1、For DX Enthusiasts HF/50MHz/70MHz TRANSCEIVER BDR 150dB 3rd IMDR 110dB RMDR 122dB *: 2 kHz spacing measurement standard - Receiver frequency 14.2 MHz, MODE CW, BW 500 Hz, PRE AMP OFF * * * 2 Performance Exceeding Expectations. 3 The most rewarding results often take place when faced with the harshes

2、t and most challenging conditions. There are enthusiasts who know this all too well because of their love of DX. KENWOOD has the answer. Achieve results through certainty and not circumstance. Delivered through impeccable receiver and audio performance. This is our offering to you. 396(W)141.3(H)340

3、(D)mm (not including protrusions) 4 DSP FPGA ADC RF BPF Band scope receiver through H-mode Mixer Post Amp Roofing Filters Receive signal system Down conversion receiver BPF ATT PRE AMP 270Hz (Option) 500Hz 2.7kHz 6kHz 15kHz ATT Frequency Spacing kHz 3rd IM Dynamic Range 1012100 dB 20 dB 40 dB 60 dB

4、80 dB 100 dB 120 dB Frequency Offset kHz Reciprocal Mixing Dynamic Range 1012100 dB 20 dB 40 dB 60 dB 80 dB 120 dB 100 dB 140 dB Frequency Offset kHz Blocking Dynamic Range 1012100 dB 20 dB 40 dB 60 dB 80 dB 120 dB 140 dB 100 dB 160 dB Top in its class with three dynamic ranges. Alive and well, the

5、non-tiring KENWOOD tone keeps you listening. RECEIVER Receive performance on a whole other level from narrow bandwidth roofing filters that only full down conversion can provide High-speed scanning with independent band scope receiver 110dB* 3rd intermodulation dynamic range (3rd IMDR) measured unde

6、r punishing 2kHz spacing conditions. 122dB* reciprocal mixing dynamic range (RMDR). 150dB* Blocking dynamic range (BDR) All features deliver top-class receive performance. The high-performance DSP displays its prowess during interference-signal control, sound-quality adjustment, and digital operatio

7、n. Measurement conditions (shared) Frx=14.2 MHz, PRE AMP OFF, BW 500 Hz, CW Vertical axis: Dynamic range (shared) Horizontal axis: Interference signal interval (3rd IMDR), interference signal isolation frequency (RMDR, BDR) Values are measured examples. Photograph shows optional 270Hz roofing filter

8、 installed. 3rd intermodulation dynamic range (3rd IMDR)Reciprocal mixing dynamic range (RMDR)Blocking dynamic range (BDR) The TS-890S uses 8.248MHz 1st IF frequency down conversion for its receive signal system in order to continue the adjacent interference signal exclusion legacy refined in the TS

9、-990S. This means you can use narrow bandwidth crystal filters with passband widths of 500Hz or 270Hz (optional YG-82CN-1) as roofing filters to achieve strong exclusion of unnecessary adjacent signals. The 1st mixer is the H-mode mixer also carried by the TS-990S. Conversion characteristics have be

10、en improved with fine-tuning of input/output matching as well the device used. The configuration of the band scope receiver has changed from the superheterodyne system used in the TS-990S to 1st IF sampling using an A/D converter (14bit/39MHz), and FPGA digital down conversion. This means a change i

11、n scanning method from step FFT to FFT, achieving high- speed updates to the display irrespective of span settings. (*: 2 kHz spacing measurement standard - Receiver frequency 14.2 MHz, MODE CW, BW 500 Hz, PRE AMP OFF) 5 1st Local OSC Phase Noise (14.1MHz) Values are measured examples. HMC829 PLL PL

12、L VCO Div.1 Div.2 19.2 MHz 100 MHz 3218.112 MHz 22.348 MHz 1st local oscillator frequency 0.1 ppm TCXO Frequency Offset Hz 1st Local OSC Phase Noise 1000010000010010001000000 -180 -160 -140 -120 -160 -80 -60 -40 -20 0 dBc/Hz Diverse interference / noise removal features Local oscillator realises sup

13、erior C/N IF filter The speed and quality of KENWOODs renowned IF AGC control Other receiver system features RF ATT(OFF/6/12/18dB) Preamp(PRE1/PRE2) Receive only antenna connector(RX IN, RX OUT) Antenna output connector IF filter shape, AF filter Switching is possible between 3 kinds of IF filter sh

14、apes: Medium/ Soft/Sharp. Switching is also possible for post-demodulation voice- audio between 3 kinds of AF filter passbands: Medium/Wide/ Narrow. Combinations of these settings can adjust the sharpness of the demodulation signal. Audio peak filter This is a narrow bandwidth peak filter operated d

15、uring receive in CW mode. When intelligibility is low due to noise, it has the effect of floating the target signal and increasing intelligibility. The central frequency is linked to the pitch frequency, and can be given a maximum peak gain of +6dB. Notch filter A notch filter that operates in the I

16、F stage. By eliminating strong interfering signals, it allows weak target signals to stand out. Damping range can be switched between three levels: Narrow/Middle/Wide, enabling operation to match interference conditions. Noise reduction function (NR1/NR2) In addition to conventional NR1/NR2 noise re

17、duction, NR1 comes equipped with noise reduction using spectral-subtraction, which focusses on noise reduction in voice-audio system modes. The optimum noise reduction method is applied for each receive mode. Noise blanker A noise blanker reduces crackling, pulse-type noise. The TS-890S includes two

18、 kinds of noise blankers: NB1, which processes analogue signals, and NB2, which carries out digital processing in the IF stage using DSP. Furthermore, selection of NB2 can be made from two kinds of NB with different operating principles. Either NB1 or NB2 can be used depending on noise conditions, o

19、r both can be used simultaneously. Beat cancel function (BC1/BC2) While a notch filter (IF stage) is effective for a single strong beat, beat cancelling (AF stage) shows results on multiple, comparatively weak beats. BC1 is effective on weak beats and continuous beats, while BC2 is effective on inte

20、rmittent beats like CW signals. AGC Quick recovery A function to recover from suppression that happens when pulse noise is included in a receive signal. For IF DSP, transmitter ADSP-21363 clock 332MHz For band scope ADSP-21363 clock 332MHz 1st local oscillator frequency generation when receiving at

21、14.1 MHz Interference signal exclusion is not determined by roofing filters and signal system devices alone. The TS-890S has taken the VCO division of the TS-990S and developed it further, combining a VCO device with high C/N in the gigahertz band and a reference oscillation circuit with superior ad

22、jacent C/N to deliver C/N characteristics unattainable in conventional units. Passband frequency range expansion through LOW-CUT/HI-CUT, WIDTH/SHIFT. Interfering signal removal and desired audio-quality adjustment, as well as more convenient operation in digital mode. Operation with LOW-CUT / HI-CUT

23、 in SSB/AM/FM mode, WIDTH/ SHIFT in CW mode, and WIDTH function in FSK/PSK mode. Change to WIDTH/SHIFT operation as in CW mode also possible in SSB/SSB- DATA mode. Selection of roofing filter (270Hz*/500Hz/2.7kHz/6kHz/1 5kHz) can be automatic to match IF filter passband width or manual to selectable

24、 frequencies. (*270Hz when option mounted) A variety of functions are realised through 32-bit floating-point DSP technology inherited from the TS-990S, including modulation/demodulation in all modes, IF filter, IF-AGC, and removal of interfering signals. Popular for its non-tiring and great-quality

25、audio, the IF-AGC has undergone a facelift with a combination of roofing filters and IF filters, and has been designed to enable optimal control under various noise circumstances. 6 Evolved power to perform with diverse displays and auto-scroll. A transmitter with stable output, quietness and high s

26、peed. Display / Transmitter The unit carries a high definition 7-inch TFT color display. In addition to a diverse range of display content, the convenient AUTO SCROLL MODE provides strong support for competition or similar operation. Other strengths include clean and stable 100W* transmitter output,

27、 improved quietness from twin cooling fans, and high-speed operation enabled by an auto antenna tuner. Operational capacity reinforced with displays and various features A band scope providing ease-of-ease Improved reference level operability ease-of-use The seven-inch TFT color LCD is the same size

28、 as that used in the TS-990S. In addition to basic information including frequency, mode, and S-meter, the band scope and audio scope are also displayed. The TS-890S also displays further improvements in visibility and operability in tough usage scenarios such as competitions. AUTO SCROLL MODE In ad

29、dition to conventional CENTER MODE and FIXED MODE, the unit comes equipped with an AUTO SCROLL MODE. While in FIXED MODE, if the receive frequency goes over the scope edge, then auto- scroll will engage for half a screen width. Furthermore, with the EXPAND function turned on, the screen to be displa

30、yed next can be drawn in advance*. Also, with the SHIFT function, the receive marker can be set in the desired position on the vertical grid, which is convenient when displaying a non-receive frequency as the center display, such as for pileups during splits. *: Effective in spans under 200kHz. Imag

31、e becomes slightly coarse when expanded. CENTER MODE When changing the receive frequency in CENTER MODE, there are many units that display a bright line that flows obliquely over the waterfall, but with the TS-890S, the bright line remains straight and enables tuning operation*. Switching to the fol

32、low display is also possible via the menu. *: During straight display, the waterfall bright line temporarily stops and undergoes parallel displacement. Image becomes slightly coarse when expanded. The TS-890S has improved operability of the reference level focusing on the visibility of the waterfall

33、. Through optimisation of each span, readjustment is mostly unnecessary when switching between them.* Settings are enabled for each band, and readjustment is also unnecessary for the PRE AMP ON and PRE AMP OFF bands. *: Spectrum scope waveform height changes during span switching. FIXED MODE FIXED M

34、ODE allows you to switch between three kinds of display ranges with a single touch of the panel screen. The initial value is preset based on the band plan, but this can be easily adjusted to a desired scope. With the spectrum scope and waterfall screen display, the analogue meter is simultaneously d

35、isplayed. The popular sub-scope display from the TS-990S has been incorporated as a filter-scope display Auto-scroll operation (span 10 kHz, EXPAND ON) On the current screen (screen 2), if the frequency is changed to go over the top end of screen 2, it will automatically change to screen 3, and if i

36、t goes over the bottom end of screen 2, it will automatically change to screen 1. Waterfall screen creation normally commences after switching screens, but with the EXPAND function turned to ON, the display switches to the finished screen. Screen 1Screen 2Screen 3 Follow displayStraight display *70

37、MHz band is 50 W 7 Span 10.000 kHzCenter 14.201 280MHz -10 -50 -70 -90 -30 Referrence Level 10.00dBm LowPhNoise FET Pos & Neg 10001 points Temperature deg C Frequency Stability ppm Reference OSC Stability vs Temp. 0 -0.5 -0.4 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5 1020304050 Heavy-duty design delivers

38、 transmission performance able to withstand long hours of operation. Filter scope display Highly reliable 100W final-stage amplifier circuit. (*70 MHz band is 50 W) Heavy-duty design with improved quietness Built-in high-speed automatic antenna tuner enabling high-speed operation Free settings enabl

39、ed through linear amp control settings menu TCXO as standard, high frequency stability at 0.1 ppm Expanded touch operation scope The popular sub-scope from the TS-990S is carried as a filter scope display. You can confirm receive filter selection status, roofing filter bandwidth, IF filter passband

40、information, receive for ex-audio spectrum, CW pitch frequency, and notch frequency all concentrated in one location. The final-stage amplifier device is a Mitsubishi-made MOSFET RD100HHF1(Pch 176.5W) operating in push-pull. A MOSFET RD16HHF1 has been used for the drive amp, and a MOSFET RD06HHF1 fo

41、r the pre-drive amp. Inter-stage matching and fine-tuning delivers superior transmit IMD even for a 13.8V final circuit, enabling operation with a clean and low-distortion signal. The unit employs a twin cooling fan system that uses a pair of 80 x 80 mm fans. Using two fans provides sufficient air f

42、low at low rpm, making for superior quietness. The quietness level for the fans when operating has been improved by more than 5dB compared to our conventional models. Furthermore, the use of an aluminum die-cast chassis combined with a large heat sink makes for a heavy-duty design sufficiently capab

43、le of withstanding the tough conditions typical of contests or long hours of hard operation. A variety of linear amp connections have been taken into account, including self-made ones, and independent settings for various kinds of control at HF/50MHz, 70MHz bands are possible. Possible settings incl

44、ude: linear amp ON/OFF, transmission control (H active, L active), transmission delay ON/OFF, transmission delay time (CW/FSK/PSK) and (SSB/AM/FM), internal relay control, and external ALC threshold voltage adjustment. The antenna tuner is a preset type also operable during receive and covering amat

45、eur bands from 1.8MHz70MHz. High-speed operation and the proven relay method enable rapid QSY through instantaneous band changing. The menu can be used to set an ON/ OFF memory for the antenna tuner for each band. Equipped with a TCXO (temperature compensated crystal oscillator) requiring no warm-up

46、 as standard, high stability of 0.1ppm has been obtained in a wide temperature range covering from 0C+50C. External standard signal (10MHz) input is also possible. Transmit digital meter enabling display of two kinds of transmit information even during analogue meter display Audio scope (spectrum sc

47、ope, oscilloscope) able to be displayed simultaneously with reduced band scope Band scope IF filter passband with display Change of gradation for waterfall display Frequency marker display function (Max. 50) Transmit spectrum display (during CENTER MODE) SWL display mode. USB keying/SEND DRV connect

48、or output (supports transmission in 137kHz and 475kHz bands) Transmit output limiter (supports ON/OFF switching, mode settings) TX tuning Basic operation of the TS-890S is through knobs and switches with a definite clicking feel rather than touchscreen operation, but the below adjustment features an

49、d menu settings can now be changed via touch operation. CW mode display example SSB mode display example The position of the heatsink in the center of the rear panel TCXO temperature drift characteristics Values are measured examples. 14MHz transmit IMD example (100W output) Values are measured examples. RX/TX equaliser level adjustment, meter type (analogue white / analogue black / bar meter) switching, FFT scope/X-Y scope switching on RTTY decode screen, FFT scope/ vector scope switching on PSK decode screen, voice-audio file

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 火腿一族 > Kenwood

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号