《JRC_JSS-296_user.pdf》由会员分享,可在线阅读,更多相关《JRC_JSS-296_user.pdf(154页珍藏版)》请在收音机爱好者资料库上搜索。
1、JSS-296JSS-296 MF/HF RADIO EQUIPMENT INSTRUCTION MANUAL Nittochi Nishi-Shinjuku bldg. 10-1, Nishi-Shinjuku 6-chome, Shinjuku-ku, Tokyo 160-8328 JAPAN Phone : +81-3-3348-0151 Fax : +81-3-3348-3648 1-1, Shimorenjaku 5-chome, Mitaka-shi, Tokyo 181-8510 JAPAN Phone: +81-422-45-9111 Fax: +81-422-45-9110
2、HEAD OFFICE the alarm for distress calls cannot be turned OFF. ?Procedure 1. From the SETUP screen, press and then press . The OTHERS ALARM SETTING screen is displayed. 2. Select ON or OFF. ? The default setting is ON. Use and to change the setting. ? Press to confirm the setting. 3.On completion of
3、 entering the data, press , and then press (SAVE). Operation returns to the SETUP screen. Press , and then press (QUIT) to cancel this menu. 6ENT OTHERS ALARM SETUP Alarm:ON ENT 9FUNC FUNC4Note 3-72 AUTOMATIC ACKNOWLEDGEMENT SETUP The DSC terminal can be set to automatically send back an acknowledge
4、ment call (with ACK BQ for EOS) when receiving a DSC call with ACK RQ for EOS. However, when the CATEGORY is DISTRESS, URGENCY, or SAFETY, no acknowledgement is made automatically, even though ACK RQ is specified for EOS. Acknowledgement is made manually for all distress calls. ?Procedure 1. From th
5、e SETUP screen, press and then press . The AUTOMATIC ACKNOWLEDGEMENT SETUP screen is displayed. 2. Select ON or OFF. ? The default setting is ON. Use and to change the setting. ? Press to confirm the setting. 3.On completion of entering the data, press , and then press (SAVE). Operation returns to t
6、he SETUP screen. Press , and then press (QUIT) to cancel this menu. 7ENT AUTOMATIC ACKNOWLEDGEMENT SETUP Acknowledgement:ON ENT 9FUNC FUNC4Note 3-73 WATCHKEEPING RECEIVER SETUP CH1.2187.5kHz:ON(const) CH2.4207.5kHz:ON CH3.6312.0kHz:OFF CH4.8414.5kHz:ON(const) CH5. 12577.0kHz:OFF CH6. 16804.5kHz:ON U
7、se and to scroll the screen. WATCHKEEPING RECEIVER SETUP This procedure sets the Watch-keeping receivers scanning frequency. The 2187.5kHz and 8414.5kHz frequencies are preselected; here, frequencies are selected for the other four channels. The DISTRESS FREQUENCY lamps (on the front panel) are turn
8、ed ON/OFF for each set channel. The lamps for 2187.5kHz and 8414.5kHz are always ON. ?Procedure 1. From the SETUP screen, press and then press . The WATCHKEEPING RECEIVER SETUP screen is displayed. 2. Select ON or OFF. ? The default setting is ON. Use and to change the setting. ? Press to confirm th
9、e setting. The corresponding lamp for that frequency is turned ON or OFF according to the setting. 3.On completion of entering the data, press , and then press (SAVE). Operation returns to the SETUP screen. Press , and then press (QUIT) to cancel this menu. 9ENT ENT 9 FUNC FUNC4Note 3-74 CLICK SOUND
10、 SETTING The click sound set to ON/OFF during turning on the NCT-196N. ?Procedure 1. Press and . When turning OFF the power switch, click sound is reset to ON. MODEM RESET This operation is the same as the Power ON reset. ?Procedure 1. Press and . The following display appears. 2. The initialization
11、 is completed in several seconds. The following initial display appears. 0FUNC FUNCSTOP JRC NCT-196N DSC/NBDP MODEM Software Version MAIN:X.XX SUB:X.XX Navigation :NMEA0183 Transceiver:JSB-196/196GM Note DSC watching 06.Sep.2001(Thu) 01:26 1234N12345E SPEED:12.4KT at 01:26 Self-ID = XXXXXXXXX UTC 3-
12、75 3.6 NBDP operations The NCT-196N DSC/NBDP MODEM has several communication methods in telex (TLX) mode as NBDP function. Previously created message files or keyboard-typed messages can be sent during the communication. All of operations are performed using NDZ-127J DTE, and the communication metho
13、ds and other settings for TLX mode are described in this chapter. (Regarding the MODE selection for TLX, see “4.3.2 MODE change to TLX”.) 3.6.1 NBDP Settings Before operations in TLX mode, setup the NBDP functions using SYSTEM? NBDP setup menu of the NDZ-127J DTE. The following screen appeared by se
14、lecting the menu item. Each parameter is set as follows: ARQ/FEC 4- or 5-digit Self-ID: Fixed GFEC 4- or 5-digit Self-ID: Fixed ARQ/FEC 9-digit Self-ID: Fixed GFEC 9-digit Self-ID: Fixed Answerback: Fixed Max. FEC error rate: Press Enter key and setup in the input window. Max. automatic call series:
15、 Press Enter key and set a value of 1-99 in the input display. Collective FEC receiving: Press Enter key to change ON/OFF. Internal alarm: Press Enter key to change ON/OFF. Time duration for AUTO: Press Enter key and setup the time in the input window. Restart: Press Enter key to change ON/OFF. Fini
16、te start/restart: Press Enter key to change ON/OFF. Transmitter pre-key time: Press Enter key and setup the time in the input window. After these settings, select the Save button or Cancel button to finish this setup. The above parameters showed “Fixed” have already been set and are impossible to be
17、 changed. The meanings of the above items are as follows; Max. FEC error rate :The limit value of error rate to continue to receive CFEC/ SFEC. When the error rate is beyond the value due to the noisy radio circuit condition or any other signals, the MODEM stops the receiving and return to stand-by.
18、 Max. automatic call series :The limit value of retrying the CALL mode sequence. The interval to retry is 15 minutes respectively. Note ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 3-76 Collective FEC receiving :ON -CFEC receiving is permitted. OFF -CFEC receiving is prohibited. Internal alarm :ON -Internal alar
19、m works. OFF -Internal alarm does not work. Time duration for AUTO :Time duration setting for AUTO mode Restart :ON -The MODEM tries to reconnect when the circuit established once is lost for 32 times of successive REPEAT condition OFF -The MODEM returns to stand-by when the circuit established once
20、 is lost for 32 times of successive REPEAT condition Finite start/restart :ON -The MODEM returns to stand-by when the times of calling a partner station are reached to 128 in ARQ mode. OFF -The MODEM continues to call a partner station even if the times of calling are reached to 128 in ARQ mode. Tra
21、nsmitter pre-key time :Adjustment of timing from KEY ON to signal output for the transmitter electrical specification. It is also available to arrange the Send/Receive timing between long-ranged partner station. 3-77 3.6.2 ARQ Communication ARQ mode is two way telex communication with a partner as a
22、 destination station. When beginning to call a partner using ARQ mode, it is necessary to select a partner (ID) and a communication channel. The operation from the beginning until the end of the communication with a partner are described in this section. ?Procedure 1. Select Connect ? ARQ and press
23、Enter key. 2. Select a partner station from the following window and press Enter key. If Manual button is selected using Tab and Enter keys, the partner ID and Frequency/Channel can be set manually. Before transmitting, confirm that the selected channel / frequency is not occupied by other station(s
24、). Do not operate JSB-196 during ARQ communication. ATTENTION Note 3-78 3. Select Tx/Rx frequency from the following window and press Enter key. 4. After the following window opened, check the channel condition and if not occupied, press Enter key. If the channel is occupied by the other stations, s
25、elect NO and return to step 3 to select another channel. 5. The channel is tuned automatically and the NCT-196N begins to call a partner station. The following screen is displayed while calling. Note 3-79 6. When the connection is established, the following screen appears and the DTE is ready to com
26、municate with a partner station. Send message to the partner station using the keyboard. In case of sending the previously created message file, press F8 (F.Send) and select the file to be sent on the following window. 7. To terminate communication, press F10 . The following display appears and the
27、DTE returns to the stand-by. 3-80 ?The meanings of cells showed in STATUS INFO are as follows; (no use) (*1) (*2) (*3) (*4) (*5) (*6) *1 :Communication mode (stand-by, ARQ, CFEC, SFEC) *2 :The position related with a partner station (Calling - master, Called - slave) *3 :The right to send message (S
28、end - enable to send message, Receive - wait) *4 :MODEM condition on connecting with a partner station (Phasing, Rephasing) *5 :Communication data error condition (Repeat - resending data) *6 :Communication condition (TRAF - sending data completed, RQ - repeating) ?The function key F 2 F10 assignmen
29、ts are as follows; F 2 :WRU -Request to send Answerback code of a partner station F 3 :Here is -Sending Answerback code of own station F 4 :TMS -Sending the time of own position F 5 :Over -Exchanging the right to send message F 6 :POLL -Getting the right to send messages without terminating the comm
30、unication even if a partner station try to terminate F 8 :F.Send -Sending the previously created file F10 :Stop -Terminating communication Note 3-81 3.? 3.6.3 FEC Communication There are two types of FEC modes such as SFEC (Selective FEC) in which a destination is specified and CFEC (Collective FEC)
31、 in which the destination is not specified. The ways to communicate using FEC modes are described below. Note that the FEC receiving is automatic so the operation method is left out in this section, and furthermore CFEC receiving can be disabled using NBDP setup. (See “6.1 NBDP settings.) 3.6.3.1 SF
32、EC Communication ?Procedure 1. Select Connect ? FEC ? SFEC and press Enter key. 2. Select a partner station from the following window and press Enter key. If Manual button is selected using Tab and Enter keys, the partner ID and Frequency/Channel can be set manually. Before transmitting, confirm tha
33、t the selected channel / frequency is not occupied by other station(s). ATTENTION Note 3-82 3. Select Tx/Rx frequency from the following window and press Enter key. 4. After the following window opened, check the channel condition and if not occupied, press Enter key. If the channel is occupied by t
34、he other stations, select NO and return to step 3 to select another channel. 5. The channel is tuned automatically and the NCT-196N begins to call a partner station. ? The communication is started after displayed “Message start” on screen. ? To terminate communication, press F10 . Note 3-83 3.6.3.2
35、CFEC Communication ?Procedure 1. Select Connect ? FEC ? CFEC and press Enter key. 2. Input Tx/Rx frequency on the following window. Then select Set using Tab key and press Enter key. If input using ITU channel, select ITU CHANNEL button using Tab and Enter keys. Before transmitting, confirm that the
36、 selected channel / frequency is not occupied by other station(s). ATTENTION Note 3-84 3. After the following window opened, check the channel condition and if not occupied, press Enter key. If the frequency is occupied by the other stations, select NO and return to step 2 to select another frequenc
37、y. 4. The frequency is tuned automatically and the NCT-196N begins to call all ships. ? The communication is started after displayed “Message start” on screen. ? To terminate communication, press F10 . Note 3-85 3.? 3.6.4 Scanning for TLX mode The NBDP function of the NCT-196N can be set to scan a s
38、pecified group channels so that the NCT-196N respond to the station automatically if there is a station calling own station by ARQ or transmitting by FEC. The way to start/stop the scanning is described in this section. 3.6.4.1 Scanning start ?Procedure 1. Select Tune? Scanning start and press Enter
39、 key. 2. Select the desired station on the following window and press Enter key. Scanning is started in order by the channel number. To adjust the intervals for scanning, Select System? Scan speed and set scan speed. ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
40、 Note 3-86 3.6.4.2 Scanning stop ?Procedure 1. Select Tune? Scanning stop and press Enter key. 2. Scanning is stopped and the NCT-196N returns to stand-by condition. The Tx/Rx frequency is set to the frequency scanned last. ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 3-87 3.7 PA operations The NAH-692 Power Amplifier connected to JSB-196GM ca