1、TS-590S KENWOOD NETWORK COMMAND SYSTEM Setting Manual October/15/2010 2 CONTENTS 1. Relevant Models .3 2. Objectives of this document.3 3. Outline.4 3.1. Overall Configuration.4 3.2. Outline of Host Station (Transmitter) Operations.5 3.3. Host Station (Transmitter) Configuration.6 3.4. Overview of R
2、emote Station (Operator) Operations .8 3.5. Remote Station (Operator) Configuration .9 4. Settings.11 4.1. Connecting Communications Cables.11 4.2. Connecting Audio Cables .11 4.3. Transceiver Settings.13 4.4. Setting Transmission Methods for Audio Input to the Rear Terminal.16 4.5. Setting Broadban
3、d Routers .17 4.6. Software Installation and Settings.18 4.7. Windows Firewall Settings.19 4.8. Comprehensive Security Software Settings.19 4.9. Setting the Host Station Wait Mode .19 4.10. Connecting to the Host Station from the Remote Station.19 5. Limitations Caution! .20 5.1. PC Environment Limi
4、tations .20 5.2. Network Environment Limitations .20 5.3. Program Limitations.21 5.4. Limitations if Using USB Audio Functions.21 6. Frequently Asked Questions .22 Windows is a registered trademark or trademark of Microsoft Corporation in the United States and other countries. .NET Framework is a re
5、gistered trademark or trademark of Microsoft Corporation in the United States and other countries. Bluetooth is a registered trademark or trademark of Bluetooth SIG, Inc. The names of all products described hereafter are the trademarks or registered trademarks of their respective manufacturers. and
6、are omitted throughout the text. Disclaimer: All efforts have been made regarding the accuracy of the contents described in this document. However, there is a possibility of misprints and of descriptions that may cause misunderstanding. Kenwood Corporation bears absolutely no responsibility for dama
7、ges arising thereof. Kenwood Corporation may revise and amend the product information described in this document without notice. Kenwood Corporation bears absolutely no responsibility for damages arising thereof. 3 1. Relevant Models This user guide is for the TS-590S. Using the TS-590S and KENWOOD
8、NETWORK COMMAND SYSTEM (hereinafter called KNS) enables transceiver operations by remote control using a domestic LAN or the internet. (See Note.) KNS is a system configured using PCs, network environments, ARCP-590 (a Radio Control Program) (hereinafter called ARCP-590”), and ARHP-590 (a Radio Host
9、 Program) (hereinafter called “ARHP-590”) for remote control of the TS-590S. Note: To transmit and receive audio, separate VoIP software is required. Important ? To configure the system, knowledge not only of transceivers but also of PCs and networks is required. Kenwood does not offer support for c
10、ustomer computers and Networks. Furthermore, for operations relating to actual transmitting, note that procedures according to the Radio Act are also required. ? Operations via networks may be delayed due to unavoidable principles. Consequently, do not perform operations (such as contests or pile-up
11、s requiring quick responses) for which delays are likely to be a problem. ? Refer to Chapter 5 for other limitations. ? Kenwood Corporation shall bear no responsibility for related damage such as damage caused by missed communications and dialog opportunities due to incorrect customer settings, nonc
12、onformances, or misoperations as a result of using this document or the ARCP-590 or ARHP-590 software. 2. Objectives of this document To supply information to configure a remote control system via an internal LAN or internet using the TS-590S ARCP-590 and ARHP-590. The following describes the main e
13、lements. Via Internet Internal LAN Programs Used ARCP-590 (Operates transceiver remotely.) ARHP-590 (Operates via the ARCP-590 and transceiver.) VoIP software (transmits and receives audio) ARCP-590 (Operates transceiver remotely.) ARHP-590 (Performs operations via the ARCP-590 and transceiver.) VoI
14、P software (transmits and receives audio) Network Connections via the internet (To use the internet, a contract with a provider is necessary.) Connection using internal LAN IP address used Global IP address Local IP address Application based on the Radio Act Application using the internet Applicatio
15、n using internal LAN 4 3. Outline 3.1. Overall Configuration Fig. 3.1.1: Example of internal LAN configuration (In this diagram, the modem, router, and hub have been omitted.) As shown in the diagram, the configuration uses a host station (where the transceiver is installed; this is called the trans
16、mitter in the Radio Act) and a remote station (which performs the remote operations; this is called the operator in the Radio Act). A PC is connected to both, and the PCs are connected to each other via the network. The transceiver connected to the PC to which the ARHP-590 has been installed on the
17、host station is operated using the ARCP-590, which has been installed on the remote station PC. Furthermore, transmitted and received audio for the transceiver on the host station can be transmitted using the mike and speaker connected to the PC sound device on the remote station. (See Note.) Note:
18、To transmit and receive audio, separate VoIP software is required. Remote station Host station TS-590S 5 Fig. 3.1.2: Example of KNS configuration via the internet The host station and remote station can be installed in any location with an internet connection. 3.2. Outline of Host Station (Transmitt
19、er) Operations The host station is configured using a transceiver and a PC connected to the network. Data signals that control the transceiver are connected to the PC using either RS-232C or USB. The computer uses its sound function to input and output audio transmitted and received by the transceiv
20、er, and converts them between digital and analog signals. The ARHP-590 is installed on the computer and exchanges transceiver control data signals with the network. The PCs are connected to the network, and trade transceiver control data signals and transmit and receive audio with the Remote station
21、 (operator) on the network. Note: To transmit and receive audio, separate VoIP software is required. 6 3.3. Host Station (Transmitter) Configuration Transceiver TS-590S The TS-590S transceiver is supported. The ARCP-590 and ARHP-590 are specialized for the TS-590S, and so other transceivers cannot b
22、e used to configure the system. USB or RS-232C Controls that change the frequency or mode are performed by connecting the transceiver and PC using either a USB cable or RS-232C cable. (The transceiver has only one RS-232C terminal, so if using the RS-232C terminal for KNS operations, another device
23、cannot be connected.) Connection Audio Created by the customer. To transmit and receive audio, connect the wireless ACC2 terminal to the PC sound I/O terminal. For the transceiver terminal specifications, refer to the device user manual, and for the cable creation and connection methods, refer to 4.
24、2. Connecting Audio Cables. Specifications CPU and memory: Minimum values recommended by the operating system. HDD: To install the ARHP-590, a minimum of approx. 100 MB of free disk space is required. If storing connection logs, additional memory space is required. Sound function To transmit and rec
25、eive audio, a sound function is required. PC Network function Connects to the internal LAN. To perform KNS operations via the internet, connect to a network that is connected to the internet. A cable network is recommended. Software OS Use Windows XP (SP3 or later), Windows Vista (SP1 or later, 32-b
26、it version only), or Windows 7 (32-bit or 64-bit version). Other operating systems are not compatible. (Transceiver control) Transceiver Sound function Audio transmission VoIP software 7 Run-time To use KNS on Windows XP, Microsoft .NET Framework 2.0 or later is required. If it is not installed, ins
27、tall it when installing ARHP-590. ARHP-590 This software controls the transceivers. Refer to the software help for the settings and operation methods. Download the software from the download page, and install on the PC. VoIP software To transmit and receive audio, VoIP software is required. (See Not
28、e 1.) Router To implement KNS operations via the internet, a model on which port forwarding settings are possible using the following protocol is required to transmit the data signals that control the transceiver. (See Note 2.) Protocol: TCP; port No.: 50000 (KNS default value) Modem Not specified.
29、LAN environment Other To implement KNS operations via the internet, firewall environments configured using in-house company networks cannot be used. Use a domestic network environment. Provider To implement KNS operations via the internet: A high-speed cable broadband environment using xDSL, FTTH, o
30、r CATV network is required. (1Mbps min. recommended.) A global IP address is required. (See Note 3.) The ability to use protocols and ports to transmit the data signals that control the transceiver is required. Protocol: TCP Port No.: 50000 (KNS default value) For details, contact your internet serv
31、ice provider. Internet environment Proxy Proxy servers cannot be used. Note 1: Support for selecting, installing, and operating VoIP software is not available from Kenwood Corporation. Note 2: Make sure to refer to the user manual for the broadband router to be used before performing the settings. N
32、ote 3: KNS operations are possible even if the global IP address is variable, but the IP address may change with uncertain timing. In such cases, it is necessary to check and change the IP address of the connected host when connected from a remote station, which reduces user-friendliness. Consequent
33、ly, using an environment in which the host station global IP address is fixed is recommended. Furthermore, if the global IP address cannot be fixed, using a dynamic DNS service enables operations in the same way as an environment with a fixed global IP address. 8 3.4. Overview of Remote Station (Ope
34、rator) Operations The remote station is configured using a PC connected to the network, and a microphone and speaker connected to the PC sound function. The audio transmissions for the host station transceiver are input and output using the microphone and speaker connected to the sound function of t
35、he remote station PC via the network. The ARCP-590 is installed in the PC. The host station transceiver connected via the network is controlled by remote station ARCP-590 operations. (See Note.) Note: To transmit and receive audio, separate VoIP software is required. 9 3.5. Remote Station (Operator)
36、 Configuration PC ?機能 ARCP-59? ?oIP? 送信音声 受信音声 LAN?AN Connection Audio To exchange audio transmissions, connect the microphone and speaker or a headset to the PC sound function. Use products compatible with the sound function used. Specifications CPU and memory: Minimum values recommended by the ope
37、rating system. HDD: To install the ARCP-590, a minimum of approx. 100 MB of free disk space is required. If saving transceiver settings to data files, or saving keystroke logs, additional memory space is required. Sound function To exchange audio transmissions, a sound function is required. PC Netwo
38、rk function A cable network is recommended. Connect to a hub or router. OS Use Windows XP (SP3 or later), Windows Vista (SP1 or later, 32-bit version only), or Windows 7 (32-bit or 64-bit version). Other operating systems are not compatible. Run-time To use KNS operations on Windows XP, Microsoft .N
39、ET Framework 2.0 or later is required. If it is not installed, install it when installing ARCP-590. ARCP-590 This software remote controls the transceivers. Refer to the software help for the settings and operation methods. Download the software from the download page, and install on the PC. Softwar
40、e VoIP software To transmit and receive audio, VoIP telephone software is required. (See Note 1.) Transmit audio Receive audio Sound function VoIP software 10 Router Same as host station. Modem Same as host station. LAN environment Firewall Same as host station. Provider Same as host station. Intern
41、et environment Proxy Same as host station. Note 1: Support for selecting, installing, and operating VoIP software is not available from Kenwood Corporation. 11 4. Settings 4.1. Connecting Communications Cables Connect the host station PC and TS-590S using an RS-232C or USB cable. Note: RS-232C cable
42、s and USB cables are sold separately. Purchase them from a commercial outlet. If connecting using an RS-232 cable, ensure that it is a straight cable (9 pin to 9 pin). If connecting using a USB cable (1) Download the installer for the virtual COM port driver from the Kenwood homepage , then install it according to the procedures. (2) Connect the PC and TS-590S using the USB cable. 4.2. Connecting Audio Cables To transmit and receive audio, an audio cable is required. Create an audio cable using the 13-pin DIN plug enclosed with the TS-590S with refer