《FRC-93_Collins_KWM-2_2A_serv_user_TM11-5820-554-12_1976.pdf》由会员分享,可在线阅读,更多相关《FRC-93_Collins_KWM-2_2A_serv_user_TM11-5820-554-12_1976.pdf(152页珍藏版)》请在收音机爱好者资料库上搜索。
1、TM 11-5820-554-12 TECHNICAL MANUAL OPERATORS AND ORGANIZATIONAL MAINTENANCE MANUAL RADIO SET AN/FRC-93(V)1 (NSN 5820-01-054-9106) RADIO SET AN/FRC-93(V)2 (NSN 5820-01-052-1438) RADIO SET AN/FRC-93(V)3 (NSN 5820-01-052-1439) RADIO SET AN/FRC-93(V)4 (NSN 5820-01-053-5535) RADIO SET AN/FRC-93(V)5 (NSN
2、5820-01-052-1440) RADIO SET AN/FRC-93(V)6 (NSN 5820-01-052-1441) RADIO SET AN/FRC-93(V)7 (NSN 5820-01-052-1442) This copy is a reprint which includes current pages from Changes 1 through 6. The title was changed by Change 3. H E A D Q U A R T E R S , D E P A R T M E N T O F T H E A R M Y JUNE 1976 W
3、ARNING Be careful when working on the 275- and 800-volt d.c. terminals of the power supplies, and the 110- or 220-volt a.c. line terminals. Serious injury or death can result from contact with these terminals. DONT TAKE CHANCES! DO NOT BLOCK INTERLOCK SWITCHES Dangerous voltages are present in this
4、equipment. The high voltage is interlocked with the amplifier covers. NEVER put the amplifier into service until all compartment covers are in place. Operator and maintenance personnel should be familiar with the requirements of TB SIG 291 before attempting installation or operation of the equipment
5、 covered in this manual. Failure to follow the requirements of TB SIG 291 can result in injury or death. TM 11-5820-554-12 C6 CHANGEHEADQUARTERS DEPARTMENT OF THE ARMY NO.6WASHINGTON, DC, 13 June 1983 Operators and Organizational Maintenance Manual RADIO SET AN/FRC-93(V)1 (NSN 5820-01-054-9106) RADI
6、O SET AN/FRC-93(V)2 (NSN 5820-01-052-1438) RADIO SET AN/FRC-93(V)3 (NSN 5820-01-052-1439) RADIO SET AN/FRC-93(V)4 (NSN 5820-01-053-5535) RADIO SET AN/FRC-93(V)5 (NSN 5820-01-052-1440) RADIO SET AN/FRC-93(V)6 (NSN 5820-01-052-1441) RADIO SET AN/FRC-93(V)7 (NSN 5820-01-052-1442) TM 11-5820-554-12, 18
7、June 1976, is changed as follows: 1. Remove old pages and insert new pages as indicated below. New or changed material is indicated by a vertical bar in the margin. Where an entire chapter, section, or illustration is added or revised, the vertical bar is placed opposite the identification number an
8、d title. Remove pages Insert pages i and ii . i and ii 1-1 and 1-2. 1-1 and 1-2 3-15 through 3-18. 3-15 through 3-19 4-1 and 4-2. 4-1 and 4-2 5-1, 5-2 and 5-3. 5-1 and 5-2 6-1, 6-2 and 6-3/(6-4 blank) . 6-1, 6-2 and 6-3/(6-4 blank) 7-11 and 7-12. 7-11 and 7-12 8-5 and 8-6. 8-5 and 8-6 9-3 through 9-
9、6 . 9-3 through 9-6 10-9 and 10-10. 10-9 and 10-10 11-7/(11-8 blank). 11-7/(11-8 blank 12-3 and 12-4. 12-3 and 12-4 13-4.1/(13-4.2 blank) A-1 . A-1 3. File this change sheet in front of the publication. By Order of the Secretary of the Army: E. C. MEYER General, United States Army Chief of Staff Off
10、icial: ROBERT M. JOYCE Brigadier General, United States Army The Adjutant General DISTRIBUTION: To be distributed in accordance with DA Form 12-50, Operators maintenance requirements for AN/FRC-93. TM 11-5820-554-12 C5 CHANGEHEADQUARTERS DEPARTMENT OF THE ARMY NO.5WASHINGTON, DC, 5 August 1981 Opera
11、tors and Organizational Maintenance Manual RADIO SET AN/FRC-93(V)1 (NSN 5820-01-054-9106) RADIO SET AN/FRC-93(V)2 (NSN 5820-01-052-1438) RADIO SET AN/FRC-93(V)3 (NSN 5820-01-052-1439) RADIO SET AN/FRC-93(V)4 (NSN 5820-01-053-5535) RADIO SET AN/FRC-93(V)5 (NSN 5820-01-052-1440) RADIO SET AN/FRC-93(V)
12、6 (NSN 5820-01-052-1441) RADIO SET AN/FRC-93(V)7 (NSN 5820-01-052-1442) TM 11-5820-55-12, 18 June 1976, is changed as follows: 1. A vertical bar appears opposite changed material. 2. Remove and insert pages as indicated in the page list below: RemoveInsert 2-1 and 2-2.2-1 and 2-2 3-5 and 3-6.3-5 and
13、 3-6 5-1 and 5-2.5-1 and 5-2 3. File this change sheet in front of the manual for reference purposes. By Order of the Secretary of the Army: E. C. MEYER General, United States Army Chief of Staff Official: ROBERT M. JOYCE Brigadier General, United States Army The Adjutant General DISTRIBUTION: To be
14、 distributed in accordance with DA Form 12-50, Operator maintenance requirements for AN/FRC-93. Information in this manual has been furnished by the Collins Radio Company, the Sola Electric Company, the Superior Electric Company, and the Barker and Williamson Company, and shall not be either release
15、d outside the government or used, duplicated or disclosed in whole or in part for manufacture or procurement, without the written permission of the above companies. *TM 11-5820-554-12 TECHNICAL MANUALHEADQUARTERS DEPARTMENT OF THE ARMY NO.11-5820-554-12WASHINGTON, DC, 18 June 1976 OPERATORS AND ORGA
16、NIZATIONAL MAINTENANCE MANUAL RADIO SET AN/FRC-93(V)1 (NSN 5820-01-054-9106) RADIO SET AN/FRC-93(V)2 (NSN 5820-01-052-1438) RADIO SET AN/FRC-93(V)3 (NSN 5820-01-052-1439) RADIO SET AN/FRC-93(V)4 (NSN 5820-01-053-5535) RADIO SET AN/FRC-93(V)5 (NSN 5820-01-052-1440) RADIO SET AN/FRC-93(V)6 (NSN 5820-0
17、1-052-1441) RADIO SET AN/FRC-93(V)7 (NSN 5820-01-052-1442) This technical manual is an authentication of the manufacturers commercial literature and does not conform with the format and content specified in AR 310-3. This technical manual does, however, contain available information that is essentia
18、l to the operation and maintenance of the equipment. REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS You can help improve this manual. If you find any mistakes or if you know of a way to improve the procedures, please let us know. Mail your letter or DA Form 2028 (Recommended Changes to Publications
19、and Blank Forms) direct to: Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: DRSEL-ME- MP, Fort Monmouth, NJ 07703. In either case, a reply will be furnished direct to you. ParagraphPage CHAPTER1.INTRODUCTION.1-1, 1-131-1, 1-2 2.RADIO SET AN/FRC-93 CONFIGURATIONS.2-1, 2
20、-62-1, 2-3 3.RECEIVER TRANSMITTER RH-718/FRC-93 SECTIONI.Introduction.3-1, 3-53-1, 3-2.1 II.Installation.3-6, 3-83-2, 3-6 III.Operation.3-9, 3-133-6, 3-11 IV.Circuit functioning.3-14, 3-183-15, 3-16 V.Operators maintenance instructions.3-19, 3-243-16, 3-17 VI.Organizational maintenance instructions.
21、3-25, 3-303-18, 3-19 CHAPTER4.CRYSTAL UNIT SET, QUARTZ CK-31/FRC.4-1, 4-44-1, 4-2 5.Q-MULTIPLIER/NOTCH FILTER SECTIONI.Introduction.5-l , 5-25-1 II.Operation.5-3, 5-55-1, 5-2 III.Operators maintenance instructions.5-6, 5-75-2 IV.Deleted.5-8, 5-95-2 This manual supersedes TM 11-5820-554-15, 15 July 1
22、965, and so much of TM 11-5820-529-14, 21 March 1975; TM 11-5820532-15, 28 January 1965; TM 11-5820-530-15, 25 June 1964; and TM 11-6110-242-15, 26 June 1967, as pertains to operator and organizational maintenance. Change 6 i TM 11-5820-554-12 ParagraphPage CHAPTER 6.FILTER, RADIO INTERFERENCE F-113
23、9/GRC-159(V). . .6-1, 6-9 6-1, 6-2 7.POWER SUPPLIES SECTIONI.Power Supply PP-3990/FRC-93. . . . 7-1, 7-6 7 -1, 7-4 II.Power Supply PP-4151/FRC-93. . . . 7-7, 7-12 7-5, 7-6 III.Power Supply PP-4765/GRC-159(V). . . .7-13, 7-18 7-7, 7-8 IV.Power Supply l2-volt d.c .input . . . . 7-19, 7-25 7-8, 7-10 V.
24、Operators maintenance instructions . . . . 7-26, 7-27 7-11 VI.Organizational maintenance instructions . . . .7-28, 7-297-11, 7-12 CHAPTER 8.REGULATOR, VOLTAGE CN-1146/FRC-93 SECTIONI.Introduction . . . . . 8-1, 8-48-1 II.Installation. . . . . 8-5, 8-68-4 III.Principles of operation . . . . .8-7, 8-1
25、58-5, 8-6 IV.Operators maintenance instructions . . . . 8-16, 8-178-6 V.Organizational maintenance instructions . . . .8-18, 8-198-6 CHAPTER 9.REGULATOR, VOLTAGE CN-1214/G SECTIONI.Introduction . . . . . 9-1, 9-49-1 II.Installation. . . . . 9-5, 9-79-2 III.Operation. . . . . .9-8, 9-99-4 IV.Operator
26、s maintenance instructions . . . . 9-10, 9-119-4 V.Organizational maintenance instructions . . . .9-12, 9-159-4, 9-5 VI.Troubleshooting . . . . . 9-16, 9-189-5, 9-6 CHAPTER 10. CONTROL, RADIO SET C-6118/FRC-93 AND CONTROL, RADIO SET C-7515/FRC-93 SECTIONI.Introduction . . . . . 10-1, 10-310-1, 10-3
27、II.Installation. . . . . 10-4, 10-510-3 III.Operation. . . . . .10-6- 10-9 10-6, 10-7 IV.Operators maintenance instructions . . . . 10-10, 10-11 10-9 V.Organizational maintenance instructions . . . .10-12, 10-1310-10 CHAPTER 11. AMPLIFIER RF AM-3979/FRC-93 SECTION I.Introduction . . . . . 11-1, 11-3 11-1 II.Installation. . . . . 11-4, 11-9 11-1, 11-2 III.Operation. .