《Skanti_TRP1000_user.pdf》由会员分享,可在线阅读,更多相关《Skanti_TRP1000_user.pdf(28页珍藏版)》请在收音机爱好者资料库上搜索。
1、 ii Distress acknowledgement received FROM:002191000 VIEW ABORT 5. Press “2182”. 6. Lift handset. Press PTT and say: “MAYDAY, MAYDAY, MAYDAY This is MAYDAY This is Position: . What is wrong: . Kind of assistance: . Number of crew: . Other info: . OVER.” Quick DISTRESS Call 3 - 2 - 1 - RELEASE 1. If
2、off or STANDBY: press ON/OFF. 2. Open DISTRESS lid. 3. Press DISTRESS until RELEASE is displayed Then the undesignated distress call will be sent by default on the distress frequency 2187.5 kHz. Wait for answer! DISTRESS Acknowledgement 4. Press VIEW to read the contents of call. Release Press Press
3、 the DISTRESS button for 3 seconds to transmit TYPE: Distress MSG.: Undesignated Pos: Unknown Time: UnknownCANCEL Read call contents. CH FREQ MODE AM TELEPHONY SIGNAL POWER HIGH| | | | | DISTRESS Rx/Tx 2182.0kHz BAND Rx2182.0kHz Tx2182.0kHz CANCEL MODE SSB TELEPHONY TUNE Rx4357.0kHz Tx4065.0kHz Rece
4、ive frequency Transmit frequency CH TX MODE SSB TELEPHONY TUNE SIGNAL CLRF POWER HIGHSQUELCH ON| | | | | RF-G 5 Station Display Functions: Distress Telephony Frequencies To switch to Distress Frequency display: Press 2182 Distress Freq key. Distress Frequency Display Functions: Soft keys Selects the
5、 station and switches to Channel display for choice of channel number. Returns to Channel display without selecting the station. Selects previous station. Selects next station. Telex call code Name of station MMSI number of station SELECT CANCEL NAMELYNGBY CALL SIGNOXZ MMSI NO002191000 TELEX NO37383
6、 STN STATION TABLE CH FREQ MODE AM TELEPHONY SIGNALBAND POWER HIGHSQUELCH OFF| | | | | DISTRESS Rx/Tx2182.0kHz The frequencies for distress and safety telephony traffic are 2182 kHz, 4125 kHz, 6215 kHz, 8291 kHz, 12290 kHz, 16420 kHz Soft keys Switches to Channel display and previous channel number.
7、 Switches to Frequency display. Selects between AM and SSB mode of emission on 2182 kHz. Steps to the distress telephony frequency in the next higher band. Receive: Signal strength Mode of emissionTransmit: Output power level Output power setting Receive/transmit frequency. 6 Two-tone Alarm Signal T
8、o switch to the Two Tone Alarm Signal display: Press the Shift key followed by the Alarm key. Transmission of the two tone alarm signal will continue for 45 seconds, but may be stopped manually by pressing the STOP key in the frequency display. When the alarm signal ceases press the handset key and
9、transmit your distress message by speaking into the handset microphone with a clear and calm voice. Two-tone Alarm Display Functions: Listening for Calls Coast stations transmit traffic lists consisting of call signs/names of the ships for which they have traffic. The traffic lists are sent at speci
10、fied times and at intervals of typically two hours. They are broadcasted on the normal working frequencies of the coast stations. Ships should, as far as possible, listen to the traffic lists transmitted by relevant coast stations. On hearing their call sign they should establish communication as so
11、on as they can do so. 1.Select the appropriate station. 2.Select the channel on which traffic lists are transmitted. 3.Switch loudspeaker on and adjust volume to an appropriate level. If on HF, traffic lists are transmitted in more frequency bands simultaneously, search for the channel with the best
12、 propagation conditions. Making a Manual Call Wait until transmission of the traffic list has finished and the channel is free. Call the coast station on the working frequency on which the traffic list was received or as instructed by the coast station. 1.Hook off the handset. 2.Press the PTT key on
13、 the handset when speaking. Say: 1. 2. This is 3. Over 3.Release the PTT key to listen. 4.When answered: Follow the instructions from the coast station. The coast station may ask for further identification, information on position and next port of call, and may suggest another working channel for th
14、e traffic to follow. If the coast station is not ready to receive traffic immediately it may ask you to wait for a specific number of minutes. Note: The two tone alarm signal generator is intended for alerting ships not yet equipped with DSC equipment. It may be used only to announce a distress mess
15、age and primarily on the frequency 2182 kHz in AM telephony mode. Soft keys Returns to frequency display. Starts test of the alarm signal generator. Starts transmission of the two tone alarm signal. Press the START buttonFREQ TEST seconds to send alarm START 5 7 The button opens to the screen menu w
16、here all DSC calls are stored. In this menu NORMAL or DISTRESS calls, can be read separately and sorted by time. The button opens to the DSC transmitter menu. From here it is possible to make very easy calls (SHORE, SHIP) and more compli- cated calls including special category and tele commands. DSC
17、 Main Buttons To switch between the DSC STATUS and telephony displays: press TEL/DSC. The button opens the Address book menu. An addr book call is a complete DSC call added a name. It is possible to transmit, add or delete calls from here. The button switches between the DSC STATUS and telephony dis
18、plays. The MF/HF set is equipped with two receivers. One for watch on the distress frequencies and one for watch on the public DSC frequen- cies (calling watch). The calling watch receiver is identical with the receiver of the radio, and therefore it is possible to switch the calling watch on and of
19、f. The calling watch is only active in DSC mode, i e. calling watch is automatically switched off when switching to the TEL screen. But if calling watch is on and the user hooks on the handset, the control unit will automatically switch to the DSC status menu. Telephony Display LYNGBYFREQ STATION SS
20、B TELEPHONY SIGNAL POWER HIGHSQUELCH ON| | | | | CH4 1 8 CH Soft keys Changes calling watch frequencies. Switches between calling watch On/Off Views watch frequencies. Changes distress frequency used default for quick distress calls. DSC STATUS display DSC STATUS CHANGE WATCH Distress Watch: 2468121
21、6 MHz Calling Watch:22114- MHzVIEW FREQ Distress Frequency: 2187.5kHzDIST. FREQ 8 DSC Display Operation Receiving an Individual DSC Call When calling watch is on, your MF/HF set is constantly scanning the selected DSC channels for incoming DSC calls. Lift the handset and press PTT to connect to the
22、caller. OR Press VIEW to read out the call. Press ABORT to return to TEL screen. Press MORE to view the second part of call. Press CONNECT to transmit and set channel. Press CHANGE to change the acknowledgement. Take the handset and start talking. Press SEND to transmit the reply. Lift HANDSET to co
23、nnect Individual call received VIEW ABORT FROM:219000012 CALL CONTENT Time10:55:00 13 Okt 97 TYPE:Individual FROM:219000012 CAT.:Routine ACKN:RequestMORE Select CONNECTCONNECT to reply call COMM: SSB telephonyCHANGE MSG.:No Info AD.:Freq. RX 2053.0 TX 2053.0CANCEL AGAIN Select send to transmitSEND T
24、YPE:Individual TO:219000012 COMM: SSB telephony AD.:Freq. RX 2053.0 TX 2053.0 ACKN:ReplyCANCEL Rx2053.0kHz Tx2053.0kHz CH TX MODE SSB TELEPHONY TUNE SIGNAL CLRF POWER HIGHSQUELCH OFF| | | | | RF-G 9 Receiving DISTRESS Call When switched on, your MF/HF set is constantly scanning all DSC distress chan
25、nels for incoming DSC distress calls. If the ship in distress is within a reachable distance press “2182” and listen to the subsequent information. Press ACK/REPLY to send distress acknowledgement or distress relay. In these menus there is a security that makes it impossible to send an acknowledgeme
26、nt by mistake. Press SETUP to return to the TEL screen with the appropriate radio distress frequency, in this case 2182 kHz. Press AGAIN to view the first part of call. Press MORE to view the second part of call. Press VIEW to read out the call. Press ABORT to return to TEL screen Distress call rece
27、ivedVIEW ABORT FROM:21900100 CALL CONTENT Time:08:55:00 22 Sep 97 . TYPE:Distress FROM:219001000 MSG.:Fire Received on 2187.5 kHzMORE CALL CONTENTACK/REPLY SET UP N: 5701 E:00952 Time09:58 UTCCANCEL COMM: SSB Telephony AGAIN DISTRESS Rx/Tx2182.0kHz AM TELEPHONYSIGNAL POWER HIGH SQUELCH OFF| | | | |
28、CH FREQ MODE BAND 10 Calling a SHIP Press Tx CALL You first see the messages “Call in progress” and then “Waiting for acknowledgement” Wait for answer If the ship answers see page 8 Receiving an Individual DSC Call. Key in the nine digit MMSI number of the wanted ship. The current telephony frequenc
29、y is included in the call, and this frequency is used as working frequency for the following radio communication. Select a SHIP call. Accept the number. A sub menu where a pre-programmed ship can be selected. Select the frequency on which the call is transmitted. Select SEND to transmit the call. Se
30、lect type of call: SHORE SHIP DISTRESS MORE Key in the shipACCEPT MMSI number MEMORY TYPE:Individual TO:210215456CANCEL Select DSC frequencyACCEPT CANCEL Rx 2177.0kHz Tx 2177.0kHz Select send to transmitSEND TYPE:Individual TO:210215456 COMM: SSB telephony AD.:Freq. RX 2053.0 TX 2053.0 ACKN:RequestC
31、ANCEL 11 Calling a SHORE Station Press Tx CALL You first see the messages “Call in progress” and then “Waiting for acknowledgment” Wait for answer If the coast station answers see page 8 Receiving an Individual DSC call. If the SHORE station supports the possibility of including a telephone number,
32、the telephone number can be keyed in followed by ACCEPT. Key in the nine digit MMSI number of the wanted coast station. Select a SHORE call. Accept the number. A sub menu where a preprogrammed station can be selected. Select ACCEPT to make a call directly to the shore station and talk with a person
33、there if no phone number is keyed in. Select TEST CALL to make a test call to the coast station. Select the frequency on which the call is transmit- ted. Select SEND to transmit the call. Select type of call: SHORE SHIP DISTRESS MORE Key in the coastACCEPT station MMSI number MEMORY TYPE:Individual
34、TO:002191000CANCEL Key in theACCEPT phone number TYPE:IndividualTEST CALL TO:LYNGBY _CANCEL Select DSC frequencyACCEPT CANCEL Rx 8049.0kHz Tx 8049.0kHz Select send to transmitSEND TYPE:Individual TO:LYNGBY AD.:No info ACKN:RequestCANCEL Note that when calling a coast station, it is always the coast
35、status that selects the working frequency for the following communication. 12 Address Book This MF/HF set is designed with self-explaining menus. The four soft keys on the right side of the display refer to the display text. Open the addr book menu. One step back. Go to the first screen on the same
36、subject. Select ADD to make a new call ADD DELETE CANCEL AGAIN Accepts the data. Go to the next screen on the same subject. Lower left side of the display is the data area. Right side shows the function of the soft keys. Upper left side of the display is used for text instructions Use , or keyboardA
37、CCEPT to search in addr book Ms SunriseNAME TO:219222222 MSG :No infoMORE 13 Using Two Control Units You can connect two control units to the system. However, it can only be controlled by one control unit at a time. Priority of Control Unit #1 Control unit #1 has the highest priority, i.e. you can a
38、lways control the system by means of control unit #1 even if control unit #2 has initiated a distress call. Control Unit #2 Taking Over the Control When control unit #1 is in the DSC Status Menu, control unit #2 can take over the control of the system by leaving the DSC Status Menu. When control uni
39、t #2 returns to the DSC Status Menu, the control is automatically given back to control unit #1. Status Indication Control Unit #1: When control unit #2 controls the system, the display of control unit #1 shows what activity is taking place. The following read-outs may appear: ”OCC by unit 2 sending
40、 Distress alert” means that control unit #2 is transmitting a distress call, or awaiting automatic retransmission. “OCC by unit 2 sending DSC call” means that control unit #2 is transmitting an ordinary DSC call. “OCC by unit 2 using DSC functions” means that control unit #2 is in a DSC menu without
41、 transmitting a call. “OCC by unit 2 using Radio functions” means that control unit #2 is not in a DSC menu. Control Unit #2: The display of control unit #2 always shows when the system is busy. When the system is not busy, the display shows the DSC Status Menu. If control unit #2 tries to take over
42、 the control, but is not allowed to do so, this is indicated by both a sound and the display read-out “OCC by unit 1”. Responding to Incoming DSC Calls When a call comes in, only the active control unit i.e. the one that controls the system at the moment is to respond. If for instance control unit #
43、2 has sent an individual DSC call, control unit #2 is to receive and respond to the acknowledgement call that may follow. If a call comes in when both control units are in the DSC Status Menu, and therefore not active, both control units are to receive and respond to the call. Power On/Off By Contro
44、l Unit #2 Power On You can turn on the whole system by means of control unit #2. If the display shows the words “Unit switched off”, and the on/off button is pressed, what happens depends on whether or not control unit #1 is controlling the system at the moment: a)If control unit #1 is controlling t
45、he system, this will be indicated by the display of control unit #2. b)If control unit #1 is not controlling the system, control unit #2 will start up in the DSC Status Menu. When the whole system is off, it makes no difference which control unit turns it on. Power Off You cannot turn off the whole
46、system by means of control unit #2. When you press the on/off button, only control unit #2 is turned off. The display will then show the words “Unit switched off”. Interconnecting When you have received a DSC call, including working frequency, it is possible to transfer the system control from contr
47、ol unit #1 to control unit #2. To do so, in the Frequency menu, key: “Shift” + “INT- C/InterCom”. When a DSC call is transferred from control unit #1 to control unit #2, the right working frequencies are maintained. If the handset of control unit #2 is not lifted within five minutes, the control aut
48、omatically returns to control unit #1. DSC Scanning Frequencies You cannot change the DSC scanning frequencies by means of control unit #2. The scanning frequencies used when in the DSC Status Menu of control unit #2 are the same as if in the DSC Status Menu of control unit #1. If control unit #1 ch
49、anges the DSC scanning frequencies, that information is passed on to control unit #2. Therefore, if control unit #2 is given the control, and starts scanning, the same scanning frequencies are used. 14 Advanced DSC Calls Extended DSC calls make it possible for you to control the call completely within the international rules, including the possibility of sending data or fax from optional equipment connected to your MF/ HF set. To start an extended call, select EXTENDED as the Type of call in the Tx menu below, and then continue in the Exte