1、106 Spectrum Analyzers Measurement For Digital Mobile Communications I For PHS, PDC and NADC Standards (GSM/DCS1800/DCS1900/DECT/CDMA Measurement Optional) I Dual Mode Analysis Spectrum Analyzer Mode Digital Transmission Tester Mode I Built-In Digital Modulation Analysis Func- tion I Menu Operation

2、Automatically Set Standard Parameters, STD Mode and Measurement Function Keys I Compact, Lightweight (17 kg), 6.5 Inch TFT Color LCD I 2 Slots Memory Card Drive R3465/3463 Modulation Spectrum Analyzers Recently, digital mobile communication systems have been the focus of much attention. The R3465/34

3、63 are new modulation spectrum analyzers for testing these new communication sys- tems. In addition to the functions offered by conventional spectrum analyzers, the R3465/3463 have functions for analyzing digital modulated signals such as modulation accu- racy and transmission speed. The units have

4、an easy-to-use one key solutions design that anyone can use. There are independent keys for STD mode which automatically sets PHS, PDC and NADC standard parameters and OBW, ACP and harmonic distortion measurement. DDS (Direct Digital Synthesizer) technology enables the R3465/ 3463s excellent basic s

5、pecifications to fit into a compact size 17 kg. These specifications include a frequency range of 9 kHz to 8 GHz (R3465) or 9 kHz to 3 GHz (R3463), highly stable narrow band sweep and highspeed measuring made possible by the newlydeveloped high speed settling synthesizer. The R3465/3463 provide tota

6、l support for digital mobile com- munication equipment in applications ranging from radio systems development to production line adjustment and test- ing. I Automatic Setting of Standard Parameters The cumbersome parameter settings required for measuring digital radio system standards such as PHS, P

7、DC and NADC (GSM, DCS1800, DCS1900, DECT and CDMA optional), are set automatically for each measurement item. See the options table for each standard measurement. I Dual Mode Analysis As well as CW mode, for conventional spectrum analysis, the R3465/3463 have a TRANSIENT mode for digital transmissio

8、n analysis of modulation accuracy and transmission speed. The unit also employ the FAST function, a newlydeveloped meas- uring algorithm which greatly reduces the measurement time. I Menu Operation The R3465/3463 have a one key solutions design for simple operation. Basic measurement and analysis fu

9、nctions can be easily started by selecting the desired measurement item. I High Performance Spectrum Analyzer Functions The R3465/3463 are high performance spectrum analyzers with ample basic functions for waveform analysis in minute detail. The newlydeveloped high speed settling synthesizer has gre

10、atly improved blanking time during narrowband sweep (span 5MHz), providing high speed measurement. The units have a frequency span accuracy of 1% or less, residual FM 3Hz p-p or less /0.1 sec, and drift 20Hz or less (span 5MHz). The R3465 also enables high frequency measurements with a dynamic range

11、 of 90 dBc using a 1.7 GHz (min.) builtin preselector. R3465/3463 RadioFans.CN 收音机爱 好者资料库 107 Spectrum Analyzers 1. Selection of Digital Radio Systems The R3465/3463 can easily switch between radio systems such as PHS, PDC and NADC (GSM, DCS1800, DCS1900, DECT and CMDA optional). 2. Selection of Mea

12、surement Items: Menu Operation The operation of R3465/3463 is simple. Measurement can be simply started by selecting the desired measurement items. TRANSIENT Measurement For Digital Mobile Communications R3465/3463 STD I NADC Standard Measurements Notes: *1. The gated sweep function and the trigger

13、detector necessary for measurement are built in the R3465/3463. *2. A wideband antenna and a standard signal generator (SG) are required. L TRANSIENT menu screen L NADC setting screen L TRANSIENT ACP (NADC) measurement REPEAT START SINGLE3. Executing Measurement I Modulation Accuracy/Frequency Error

14、 (Phase Tracking Method) Measurement High speed modulation accuracy function is provided as standard. It enables highly stable measurements I Constellation and Other Waveform Analysis Functions (Options 75, 76) Powerful support of PHS, PDC and NADC digital modulation analysis such as constellation d

15、isplay, EYE pattern display and demodulated data display.etc. Measured item Frequency stability Transient transmission characteristics RF power output Power transition time Carrier on state Modulation accuracy Adjacent channel leakage power Out of band power due to switching Spurious emissions, cond

16、ucted (at antenna terminal) Spurious emissions, radiated NADC (IS-55) *1 *2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Available option RadioFans.CN 收音机爱 好者资料库 108 Spectrum Analyzers I R3465/3464 Options Table Measurement For Digital Mobile Communications R3465/3463 Model Option PDC/PHS/NADC Tx Analysis PD

17、C/PHS/NADC Constellation (option 75) PDC/PHS/NADC Graphics (option 76) Rx Control (for R3560, option 08) GSM/DCS1800/DCS1900 Tx Analysis (options 51, 56, 58) GSM/DCS1800/DCS1900 Graphics (option 77) DECT Tx Analysis (options 52, 57, 58) CDMA Tx Analysis (option 61) CDMA Test Source Control (for R356

18、1L. Option 09) FM Deviation (option 73) Program Loader (option 15) 5 10-9/Day Crystal (option 21) R3465/R3463R3465+51R3465+52R3465+56R3465+57R3465+58R3465+61/R3463+61R3465+56+61R3465+57+61 Can be set for all combinations Can be set for all combinations Can be set for all combinations (R3465 only) OP

19、T3465+51 GSM Addition OPT3465+52 DECT Addition OPT3465+61 CDMA Addition OPT3463+61 CDMA Addition OPT3465+56 GSM Only OPT3465+57 DECT Only OPT3465+58 GSM/DECT Only + _ YesYesYesYes Yes Yes Yes Yes Available option Available optionAvailable option Available optionAvailable option Available option Avai

20、lable optionAvailable option Available option Available option Available option Available option No No NoNo No No No No No No No No No No No No No No No No No No No No No No No No NoNoNo No No NoNo No Available option Available option Available option Available option No No Available optionAvailable

21、 optionNoNoAvailable option No Yes No Yes No Yes Yes Yes No Yes Available option Yes NoNo GSM/DCS1800/DCS1900 Tx Analysis (Options 51, 56, 58, R3465 Only) The GSM Option (options 51, 56, 58) provides a burst envelope function for measurement of the ON/OFF characteristics of TDMA format digital modul

22、ated signals and a burst spectrum function, enabling spectrum analysis in the burst ON interval. GMSK signal frequency error, phase error and power measure- ment can be done at the touch of a button. I Applicable Communication Systems GSM, DCS1800 (PCN), DCS1900 (PCS) (MS/BTS) I Measurement Items Bu

23、rst envelope measurement (1 burst/1 frame/Zoom mode) Power measurement Power vs time measurement Frequency error/Phase error measurement Burst spectrum measurement Modulation spectrum measurement Switching spectrum measurement Spurious emission intensity (in-band) I GSM Graphics Option (option 77) A

24、nalysis Functions Bit frequency display Phase error display Phase error of FFT display Trellis display Demodulated data display L GSM setting screen L Modulation spectrum measurement RadioFans.CN 收音机爱 好者资料库 109 Spectrum Analyzers Measurement For Digital Mobile Communications R3465/3463 DECT Tx Analy

25、sis (Options 52, 57, 58, R3465 Only) The DECT Option (options 52, 57, 58) enables burst envelope measurement and burst spectrum measurement, conforming to various physical packets at the touch of a button. The GFSK modulation analysis function also enables measurements of Tx power, power vs time and

26、 FM deviation. I Applicable Communication Systems DECT: RFP (Radio fixed part)/PP (Portable part) I Measurement Items Burst envelope measurement Power measurement Power vs time measurement FM deviation measurement Emission due to modulation measurement Emission due to transient measurement Timing ji

27、tter measurement Spurious emission measurement Graphics display The CDMA option (option 61) enables measurements of the CDMA transmitter characteristics inluding waveform quality analysis (such as RHO) and code domain power measurements as specified by IS-95/J-STD-008. US/KOREA-cellular, US/KO- REA-

28、PCS, Japan-cellular and China-cellular base and mobile stations can be covered by a single unit. I Measurement Items Burst envelope measurement Gated output power measurement Channel power measurement ON/OFF ratio measurement OBW measurement Waveform quality measurement (Rho, , others) Code domain p

29、ower measurement Spurious emission measurement Graphics display CDMA Tx Analysis (Option 61) L CDMA code domain power measurement L CDMA setting screen L DECT setting screen L DECT FM deviation measurement 110 Spectrum Analyzers 1 dB gain compression: 10 MHz -5 dBm (input mixer level) Spurious respo

30、nse: Second harmonic distortion; Third order distortion (12.5 kHz separation, 300 Hz resolution bandwidth, video bandwidth 3 Hz max.); Image/multiple out of band response; 10 MHz to 8 GHz -70 dBc Residual response;(no input signal, input ATT 0 dB, 50 termination) 1 MHz to 3.0 GHz -100 dBm 300 kHz to

31、 8 GHz 1.7 GHz Third order distortion -75 dBc 1.7 GHz Second harmonic distortion -70 dBc -90 dBc Mixer level -30 dBm -10 dBm Frequency range 9 kHz to 3.0 GHz 50 MHz to 3.0 GHz 1.7 to 7.0 GHz 6.9 to 8.0 GHz Frequency response 1.5 dB 1.0 dB 1.5 dB 1.5 dB Frequency band 0 0 1 2 0 to -50 dBm 15 to 35C 0

32、.5dB 0 to 50C 0.6dB Measuring Functions: CW mode: Spectrum measurement, OBW, ACP, HARM measurement Transient mode: Time domain measurement, Digital modulation analysis Frequency Frequency range: 9 kHz to 8 GHz (R3465) 9 kHz to 3 GHz (R3463) Built-in YIG synchronous preselector at 1.7 to 8 GHz (R3465

33、) Frequency reading accuracy: (Start, stop, center frequency, marker frequency) (frequency read frequency reference accuracy + span span accuracy + 0.15 RBW + 10 Hz) Marker frequency counter: Resolution;1 Hz to 1 kHz Accuracy (S/N 25 dB) ;(marker frequency frequency reference accuracy + 5 Hz + 1 LSD

34、)* Delta counter ; ( frequency frequency reference accuracy + 10 Hz + 2 LSD)* * LSD: Least significant digit Frequency reference accuracy: 2 108/day, 1 107/year 5 109/day (OPT. 21) Frequency stability: Residual FM (zero span) ;3 Hz Npp/0.1 s Drift (after 1 hour warmup) ;span 5 MHz, 20 Hz (sweep time

35、 (minutes) Spectral purity: 100 dBc/Hz (10 kHz offset) 5 MHz) 1% (span 5 MHz) Resolution bandwidth (3 dB): Range; 300 Hz to 3 MHz, 5 MHz (1, 3, 10 sequence) Accuracy; 20% (RBW 1 kHz to 1 MHz) 30% (RBW 300 Hz, 3 MHz, 5 MHz) Selectivity; 15:1 (300 Hz to 5 MHz) Video bandwidth Range; 1 Hz to 3 MHz, 5 M

36、Hz (1, 3, 10 sequence) Frequency sweep: Sweep time: 50 ms to 1000 s (CW mode, spectrum measurement) Accuracy: 5% Sweep trigger: Free run, line, single, video, external Trace speed: 10 times/sec Gated sweep: Gate position/resolution 1 s to 65 ms/1 s Gate width/resolution 2 s to 65 ms/1 s Trigger: Int

37、ernal IF detection, external Amplitude Measurement range: +30 dBm to avg. display noise level Maximum safe input: Avg. continuous power (input ATT 10 dB): +30 dBm (1 W) DC input: 0 V Display range: 10 10 div Log ;10, 5, 2, 1, 0.5/div Linear; 10% of reference range/div Reference level range: Log; 105

38、 dBm to +60 dBm (0.1 dB steps) Linear; 1.25 V to 223 V (approx. 1% of fullscale steps) Input attenuator range: 0 to 70 dB (10 dB steps) Measurement For Digital Mobile Communications RBW 300 Hz to 3 MHz 15 to 35C + 0.3 dB 0 to 50C 500/sweep time in pulse measurement mode): Log; 1.2 dBp-p (RBW 1 MHz)

39、3 dBp-p (RBW = 3 MHz) Linear; 4% of reference level (RBW 1 MHz) 12% of reference level (RBW = 3 MHz) Time Domain Measurement Amplitude resolution: 12 bits Sweep time: 50 s to 2 s Trigger: Free run, single, video, IF detection, external Hold time: 200 ns to 650 ms Analog Demodulation Spectrum demodul

40、ation: Modulation type: AM and FM Audio output: Internal speaker, earphone jack, adjustable volume Marker pause time: 100 ms to 1000 s Digital Modulation Analysis Applicable modulation system: /4QPSK (PHS, PDC, NADC) Input range: 10 MHz to 7.5 GHz, at -30 to +30 dBm Average power: (after calibration

41、, automatic setting) Measurement accuracy; (Transient mode) 0.8 dB (in PHS, PDC, NADC bands, 15 to 35C) 1.0 dB (in PHS, PDC, NADC bands, 0 to 50C) OBW: Standards measurement possible ACP:(Transient (frequency)/CW mode) Spurious: -20 to -65 dBc(-70 dBm or more, Transient mode) Modulation analysis: GP

42、IB: IEEE-488 bus connector, rear panel RS232: D-SUB 9 pin, rear panel P-I/O: D-SUB 25 pin, rear panel EXT key: DIN, front panel General Specifications Temperature: Operating temperature 0 to 50C, 85% RH max. Power supply: AC 100/220V, switched automatically Voltage: 100 to 120 V, 220 to 240 V Power

43、consumption: 300 VA (max.) Frequency: 50/60 Hz Weight: 17 kg max. (R3465), 16.5 kg (R3463), (excluding options, front cover and accessories) External dimensions: Approx. 177 (H) 350 (W) 420 (D) mm (excluding handle, feet and front cover) Memory card drive: 2 slots, front panel Connector ; JEIDA Ver.

44、 4.2/PCMCIA 2.1 Digital Modulation Analysis Function Provided Standard R3465/3463 PHS 0 to -57 dB (600 kHz offset) 0 to -62 dB (900 kHz offset) PDC 0 to -60 dB (50 kHz offset) 0 to -64 dB (100 kHz offset) NADC 0 to -55 dB (30 kHz offset) 0 to -60 dB (60 kHz offset) 0 to -60 dB (90 kHz offset) (NADC

45、RBW = 1 kHz) Accessories Power cable: A01412 Input cable: MC-61 Converter adapter: JUG-201 A/U Power fuse: 21806.3 (6.3 A) Options Option 08 Rx Control Option (for R3560) Option 09 CDMA Test Source Control Option (for R3561L) Option 15 Program Loader Option Option 21 5 10-9/Day Xtal Option *2 Option

46、 51 GSM Option *2, *3 Option 52 DECT Option *2 Option 56 GSM Only Option *1, *2, *3 Option 57 DECT Only Option *1, *2 Option 58 GSM/DECT Only Option *1, *2, *3 Option 61 CDMA Option Option 73 FM Deviation Measurement Option Option 75 Constellation Option (for PDC/PHS/NADC) Option 76 Graphics Option

47、(for PDC/PHS/NADC) Option 77 GSM Graphics Option *2 Option 85 JIS Rack Mount Set Option 86 EIA Rack Mount Set *1: When this option is mounted, functions for measuring PHS, PDC and NADC standards are not available. *2: Option can only be set on R3465. *3: GSM option includes GSM, DCS1800, and DCS1900

48、 (PCS1900 in the U.S). Application Software PR34650440-ICPHS Auto Test (Tx, manual mode) PR34650441-ICPHS Remote Test (Tx, remote mode) PR34650442-ICPHS Auto/Remote Test (Tx, manual/remote) PR34650450-ICPHS TRx Auto Test (manual mode)*1 PR34650451-ICPHS TRx Remote Test (remote mode)*1 PR34650452-ICP

49、HS TRx Auto/Remote Test (manual/remote mode)*1 PR34650120-ICPDC-MS TRx Auto Test (manual mode)*1 PR34650121-ICPDC-MS TRx Remote Test (remote mode)*1 PR34650122-ICPDC-MS TRx Auto/Remote Test (manual/remote mode)*1 PR34650710-ICCDMA-BS Tx Auto Test (manual mode)*2 PR34650711-ICCDMA-BS Tx Remote Test (remote mode)*2 PR34650712-ICCDMA-BS Tx Auto/Remote Test (manual/remote mode)*2 PR34650160-ICPDC-MS Technical Conformance Measurement Software *3 PR34650460