Anritsu 11410-00225 电路图.pdf

上传人:cc518 文档编号:199442 上传时间:2025-03-08 格式:PDF 页数:14 大小:1.40MB
下载 相关 举报
Anritsu 11410-00225 电路图.pdf_第1页
第1页 / 共14页
Anritsu 11410-00225 电路图.pdf_第2页
第2页 / 共14页
Anritsu 11410-00225 电路图.pdf_第3页
第3页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Anritsu 11410-00225 电路图.pdf》由会员分享,可在线阅读,更多相关《Anritsu 11410-00225 电路图.pdf(14页珍藏版)》请在收音机爱好者资料库上搜索。

1、The Worlds Leading Cable and Antenna System Analyzer Site Master Transmission Line and Antenna Analyzer 2 MHz - 20 GHz RadioFans.CN 收音机爱 好者资料库 THE LEADING CABLE AND ANTENNA ANALYZER FOR WIRELESS PROFESSIONALS Anritsus Site Master cable and antenna analyzer is the preferred choice of service provider

2、s, network operators and contractors worldwide who install, deploy, maintain and troubleshoot wireless communi- cation systems. Featuring an advanced synthesizer-based, handheld, battery-operated design, Site Master helps wireless field engineers and technicians detect cable feedline and antenna sys

3、tem problems before they become costly, time-consuming system failures. Superior immunity to ambient RF levels, and excellent directivity and source match ensure accurate and repeatable measurements. Easy-to-Use Site Masters menu driven interface requires little training and simplifies the field eng

4、ineers and technicians task of deployment, site-to-site maintenance and troubleshooting by identifying, recording and solving problems without sacrificing measurement accuracy. Store ten test setups for fast repeatable testing. Store up to 200 measurement traces in nonvolatile memory. Quickly select

5、 cable type and test parameters without setup error. Multilingual user interface features on screen menus and messages in 6-different languages. InstaCalcalibration module simplifies Site Master calibration. Accurate, Repeatable Measurements Utilizing vector error correction, Site Master delivers ac

6、curate, reliable and repeatable Return Loss/SWR and Fault Location measurements. Site Masters high immunity to interference allows users to conduct measurements of an active site without the loss of accuracy. Locate long range problems with 517 data points. Superior immunity to on-channel interferen

7、ce for testing at co-located antenna sites. Large, high-resolution display allows for easy viewing and trace interpretation under a variety of conditions. Full range of marker and limit functions facilitate quick, comprehensive measurements. Rugged and Reliable Designed specifically for field enviro

8、nments, Site Master withstands harsh environments and rough handling. Built-in energy conservation combined with a rechargeable battery pack allows users to extend battery life beyond an eight hour work day. Site Master can also be operated from a 12.5 Vdc source such as an AC-DC adapter or automoti

9、ve cigarette lighter adapter, which also simultaneously charges the battery. Powerful Data Analysis Software Powerful data analysis software comes with every Site Master unit, providing users with an easy method of analyzing system performance, trends and problems in addition to professional report

10、generation. Site Master PC software is Windows 95/98/NT4/2000/ME/XP workstation compatible and supports long alpha-numeric file names for descriptive data labeling. Store an unlimited number of data traces for comparison to historical performance. Quickly and easily download data traces from the Sit

11、e Master to a PC database with a single menu selection. Site Master Software Tools provides a data base to compare maintenance interval performance to site commissioning data. The Distance-To-Fault display pinpoints problem areas before they degenerate into failures. In the graph to the left, a loos

12、ened connector changes the return loss characteris- tic from 38 dB to 33 dB (90 dB isolation ranges required at RF-RF repeater sites. Measuring antenna isolation during periodic maintenance intervals conveniently verifies antenna position after harsh weather. If the antenna has been moved from the i

13、nstalled mounting angle, the change in side lobe and back lobe coupling magnitudes between the antennas causes a clear performance change.Tx-Rx isolation of duplexers and filters is easily tested with Site Masters 90 dB dynamic range. Filters are easily aligned and verified to manufacturers specific

14、ations. Site Masters high dynamic range enables LNA measurements at ground level. Accurately measure antenna isolation with Site Masters high dynamic range. Amplifier Gain Test Measurement. 2-PORT SITE MASTER RF IN RF OUT ANTENNA ANTENNA ISOLATION 2-PORT SITE MASTER RF IN RF OUT LNA 2-PORT SITE MAST

15、ER RF IN RF OUT LNA ANTENNA TEST SIGNALANTENNA LNA DUPLEXER Tx Rx 5 SITE MASTER S800 SERIES FOR MICROWAVE APPLICATIONS The Site Master S800 series, is the most accurate and convenient tool available for field installation, verification, troubleshooting and repair of microwave communication systems.

16、Difficult test specifications are easy to verify.The S800 series improves quality and reduces maintenance expenses by providing vector corrected calibration and a convenient user interface.These new microwave Site Master models test both waveguide and coaxial cables more conveniently than laboratory

17、-sized scalar analyzers or microwave test sets. Vector Error Correction Vector error correction within the S800 series improves the quality and convenience of measurements compared to traditional scalar techniques. Accuracy and repeatability account for errors such as test port match and source matc

18、h errors.Vector correction allows the test port to achieve the highest commercial directivity to 50 dB (frequency range dependent) using relatively small calibration components. Waveguide Dispersion Vector error correction also improves the quality of Distance- To-Fault data. Not only is the reflect

19、ion magnitude more accurate, but the waveguide dispersion correction for fault location (different frequencies propagate at different speeds) is more accurate and repeatable.The post- vector corrected data accounts for the non- dispersive length of coaxial cable preced- ing the input of the waveguid

20、e under test. Unlike scalar-based systems, the Site Master S800 Series do not suffer reflec- tion magnitude errors (a failure looks better than actual) and length inaccuracies in proportion to the relative lengths of the coaxial input cable and waveguide under test. SITE MASTER ANTENNA REFERENCE PLA

21、NE TEST PORT CABLE COAX-TO-WAVEGUIDE ADAPTER FLEX WAVEGUIDE JUMPER FLEX WAVEGUIDE JUMPER CALIBRATION COMPONENTS PRESSURIZED WAVEGUIDE TRANSMISSION LINE 1/8 WAVEGUIDE SHORT 3/8 WAVEGUIDE SHORT WAVEGUIDE LOAD Vector Correction Avoids Bulky Waveguide Coupler Waveguide Calibration The test port interfac

22、e to the waveguide under test is a small coaxial-to-waveguide adapter rather than a bulky precision coupler. The calibration components include two offset shorts,1/8 and 3/8 wavelength, and a precision load.The two offset shorts eliminate reference error suffered by scalar systems when only a single

23、 waveguide short is used to determine the 0.0 dB reflection reference level. Site Masters innovative flange design mates to square, rectangular or circular flanges. For a given waveguide size, only one calibration set is required. Site Masters waveguide calibration components are built with precisio

24、n alignment pins that mate the companion coaxial to waveguide adapters. As a result, proper alignment of waveguide is fast and convenient. 6 SITE MASTER WITH INTEGRATED SPECTRUM ANALYSIS CAPABILITY Site Master models S114C and S332C add spectrum analysis capability to the standard cable and antenna

25、analyzer function of Site Master. Now technicians and field engineers can identify and solve RF system problems like coverage, interference, antenna alignment, and in-band interference from unwanted sources among other path related signal problems in addition to cable and antenna analysis measuremen

26、ts. Wide dynamic range, featuring 95 dBm DANL Increased video bandwidth selection Quick zoom-in, zoom-out display Manual and automatic coupling/decoupling of span, RBW and VBW functions Manual and automatic attenuator control Field strength measurement Occupied bandwidth measurement Channel power me

27、asurement Adjacent channel power measurement Field Maintenance Ideal for field maintenance, the Site Master S114C, S332C simplifies the task of going site-to-site identifying, recording and solving problems. Moreover, these tasks can be completed in a fraction of the time required to haul bench-top

28、or other portable equipment to the field. Featuring a synthesizer- based design and built-in measurement functions allow for easy verification of system performance. User-frequency menu functions, high sensitivity, and excellent repeatability pinpoint the smallest RF signal levels. Harmonics, Occupi

29、ed Bandwidth, Channel Power and potential interference can be measured before small problems grow into big, costly, time- consuming headaches and unwanted site down time. RF Interference Identifying the RF Interference problems can be very difficult. Site Masters low noise floor make small signals e

30、asily detectable. Channel Power Performing channel power measurements help to determine if a transmitter is operating in compliance with system specifi- cations by measuring the power and power spectral density in a given channel bandwidth.Another common transmitter measure- ment is adjacent channel

31、 leakage power that measures the amount (or ratio) of power leakage into adjacent radio channels. Signal Mapping Ideal for site surveys and other signal mapping applications, the Site Master Models S114C and S332C can optimize placement of antennas and access points in a WLAN or WPBX network. Identi

32、fication of potential in-band interference as well as transmitted signal quality can be easily performed as the installer moves about the installation site. Although Site Master features built-in analytical and reporting functions, users can also download measurement data to a PC for additional anal

33、ysis or report generation. Site Masters user friendly Software Tools is a Windowsprogram designed specifically for cable and antenna analysis and will run on any computer with Windows 95/98/NT4/2000/ME/XP.Test data can be analyzed and compared to historical performance. Up to 200 Site Master trace m

34、emory locations can be down loaded with a single menu selection. Build historical records with an unlimited number of traces in one document. Familiar Windows 95/98/NT4/2000/ME/XP interface simplifies data analysis and report generation. Intelligent drag-and drop automatically converts traces to a c

35、ommon scale and speeds fault identification. Supports long file names for easy measurement data identification. Smith Chart function displays S11 vector magnitude and phase data, allowing system components to be impedance matched for optimum performance. 7 PC SOFTWARE TOOLS FOR PROFESSIONAL ANALYSIS

36、 AND REPORT GENERATION Analysis displays include MilliRho (m) reflection coefficient data format or S11Smith Chart. The on-screen measurement calculator now also includes Transmitted power percentage. Print outs support multiple plots per page. Create new database files or add to an existing databas

37、e. Site Master Software Tools quickly stores antenna system test data to a single relational database file. Create professional reports with Site Master software tools. The above plot illustrates connector related problems that can be easily understood. Anritsu Site Master Models S113CS114CS331CS332

38、CS251CS810AS818AS820A Frequency Range (MHz)2-16002-160025-400025-4000625-25003.3-10.5 GHz3.3-18 GHz3.3-20 GHz Resolution kHz1010100100101 MHz1 MHz1 MHz Markers66666444 Display Point (Max.)517517517517517130130130 Interference Immunity (dBm) On-Frequency(1)+10+1055+10 RF Out; +30 dBc RF In(3)101010 O

39、n-Channel(2)+17+17+17+17+17N/AN/AN/A Calibration: Instrument Configurations1010101010666 Data Storage Reporting: Alpha NumericYesYesYesYesYesNoNoNo Time/Date StampYesYesYesYesYesNoNoNo NumericYesYesYesYesYesYesYesYes Memory Locations (Max.)200200200200200707070 Measurement Characteristics(4) Return

40、Loss SWR Cable Loss DTF Insertion Gain Isolation Insertion Loss Spectrum AnalysisN/A0.1-1600 MHzN/A0.1-3000 MHz N/AN/AN/AN/A 8 NEVER BEFORE HAS ONE ANALYZER FAMILY SOLVED SO MANY ANTENNA SYSTEM PROBLEMS Whether your system is cellular, PCS/DCS, 3G, paging, data, SMR, WLAN/WPBX or any other type of w

41、ireless service covering the 2 MHz to 20 GHz frequency range, Site Master by Anritsu offers a cable and antenna analyzer solution for you. 1. On-Frequency Interference Immunity is specified to within 10 kHz of the carrier frequency. 2. On-Channel Interference Immunity is specified at 1 MHz of the ca

42、rrier frequency. 3. In most field applications, Immunity is typically better because interferring signals are modulated and varying in frequency rather than CW. Measurements were made in CW mode by injecting a signal into the Site Master through a coupler. 4. All Anritsu Site Master models include R

43、eturn Loss, SWR, Cable Loss, and Distance-To-Fault. 9 SITE MASTER OPTIONS AND ACCESSORIES RF Power Monitor (Option 5) The optional RF Power Monitor features precision, high return loss (low SWR) detectors.This excellent impedance match significantly reduces the largest component of power measurement

44、 error, mismatch uncertainty. Display formats include absolute power (dBm or Watts) and relative power (dBr or %). Built-in Auto-Averaging automatically reduces the effects of noise while zeroing control allows optimum measurement accuracy at low power levels. InstaCalCalibration Module* The InstaCa

45、l calibration module is available for all one-port Site Master models (S113C, S114C, S331C and S332C). With InstaCal, users can cut the time required to calibrate the Site Master by as much as 50%. Moreover, InstaCal reduces the potential for calibration error. With discrete calibration components u

46、sers are required to connect, disconnect, and reconnect the various calibration components during the calibration process, which greatly increases the potential for calibration/measurement error. With InstaCal, users are only required to connect the InstaCal calibration module once the calibration p

47、rocess sequences automatically, ensuring an accurate calibration of the Site Master.The benefit is calibrated measurements in much less time. Microwave Accessories Calibration components mate directly to a variety of commercial and standard military flanges eliminating the necessity of bulky, precis

48、ion waveguide couplers. A few examples of waveguide adapters are 35UA187N, 35UM40N, and 35UM58. Bias Tee (Option 10A-S251C Only) The optional bias tee is integrated inside the Site Master and is designed for applications where both DC and RF signals must be applied to a device under test, such as a

49、tower mounted amplifier (TMA). DC voltages of up to 15 volts at 0.24 amps may be applied to test devices with negligible effect on RF performance as an RF input DC block isolates the input port from the applied bias voltage. InstaCalModule ICN50 *The InstaCalCalibration Module exhibits slightly degraded directivity performance compared to precision loads. Users having applications that require DTF-RL measure- ments 38 dB may want to consider using precision load calibration components in place of the InstaCal calibration module for greater measurement

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 仪器仪表 > Anritsu

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号