Uniden_UBC-9000XLT_user.pdf

上传人:cc518 文档编号:199009 上传时间:2025-03-08 格式:PDF 页数:58 大小:10.86MB
下载 相关 举报
Uniden_UBC-9000XLT_user.pdf_第1页
第1页 / 共58页
Uniden_UBC-9000XLT_user.pdf_第2页
第2页 / 共58页
Uniden_UBC-9000XLT_user.pdf_第3页
第3页 / 共58页
亲,该文档总共58页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Uniden_UBC-9000XLT_user.pdf》由会员分享,可在线阅读,更多相关《Uniden_UBC-9000XLT_user.pdf(58页珍藏版)》请在收音机爱好者资料库上搜索。

1、-= :- _. -. UBC9000XL T AutoScanner I 1 11 1:1 UBZZO1248AZ OPERATING GUIDE :Ill T j .r- . - - UBC9000XL T Controls 1234 IfEE II1Iden:a;t-U8CeoooXLT JII!Ii! I.IHI.jJS I I J r 1098765 .1: 1. Programmingand Status Keys 6. Numericand Special Function 2. Display Keys 3. Bank Keys 7. Scan Keys 4.ON/OFFNOL

2、UME and 8. Mode Keys SQUELCH Controls9. Search Keys 5. RotaryTuning Controls 10. Output Jacks. - -1 Precautions Before you use this scanner, please read and observe .the following: WARNING! Unidendoes not representthis unitto be waterproof. To reduce the risk of fire or electrical shock, do not expo

3、se this unitto rain or moisture. Unidenand Bearcat are registeredtrademarksof Uniden Corporation 1995 Uniden Corporation.All rights reserved.Printed in the Philippines - Table of Contents Introduction2 Included with the UBC9000XLT3 Feature Highlights. . . . . . . . .4 Getting Started. . . . . . . .

4、. . .6 Base Installation. . . . . . . . .6 Whatis Scanning? . . . . . . .7 Searching7 Banks and Channels. . . . . . .8 Settingthe Squelch. . . . . . . .8 Usingthe RotaryTuner. . . .10 Programming Channels. .11 ProgrammingBy ManuaIEntry12 Programmingwiththe RotaryTuner13 ProgrammingwithSearch.14 Prog

5、rammingwith AUTOSTORE17 Deletinga Programmed Frequency. . .19 Transferring a Programmed Frequency. .19 Programming Channels with AlphaCharacters. . . . . . .20 To DeleteAlphaCharacters.22 The Scan Mode24 Scanning AllProgrammed Channels and Banks. . . . . .24 TurningBanks ONor OFF.25 LockingOut Chann

6、els. . . .26 UsingPriorityScan. . . . . . .28 The Search Mode. . . . . . . . . 29 Beginninga Search. . . . .29 ScrollingFrequencies Duringa Search. . . . . . . . .30 UsingTurboSearch. . . . . . 31 UsingSearchDelay. . . . . . 31 LockingOutFrequencies. 32 Unlocking a Frequency. . . 32 Unlocking AllFre

7、quencies. 33 - :=:= Birdies33 Additional Scanner Features34 Using DataSkip34 Changingthe FrequencyStep. . . . . . . . . .35 Settingthe Signal Mode. . .36 UsingSignalAttenuation. . . 37 Preventing Accidental Programming. . . 38 UsingCOUNTto MonitorChannel Activity. . .38 DisplayingBank MemoryStatus.

8、. . . . . . . . .40 UsingAuto Recording. . . . .41 ViewingScanner Status Information. . . . . . . .42 DisplayLight44 UsingHi-Cut44 CTCSSOperation. . . .45 Installingthe CTCSS Board.45 UsingCTCSS.47 To Changethe CTCSSTone Frequency.48 CTCSSTone Frequencies.49 Careand Maintenance.50 Troubleshooting.51

9、 OptionalAccessories and ReplacementParts. . . . . 52 Specifications. . . . . . 53 1 ! 1 I 1 .- Introduction The UBC9000XLT isa sophisticatedinformation radiowith automatic scanning capabilities. You can use it at homeas a base unit,or install in your vehicle as a mobile unit. The UBC9000XLT can sto

10、re frequencies such as, police, fire/emergency, marine, air, weather, and other broadcasts into20 banks of 25 channels each. The new RotaryTuner featureenables rapidand easy selectionof channels and frequencies. And with AUTO STORE,you can automatically program any channel. With the UBC9000XLT, you

11、can scan all 500 channelswith Turbo Scan. In the Search Mode,you can choose super fast Turbo Search. Inaddition, the UBC9000XLT has AUTO SORT-an automaticfrequency sorting feature for faster scanningwithin each bank. Types of Communication You will be able to monitor communicationsuch as: .Police an

12、d fire department(including paramedics) , .Business/industrialradio .Motion pictureand press relay . Utility .Landtransportation frequencies, such as truckingfirms, buses, taxis, tow trucks, and railroads .Marine and amateur (ham radio) bands .Air band .Analogue cellular telephone frequencies .Publi

13、c Service800 MHz band And manymore in the 25-1300 MHz range. 2 L-.- .- 1_- Included with the UBC9000XL T I !1 , TelescopingAntenna (AT124) Australian Warranty Program AC Adaptor (AAD8500U) .Readthis Operating Guide thoroughly beforeyou use the scanner. .If any of the above items are missing or damag

14、ed,contact the place of purchase immediately. - 3 Feature Highlights .TwinTurboScan/Search-This lightning-fasttechnology enablesthe UBC9000XLT to scan upto 100channels per second and search upto 300 steps per second (in5kHz steps). Becausethe frequency coverage is so large (see Specifications,page 5

15、3, for band listing), a very fast scanning system is essential. That is why we combined our latest technology-Turbo Scan and Search - into the UBC9000XLT. .RotaryTunerControl-TurnthelargeRotaryTunerto select the desiredfrequency or channel. .500Channels- You can programeach of these memory channelst

16、o store one frequency. .20 Banks - Each bankcontains 25 channels, useful for storing similar frequenciesin order to maintain faster scanning cycles. .25-1300MHz-lndicatesthe rangeof frequenciesthat can be searched within the bands of your scanner. (Note: The frequency coverage is not totallycontinuo

17、us between 550-760 MHz.) .10Priority Channels-You can assign one Prioritychannel for each of the 10 banks,A-J. This allowsyou to keeptrack of activity on your most importantchannel(s) while monitoring other channelsfor transmissions. .Auto Store-Automaticallystores all active frequencies within the

18、specified bank(s). .Auto Sorting- Programmedfrequenciesare automatically sortedwithin each bank for faster scanning. .Auto Recording-This feature lets you recordchannel activity from the scanner onto a tape recorder. .Scan/Search Delay-Inthe Scan or Search Mode,causes the scannerto remain on a frequ

19、ency two seconds after the last transmissionto wait for a possible reply. .DirectChannelAccess-Allowsyou to manuallyselecta specific channel without scanning. .Direct Frequency Programming-Allowsyou to programa specific frequency into a channel without searching. .Frequency Transfer-Letsyou transfer

20、 a frequency intoan empty channel, or replacethe frequency in the current channel. .Programmable Alpha Characters-Youcan program upto 250 channels with 16alphacharactersfor easy reference. 4. r f .- .Variable FrequencySteps(Increments)-Inthe search or ManualMode, lets you change the steps betweenfre

21、quencies. .Channel/FrequencyLockout-Letsyou temporarily remove channels or frequencies from the scanningor search cycle. .Signal Attenuation-Reducesthe scanners sensitivityfor unusuallystrong signals often found on the WFM (wide frequency modulation) bands. .Data Skip-Letsyou set the scannerto autom

22、aticallycontinue searching or scanningwhen it encountersan unmodulatedor data signal. .Enter Lock-Temporarilydisables programming keysto prevent accidental programming. .External Speaker Jack-Allowyou to connect an external speakeror earphone for custom listening.See Includedwith your Scanneron page

23、 3, and OptionalAccessories CHANNELS1 2 3 4 5 6 7 a 9 10 I FrequencyFrequency LockedOutNot (UO)Entered An optional DELAYcan be set so that the scanner stays on the channel for 2 more seconds,waiting for anothertransmission before resuming scanning. Searching Scanning and searching aresimilar inthat

24、they both involvefinding active frequencies within a group of frequencies.The difference is Scanning looks only at a group of programmedfrequencies that are stored in the scanners channels and grouped into banks. Searching looks at all the frequencies within a pre-selected range of frequencies. If y

25、ou find an interestingfrequency while searching,you can store it in a channel for easier access later. See Programmingwith Search on page 14. Themainpurpose of the Search function is tohelp you find active frequencies toprogram into memory. 7 :=- C eo. r I .- , t . ,.-.-.-.-.-. .-=:-. :t CTCSSOperat

26、ion This section applies only if you are installingand using an optional CTCSS Tone Board with your scanner. Installing the CTCSS Board InstallingtheCTCSSToneBoardisa simpleprocedure, andrequires only afewminutesfollowingthestepsbelow. CAUTION:Be sure to turn the scanner off and disconnect the power

27、 cord before attempting to open the scanner. I 1. Remove the five screws from the top cover. Lift .GUJ4) :elf- :amf) 6m :5 . Strong Signals . . . MediumSignals . ,. Weak Signals -.-.-. - -.-.-.-.-.-. Noise-.-.-. -.-. -.-.-.-.-.-. . r Using the Rotary Tuner Frequency LED Channel LED Mode Selector Rot

28、ary Tuner Lock LED Lock Key RotaryTuner and Controls This uniquefeature allows easy, rapid,and preciseselection of frequencies and channels in the UBC9000XLT. Frequency/Channel Mode Selector-Pressto switch betweenchannel or frequency mode. When the CHANLED is on, you can step rapidly through channel

29、s with the RotaryTuner. When the FREQ LED is on, you can tune quickly and accuratelythrough frequencies with the RotaryTuner. Rotary Tuner-Usethe RotaryTuner to step through channels or frequencies, depending onthe setting ofthe Frequency/ChannelMode Selector. Turn the knobclockwiseto step up,counte

30、r clockwiseto step down. LockKey/LED-The LED lightswhen the RotaryTuner is locked. Press LOCK to enable the RotaryTuner. - 10 - Programming Channels Before you can scan, you must program the channels within a bank. You can store one frequency per channel, up to 500 channels. These are the banks and

31、their associated channels: Eachtime you store a frequency, the list of scanningfrequencies in the bank is automaticallysorted byfrequency number. This uniqueAuto Sort feature enablesfaster scanning. When you manuallystep through.a bank, however,frequencies are sortedaccording to channel number. Choo

32、sing a Programming Method WiththeUBC9000XL T,therearefivewaystoprogramachannel: .Manuallyselecting a channel and frequency, using the numeric keypad .Usingthe RotaryTuner to select a channel and frequency .Searching a bandto find active frequencies,and then storingthem into channels .Usingthe Auto S

33、tore feature to automatically programchannels .Transfer a programmedfrequency from another channel 11 =- H :Ii BankChannel NumberBankChannel Number A1-251251-275 B26 -502276 -300 C51 -753301-325 I D76 - 1004326 - 350 E101 - 1255351 - 375 F126 - 1506376-400 G151 -1757401 - 425 H176 -2008426 -450 I201

34、 -2259451-475 J226 -2500476 -500 Auto Sort Programming By Manual Entry Usethese keys: I81Idenp.IJI!CT D CLJ m:JL) CD ID (E IJ CL .-. .- JJfl) EJEl8 C (PROGIlSENOIIAlPHA) c:sDATA uoJCJ c:(DB.AY.)c:3 Scan and NumericKeys 1. Select a frequency. Example: Program 482.7625MHzinto Channel1. 2. PressIMANUAL

35、)to enter the ManualMode. BankAch22 LlOOOO.OOOOMHz 3. Enterthe channel number, then pressI MANUAL).Bank AP ch1 LlOOOO.OOOOMHz 4.Enterthe frequency. Then press. Example: 482.7625 Ifyou makea mistake, press twice to erase. BankAP ch1 482.7625MHz 12 - .- If an error is madeduring programming,or if the

36、frequency is out of range,this screen appears. Enter a valid channel or frequency number. Ifthe frequency is stored in another channel, the display will indicatethe originalchannel for that frequency. Bank AP ch OUTOFBAND BankAch1 DUPLICATECH230 To program morechannels, repeatsteps 3 and 4. Pressto

37、store the samefrequency intothe selected channel. Or, select another channel. Or, presstwice to clear. Programming With the Rotary Tuner Usethesecontrols: 88n ( PROG11SENO 11AlPHA )-J 0CTCSSDATA uoc:) c:!) c:)(DELAY.)c:3 D II1IdI!napuse-.T rrr. Scan, Numeric Keys, and Rotary Tuning Controls 1. Press

38、IMANUAL)to enter the Manual Mode. OR Turn the Rotary Tuner. Note:Make sure the LOCK LED is out. 2. Select CHAN with the RotaryTuner Mode Selector,then turn knob. Example:channel52 Turn rightto step up through channels, leftto step down through channels. 13 -:J -=- Bank Bch49 LlOOOO.OOOOMHz Bank Cch5

39、2 LlOOOO.OOOOMHz : 1 r I f .- 3. Select a frequency. Example: 123.7750 4. Enterthe Frequency. Then press. BankCch52 123.7750MHz 5. Toturnto a newfrequency, select FREQwiththe RotaryTuner ModeSelector then turn rightto step up, leftto step down. Example: 123.7875 (turn right) 12.5KHzch :?2 AM123.7875

40、IvrHl- Note: The channel indicatorflashes onthe display,indicatingthat the frequencydisplayed is not programmedinthat channel. 6. Pressto programthe channel.BankCch52 123.7875MHz To program more channels with the Rotary Tuner, repeat steps 2-6. Programming with Search The Search feature lets you sea

41、rch for active frequencies in a range you choose and store any or all of those frequencies into channels. For more information about searching, see The Search Mode, page 29. Use these keys: miii! - 8 CJ ( PROG 11SENO11ALPHA). . Search, Scan, Numeric,and Bank Keys, and RotaryTuningControls Note: Be s

42、ure to set SQUELCH before you begin a search.See Setting the Squelch, page 8. 14 .- -.-. - -. r 1. Select a frequency range. See page 53. Example:450.000MHzto 456.000 MHz 2.PressIMANUAL). 3. Enter the frequency and press toenter the lower limit of the search range. Example: 450.000 MHz 4. Enter the

43、frequency and press toenter the upper limit of the search range. Example: 456.000 MHz 5. Pressto beginthe search function. Toexitsearch,pressI MANUAL). The scanner stops on the first active frequency it finds. INFM450o0000MHZ! NFM 450.0000MHz NFM 456.0000MHz I SRC NFM 12 .5 KHz t450.3750MHz SRC NFM

44、12 .5 KHz t450.3750MHz .To program the frequency, pressto stop searchin-g.Then, proceed to step 6a, 6b, or 6c. .If you do not wantto programthe frequency, pressto continue searching. 6a.Programthe frequency into the current channel. Press. 6b. Program the frequency into another channel: 12.5KHzch- N

45、FM 450.3875MHz Bank Cch53 450.387SMHz 12. 5KHzch5 NFM 450.3875MHz 15 :; t 1.PressISEIOIto enter the Transfer Mode. 2.Enterthe channel number. Example: Channel200. 3.Press. 4.Pressto Program the frequency. Enter Bankor ch 450.3875MHz I 200 450.3875MHz Bank Hch200 OOO.OOOOMHz 0(Displayflip-flops) I450

46、.3875MHzI Bank Hch200 450.3875MHz 6c. Programthefrequencyintothefirstopenchannelof anotherbank. 1.PressISEIOIto enter the Transfer Mode. 2.Choose a bank. Example: Press C. Note: Press EJand bank(0-9)key to choose a bank 0 through 9. 3.Press. 12.5KHzch- NFM 450.3875MHz Enter Bank or ch 450.3875MHz Ba

47、nkIPch201 450.3875MHz 16 j r- Programming WithAUTO STORE This procedure searches a frequency rangeand automaticallystores activerequencies into empty channelsof the selected bank(s). Note: Be sure to set SQUELCH beforeyou begin a search. See Setting the Squelch on page 8. Usethese keys: LHEXTSI : .

48、l7$. YO Programming,Search, Scan, Mode, Numeric,and Bank Keys and RotaryTuning Controls 1. Select a frequency range. See page 53. Example:810.000 MHz to 856.000 MHz 2.PressI MANUAL). 3. Enter the frequency and press toenter the lower limit of the search range. Example: 810.000 MHz NFM 456.0000MHz NFM 810.0000MHz 4. Enter the frequency and press to enter the upper limit of the search range. Example: 856.000 MHz NFM 810.0000MHz NFM 856.0000MHz 17 ,J: =-. - 1 I . t .- 5. Press AUTOI toenter the Auto Store Mode. 6.Select the bank(s) for programming. The select

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 火腿一族 > Receiver

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号