1、 AR-ONE Ultra Wide Band Communications Receiver Operating manual AOR, LTD. Downloaded by? Amateur Radio Directory? ? www.hamdirectory.info 1 Table of contents 1 Introduction - 4 1-1 Introduction - 4 1-2 Take care of your radio - 5 1-3 Attention while operating - 6 1-4 Accessories supplied - 8 1-5 Co
2、ntrols and functions - 9 1-5-1 Keypad - 11 1-5-2 Summary of keys - 11 1-6 Computer control - 14 1-7 IF output and Spectrum Display Unit (SDU5500, SDU5600) - 14 2 Getting Started - 14 2-1 Making the AR-ONE ready for operation - 14 2-1-1 LCD - 14 2-1-2 Connect the antenna - 14 2-1-3 Connect power - 15
3、 2-2 Switching on for the first time - 15 2-3 Squelch Circuit - 15 2-4 VFO selection - 16 2-4-1 Tuning frequency - 16 2 2-4-1-1 Entering frequency using the numeric keypad - 16 2-4-1-2 Changing frequency using the main tuning dial - 16 2-4-1-3 Changing frequency using UP arrow key or DOWN arrow key
4、- 17 2-5 Changing receive mode - 17 2-5-1 Auto mode selection - 19 2-5-2 Receive mode selection - 20 2-6 Changing tuning step size - 20 2-7 IF bandwidth - 21 2-7-1 Manually selecting IF band width - 22 2-8 AGC (Automatic Gain Control) - 22 2-9 ATT (Attenuator) - 23 2-10 RF Amplifier - 24 2-11 OFFSET
5、 - 25 2-11-1 Using pre-programmed frequency offset data - 25 2-11-2 Entering new frequency offset data - 26 3 Memory channels and banks - 27 3-1 Memory channel overview - 27 3-2 Storing VFO frequency and data into memory - 28 3-3 Memory read “M.RD” - 30 3-4 Deleting memory channels - 31 4 SCAN scann
6、ing memory channels - 31 4-1 SCAN outline introduction - 31 4-2 Starting SCAN - 3 32 4-3 Selecting a SCAN bank - 32 4-4 Select SCAN - 32 4-4-1 Adding select scan channels in memory read - 32 4-4-2 Starting/Stopping select scan - 33 5 Search mode - 34 5-1 Search type - 34 5-1-1 Program search overvie
7、w - 34 5-2 Starting Program search - 34 5-2-1 Reversing the direction of search - 35 5-2-2 Forcing the search to resume - 35 5-2-3 Stopping the search - 36 5-3 Selection of search bank - 36 5-4 Programming a search bank - 36 5-5 Deleting search banks - 41 5-6 Locking out unwanted active frequencies
8、(PASS) - 43 5-6-1 Deleting pass channels - 43 6 Configuration menu - 45 6-1 Configure beep - 45 6-2 Configure lamp - 46 6-3 Configure dimmer - 47 6-4 Configure contrast - 48 6-5 Configure manual AGC - 48 4 6-6 Configure IF-GAIN (Intermediate Frequency gain) - 49 6-7 Configure RF-GAIN (Radio Frequenc
9、y gain) - 50 6-8 Configure Remote BPS (Baud Rate) - 50 6-9 Configure RMT-ID (Remote ID) - 51 6-10 Configure DELAY (Scan delay and Search delay) - 52 6-11 FREE (Scan free and Search free) - 53 6-12 Configure SPEAKER - 53 6-12-1 Configure rear speaker - 53 6-12-2 Configure front speaker - 54 6-12-3 Co
10、nfigure headphones output - 55 6-13 Configure audio filters (HPF/LPF) - 55 6-13-1 Configure audio HPF (High Pass Filter) - 55 6-13-2 Configure audio LPF (Low Pass Filter) - 56 6-14 Configure Audio De-emphasis - 57 6-15 Configure PRIO-CH (Priority Channel) - 58 6-15-1 Engaging PRIO channel - 58 6-16
11、Configure IF output frequency - 59 6-16-1 Selecting IF output frequency - 59 6-17 Configure reference signal source - 60 7 Computer control - 61 7-1 How to send an RS-232C command - 61 7-2 Power on the AR-ONE - 61 7-3 Detailed RS-232C Command Listing of the AR-ONE - 5 62 8 Specifications - 75 9 Opti
12、onal Accessories - 76 10 Limited Warranty - 77 1 Introduction 1-1 Introduction Thank you for purchasing the AR-ONE Ultra Wide Band Communications receiver. The AR-ONE is designed using the very latest technology to ensure the highest levels of performance and reliability. To get the best possible re
13、sults from your AR-ONE, we strongly recommend you to read this manual and familiarize yourself with the receiver. Although carefully designed, this receiver (like all receivers) suffers from a degree of internal noises known as spurious emission. They are a product of the receivers circuitry, and th
14、erefore, it does not represent a fault. Apparent faults may be due to accidental misoperation of the receiver. If you believe there is a problem, carefully read 6 all of the manual before deciding to contact your dealer for advice. It is acknowledged that sections of this manual are repetitive, this
15、 is to enable the manual to be used as a reference book (you dont have to read it all from cover to cover in one go). Due to the international nature of the product, some graphics contain Japanese characters. Every effort has been made to make this manual correct and up to date. Due to continuous de
16、velopment of the receiver. and by error or omission anomalies may be found and this is acknowledged. This manual is protected by copyright AOR, LTD. 2003. No information contained in this manual may be copied or transferred by any means without the prior written consent of AOR, LTD. AOR and the AOR
17、logo are trademarks of AOR, LTD. All other trademarks and names are acknowledged. Main features: ?Super wide coverage: 10 KHz 3.3 GHz (continuous) ?1,000 memory channels ?10 VFOs ?Monitor AM, NFM, WFM, USB, LSB, CW, Data ?Ultra-stable reference frequency oscillator ?Two RS-232C ports plus control he
18、ad port ?Control up to 99 AR-ONE Units with one PC ?Triple conversion superheterodyne front end ?Antenna input level readout ?Adjustable BFO ?High intercept ?IF signal output (10.7 MHz or 455KHz) ?Excellent sensitivity ?Detachable control head (optional kit required) 7 1-2 Take care of your radio Th
19、ere are no internal operator adjustments. In the unlikely event of servicing being required, please contact your dealer for technical assistance. Do not use or leave the receiver in direct sunlight (especially the LCD). It is best to avoid locations where excessive heat, humidity, dust and vibration
20、 are expected. Always keep the AR-ONE free from dust and moisture. Use a soft, dry cloth to gently wipe the set clean, never use abrasive cleaners or organic solvents which may damage certain parts. Treat the AR-ONE with care, avoid spillage or leakage of liquids into the receiver and associated pow
21、er supply. Special care should be taken to avoid liquid entering around the controls, through the speaker grille or via the connection jacks. The AR-ONE is designed for operation from a good quality regulated DC supply of 12 to 14 V, which should be capable of supplying 1.5 amps. Never connect the A
22、R-ONE directly to the AC outlet. The DC input jack is configured Center Positive, the chassis of the receiver is at negative ground. Where provided (depending upon world market location), the power supply is pre-wired and provides a nominal 12 V DC output with suitable connectors being fitted as sta
23、ndard for the AC power input and connection to the AR-ONE. SAFETY NOTICE Always disconnect the power supply from the AC outlet when not in use. If used mobile, it should be noted that the AR-ONE has NOT been manufactured or tested to meet any specific mobile safety requirements. The AR-ONE has no in
24、ternally user adjustable parts. If using the AR-ONE in a base station situation, the best short wave reception is usually achieved by the fitting of a separate external earth rod, however, consider the implications carefully if your AC building supply uses a Protective Multiple Earth (PME) system. I
25、f in doubt consult an expert electrician. Never earth to a gas pipe! The AR-ONE has a single N type antenna connector for all frequencies. This is intended for connection to a 50 ohm (unbalanced) coaxial fed antenna such as a discone, dipole, 8 unipole, Yagi, etc. When sighting the antenna, avoid po
26、wer cables. Ensure that you do not confuse the antenna and other IF output connectors as they are closely located. Operating anomalies Should the AR-ONE appear to behave strangely, normal operation may be easily achieved by resetting the microprocessor. Two scenarios may be encountered due to power
27、transients etc: 1. Symptom: LCD remains on, no control of the keypad. Action: Remove any connection to external power and leave it for approximately 30 seconds. Reconnect power and switch on again. Normal operation should be restored but the last used frequency will be lost, the AR-ONE will restore
28、the last but one frequency to display. 2. Symptom: The AR-ONE fails to power up. Action: Try the suggestions given in (1) then hold the ESC key while powering up the AR-ONE to Soft reset the microprocessor. 1-3 Attention while operating 1. Certain key operation are acted upon when the key is RELEASE
29、D, not while it is pressed. Allow time for the AR-ONE to register such actions before pressing another key. 2. The keylock (LOCK) is intentionally made to be difficult to operate to prevent accidental operation. To release keylock, the LOCK key has to be held for more than one second, the key icon o
30、n the LCD confirms operation. The LOCK is disabled during keying sequences (such as when entering frequencies). 3. If a key sequence is not completed, the microprocessor will automatically abort most operations after about 90 seconds of keypad inactivity. 4. Currently displayed VFO data is saved at
31、power down (to increase speed of operation and to reduce write cycles). For this reason, if the AR-ONE is powered down using the PWR/VOL control or external power is removed, the last displayed frequency will be lost and the frequency used prior to this will be displayed when next powered up. Terminology Search & Scan 9 If you have not used a wide band receiver