Vertex_VX-4000_user.pdf

上传人:cc518 文档编号:198361 上传时间:2025-03-08 格式:PDF 页数:31 大小:584.44KB
下载 相关 举报
Vertex_VX-4000_user.pdf_第1页
第1页 / 共31页
Vertex_VX-4000_user.pdf_第2页
第2页 / 共31页
Vertex_VX-4000_user.pdf_第3页
第3页 / 共31页
亲,该文档总共31页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Vertex_VX-4000_user.pdf》由会员分享,可在线阅读,更多相关《Vertex_VX-4000_user.pdf(31页珍藏版)》请在收音机爱好者资料库上搜索。

1、VX-4000 OPERATING MANUAL MANUAL DE OPERACIN VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 17210 Edwards Rd., Cerritos, CA 90703, U.S.A. International Division 8350 N.W. 52nd Terrace, Suite 201, Miami, FL 33166, U.S.A. YAESU EUROPE B.V. P

2、.O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD. Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. YAESU GERMANY GmbH Am Kronberger Hang 2, D-65824 Schwalbach, Germany VERTEX STANDARD HK LTD. Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun

3、 Tong, Kowloon, Hong Kong POWER English Congratulations! You now have at your fingertips a valuable communications tool - a two-way radio! Rugged, reliable and easy to use, your radio will keep you in constant touch with your colleagues for years to come, with negligible maintenance down time. Pleas

4、e take a few minutes to read this manual carefully. The information presented here will allow you to derive maximum performance from your radio. After reading it, keep the manual handy for quick reference, in case questions arise later on. Were glad you joined the team. Call on us any time, because

5、our business is communications. Let us help you get your message across. NOTICE There are no user-serviceable points inside this transceiver. All service jobs must be referred to your Authorized Service Center or Network Administrator. Safety / Warning Information WARNING - DO NOT operate the VX-400

6、0V/U radio when someone (bystand- ers) outside the vehicle is within following range. Safety Training information: Antennas used for this transmitter must not exceed an antenna gain of 0 dBd. The radio must be used in vehicle-mount configurations with a maximum operating duty factor not exceeding 50

7、%, in typical Push-to-Talk configurations. This radio is restricted to occupational use, work related operations only where the radio operator must have the knowledge to control the exposure conditions of its passengers and bystanders by maintaining the minimum separation distance of following range

8、. Failure to observe these restrictions will result in exceeding the FCC RF exposure limits. Antenna Installation: For rear deck trunk installation, the antenna must be located at least following range away from rear seat passengers in order to comply with the FCC RF exposure requirements. For roof

9、top installation, the antenna must be placed in the center of the roof. Radiated frequency and Distance VX-4000VVX-4000U (A)VX-4000U (D)VX-4000U (F) 3.27 Feet (0.997 m) 2.83 Feet (0.864 m) 2.67 Feet (0.814 m) 2.58 Feet (0.788 m) Page 1 VX-4000 Operating Manual VX-4000 Operating Manual The VX-4000 Se

10、ries are full-featured FM transceivers designed for flexible mobile and base station business communications in the VHF (50/25 Watts: programmable) and UHF (40/25 Watts: programmable) Land Mobile Bands. Each model is designed for reliable business communications in a wide variety of applications, wi

11、th a wide range of operating capability provided by its leading-edge design. The 250-channels memories can each be programmed with a 8-character channel name. Important channel frequency data is stored in EEPROM and flash memory on the CPU, and is easily programmable by dealers using a personal comp

12、uter and the VERTEX STAN- DARD CT-71 Programming Cable and CE35 Software. The pages which follow will detail the many advanced features provided on the VX-4000 transceiver. After reading this manual, you may wish to consult with your Network Ad- ministrator regarding precise details of the configura

13、tion of this equipment for use in your application. POWER For North American Users Regarding 406 MHz Guard Band The U.S. Coast Guard and National Oceanographic and Atmospheric Administration have requested the cooperation of the U.S. Federal Communications Commission in preserving the integrity of t

14、he protected frequency range 406.0 to 406.1 MHz, which is reserved for use by distress beacons. Do not attempt to program this apparatus, under any circumstances, for operation in the frequency range 406.0 - 406.1 MHz if the apparatus is to be used in or near North America. Page 2 VX-4000 Operating

15、Manual CONTROLS background noise will now be heard, and you may use this to set the VOL- UME knob for the desired audio level. Press and hold the MON button more than 1/2 seconds to quiet the noise and resume normal (quiet) monitoring. Transmitting To transmit, wait until the “BUSY” indicator is off

16、 (the channel is not in use), and press the PTT (Push-To-Talk) switch on the side of the microphone (the “TX” indica- tor will appear or the “TX” indicator will glow red). While holding in the PTT switch, speak across the face of the microphone in a clear, normal voice level, and then release the PT

17、T switch to receive. Selecting Groups and Channels H Press the UP (?) or DOWN (?) button (repeatedly, if necessary) to select a different group of channels. H Turn the CHANNEL selector knob to select a different channel within the current group. Automatic Time-Out Timer If the selected channel has b

18、een programmed for automatic time-out, you must limit the length of each transmission. While transmitting, a beep will sound five seconds before time-out. Another beep will sound just before the deadline; the “TX” indicator will disappear and transmission will cease soon thereafter. To resume transm

19、itting, you must release the PTT and wait for the “penalty timer” to expire (if you press the PTT before this timer expires, the timer restarts, and you will have to wait another “penalty” period) Page 6 VX-4000 Operating Manual POWER ADVANCED OPERATION Programmable Function Button (PF button) The V

20、X-4000 includes the seven Programmable Function Buttons (PF button). The PF button functions can be customized, via programming by your VERTEX STAN- DARD dealer, to meet your communications/network requirements. Some features may require the purchase and installation of optional internal accessories

21、. The possible PF button programming features are illustrated at the below, and their functions are explained on page 8. For further details, contact your VERTEX STANDARD dealer. For future reference, check the box next to each function that has been assigned to the PF button on your particular radi

22、o, and keep it handy. Functions Programmable Function Button (PF button) None SCAN (SCN) Dual Watch Call/Reset Talk-Around (TA) Alpha Numeric (A/N) DIMMER (DIM) Emergency (EMG) Horn Alert (HA) Home Channel (HOM) Intercom (IC) Low Power (LOW) GRP UP GRP DWN CH UP CH DWN AUX A AUX B AUX C Public Addre

23、ss (PA) Monitor (MON) 1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec Page 7 VX-4000 Operating Manual ADVANCED OPERATION 1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec1.5 sec Functions Programmable Function Button (PF button) RCL Selectable Tone (ST) SP* Squelch Level (SQL) Encryption* (OPT) * require

24、s RMK-4000 * requires Encryption Unit Channel Scan The Scanning feature is used to monitor multiple signals programmed into the trans- ceiver. While scanning, the transceiver will check each channel for the presence of a signal, and will stop on a channel if a signal is present. To activate scanning

25、: H Press the assigned PF button of the “Scan” momentarily to activate scanning. H The scanner will search the channels, looking for active ones; it will pause each time it finds a channel on which someone is speaking. To stop scanning H Press the assigned PF button of the “Scan”. H Operation will r

26、evert to the channel to which the CHANNEL selector knob is set. Note:Your dealer may have programmed your radio to stay on one of the following channels if you press the PTT switch during scanning pause: Current channel (“Talk Back”) “Last Busy” channel “Priority” channel “Home” channel “Scan Start”

27、 channel Dual Watch The Dual Watch feature is similar to the Scan feature, except that only two channels are monitored: The current operating channel; and The “Priority” channel. To activate Dual Watch: H Press the assigned PF button of the “Dual Watch”. H The scanner will search the two channels; i

28、t will pause each time it finds a channel on which someone is speaking. To stop Dual Watch: H Press the assigned PF button of the “Dual Watch”. H Operation will revert to the channel to which the CHANNEL selector knob is set. Page 8 VX-4000 Operating Manual ARTS (Auto Range Transpond System) This sy

29、stem is designed to inform you when you and another ARTS-equipped station are within communication range. During ARTS operation, your radio automatically transmits for about 1 second every 25 (or 55) seconds (the interval is programmed by Dealer) in an attempt to Shake hands with the other station.

30、If you move out of range for more than one minutes, your radio senses that no signal has been received, a ringing beeper will sound. If you subsequently move back into range, as soon as the other station transmits, your beeper will sound. The PF Button Function The PF (Programmable Function) button

31、can be programmed by the dealer to provide two of the other functions described below. To activate the primary Accessory function, press the PF button momentarily. To access the secondary Accessory function (which may include the Alarm), press and hold the PF button for 1.5 seconds or longer. Call/R

32、eset When this feature is programmed and a selective call has been received, momen- tarily press the assigned PF button of the “Call/Reset” to reset the flashing indicator and mute the receiver, otherwise press the assigned PF button of the “Call/Reset” to sent your radios identification code (ANI)

33、to the dispatcher. Talk-Around The feature causes the assigned PF button of the “Talk-Around” to select simplex operation on semi-duplex channels: the transmit frequency becomes the same as the receive frequency (regardless of any programmed offset for the channel). Note:This feature has no effect o

34、n simplex channels. After pressing the button, “TA” is displayed on the LCD. Alpha Numeric Press the assigned PF button of the “Alpha Numeric” to switch the display between the Group/Channel number, and the Group/Channel name (alphanumeric). A tone will sound each time you switch between numerical a

35、nd alphanumerical display. DIM Press the assigned PF button of the “DIM” to adjust the brightness of the display and key backright. ADVANCED OPERATION Page 9 VX-4000 Operating Manual EMG (Emergency) Press the assigned PF button of the “EMG” to initiate an emergency call (requires ANI board). When an

36、 emergency call is made, not tone is emitted and the display does not change. To end the emergency call, turn the transceiver power OFF. HA (Horn Alert) Press the assigned PF button of the “HA” to turn the Horn Alert function ON or OFF. If you receive a call from the base station with 2Tone or DTMF

37、signaling, horn alert will activate. When you turn Horn Alert ON, a tone will sound and “ ” appears on the display. Home (Home Channel) Press the assigned PF button of the “Home” to select the pre-programmed Home Channel. Press it again to return to the previous channel. If used while scanning, pres

38、sing this key a second time will change to the revert channel. IC (Intercom) This feature requires dual head configuration. Press the assigned PF button of the “IC” to turn the intercom feature ON or OFF. While ON, you can press the PTT switch to communicate to another control head operator without

39、transmitting over the air. When you press this key, a tone sounds and “” appears on the display. The intercom can be used even while scanning and receiving a call Low Power Press the assigned PF button of the “Low Power” to set the radios transmitter to the “Low Power” mode. Press this key again to

40、return to “High Power” operation when in difficult terrain. GRP UP/DWN Press the assigned PF button of the “GRP UP” or “GRP DWN” to select a different group of channels. CH UP/DWN Press the assigned PF button of the “CH UP” or “CH DWN” to select a different channel within the current group. AUX A/B/

41、C Press the assigned PF button of the “AUX A”, “AUX B”, or “AUX C” to turn the output port (respectively). PA (Public Address) Press the assigned PF button of the “PA” to use the transceiver as a PA amplifier. When you enable this function, a tone sounds and “” appears on the display. The public add

42、ress can be used even while scanning and receiving a call. ADVANCED OPERATION Page 10 VX-4000 Operating Manual MONI (Monitor) Press the assigned PF button of the “MONI” momentarily to cancel CTCSS and DCS signaling squelch; the “MON” icon appears on the display. Press and hold this key for 1/2 secon

43、ds to hear background noise (unmute the audio); the MON icon blinks on the display. RCL (Channel Recall) During scan, you can press the assigned PF button of the “RCL” to select the last called channel. ST (Selectable Tone) Press the assigned PF button of the “Selectable Tone”, then rotate the CHANN

44、EL selector knob to select a 2-Tone. SP Press the assigned PF button of the “SP” to switch “Front panel”, “Front panel tal accin le permitir escuchar el ruido de fondo, el cual puede utilizar para ajustar el control de volumen en el nivel de audio deseado. Posteriormente, presione MON una vez ms por

45、 segundo para apagar el ruido de fondo y continuar escuchando las emisiones en forma normal (o silenciosa). Transmisin Para transmitir, espere hasta que se apague el indicador “BUSY” (al desocuparse el canal) y luego presione el conmutador del PTT (Push To Talk) ubicado en el costado del micrfono (e

46、n este caso, el icono de “TX” aparece exhibido en la pantalla o bien, dicho indicador se ilumina de color rojo sobre el panel). Mientras sostiene el conmutador del PTT, hable por el frente del micrfono con un tono de voz clara y normal; suelte posteriormente dicho interruptor para recibir. Seleccin

47、de Grupos y Canales H Presione el botn de seleccin ascendente (?) o descendente (?) (varias veces si fuera necesario) para escoger un grupo distinto de canales. H Gire la perilla selectora “CHANNEL” para escoger un canal distinto dentro del grupo vigente. Temporizador Automtico de Intervalos de Tran

48、smisin El usuario debe limitar la duracin de sus transmisiones si el canal seleccionado ha sido programado para que se desconecte automticamente al final del intervalo de retardo. Mientras transmite, el transceptor genera un pitido cinco segundos antes de efectuar la desconexin y vuelve a emitir otr

49、o sonido al cumplirse ese plazo; cuando esto sucede, el indicador de “TX” desaparece del despliegue, interrumpindose de all en adelante todo tipo de emisin. Con el fin de reanudar sus transmisiones, suelte el PTT y espere que expire el ciclo del “temporizador penal” (si presiona el PTT antes de que dicho dispositivo termine de contar, ste reiniciar su ciclo y usted tendr que esperar hasta que expire el prximo perodo “punitivo”) Pgina 6 VX-4000 Manual de Instrucciones POWER FUNCIONAMIENTO AVANZADO Botn de Funciones Programable (Botn PF) El VX-4000 cuenta con siete Botones d

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 火腿一族 > Profesional

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号