《Samyung_SRG-3150DN_user.pdf》由会员分享,可在线阅读,更多相关《Samyung_SRG-3150DN_user.pdf(57页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Warning RF Exposure Warning : The radiated output power of this device is below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. In order to avoid the possibility of exceeding
2、 the FCC radio frequency exposure limit, human proximity to the antenna should not be less than 20cm during normal operation. Information to user The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly app
3、roved by the party responsible for compliance could void the users authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in tha
4、t alternative form, provided the user can reasonably be expected to have the capability to access information in that form. 1 Contents SRG-3150DN Rev.1.1(080409) SRG-3150DN How to operate basic function and Distress transmitting 1. Set MMSI ID . 5 1.1. Self-ID . 5 2. SSB mode . 5 2.1. Channel Select
5、ion . 5 2.2. Frequency Selection . 5 2.3. TX, RX . 5 3. DSC mode. 5 3.1. Channel Selection . 5 3.2. Frequency Selection . 5 3.3. Call . 6 3.4. DSC Message RX Auto Reply . 6 4. Distress transmit . 6 How to use SN-100 NBDP Terminal 1. Selection of Channel . 6 2. Selection of Frequency . 6 3. ARQ mode
6、. 6 4. FEC mode . 6 Chapter 1. Overview . 7 1.1. Features . 7 1.2. Basic Components . 8 Chapter 2. Specifications . 9 2.1. General specification . 9 2.2. MF/HF Transmitter . 9 2.3. MF/HF Receiver. 9 2.4. DSC (Digital Selective Calling) W/K Receiver .10 2.5. MF/HF Control .10 2.6. Digital Selective C
7、alling (DSC) .10 2.7. Narrow band direct Printing (NBDP) .11 2.8. Printer (DPU-414).11 2.9. Printer (OKI) .11 Chapter 3. Power Supply . 12 3.1. Power On .12 3.2. Operation by AC power.12 3.3. Operation by DC (BATTERY) power .12 3.4. BATTERY Charging .12 Chapter 4. Front Panel . 13 4.1. About Button,
8、 Knob, Lamp .13 4.2. LCD display .14 4.3. LCD display flow .15 Chapter 5. SSB (TEL) mode . 16 5.1. SSB Mode .16 5.2. SSB Menu .16 (1) Scan Type Set .16 (2) Scan Channel Set .16 (3) Scan Frequency Set .16 2 (4) SQL Set .16 (5) LCD Contrast Set .17 (6) Tx Power Set .17 (7) Manual Tuning.17 (8) ATU Ver
9、sion (ATU Program Version) .17 (9) Remote Set .17 (10) System Set .17 5.3. Additional Functions (ITU Channel, AM mode, Etc.,) .18 Chapter 6. Digital selective calling (DSC) mode . 19 6.1. The selection of DSC mode .19 6.2. DSC menu display .19 (1) Distress msg edit .19 (2) Individual msg edit. .20 (
10、3) Group msg edit.21 (4) Geography msg edit .22 (5) Auto/Semi-AT msg edit .25 (6) Dist ack/rly msg edit .26 (7) Ordinary ack msg edit .28 (8) Display and print msg .28 (9) System Set .28 Chapter 7. Transmitter of distress signal. 32 7.1. Test of Distress alert signal .32 Chapter 8. RX of Distress th
11、erefore a large space is not required for installation and operation. SN-100 Terminal is able to use by connecting with SRG-3150DN cable. (5) Trustworthy Adopted new DDS (Direct Digital Synthesize) and improved the quality of sound, trustworthy, stability. (6) Construction In order to endure in bad
12、condition of marine environment, hard aluminum body is manufactured. (7) External Shape Channel, Frequency, Transmitting and receiving conditions can be seen on large LCD at one sight. And each key is made by soft rubber material. It has stylish shape and makes you feel comfortable when you press th
13、e button, Further there is frequency sheet for users. SN-100 NBDP Terminal has large, thin, colorful LCD and convenient keyboard. 8 1.2. Basic Components This equipment is composed of SRG-3150DN and SN-100(NBDP), each item is made by functional PCB and sorted by standard and option. No. Description
14、Model Qty Remark 1. EMG Light EMG-Light 1 2. External Speaker SS-6000 1 3. Power Supply SP-1250ADC 1 4. NBDP Teminail SN-100 1set SN-100 Assembly (Installation material included) (1) Connection Board T - 130 1 (2) NBDP T - 132 1 (3) NBDP PLL T - 133 1 (4) T - 025 1 (5) CPU Board G-1151 1 5. KEY Boar
15、d SPR8695 1 6. MF/HF Distress Box SD-250 1 (SCN-16-5P included) 7. Printer DPU-414 1 (Installation material included) (or OKI Printer) 8 WHIP ANT (TX) SAN-308 1 (8m) 9. WHIP ANT (RX) SAN-30R 1 (6m) No. Description Model Qty Remark 1. MF/HF-DSC SRG-3150DN 1set SRG-3150DN Assembly (1) MAIN BOARD T - 1
16、110 1 (2) TX FILTER T - 1101 1 (3) W/K RX T - 1112 1 (4) TX PA T - 1113 1 (5) KEY BOARD T - 1114 1 2. Automatic Antenna Tuner SAT-100 1 (Installation material included) 3. HAND MIC SM-1150 1 4. Accessory SSB-A-C,SRG-2050D-PC 1set 5. User, Installation Manual SRG-3150DN(Eng) 1 9 Chapter 2. Specificat
17、ions 2.1. General specification This radio equipment SRG-3150DN has been tested by the recommendation standard of IMO. (1) Power Supply (SP-1250ADC) AC 100-120/200-240V, 50/60Hz, 6% single-phase, DC24V Power Supply : 1200VA (Max) (2) Consumption Current: DC24V 15% Receiving: 2.5A, at transmitting: 1
18、5A (Max) (3) Frequency Selection a) ITU CHANNEL (Maritime Mobile) 271 b) 299 USER CHANNEL (Editable at the screen) or set frequency directly by keyboard. c) DSC CHANNEL 2187.5, 4207.5, 6312, 8414.5, 12577, 16804.5 kHz (FIB) is scan receiving all the time. d) DSC Channel 13EA (Editable). (4) Frequenc
19、y Switching Time: Between CHANNEL - within 5sec, Between BAND - within 15sec (Including ANTENNA MATCHING TIME) (5) Ambient Condition Temperature : -15 +55 Humidity: 95%, +55 Oscillation : Full amplitude 3.2mm at 5 12.5Hz Full amplitude 0.8mm at 12.5 25Hz Full amplitude 0.2mm at 25 50Hz (6) Dimension
20、s (mm) SRG-3150DN : 324(W) X 170(H) X 347(D) SN-100 : 300(W) X 255(H) X 125(D) (7) Weight SRG-3150DN about 8.1Kg SN-100 about 5 Kg SAT-100 about 3.4Kg 2.2. MF/HF Transmitter (1) Type of Emission : J3E (USB), F1B (FSK) (2) Type of Communication : SIMPLEX channel that is transmitting will be stop afte
21、r finishing the transmitting. Ref. MENU9.System Set1.Self ID Set If it didnt set and then flicker MMSI not entered on main screen and cant transmit. 33 Chapter 8. RX of Distress ATT, AGC, and FUNCTION KEYS are displayed. . SPEAKER : Alarm rings when it receives data or warning signal. . TX LED : Red
22、 light on TX LED . RX LED : Green light blinks while receiving data . POWER SWITCH : SN-100 Power ON/OFF 13.2. Initial Display of Telex (NBDP) mode ? Power on, indicate first display as followings (1) Initial screen function explanation Indicate calling channel and present channel Set transmitting f
23、requency Set receiving frequency Indicate adjusting portion as Bar Graph Adjust the portion of RF GAIN properly using up/down with direction keys. (0 100steps) The button to adjust the clarity of RX. Using direction button, increase or decrease to gain the best RX. (Adjustment range: 10Hz) Function
24、to reduce the RX gain. This function can be adjusted in 4 steps using up/down button. OFF : 0dBm, 2 : 20 dBm 1 : 10dBm, 3 : 30 dBm Adjust TX power HIGH/MID/LOW Profit of input signal ON/OFF automatically. Volume sound is displayed on Graphic bar (0100 levels) (2) Initial screen function button expla
25、nation 1 DIM : Adjust the lightness of back light on LCD display. (5 LEVEL) 2 LINK : Automatic Repeat request mode & FEC mode can be set up by F2 button 3 COMM : Call the registered frequency. 4 VOL- : Volume down the speaker. 5 VOL+ : Volume up the speaker. 6 CH : Set the frequency channel 7 TX: TX
26、 : Set TX frequency. 8 Rx: RX : Set RX frequency. 9 Tune : is used when user want to do matching to antenna. 0 Menu : Indicate Main Menu 0. ARQ : Communicate with Automatic Repeat Request Mode. 1. FEC : Communicate with 1 way Forward Error Correction. 2. Station Edit : Register the frequency of the
27、other station. 3. Station Print : Print out the frequency of registered the other station. 4. Macro Command : Write Macro command. (Write short sentence in 20 words) 5. Editor : Edit file and save content. 6. System set : Use while adjusting TELEX mode condition. CH TX RX BAR GRAPH RF GAIN CLARIFY A
28、TT TX Power AGC Vol GRAPH 44 7. NBDP Test : Transmitting signals of Dot, Mark, Space. Use for testing printer and NBDP TX/RX condition. 8. LCD-off (F12) : The function of LCD off and in the case that LCD is off, if any button is pressed, LCD is on. (3) Control function in Keyboard PgUp : Adjust chan
29、nel to next channel. But if next channel is not registered, it moves to next channel of it. PgDn : Adjust channel to forward channel. But, if forward channel is not registered, it moves to forward channel of it. 13.3. SettingUpTX/RX Frequency ? UNIT: kHz (1) Setting TX frequency a) Press F7 button on the keyboard. b) Input the frequency with Number button. Ref. While inputting frequency if press ?, ?, curser will move. c) Press Enter button. Ref. Available TX Frequency range: 1.6MHz 27.5MH