program Scan or Program VFO is narrower than the range specified for Visual Scan, the range for Program Scan or VF

37、O will be used for Visual Scan. Visual Scan stops while transmitting. If you start Visual Scan in one of the following conditions, you cannot receive in the current operating frequency. To use this frequency, press PAUSE to halt Scan. Memory Recall or Call Channel mode. A frequency in the 118, 220,

38、300, or 1200 MHz band was selected in VFO mode. Depending on the transceiver conditions, Visual Scan and the conventional S-meter may indicate different signal strength levels. Cursor S-meter level CTCSS-1 CONTINUOUS TONE CODED SQUELCH SYSTEM (CTCSS) You may sometimes want to hear calls only from sp

39、ecific persons. The Continuous Tone Coded Squelch System (CTCSS) allows you to ignore (not hear) unwanted calls from other persons who are using the same frequency. To do so, select the same CTCSS tone as selected by the other persons in your group. A CTCSS tone is subaudible and is selectable from

40、among 42 tone frequencies. Note: CTCSS does not cause your conversation to be private. It only relieves you from listening to unwanted conversations. USING CTCSS 1 Select your desired band. 2 Press TONE 2 times to activate the CTCSS function. The icon appears on the display when the CTCSS function i

41、s ON. Each press of TONE changes the selection as follows: Tone () CTCSS () DCS () Off (no display). 3 Press F, T.SEL. The current CTCSS frequency appears on the display and blinks. 4 Rotate the Tuning control to select your desired CTCSS frequency. Refer to the table below for the available frequen

42、cies. To exit the CTCSS frequency selection, press ESC. 5 Press any key other than the Tuning control and ESC to complete the setting. 6 When you are called: The transceiver squelch opens only when the selected CTCSS tone is received. When you make a call: Press and hold PTT, then speak into the mic

43、rophone. To cancel CTCSS, press TONE until CT no longer appears on the display. You can also select a CTCSS frequency by using the microphone: 1 Select your desired band. 2 Press TONE 2 times to activate the CTCSS function. The icon appears on the display when the CTCSS function is ON. Each press of

44、 TONE changes the selection as follows: Tone () CTCSS () DCS () Off (no display). 3 Press F, T.SEL. The current CTCSS frequency appears on the display and blinks. 4 Press the key programmed as ENTER. 5 Enter a frequency reference number (01 42) using the microphone keypad. Refer to the table below f

45、or frequencies and their reference numbers. No. Frequency (Hz) No. Frequency (Hz) No. Frequency (Hz) 0167.016110.931186.2 0269.317114.832192.8 0371.918118.833203.5 0474.419123.034206.5 0577.020127.335210.7 0679.721131.836218.1 0782.522136.537225.7 0885.423141.338229.1 0988.524146.239233.6 1091.525151.440241.8 1194.826156.741250.3 12 97.427162.242254.1 13100.028167.9 14103.529173.8 15107.230179.9 CTCSS-2 CTCSS FREQUENCY SCAN This function scans through all CTCSS frequencies to identify the incoming C

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 火腿一族 > Kenwood

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号