Vertex_VX-6000L_serv.pdf

上传人:cc518 文档编号:198154 上传时间:2025-03-08 格式:PDF 页数:95 大小:7.76MB
下载 相关 举报
Vertex_VX-6000L_serv.pdf_第1页
第1页 / 共95页
Vertex_VX-6000L_serv.pdf_第2页
第2页 / 共95页
Vertex_VX-6000L_serv.pdf_第3页
第3页 / 共95页
亲,该文档总共95页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Vertex_VX-6000L_serv.pdf》由会员分享,可在线阅读,更多相关《Vertex_VX-6000L_serv.pdf(95页珍藏版)》请在收音机爱好者资料库上搜索。

1、1 Introduction This manual provides technical information necessary for servicing the VX-6000L FM Transceiver. Servicing this equipment requires expertise in handling surface-mount chip components. Attempts by non-qualified persons to service this equipment may result in permanent damage not covered

2、 by the warranty, and may be illegal in some countries. Two PCB layout diagrams are provided for each double-sided circuit board in the Transceiver. Each side of is referred to by the type of the majority of components installed on that side (“leaded” or “chip-only”). In most cases one side has only

3、 chip components, and the other has either a mixture of both chip and leaded components (trimmers, coils, electrolytic capacitors, ICs, etc.), or leaded components only. While we believe the technical information in this manual to be correct, VERTEX STANDARD assumes no liability for damage that may

4、occur as a result of typographical or other errors that may be present. Your cooperation in pointing out any inconsistencies in the technical information would be appreciated. 2009 VERTEX STANDARD CO., LTD. EC024L90B Service Manual VX-6000L VHF Low-Band FM Transceiver Operating Manual Reprint.1-1 Cl

5、oning .2-1 Specifications.2-2 Exploded View background noise will now be heard, and you may use this to set the VOLUME knob for the desired audio level. Press and hold the MON button more than 1/2 sec- onds to quiet the noise and resume normal (quiet) monitoring. Transmitting To transmit, wait until

6、 the “BUSY” indicator is off (the channel is not in use), and press the PTT (Push-To-Talk) switch on the side of the micro- phone (the “TX” indicator will appear or the “TX” indicator will glow red). While holding in the PTT switch, speak across the face of the microphone in a clear, normal voice le

7、vel, and then release the PTT switch to receive. Selecting Groups and Channels ? Press the UP (?) or DOWN (?) button (repeat- edly, if necessary) to select a different group of channels. ? Turn the CHANNEL selector knob to select a different channel within the current group. Automatic Time-Out Timer

8、 If the selected channel has been programmed for automatic time-out, you must limit the length of each transmission. While transmitting, a beep will sound five seconds before time-out. Another beep will sound just before the deadline; the “TX” in- dicator will disappear and transmission will cease s

9、oon thereafter. To resume transmitting, you must release the PTT and wait for the “penalty timer” to expire (if you press the PTT before this timer expires, the timer restarts, and you will have to wait another “penalty” period.) 1-4 POWER Operating Manual Reprint ADVANCED OPERATION Programmable Fun

10、ction Button (PF button) The VX-6000 includes the seven Programmable Function Buttons (PF button). The PF button functions can be customized, via programming by your VERTEX STANDARD dealer, to meet your communications/network requirements. Some features may require the purchase and in- stallation of

11、 optional internal accessories. The possible PF button programming features are il- lustrated at the below, and their functions are ex- plained on next page. For further details, contact your VERTEX STAN- DARD dealer. For future reference, check the box next to each function that has been assigned t

12、o the PF button on your particular radio, and keep it handy. 1.5 sec 1.5 sec 1.5 sec 1.5 sec 1.5 sec 1.5 sec 1.5 sec Functions Programmable Function Button (PF button) None SCAN (SCN) Dual Watch Call/Reset Talk-Around (TA) Noise Blanker* (NB) Alpha Numeric (A/N) DIMMER (DIM) Emergency (EMG) Horn Ale

13、rt (HA) Home Channel (HOM) Intercom (IC) Low Power (LOW) GRP UP GRP DWN CH UP CH DWN AUX A AUX B AUX C Public Address (PA) Monitor (MON) RCL Selectable Tone (ST) SP* Squelch Level (SQL) Compander Encryption* (OPT) * for VX-6000L * requires RMK-4000 * requires Encryption Unit 1-5 Operating Manual Rep

14、rint Channel Scan The Scanning feature is used to monitor multiple signals programmed into the transceiver. While scanning, the transceiver will check each channel for the presence of a signal, and will stop on a channel if a signal is present. To activate scanning: ? Press the assigned PF button of

15、 the “Scan” mo- mentarily to activate scanning. ? The scanner will search the channels, looking for active ones; it will pause each time it finds a channel on which someone is speaking. To stop scanning ? Press the assigned PF button of the “Scan”. ? Operation will revert to the channel to which the

16、 CHANNEL selector knob is set. Note:Your dealer may have programmed your radio to stay on one of the following chan- nels if you press the PTT switch during scan- ning pause: ? Current channel (“Talk Back”) ? “Last Busy” channel ? “Priority” channel ? “Home” channel ?Scan Start” channel Dual Watch T

17、he Dual Watch feature is similar to the Scan fea- ture, except that only two channels are monitored: ? The current operating channel; and ? The “Priority” channel. To activate Dual Watch: ? Press the assigned PF button of the “Dual Watch”. ? The scanner will search the two channels; it will pause ea

18、ch time it finds a channel on which someone is speaking. ? Press the assigned PF button of the “Dual Watch”. ? Operation will revert to the channel to which the CHANNEL selector knob is set. ADVANCED OPERATION ARTS (Auto Range Transpond System) This system is designed to inform you when you and anot

19、her ARTS-equipped station are within communication range. During ARTS operation, your radio automatically transmits for about 1 second every 25 (or 55) sec- onds (the interval is programmed by Dealer) in an attempt to Shake hands with the other station. If you move out of range for more than one min

20、- utes, your radio senses that no signal has been received, a ringing beeper will sound. If you sub- sequently move back into range, as soon as the other station transmits, your beeper will sound. The PF Button Function The PF (Programmable Function) button can be programmed by the dealer to provide

21、 two of the other functions described below. To activate the primary Accessory function, press the PF button momentarily. To access the second- ary Accessory function (which may include the Alarm), press and hold the PF button for 1.5 sec- onds or longer. Call/Reset When this feature is programmed a

22、nd a selective call has been received, momentarily press the as- signed PF button of the “Call/Reset” to reset the flashing indicator and mute the receiver, other- wise press the assigned PF button of the “Call/ Reset” to sent your radios identification code (ANI) to the dispatcher. Talk-Around The

23、feature causes the assigned PF button of the “Talk-Around” to select simplex operation on semi-duplex channels: the transmit frequency becomes the same as the receive frequency (re- gardless of any programmed offset for the chan- nel). Note:This feature has no effect on simplex channels. After press

24、ing the button, “-TAKARD-” is displayed on the LCD. Noise Blanker (for VX-6000L) Because local noise can be particularly trouble- some in the VHF Low-Band frequency spectrum, the Low-Band version of the VX-6000 includes a Noise Blanker feature, which may be toggled on and off by pressing the assigne

25、d PFof the “Noise Blanker” for the appropriate length of time. 1-6 Operating Manual Reprint Alpha Numeric Press the assigned PF button of the “Alpha Nu- meric” to switch the display between the Group/ Channel number, and the Group/Channel name (alphanumeric). A tone will sound each time you switch b

26、etween numerical and alphanumerical display. DIM Press the assigned PF button of the “DIM” to ad- just the brightness of the display and key backright. EMG (Emergency) Press the assigned PF button of the “EMG” to initiate an emergency call (requires ANI board). When an emergency call is made, not to

27、ne is emit- ted and the display does not change. To end the emergency call, turn the transceiver power OFF. HA (Horn Alert) Press the assigned PF button of the “HA” to turn the Horn Alert function ON or OFF. If you receive a call from the base station with 2Tone or DTMF signaling, horn alert will ac

28、tivate. When you turn Horn Alert ON, a tone will sound and “ ” appears on the display. Home (Home Channel) Press the assigned PF button of the “Home” to select the pre-programmed Home Channel. Press it again to return to the previous channel. If used while scanning, pressing this key a second time w

29、ill change to the revert channel. IC (Intercom) This feature requires dual head configuration. Press the assigned PF button of the “IC” to turn the intercom feature ON or OFF. While ON, you can press the PTT switch to communicate to an- other control head operator without transmitting over the air.

30、When you press this key, a tone sounds and “” appears on the display. The in- tercom can be used even while scanning and re- ceiving a call. Low Power Press the assigned PF button of the “Low Power” to set the radios transmitter to the “Low Power” mode. Press this key again to return to “High Power”

31、 operation when in difficult terrain. ADVANCED OPERATION GRP UP/DWN Press the assigned PF button of the “GRP UP” or “GRP DWN” to select a different group of chan- nels. CH UP/DWN Press the assigned PF button of the “CH UP” or “CH DWN” to select a different channel within the current group. AUX A/B/C

32、 Press the assigned PF button of the “AUX A”, “AUX B”, or “AUX C” to turn the output port (re- spectively). PA (Public Address) Press the assigned PF button of the “PA” to use the transceiver as a PA amplifier. When you en- able this function, a tone sounds and “” ap- pears on the display. The publi

33、c address can be used even while scanning and receiving a call. MONI (Monitor) Press the assigned PF button of the “MONI” mo- mentarily to cancel CTCSS and DCS signaling squelch; the “MON” icon appears on the display. Press and hold this key for 1/2 seconds to hear background noise (unmute the audio

34、); the MON icon blinks on the display. RCL (Channel Recall) During scan, you can press the assigned PF but- ton of the “RCL” to select the last called channel. ST (Selectable Tone) Press the assigned PF button of the “Selectable Tone”, then rotate the CHANNEL selector knob to select a 2-Tone. SP Pre

35、ss the assigned PFbutton of the “SP” to switch “Front panel”, “Front panel the signal is ad- justed for optimum deviation level and delivered to the next stage. Voice inputs from the microphone and CTCSS are frequency-modulated to the VCO of the synthesiz- er, while DCS audio is modulated by the ref

36、erence frequency oscillator of the synthesizer. Synthesizer output, after passing through diode switch D1022 (1SS321), to obtain the required RF drive prior to delivery to the PA Unit. There the RF signal is amplified by parallel junction transistors Q6006/Q6007 (SD1405X2) and passes through an- ten

37、na switching relay RL6001 and a low-pass filter circuit, and ultimately to the antenna connector. RF output power from the final amplifier is sam- pled by a CM coupler and is rectified by D6006/D6007 (MA729X2). The resulting DC is fed through Auto- matic Power Controller Q1038 (NJM2902V), Q1001 (2SC

38、4154E), Q1004 (2SB1132Q) to control the gain of the transmitter RF amplifier and thus regulate the power output. Generation of spurious products by the transmit- ter is minimized by the fundamental carrier frequen- cy being equal to the final transmitting frequency, modulated directly in the transmi

39、t VCO. Additional harmonic suppression is provided by a low-pass fil- ter consisting of L6009/L6010/L6011 and C6042/ C6043/C6044/C6047/C6074/C6075 and C6045, result- ing in more than 65 dB of harmonic suppression pri- or to delivery of the RF energy to the antenna. DCS Demodulator DCS signals are de

40、modulated on the MAIN- UNIT, and are applied to low-pass filter Q2110 (NJM2902V), as well as the limiter comparator Q2110 (NJM2902V). CTCSS Encoder/Decoder The CTCSS code is generated and encoded by MPU IC Q2019 (MB90F583B). Demodulation and detection of the CTCSS tones are carried out by IC Q2013 (

41、MX165C). MPU Operation is controlled by 16-bit MPU IC Q2026 (MB90F583B). The system clock uses a 16.000 MHz crystal for a time base. IC Q2036 (RN5VL35AA) re- sets the MPU when the power is on, and monitors the voltage of the regulated 5V power supply line. EEPROM The EEPROM retains Tx and Rx data fo

42、r all mem- ory channels, as well as CTCSS data, DCS data, pres- caler dividing, and REF oscillator data (internal/ex- ternal). 5-1 Alignment The VX-6000 has been carefully aligned at the fac- tory for the specified performance across the frequen- cy range specified for each version. Realignment shou

43、ld therefore not be necessary except in the event of a component failure, or when altering the transceiver version. If a sudden prob- lem occurs during normal operation, it is likely due to component failure; realignment should not be done until after the faulty component has been re- placed. All co

44、mponent replacement and service should be performed only by an authorized VERTEX STANDARD representative, or the warran- ty policy may be voided. Therefore, if a fault is sus- pected, contact the dealer from whom the transceiv- er was purchased for instructions regarding repair. Authorized VERTEX ST

45、ANDARD service tech- nicians realign all circuits and make complete per- formance checks to ensure compliance with factory specifications after replacing any faulty components. Those who do undertake any of the following align- ments are cautioned to proceed at their own risk. Problems caused by una

46、uthorized attempts at re- alignment are not covered by the warranty policy. Also, VERTEX STANDARD must reserve the right to change circuits and alignment procedures in the interest of improved performance, without notify- ing owners. Under no circumstances should any alignment be attempted unless th

47、e normal function and operation of the transceiver are clearly understood, the cause of the malfunction has been clearly pinpointed and any faulty components replaced, and the need for realignment determined to be absolutely necessary. Required Test Equipment The following test equipment (and thorou

48、gh fa- miliarity with its correct use) is necessary for com- plete realignment. Correction of problems caused by misalignment resulting from use of improper test equipment is not covered under the warranty poli- cy. While most steps do not require all of the equip- ment listed, the interactions of s

49、ome adjustments may require that more complex adjustments be per- formed afterwards. Do not attempt to perform only a single step unless it is clearly isolated electrically from all other steps. Have all test equipment ready before beginning, and follow all of the steps in a sec- tion in the order presented. ? RF signal generator: calibrated output level at 1000 MHz ? Deviation Meter (linear detector) ? AF Millivoltmeter ? SINAD Meter ? In

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 火腿一族 > Profesional

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号