1、Specification. 2 Exploded View U00230001). 2. Remove the SPECIAL SCREW (A) and ENCODER KNOB (B). 3. Remove the MIC/SP CAP (C) and RING NUT (D). 4. Remove the two screws (E). 5. Turn the M2.6x30 screw several times to affix the screw to the bottom right corner. 6. Press the top of the screw toward to

2、 a panel top to remove the rear case Assy from the front panel. Removing the Rear Case Assy screw M2.6X30(A) (B) (C) (D) (E) (E) RA1012900 SHEET (MIC) M4090189 SPEAKER(0.5W/16-ohm) RA105780A FRONT CASE (W/ SP NET, WINDOW) RA1016400 LIGHT GUIDE (LED) RA1016600 HOLDER (ANT) RA101670B (x2 pcs) SUPPORT

3、(ACS) RA1016900 SUPPORT (PTT) RA1016800 SUPPORT (POW) RA1017100 PROTECTOR (L) RA1014200 SHEET HOLDER (MIC) RA1017000 PROTECTOR (R) RA1049000 ENCODER KNOB (2PRY) CP9295001 CHASSIS ASSY (w/ PACKING PAD, O RING, SMA CONNECTOR) RA1093500 MYLAR SHEET (ANT) RA1092400 SHEET (SW) RA107300A SPACER (PTT) RA10

4、70500 LIGHT SHEET (LCD) RA106950A SHEET (ACS) RA1061400 O RING (12.5X1) RA1066900 BLIND SHEET RA0337300 SHEET (C012) RA0603200 O RING (0.7X3.7) RA1042800 RING NUT (WITCO) RA060450B SPECIAL NUT (M) RA0918600 SPECIAL SCREW (2.6X5X8) RA1053700 (x3 pcs) COIL SPRING RA1011800 (x2 pcs) STUD RA1057200 DOUB

5、LE FACE (PAD-R) RA1057100 DOUBLE FACE (PAD-L) RA1017600 SHEET (LED) RA1017500 SHEET (WIN) RA1013900 DOUBLE FACE (ANT-A) RA101370B SP HOLDER RA0603600 O RING (1X4.2) RA1037500 O RING (6.5X2) RA1013300 RUBBER PACKING (LED) RA1013500 RUBBER PACKING (ANT) RA101340B RUBBER PACKING (SP) RA101320A RUBBER K

6、EY (PTT) RA101250A KEY PAD RA1017200 CAP (TOP) RA1017300 CAP (SIDE) RA1012700 GASKET RA101300B (x2 pcs) RUBBER KEY (ACS) RA101310A RUBBER KEY (POW) RA1016500 LCD HOLDER RA1013800 SHEET (LCD) RA1017400 (x2 pcs) DOUBLE FACE (LCD) RA1080500 SHIELD SHEET Q7000614 LCD MODULE MAIN VCO Unit SUB VCO Unit CO

7、NNECTOR Unit CNTL Unit Q9000881 BAR ANTENNA P0091520 CONNECTOR FR018900A MIC-CONNECTOR Flat Cable RF Unit RA1054200 CAP (BATT) RA1053600 BELT CLIP AAG10X001 FNB-101LI RA1007400 (x2 pcs) SHIELD CASE VCO RA0951900 NAME PLATE (YAESU) Q3000183 Q3000185 Q9500149 Q9500150 RUBBER ANTENNA YHA-64 RUBBER ANTE

8、NNA YHA-65 (USA) AC-DC ADAPTOR NC-86B (USA) AC-DC ADAPTOR NC-86C (EXP) U9900240 U9900239 U9900241 U07230102 U24310020 U9900242 U9900243 U9900181 PAN HEAD TAPTITE-B 1.4X3NI #3 PAN HEAD TAPTITE-B 2X3NI #3 PAN HEAD TAPTITE-B 2X10SUS #3 PAN HEAD SCREW M2X3NI #1 BIND HEAD TAPTITE-B M3X10SUS TAPPING SCREW

9、 2X2.5NI TAPPING SCREW M2X3NI TAPTITE SCREW 2X3.5(CAP) 2 11 2 1 2 4 2 1 RA1092400 (x2 pcs) SHEET (SW) FR018660A ANT Flat Cable CP9296002 (USA) CP9296003 (EXP) CP9296004 (EU) CP9296005 (AUS) FRONT CASE ASSY 5VX-8R/E and VX-8DR/E Technical Supplement Block Diagram 6VX-8R/E and VX-8DR/E Technical Suppl

10、ement Block Diagram Note 7VX-8R/E and VX-8DR/E Technical Supplement Alignment Introduction and Precautions The and has been carefully aligned at the factory for the specified performance across the specified amateur bands. Realignment should therefore not be necessary except in the event of a compon

11、ent fail- ure. All component replacement and service should be performed only by an authorized VERTEX STANDARD representative, or the warranty policy may be voided. The following procedures cover the sometimes critical and tedious adjustments that are not normally required once the transceiver has l

12、eft the factory. However, if dam- age occurs and some parts are replaced, realignment may be required. If a sudden problem occurs during normal operation, it is likely due to component failure; realign- ment should not be done until after the faulty compo- nent has been replaced. We recommend that s

13、ervicing be performed only by authorized VERTEX STANDARD service technicians, who are experienced with the circuitry and fully equipped for repair and alignment. Therefore, if a fault is suspected, contact the dealer from whom the trans- ceiver was purchased for instructions regarding repair. Author

14、ized VERTEX STANDARD service technicians realign all circuits and make complete performance checks to ensure compliance with factory specifications after replacing any faulty components. Those who do undertake any of the following align- ments are cautioned to proceed at their own risk. Prob- lems c

15、aused by unauthorized attempts at realignment are not covered by the warranty policy. Also, VERTEX STANDARD must reserve the right to change circuits and alignment procedures in the interest of improved performance, without notifying owners. Under no circumstances should any alignment be at- tempted

16、 unless the normal function and operation of the transceiver are clearly understood, the cause of the mal- function has been clearly pinpointed and any faulty com- ponents replaced, and the need for realignment deter- mined to be absolutely necessary. Required Test Equipment H RF Signal Generator wi

17、th calibrated output level at 500 MHz H Deviation Meter (linear detector) H In-line Wattmeter with 5% accuracy at 500 MHz H 50-ohm, 10-W RF Dummy Load H 8-ohm AF Dummy Load H Regulated DC Power Supply adjustable from 8 to 16 V DC, 3A H Frequency Counter: 0.2-ppm accuracy at 500 MHz H AF Signal Gener

18、ator H AC Voltmeter H DC Voltmeter: high impedance H UHF Sampling Coupler H SINAD Meter Alignment Preparation & Precautions A 10-W RF dummy load and in-line wattmeter must be connected to the main antenna jack in all procedures that call for transmission, alignment is not possible with an antenna. A

19、fter completing one step, read the next step to see if the same test equipment is required. If not, re- move the test equipment (except dummy load and watt- meter, if connected) before proceeding. Correct alignment requires that the ambient tempera- ture be the same as that of the transceiver and te

20、st equip- ment, and that this temperature be held constant between 6886F (2030C). When the transceiver is brought into the shop from hot or cold air, it should be allowed some time to come to room temperature before alignment. Whenever possible, alignments should be made with os- cillator shields an

21、d circuit boards firmly affixed in place. Also, the test equipment must be thoroughly warmed up before beginning. Note: Signal levels in dB referred to in the alignment proce- dure are based on 0 dB=0.5 V (closed circuit). 8VX-8R/E and VX-8DR/E Technical Supplement Alignment Internal System Alignmen

22、t Routine This uses a programmed routine in the transceiver which simplifies many previously complex discrete com- ponent settings and adjustments with digitally-con- trolled settings via front panel buttons and LCD indica- tions. 1. To begin, set the transceiver to the VFO mode on the A-Band in the

23、 Mono band mode. 2. Program a password for the Alignment (AH029M) ac- cording to the following procedure: 1) Press and hold the MENU key for one second to enter the Set mode. 2) Rotate the DIAL knob to select Set Mode Item 21: CW ID. 3) Press the MENU key briefly to enable adjustment of this Set Mod

24、e Item. 4) Rotate the DIAL knob to select ON. 5) Press the MODE key, then press and hold in the HM/RV key for two seconds to clear any previous entry. 6) Program the password AH029M using the DIAL knob (select the character), and BAND/MODE key (move the cursor). 7) When you have completed the passwo

25、rd, press the MENU key briefly, then press the PTT switch to exit to normal operation. Remember to delete the password AH029Mfrom the Set Mode Item 21: CW ID when the alignment adjust- ments are finished by pressing and holding in the HM/ RV key for two seconds (as in step 5 above). 3. Press the PWR

26、 switch for two seconds to turn the transceiver off. 4. Press and hold in the HM/RV key while powering the transceiver on again. The transceiver will enter the adjustment mode, and the display will show the first alignment setting. Thereafter, the frequencies used during alignment will automatically

27、 be set without action by the technician. DIAL V/M V/M HM/RV As each transceiver is individually optimized at the factory, the precise settings for the transceiver on your bench may be slightly different. PLL Reference Frequency Adjustment (PLL REF) Connect the test equipment as shown in Figure 1: T

28、X Alignment Setup. Rotate the DIAL knob to select the Alignment Menu PLL REF. Press the V/M button (the ? icon will appear on the display). Press the PTT switch to transmit and rotate the DIAL knob so that the frequency counter setting is 440.000 MHz (100 Hz). Release the PTT switch, then press the

29、V/M button (the ? icon will disappear from the display). Figure 1: TX Alignment Setup Figure 2: RX Alignment Setup Wattmeter In-Line Dummy Load 50-ohm RF Coupler Sampling Meter Deviation Counter Frequency Generator RF Signal Meter SINAD AF Load 8-ohm 9VX-8R/E and VX-8DR/E Technical Supplement Alignm

30、ent A-Band 430 MHz Band Adjustment Receiver Sensitivity Adjustment (TUNE DC) Connect the test equipment as shown in Figure 2: RX Alignment Setup. Rotate the DIAL knob to select the Alignment Menu TUNE DC. Set the RF Signal Generator output to 435.100 MHz, at a level of -10 dB, 3.5 kHz deviation with

31、 a 1 kHz audio tone. Press the V/M button (the ? icon will appear on the display). Rotate the DIAL knob for maximum deflection on the SINAD meter. Press the V/M button (the ? icon will disappear on the display). Squelch Hysteresis Confirmation (HIS SQL) Rotate the DIAL knob to select the Alignment M

32、enu HIS SQL. Confirm that the alignment value is 0. Squelch Threshold Adjustment (THLD SQL) Connect the test equipment as shown in Figure 2: RX Alignment Setup. Rotate the DIAL knob to select the Alignment Menu THLD SQL. Set the RF Signal Generator output to 435.100 MHz, at a level of -12 dB, 3.5 kH

33、z deviation with a 1 kHz audio tone. Press the V/M button (the ? icon will appear on the display). Press the F/W key two times to store the FM SMeter Full Scale level. Press the V/M button (the ? icon will disappear on the display). Tight Squelch Adjustment (TIGH SQL) Connect the test equipment as s

34、hown in Figure 2: RX Alignment Setup. Rotate the DIAL knob to select the Alignment Menu TIGH SQL. Set the RF Signal Generator output to 435.100 MHz, at a level of +4 dB, 3.5 kHz deviation with a 1 kHz audio tone. Press the V/M button (the ? icon will appear on the display). Press the F/W key two tim

35、es to store the FM SMeter Full Scale level. Press the V/M button (the ? icon will disappear on the display). FM S-Meter S-1 Adjustment (S1 LEVEL) Connect the test equipment as shown in Figure 2: RX Alignment Setup. Rotate the DIAL knob to select the Alignment Menu S1 LEVEL with NFM icon. Set the RF

36、Signal Generator output to 435.100 MHz, at a level of -7 dB, 3.5 kHz deviation with a 1 kHz au- dio tone. Press the V/M button (the ? icon will appear on the display). Press the F/W key two times to store the FM SMeter Full Scale level. Press the V/M button (the ? icon will disappear on the display)

37、. FM S-Meter Full-Scale Adjustment (S9 LEVEL) Connect the test equipment as shown in Figure 2: RX Alignment Setup. Rotate the DIAL knob to select the Alignment Menu S9 LEVEL with NFM icon. Set the RF Signal Generator output to 435.100 MHz, at a level of +20 dB, 3.5 kHz deviation with a 1 kHz audio t

38、one. Press the V/M button (the ? icon will appear on the display). Press the F/W key two times to store the FM SMeter Full Scale level. Press the V/M button (the ? icon will disappear on the display). Wide FM S-Meter S-1 Adjustment (S1 LEVEL) Connect the test equipment as shown in Figure 2: RX Align

39、ment Setup. Rotate the DIAL knob to select the Alignment Menu S1 LEVEL with WFM icon. Set the RF Signal Generator output to 435.100 MHz, at a level of 0 dB, 20 kHz deviation with a 1 kHz audio tone. Press the V/M button (the ? icon will appear on the display). Press the F/W key two times to store th

40、e FM SMeter Full Scale level. Press the V/M button (the ? icon will disappear on the display). 10VX-8R/E and VX-8DR/E Technical Supplement Alignment Wide FM S-Meter Full-Scale Adjustment (S9 LEVEL) Connect the test equipment as shown in Figure 2: RX Alignment Setup. Rotate the DIAL knob to select th

41、e Alignment Menu S9 LEVEL with WFM icon. Set the RF Signal Generator output to 435.100 MHz, at a level of +20 dB, 20 kHz deviation with a 1 kHz audio tone. Press the V/M button (the ? icon will appear on the display). Press the F/W key two times to store the FM SMeter Full Scale level. Press the V/M

42、 button (the ? icon will disappear on the display). TX Power (HI) Adjustment (HI POWER) Connect the test equipment as shown in Figure 1: TX Alignment Setup. Rotate the DIAL knob to select the Alignment Menu HI POWER. Press the V/M button (the ? icon will appear on the display). Press the PTT switch

43、to transmit and rotate the DIAL knob so that the Power Meter reading is 5.0 W (0.1 W). Release the PTT switch, and then press the V/M but- ton (the ? icon will disappear on the display). TX Power (L3) Adjustment (L3 POWER) Connect the test equipment as shown in Figure 1: TX Alignment Setup. Rotate t

44、he DIAL knob to select the Alignment Menu L3 POWER. Press the V/M button (the ? icon will appear on the display). Press the PTT switch to transmit and rotate the DIAL knob so that the Power Meter setting is 2.5 W (0.1 W). Release the PTT switch, and then press the V/M but- ton (the ? icon will disap

45、pear on the display). TX Power (L2) Adjustment (L2 POWER) Connect the test equipment as shown in Figure 1: TX Alignment Setup. Rotate the DIAL knob to select the Alignment Menu L2 POWER. Press the V/M button (the ? icon will appear on the display). Press the PTT switch to transmit and rotate the DIA

46、L knob so that the Power Meter setting is 1.0 W (0.1 W). Release the PTT switch, and then press the V/M but- ton (the ? icon will disappear on the display). TX Power (L1) Adjustment (L1 POWER) Connect the test equipment as shown in Figure 1: TX Alignment Setup. Rotate the DIAL knob to select the Ali

47、gnment Menu L1 POWER. Press the V/M button (the ? icon will appear on the display). Press the PTT switch to transmit and rotate the DIAL knob so that the Power Meter setting is 50 mW (+30 mW/ -20 mW) (VX-8E Type: 0.2W0.05W). Release the PTT switch, and then press the V/M but- ton (the ? icon will di

48、sappear on the display). TX Deviation Adjustment (MAX DEV) Connect the test equipment as shown in Figure 1: TX Alignment Setup. Rotate the DIAL knob to select the Alignment Menu MAX DEV. Set the AF Signal Generator output to 50 mVrms with a 1 kHz audio tone. Press the V/M button (the ? icon will app

49、ear on the display). Press the PTT switch to transmit and rotate the DIAL knob so that the Deviation Meter setting is 4.2 kHz 0.2 kHz (USA version) or 4.5 kHz 0.2 kHz (EXP/EU versions). Release the PTT switch, and then press the V/M but- ton (the ? icon will disappear on the display). 11VX-8R/E and VX-8DR/E T