1、VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUAL VXR-9000V-H VXR-9000U-H OPERATING MANUAL RACK MOUNT REPEATER Vertex Standard LMR, Inc. VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUAL VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUAL The VXR-9000 x-H is commercial-grade 100-watt FM

2、 repeater designed to provide reliable two-way full-duplex com- munications over a wide range of environmental conditions. Designed to mount in a standard 19-inch rack, the VXR-9000 x-H is crafted using the latest computer-aided design and manufacturing processes, to ensure a high level of reliabili

3、ty to users. Important channel frequency data is stored in EEPROM, and is easily programmable by a Servicing Technician or Dealer using an IBM compatible personal computer and the FIF-10A (or FIF-12) + CT-104A USB Programming Interface and CE60 Software. Please take a few minutes to read this manual

4、 carefully. The information presented here will allow you to derive maximum performance from your VXR-9000 x-H. After reading it, keep this manual handy for quick reference, in case questions arise later on. Important Note: Internal service work, programming, and accessory installations should only

5、be performed by your authorized Vertex Standard Dealer. Dangerous conditions and/or possibly illegal operation may result from im- proper setup, programming, or internal modifications. SAFETY / WARNING INFORMATION The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent st

6、ructures with a separation distance of at least 1.98 m (VXR-9000V-H) or 1.62 m (VXR-9000U-H) from all persons during normal operation and must not exceed an antenna gain of 0 dBd. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exc

7、eeding a maximum trans- mitting duty factor of 50%. The antenna(s) used with this device must satisfy the antenna co-location require- ments of 47 C.F.R. 1.1307(b)(3). NOTICE! ?Do not modify this repeater for any reason. Refer service of this repeater to qualified technicians only. ?When the repeate

8、r become abnormal, such as the overheating, smoke smell of burning, etc., turn the main power switch off and disconnect the Main Power Source connector from the rear of the VXR-9000 x-H immediately. Also disconnect any backup power source you may have connected to the rear of the VXR- 9000 x-H. ?Do

9、not place any combustible material near the repeater. ?Do not spray any liquid over the repeater. ?Ensure that the power and antenna connections are securely made, using cables with excess capacity for the power being utilized. INTRODUCTION Page 1 VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANU

10、AL FRONT PANEL CONTROLS & CONNECTORS ?POWER (O/I) Switch This is the main power switch for the repeater. ? Power Indicator (MAIN) This LED glows green when the main power source is used. ? Power Indicator (BACKUP) This LED glows red when the backup power source is used. ? MIC Jack Connect the microp

11、hone plug to this jack. This jack is also used for writing and reading channel fre- quency or other configurations via the USB Port of the PC on which the clone editor (CE60) is running. ? Programmable Function (PF) Key Six pushbuttons on the front panel are program- mable function (PF) keys, each w

12、ith an orange in- dicator inside. Each key can be programmed with two functions, one for a “long” press and one for a “momentary” press. The PF key functions may be customized, via programming by your VERTEX STANDARD dealer, to meet your communications network requirements. Note that some functions

13、may require the purchase of optional internal ac- cessories. ? VOL Knob This control knob adjusts the output level of the front speaker and external speaker jack on the back panel. ? TX Indicator This LED glows red when the repeater is transmit- ting. ? Numeric Display This display consists of two 7

14、-segment LEDs, indi- cating the channel number during normal operation. If an abnormal condition arises, an error code will be displayed: Page 2 DISPLAYDESCRIPTION 01 - 32Channel Number PCClone Active ULPLL Unlock HIHigh temperature in PA Unit SCScan Active LCFront Panel Keys are Locked E1PTT key is

15、 Disabled E2Cooling Fan is Disabled E5Low Voltage in Backup Battery E7PA Unit Abnormality E3, E4, E6, E9Contact your Dealer ? BUSY Indicator This LED glows green when the receiving channel is busy. ? Speaker The internal speaker is located here. ? ? ? ? ? ? VXR-9000V-H / VXR-9000U-H FM REPEATER OPER

16、ATING MANUAL REAR PANEL CONNECTORS ?TX Antenna Jack This N-type coaxial jack provides the transmitter output signal, for connection to the transmitting an- tenna, or the “TX” jack on the duplexer. The output impedance requirement is 50 Ohms. ? Backup Power Source Terminals If available, a backup 13.

17、6 Volt power source, such as a rechargeable battery, may be connected here. When the Battery Charge switch (located on the 100W PA Unit) is set to “ON,” a “trickle” charge current is present here while the repeater is operat- ing from the “Main Power Source.” ? Circuit Protection Fuse Two 40-Amp bla

18、de fuses, for the “Main” and “Backup” power sources, are installed here. ? RX Antenna Jack This BNC-type coaxial jack accepts the receiver in- put signal, for connection to the receiving antenna, or the “RX” jack on the duplexer. The input imped- ance requirement is 50 Ohms. ? Main Power Source Conn

19、ector The primary DC power source should be connected here. The power requirements are 13.6 V DC at 30 Amps, continuous duty. ? External Speaker Jack This 3.5-mm, 2-pin jack provides variable audio output for an external speaker. The audio output impedance at this jack is 4 to 16 Ohms, and the level

20、 varies according to the setting of the front panels VOL knob. ? DSUB 25-pin Accessory Connector This DB-25F connector allows the repeater to be re- mote-controlled by an external controller. Analog I/ O signals, such as TX Audio In, Discriminator Out- put, RSSI, etc. are available. Moreover, the VX

21、R- 9000 x-H provides eight ports that can be pro- grammed for various input or output signals, or for control functions. Each port may be programmed as to its function, its status (input or output), and its logic (for output ports only). Page 3 ? ? ? VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING M

22、ANUAL Antenna Considerations Repeater operation requires two antennas, one for re- ceiving and one for transmitting, so that the receiving antenna does not absorb energy from the transmitting antenna. There are a number of ways to do this, depend- ing on the TX/RX frequency separation, and on the lo

23、- cations available for antenna mounting. Regardless of the above choice, it is of paramount im- portance that the antenna(s) be mounted as high and in the clear as possible, preferably within line-of-sight to all repeater users. Furthermore, losses in the feedline(s) must be minimized, so the feedl

24、ine(s) should be high quality, and as short as possible. If a long feedline is necessary, use coaxial “hardline” cable to reduce losses. Repeater antennas should have an impedance of 50 at the operating frequency. When separate receive and transmit antennas are used, high-Q narrow-band types may ser

25、ve to minimize interaction. NEVER TRANSMIT WITHOUT HAVING A TRANSMIT ANTENNA CONNECTED TO THE TX ANTENNA JACK OF THE REPEATER. Equipment Location The VXR-9000 x-H must be installed in a 19-inch Mount- ing Rack, which will allow for free air flow around the heat sink of the 100 W PA Unit at all times

26、. In warm climates, the repeater should not be sealed in a small, closed room without air conditioning. While the operating temperature range of the VXR- 9000 x-H is quite broad, the best location is one in which the air temperature does not approach the extremes of the specified range, and one that

27、 does not change rap- idly. Protect the VXR-9000 x-H (Mounting Rack) from wind and rain, and extremes in temperature or humidity that may shorten the useful life of the equipment. Try to lo- cate the VXR-9000 x-H (Mounting Rack) in an environ- ment that is also comfortable for service personnel, if

28、possible. INSTALLATION Page 4 VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUAL Power Supply Operation of the VXR-9000 x-H requires a power source capable of providing at least 30 Amps continuously at 13.6 Volts DC. Please prepare the regulated power sup- ply which satisfies the above voltage a

29、nd current speci- fications. Use the DC power cable (VXSTD P/N: T9207279) sup- plied with your repeater for making power connections to the power supply. Connect the RED power cable lead to the POSITIVE (+) power supply terminal, and con- nect the BLACK power cable lead to the NEGATIVE ( ) power sup

30、ply terminal. INSTALLATION Backup Power Supply For uninterrupted operation during power failures, a 12-volt rechargeable type battery (55-Ah or more rec- ommended) may be connected to the BACKUP termi- nal posts on the rear panel. While the repeater is oper- ating from the Main Power Source a slight

31、 charging current will maintain battery charge. In the event of an unexpected interruption of the Main Power Source, the automatic power control circuit will automatically switch the repeater to the backup battery, and opera- tion will not be interrupted. After prolonged operation from the battery,

32、(Backup Power Source), it should be disconnected from the re- peater and recharged separately before re-connecting, as the trickle charge is not sufficient for recharging a completely discharged battery. Never reapply the Main Power Source to the repeater with a discharged battery connected as backu

33、p, as the DC startup current can damage the repeater and bat- tery. Never short the “Backup Power Sorce” Terminals, when the Battery Charge switch (located on the Relay Unit) is set to “ON.” TYPICALLY SETUP Page 5 ? To TX Antenna ? To RX Antenna Supplied DC Power Code (T9207279) RED BLACK RED BLACK

34、Backup Battery (12 V, 55 Ah) Power Supply (13.6 V, 40 50 A) VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUAL NOTE Page 6 VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUAL NOTE Page 7 VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUALPage 8 WARRANTY POLICY Vertex Standard warrants, to

35、the original purchaser only, its Vertex Standard manufactured communications prod- ucts against defects in materials and workmanship under normal use and service for a given period of time from the date of purchase. Limited Warranty Details: ?North America customers (USA and Canada): ?Customers outs

36、ide of North America: contact the authorized dealer in your country. VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUAL Part 15.21: Changes or modifications to this device not expressly ap- proved by Vertex Standard could void the users authorization to operate this device. VXR-9000V-H / VXR-9000U-H FM REPEATER OPERATING MANUAL Copyright 2013 Vertex Standard LMR, Inc. All rights reserved. No portion of this manual may be reproduced without the permission of Vertex Standard LMR, Inc. Printed in JapanEAE21N104