《AN-GRC-213_serv_user_TM11-5820-923-12_1986.pdf》由会员分享,可在线阅读,更多相关《AN-GRC-213_serv_user_TM11-5820-923-12_1986.pdf(176页珍藏版)》请在收音机爱好者资料库上搜索。
1、TM 11-5820-923-12 TECHNICAL MANUAL OPERATORS AND ORGANIZATIONAL MAINTENANCE MANUAL RADIO SET AN/GRC-213 (NSN 5820-01-128-3935) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT OF THE ARMY 14 FEBRUARY 1986 CHANGE No. 2 TM 11-5820-923-12 C 2 HEADQUARTE
2、RS DEPARTMENT OF THE ARMY Washington, DC, 1 September 1990 Operators and Organizational Maintenance Manual AN/GRC-213 (NSN 5820-01-128-3935) TM 11-5820-923-12, 14 February 1986, is changed as follows: 1. Remove old pages and insert new pages as indicated below. New or changed material is indicated b
3、y a vertical bar in the margin of the page. Added or revised illustrations are indicated by a vertical bar adjacent to the identification number. Remove pagesInsert pages A and B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A through C/(D blank) i and ii . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i and ii l-1 through 1-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 through l-4 2-l and 2-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-l and 2-2 2-15/(2-16 blank) . . . . . . . . . .
5、 . . . . . . . . . . . . . . . . . . . . 2-15/(2-16 blank) 4-15 and 4-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-l5 and 4-l6 A-1 through A-3/(A-4 blank) . . . . . . . . . . . . . . . . . . . A-1 through A-3/(A-4 blank) C-3 and C-4 . . . . . . . . . . . . . . . . . . . .
6、 . . .C-3 and C-4 C-9 and C-10 . . . . . . . . . . . . . . . . . . . . . . .C-9 and C-10 2. File this change sheet in the publication for reference purposes. Distribution authorized to the Department of Defense and DOD contractors only for official use or for administrative or operational purposes.T
7、his determination was made on 31 May 1990.Other requests for the document will be referred to Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: AMSEL-LC-ME-P, Fort Monmouth, NJ 07703-5000. DESTRUCTION NOTICE- Destroy by any method that will prevent disclosure of contents
8、 or reconstruction of the document. By Order of the Secretary of the Army: CARL E. VUONO General, United States Army Chief of Staff Official: THOMAS F. SIKORA Brigadier General, United States Army The Adjutant General DISTRIBUTION: To be distributed in accordance with DA Form 1251-E, block 1452, Ope
9、rator and Unit Maintenance requirements for TM 11-5820923-12. TM 11-5820-923-12 C 1 CHANGE N o . 1 HEADQUARTERS D E P A R T M E N T O F T H E A R M Y W A S H I N G T O N ,DC, 1 January 1989 Operators and Organizational Maintenance Manual AN/GRC-213 (NSN 5820-01-128-3935) TM 11-5820-923-12, 14 Februa
10、ry 1986, is changed as follows: 1. Remove old pages and insert new pages as indicated below. New or changed material is indicated by a vertical bar in the margin of the page.A d d e d o r r e v i s e d i l l u s t r a t i o n s a r e i n d i c a t e d b y a v e r t i c a l b a r a d j a c e n t t o
11、t h e i d e n t i f i c a t i o n n u m b e r . Removepages I n s e r tpages C-5 and C-6C-5 and C-6 2 . F i l e t h i s c h a n g e s h e e t i n f r o n t o f t h e p u b l i c a t i o n f o r r e f - erence purposes. Distribution authorized to the Department of Defense and DOD contractors only for
12、 official use or for administration or operational purposes. This determination was made on 5 July 1988. Other requests for this document will be referred to Commander, US Army Communications-Electronics Command and Fort Monmouth, Attn: AMSEL-LC-ME-P, Fort Monmouth, NJ 07703-5000. DESTRUCTION NOTICE
13、Destroy by any method that will prevent disclosure of contents or reconstruction of the document. By Order of the Secretary of the Army: Official: WILLIAM J. MEEHAN II Brigadier General, United States Army The Adjutant General CARL E. VUONO General, United States Army Chief of Staff DISTRIBUTION: To
14、 be distributed in accordance with DA Form 12-51 Operator and Unit requirements for AN/GRC-213. TM 11-5820-923-12 SAFETY STEPS TO FOLLOW IF SOMEONE IS THE VICTIM OF ELECTRICAL SHOCK DO NOT TRY TO PULL OR GRAB THE INDIVIDUAL IF POSSIBLE, TURN OFF THE ELECTRICAL POWER IF YOU CANNOT TURN OFF THE ELECTR
15、ICAL POWER, PULL, PUSH, OR LIFT THE PERSON TO SAFETY USING A DRY WOODEN POLE OR A DRY ROPE OR SOME OTHER INSULATING MATERIAL SEND FOR HELP AS SOON AS POSSIBLE AFTER THE INJURED PERSON IS FREE OF CONTACT WITH THE SOURCE OF ELECTRICAL SHOCK, MOVE THE PERSON A SHORT DISTANCE AWAY AND IMMEDIATELY START
16、ARTIFICIAL RESUSCITATION Change 2A TM 11-5820-923-12 Dangerous voltages exist in power lines.Do not allow antenna to touch power lines. Antenna installation area must be free of power lines.Antenna contact with power lines during installation may cause serious injury or even DEATH to operator. If yo
17、u must erect antenna near power lines, power line poles or towers, or buildings with overhead power line connections, never put the antenna closer than two times the antenna height from the base of the power line, pole, tower, or buildings. Tie antenna down before moving vehicle.When vehicle is in m
18、otion, do not allow anyone to stick an arm, leg, or weapon over the sides of the vehicle.If the antenna accidentally touches a power line and a leg, arm, or weapon contacts a damp bush or the ground, a serious or fatal accident can occur. If you suspect that power Iines have made accidental contact
19、with your antenna, stop operating, rope off the antenna area, and notify your superiors. For first aid, refer to FM 21-11. Operation in marginal weather where electrical activity is possible may be dangerous to the operator or occupants of the vehicle. For first aid, refer to FM 21-11. Do not smoke
20、or use flame near fuel or vehicle fuel system. Fire or explosion may occur, causing personal injury or DEATH. Dangerous rf voltages exist around antennas and antenna terminals during transmission. Protect yourself by knowing the safety procedures in TB SIG 291. Do not store lithium battery, BA-5590/
21、U, in transit case longer than 30 days. After 30 days, the battery may discharge, overheat, and vent hazardous sulfur dioxide fumes. (See C/(D blank) When using acompressed airjet, use eyeshields to prevent severe eye injury. BChange 2 TM 11-5820-923-12 WARNING LITHIUM BATTERIES A lithium battery is
22、 used in this equipment and is potentially hazardous if misused or tampered with before, during, and after discharge. The following precautions must be strictly observed to prevent possible in- iury to personnel or damage to equipment. DO NOT USE unauthorized batteries or damaged batteries and dispo
23、se of any batteries showing signs of damage. DO NOT USE lithium batteries in parallel circuitry unless the batteries or equipment are diode protected. DO NOT short circuit. DO NOT test for capacity or recharge. DO NOT bypass internal fuse or replace with a fuse of a different rating. DO NOT store in
24、 equipment during long periods when not in use. TURN OFF the equipment immediately if you detect the battery compart- ment becoming unduly hot or rapidly increasing in temperature, hear battery venting (hissing sound), or smell irritating sulfur dioxide gas. Remove and dispose of the battery only af
25、ter it is cool (at least 60 minutes). DO NOT use carbon dioxide extinguishers on exposed lithium metal fires. Flood the burning material with water or use graphite type com- pounds or extinguishers to extinguish burning lithium. REMOVE THE BATTERY WHEN THE EQUIPMENT DOES NOT OPERATE PRO- PERLY AND R
26、EPLACE WITH A NEW BATTERY. DISPOSE OF SPENT LITHIUM BATTERIES THROUGH THE LOCAL SERVIC- ING DEFENSE REUTILIZATION AND MARKETING OFFICE (DRMO). Change 2 C/(D blank) Technical Manual No. 11-5820-923-12 TM 11-5820-923-12 HEADQUARTERS DEPARTMENT OF THE ARMY Washington, DC, 14 February 1986 Operators and
27、 Organizational Maintenance Manual AN/GRC-213 (NSN 5820-01-128-3935) REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS You can help improve this manual. If you find any mistakes or if you know of a way to improve the procedures, please let us know, Mail your letter, DA Form 2028 (Recommended Changes to
28、 Publications and Blank Forms), or DA Form 2028-2 located in back of this manual direct to: Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: AMSEL-LC-ME-PS, Fort Monmouth, New Jersey 07703-5000. In either case, a reply will be furnished direct to you. Page List of lllus
29、trations . . . . . . . . . . . . . . . . . . . . . . . . . . . List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i v i v CHAPTER 1. Section I. 1-1. 1-2. 1-3. 1-4. 1-5. 1-6. 1-7. Section Il. 1-8. 1-9. 1-10. 1-11. Section Ill. 1-12 1-13. 1-14. INTRODUCTION . . . . . . . . . .
30、. . . . . . . . . . General Information . . . . . . . . . . . . . . . . . . Scope . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance Forms, Records, and Reports . . . . . . . . . Consolidated Index of Army Publications and Blank Forms . . Hand Receipt (-HR) and Related Technical Manuals .
31、 . . . . Destruction of Army Electronics Materiel to Prevent Enemy Use . . . . . . . . . . . . . . . . . . . . . Adminstrative Storage Reporting Equipment Improvement Recornrnendations (EIR) . . Equipment Description . . . . . . . . . . . . . . . . . Purpose and Function . . . . . . . . . . . . . .
32、. . . . Capabilities and Features . . . . . . . . . . . . . . . . Difference Between Models . . . . . . . . . . . . . . . Equipment Specifications . . . . . . . . . . . . . . . . Equipment and Tools Lists. . . . . . . . . . . . . . . . Equipment Supplied . . . . . . . . . . . . . . . . . . . Equipme
33、nt Required But Not Supplied . . . . . . . . . . . Special Tools and Test Equipment . . . . . . . . . . . . . 1-1 1-1 1-1 1-1 1-1 1-1 1-4 1-4 1-4 1-5 1-5 1-5 1-6 1 - 6 1-10 1-10 1-10 1-10 Change 2i TM 11-5820-923-12 Page CHAPTER 2. Section I. 2-1. 2-2. Section Il. 2-3. 2-4. 2-5. CHAPTER 3. Section I
34、. 3-1. 3-2. 3-3. 3-4. Section Il. 3-5. 3-6. 3-7. 3-8. 3-9. 3-10. 3-11. 3-12. CHAPTER 4. 4-1. Section I. 4-2. 4-3. Section Il. 4-4. CHAPTER 5. Section I. 5-1. 5-2. 5-3. 5-4. Section Il. 5-5. 5-6. PREPARATION FOR USE AND INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . Preparation for U
35、se. . . . . . . . . . . . . . . . . . Unpacking . . . . . . . . . . . . . . . . . . . . . . Mounting . . . . . . . . . . . . . . . . . . . . . . . Connections . . . . . . . . . . . . . . . . . . . . . . Interconnections . . . . . . . . . . . . . . . . . . . . Grounding Requirements . . . . . . . . .
36、 . . . . . . . Minimum Performance Test . . . . . . . . . . . . . . . OPERATING INSTRUCTIONS . . . . . . . . . . . . . . Controls, Visual and Audible Indicators, and Connectors . . . General . . . . . . . . . . . . . . . . . . . . . . . . Controls and lndicators . . . . . . . . . . . . . . . . . Aud
37、ible Indicators . . . . . . . . . . . . . . . . . . . Connectors . . . . . . . . . . . . . . . . . . . . . . Operation . . . . . . . . . . . . . . . . . . . . . . . Operating Considerations . . . . . . . . . . . . . . . . Initial Checks . . . . . . . . . . . . . . . . . . . . . initial Control Setti
38、ngs . . . . . . . . . . . . . . . . . Startup . . . . . . . . . . . . . . . . . . . . . . . . Operation Under Normal Conditions . . . . . . . . . . . . Operation under Radio Silence . . . . . . . . . . . . . . Operation Under Unusual Conditions . . . . . . . . . . . Shutdown . . . . . . . . . . . .
39、. . . . . . . . . . . THEORY OF OPERATION . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . AN/GRC-213 General Functional Description . . . . . . . AN/GRC-213 General Functional Description . . . . . . . AN/VIC-1(V) Interface General Functional Description . . .
40、 AN/GRC-213 Detailed Functional Description . . . . . . . AN/GRC-213 Detailed Functional Description . . . . . . . OPERATOR MAINTENANCE . . . . . . . . . . . . . . . Operator Preventive Maintenance, Checks, and Services . . . General . . . . . . . . . . . . . . . . . . . . . . . . Daily Visual Inspe
41、ction . . . . . . . . . . . . . . . . . Daily Minimum Performance Test . . . . . . . . . . . . . Weekly Battery Pack Inspection . . . . . . . . . . . . . Operator Maintenance . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . Cleaning and Corrosion Control Inst
42、ructions . . . . . . . 2-1 2-1 2-1 2-1 2-13 2-13 2-15 2-15 3-1 3-1 3-1 3-1 3-3 3-4 3-7 3-7 3-9 3-11 3-12 3-12 3-15 3-16 3-16 4-1 4-1 4-2 4-2 4-4 4-8 4-8 5-1 5-1 5-1 5-1 5-2 5-2 5-4 5-4 5-4 ii TM 11-5820-923-12 CHAPTER 6. Section I. Section Il. 6-1. 6-2. 6-3. 6-4. 6-5. 6-6. 6-7. 6-8. CHAPTER 7. 7-1.
43、7-2. APPENDIX A. B. C. D. E. ORGANIZATIONAL MAINTENANCE . . . . . . . . . . . Organizational Preventive Maintenance, Checks, and Services . . . . . . . . . . . . . . . . . . . . . Organizational Maintenance . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . Common
44、Tools and Test Equipment . . . . . . . . . . . . Special Tools, TMDE, and Support Equipment . . . . . . . . Materials . . . . . . . . . . . . . . . . . . . . . . . Repair Parts . . . . . . . . . . . . . . . . . . . . . . Fault Isolation . . . . . . . . . . . . . . . . . . . . . Removal and Replaceme
45、nt Instructions . . . . . . . . . . Minimum Performance Test . . . . . . . . . . . . . . . PREPARATION FOR STORAGE OR SHIPMENT . . . . . . Preparation for Shipment . . . . . . . . . . . . . . . . Storage . . . . . . . . . . . . . . . . . . . . . . . . REFERENCES . . . . . . . . . . . . . . . . . . .
46、 . . MAINTENANCE ALLOCATION CHART . . . . . . . . . . COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS LISTS . . . . . . . . . . . . . . . . . . . . ADDITIONAL AUTHORIZATION LIST . . . . . . . . . . EXPENDABLE/DURABLE SUPPLIES AND MATERIALS LIST . Page 6-1 6-1 6-2 6-2 6-2 6-2 6-2 6-2 6-2 6-18 6-33 7-1 7
47、-1 7-3 A-1 B-1 C-1 D-1 E-1 iii TM 11-5820-923-12 LIST OF ILLUSTRATIONS FigureTitle Page 1-1. 2-1. 2-2. 2-3. 2-4. 2-5. 2-6. 2-7. 2-8. 2-9. 2-10. 2-11. 3-1. 3-2. 3-3. 3-4. 4-1. 4-2. 4-3. 4-4. 4-5. 4-6. 4-7. 5-1. 5-2. 6-1. 6-2. 6-3. 6-4. 6-5. 6-6. 7-1. Table 1-1. 1-2. 1-3. 1-4. 2-1. 3-1. 3-2. Radio Set
48、 AN/GRC-213 (2 Sheets) . . . . . . . . . . . Latching of Receiver/Exciter and Amplifier/Coupler . . . Mounting Diagram . . . . . . . . . . . . . . . . . . NVIS Antenna Installation . . . . . . . . . . . . . . . Connecting RF Cable and Antenna Wires to Insulator . . . Use of Tape Measure to Determine
49、 Antenna Wire Length . . Unwinding Antenna Wire from Reel Assembly . . . . . . Attaching Halyard to Reel Assembly . . . . . . . . . . Two-Support Dipole Antenna . . . . . . . . . . . . . . Sloping Dipole Antenna . . . . . . . . . . . . . . . . Inverted V Dipole Antenna . . . . . . . . . . . . . . Connector/Cable Location Diagram for Installation . . . . Controls and Indicators . . . . . . . . . . . . . . . . Connectors . . . . . . . . . . . . . . . . . . . . . Antenna Comparison . . . . . . . . . . . . . . . . . Controls, Indicators, and Connectors for Operation . . . . AN/GRC-