1、For DX Enthusiasts HF/50MHz TRANSCEIVER CA-336K-E-12 JVCKENWOOD USA Corporation Communications Sector Headquarters 1440 Corporate Drive, Irving, TX 75038-2401 Order Administration / Distribution P.O. BOX 22745, 2201 East Dominguez St., Long Beach, CA 90801-5745 JVCKENWOOD Canada Inc. Canadian Headqu

2、arters and Distribution 6070 Kestrel Road, Mississauga, ON, L5T 1S8, Canada KENWOOD SKY COMMAND SYSTEM II is a registered trademark of JVCKENWOOD Corporation in the U.S. JVCKENWOOD follows a policy of continuous advancement in development. For this reason, specifications may be changed without notic

3、e. *Alterations may be made without notice to improve the ratings or the design of the transceiver. *The photographic and printing processes may cause the coloration of the transceiver to appear different from that of the actual transceiver. BDR 150dB 3rd IMDR 110dB RMDR 122dB * * * *: 2 kHz spacing

4、 measurement standard - Receiver frequency 14.2 MHz, MODE CW, BW 500 Hz, PRE AMP OFF 32 The most rewarding results often take place when faced with the harshest and most challenging conditions. There are enthusiasts who know this all too well because of their love of DX. KENWOOD has the answer. Achi

5、eve results through certainty and not circumstance. Delivered through impeccable receiver and audio performance. This is our offering to you. Performance Exceeding Expectations. 15.59(W)5.56(H)13.38(D)in (not including protrusions) 54 1st Local OSC Phase Noise (14.1MHz) Values are measured examples.

6、 HMC829 DSP FPGA ADC RF BPF Band scope receiver through H-mode Mixer Post Amp Roofing Filters Receive signal system Down conversion receiver BPF ATT PRE AMP 270Hz (Option) 500Hz 2.7kHz 6kHz 15kHz ATT PLL PLL VCO Div.1 Div.2 19.2 MHz 100 MHz 3218.112 MHz 22.348 MHz 1st local oscillator frequency 0.1

7、ppm TCXO Frequency Offset kHz Blocking Dynamic Range 1012100 dB 20 dB 40 dB 60 dB 80 dB 120 dB 140 dB 100 dB 160 dB Frequency Offset Hz 1st Local OSC Phase Noise 1000010000010010001000000 -180 -160 -140 -120 -160 -80 -60 -40 -20 0 dBc/Hz Top in its class with three dynamic ranges. Alive and well, th

8、e non-tiring KENWOOD tone keeps you listening. RECEIVERDiverse interference / noise removal features Receive performance on a whole other level from narrow bandwidth roofing filters that only full down conversion can provide High-speed scanning with independent band scope receiver Local oscillator r

9、ealizes superior C/N IF filter The speed and quality of KENWOODs renowned IF AGC control Other receiver system features RF ATT(OFF/6/12/18dB) Preamp(PRE1/PRE2) Receive only antenna connector(RX IN, RX OUT) Antenna output connector IF filter shape, AF filter Switching is possible between 3 kinds of I

10、F filter shapes: Medium/ Soft/Sharp. Switching is also possible for post-demodulation voice- audio between 3 kinds of AF filter passbands: Medium/Wide/ Narrow. Combinations of these settings can adjust the sharpness of the demodulation signal. Audio peak filter This is a narrow bandwidth peak filter

11、 operated during receive in CW mode. When intelligibility is low due to noise, it has the effect of floating the target signal and increasing intelligibility. The central frequency is linked to the pitch frequency, and can be given a maximum peak gain of +6dB. Notch filter A notch filter that operat

12、es in the IF stage. By eliminating strong interfering signals, it allows weak target signals to stand out. Damping range can be switched between three levels: Narrow/Middle/Wide, enabling operation to match interference conditions. Noise reduction function (NR1/NR2) In addition to conventional NR1/N

13、R2 noise reduction, NR1 comes equipped with noise reduction using spectral-subtraction, which focusses on noise reduction in voice-audio system modes. The optimum noise reduction method is applied for each receive mode. Noise blanker A noise blanker reduces crackling, pulse-type noise. The TS-890S i

14、ncludes two kinds of noise blankers: NB1, which processes analogue signals, and NB2, which carries out digital processing in the IF stage using DSP. Furthermore, selection of NB2 can be made from two kinds of NB with different operating principles. Either NB1 or NB2 can be used depending on noise co

15、nditions, or both can be used simultaneously. Beat cancel function (BC1/BC2) While a notch filter (IF stage) is effective for a single strong beat, beat cancelling (AF stage) shows results on multiple, comparatively weak beats. BC1 is effective on weak beats and continuous beats, while BC2 is effect

16、ive on intermittent beats like CW signals. AGC Quick recovery A function to recover from suppression that happens when pulse noise is included in a receive signal. 110dB* 3rd intermodulation dynamic range (3rd IMDR) measured under punishing 2kHz spacing conditions. 122dB* reciprocal mixing dynamic r

17、ange (RMDR). 150dB* Blocking dynamic range (BDR) All features deliver top-class receive performance. The high-performance DSP displays its prowess during interference-signal control, sound-quality adjustment, and digital operation. (*: 2 kHz spacing measurement standard - Receiver frequency 14.2 MHz

18、, MODE CW, BW 500 Hz, PRE AMP OFF) Measurement conditions (shared) Frx=14.2 MHz, PRE AMP OFF, BW 500 Hz, CW Vertical axis: Dynamic range (shared) Horizontal axis: Interference signal interval (3rd IMDR), interference signal isolation frequency (RMDR, BDR) Values are measured examples. Photograph sho

19、ws optional 270Hz roofing filter installed. 3rd intermodulation dynamic range (3rd IMDR)Reciprocal mixing dynamic range (RMDR) For IF DSP, transmitter ADSP-21363 clock 332MHz For band scope ADSP-21363 clock 332MHz Blocking dynamic range (BDR) 1st local oscillator frequency generation when receiving

20、at 14.1 MHz The TS-890S uses 8.248MHz 1st IF frequency down conversion for its receive signal system in order to continue the adjacent interference signal exclusion legacy refined in the TS-990S. This means you can use narrow bandwidth crystal filters with passband widths of 500Hz or 270Hz (optional

21、 YG-82CN-1) as roofing filters to achieve strong exclusion of unnecessary adjacent signals. The 1st mixer is the H-mode mixer also carried by the TS-990S. Conversion characteristics have been improved with fine-tuning of input/output matching as well the device used. The configuration of the band sc

22、ope receiver has changed from the superheterodyne system used in the TS-990S to 1st IF sampling using an A/D converter (14bit/39MHz), and FPGA digital down conversion. This means a change in scanning method from step FFT to FFT, achieving high- speed updates to the display irrespective of span setti

23、ngs. Interference signal exclusion is not determined by roofing filters and signal system devices alone. The TS-890S has taken the VCO division of the TS-990S and developed it further, combining a VCO device with high C/N in the gigahertz band and a reference oscillation circuit with superior adjace

24、nt C/N to deliver C/N characteristics unattainable in conventional units. Passband frequency range expansion through LOW-CUT/HI-CUT, WIDTH/SHIFT. Interfering signal removal and desired audio-quality adjustment, as well as more convenient operation in digital mode. Operation with LOW-CUT / HI-CUT in

25、SSB/AM/FM mode, WIDTH/ SHIFT in CW mode, and WIDTH function in FSK/PSK mode. Change to WIDTH/SHIFT operation as in CW mode also possible in SSB/SSB- DATA mode. Selection of roofing filter (270Hz*/500Hz/2.7kHz/6kHz/1 5kHz) can be automatic to match IF filter passband width or manual to selectable fre

26、quencies. (*270Hz when option mounted) A variety of functions are realized through 32-bit floating-point DSP technology inherited from the TS-990S, including modulation/demodulation in all modes, IF filter, IF-AGC, and removal of interfering signals. Popular for its non-tiring and great-quality audi

27、o, the IF-AGC has undergone a facelift with a combination of roofing filters and IF filters, and has been designed to enable optimal control under various noise circumstances. Frequency Offset kHz Reciprocal Mixing Dynamic Range 1012100 dB 20 dB 40 dB 60 dB 80 dB 120 dB 100 dB 140 dB Frequency Spaci

28、ng kHz 3rd IM Dynamic Range 1012100 dB 20 dB 40 dB 60 dB 80 dB 100 dB 120 dB 76 Span 10.000 kHzCenter 14.201 280MHz -10 -50 -70 -90 -30 Referrence Level 10.00dBm LowPhNoise FET Pos & Neg 10001 points Temperature deg F Frequency Stability ppm Reference OSC Stability vs Temp. 32 -0.5 -0.4 -0.3 -0.2 -0

29、.1 0 0.1 0.2 0.3 0.4 0.5 506886104122 Evolved power to perform with diverse displays and auto-scroll. A transmitter with stable output, quietness and high speed. Heavy-duty design delivers transmission performance able to withstand long hours of operation. Display / Transmitter The unit carries a hi

30、gh definition 7-inch TFT color display. In addition to a diverse range of display content, the convenient AUTO SCROLL MODE provides strong support for competition or similar operation. Other strengths include clean and stable 100W transmitter output, improved quietness from twin cooling fans, and hi

31、gh-speed operation enabled by an auto antenna tuner. Operational capacity reinforced with displays and various features Filter scope display Highly reliable 100W final-stage amplifier circuit. Heavy-duty design with improved quietness Built-in high-speed automatic antenna tuner enabling high-speed o

32、peration Free settings enabled through linear amp control settings menu TCXO as standard, high frequency stability at 0.1 ppm Expanded touch operation scope A band scope providing ease-of-ease Improved reference level operability ease-of-use The seven-inch TFT color LCD is the same size as that used

33、 in the TS-990S. In addition to basic information including frequency, mode, and S-meter, the band scope and audio scope are also displayed. The TS-890S also displays further improvements in visibility and operability in tough usage scenarios such as competitions. The popular sub-scope from the TS-9

34、90S is carried as a filter scope display. You can confirm receive filter selection status, roofing filter bandwidth, IF filter passband information, receive for ex-audio spectrum, CW pitch frequency, and notch frequency all concentrated in one location. The final-stage amplifier device is a Mitsubis

35、hi-made MOSFET RD100HHF1(Pch 176.5W) operating in push-pull. A MOSFET RD16HHF1 has been used for the drive amp, and a MOSFET RD06HHF1 for the pre-drive amp. Inter-stage matching and fine-tuning delivers superior transmit IMD even for a 13.8V final circuit, enabling operation with a clean and low-dis

36、tortion signal. The unit employs a twin cooling fan system that uses a pair of 80 x 80 mm fans. Using two fans provides sufficient air flow at low rpm, making for superior quietness. The quietness level for the fans when operating has been improved by more than 5dB compared to our conventional model

37、s. Furthermore, the use of an aluminum die-cast chassis combined with a large heat sink makes for a heavy-duty design sufficiently capable of withstanding the tough conditions typical of contests or long hours of hard operation. A variety of linear amp connections have been taken into account, inclu

38、ding self-made ones, and independent settings for various kinds of control at HF/50MHz bands are possible. Possible settings include: linear amp ON/OFF, transmission control (H active, L active), transmission delay ON/OFF, transmission delay time (CW/FSK/PSK) and (SSB/AM/FM), internal relay control,

39、 and external ALC threshold voltage adjustment. The antenna tuner is a preset type also operable during receive and covering amateur bands from 1.8MHz50MHz. High-speed operation and the proven relay method enable rapid QSY through instantaneous band changing. The menu can be used to set an ON/OFF me

40、mory for the antenna tuner for each band. Equipped with a TCXO (temperature compensated crystal oscillator) requiring no warm-up as standard, high stability of 0.1ppm has been obtained in a wide temperature range covering from 32F122F. External standard signal (10MHz) input is also possible. Transmi

41、t digital meter enabling display of two kinds of transmit information even during analog meter display Audio scope (spectrum scope, oscilloscope) able to be displayed simultaneously with reduced band scope Band scope IF filter passband with display Change of gradation for waterfall display Frequency

42、 marker display function (Max. 50) Transmit spectrum display (during CENTER MODE) SWL display mode USB keying/SEND DRV connector output (supports transmission in 137kHz and 475kHz bands) Transmit output limiter (supports ON/OFF switching, mode settings) TX tuning Basic operation of the TS-890S is th

43、rough knobs and switches with a definite clicking feel rather than touchscreen operation, but the below adjustment features and menu settings can now be changed via touch operation. AUTO SCROLL MODE In addition to conventional CENTER MODE and FIXED MODE, the unit comes equipped with an AUTO SCROLL M

44、ODE. While in FIXED MODE, if the receive frequency goes over the scope edge, then auto- scroll will engage for half a screen width. Furthermore, with the EXPAND function turned on, the screen to be displayed next can be drawn in advance*. Also, with the SHIFT function, the receive marker can be set

45、in the desired position on the vertical grid, which is convenient when displaying a non-receive frequency as the center display, such as for pileups during splits. *: Effective in spans under 200kHz. Image becomes slightly coarse when expanded. CENTER MODE When changing the receive frequency in CENT

46、ER MODE, there are many units that display a bright line that flows obliquely over the waterfall, but with the TS-890S, the bright line remains straight and enables tuning operation*. Switching to the follow display is also possible via the menu. *: During straight display, the waterfall bright line

47、 temporarily stops and undergoes parallel displacement. Image becomes slightly coarse when expanded. The TS-890S has improved operability of the reference level focusing on the visibility of the waterfall. Through optimization of each span, readjustment is mostly unnecessary when switching between t

48、hem.* Settings are enabled for each band, and readjustment is also unnecessary for the PRE AMP ON and PRE AMP OFF bands. *: Spectrum scope waveform height changes during span switching. FIXED MODE FIXED MODE allows you to switch between three kinds of display ranges with a single touch of the panel

49、screen. The initial value is preset based on the band plan, but this can be easily adjusted to a desired scope. With the spectrum scope and waterfall screen display, the analogue meter is simultaneously displayed. The popular sub-scope display from the TS-990S has been incorporated as a filter-scope display Auto-scroll operation (span 10 kHz, EXPAND ON) On the current screen (screen 2), if the frequency is changed to go over the top end of screen 2, it will automatically change to screen 3, and if it goes over the bottom end of

展开阅读全文