BK PRECISION 9130 Instruction 电路图.pdf

上传人:cc518 文档编号:199539 上传时间:2025-03-08 格式:PDF 页数:48 大小:1.94MB
下载 相关 举报
BK PRECISION 9130 Instruction 电路图.pdf_第1页
第1页 / 共48页
BK PRECISION 9130 Instruction 电路图.pdf_第2页
第2页 / 共48页
BK PRECISION 9130 Instruction 电路图.pdf_第3页
第3页 / 共48页
亲,该文档总共48页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BK PRECISION 9130 Instruction 电路图.pdf》由会员分享,可在线阅读,更多相关《BK PRECISION 9130 Instruction 电路图.pdf(48页珍藏版)》请在收音机爱好者资料库上搜索。

1、 Model 9130 Triple Output Programmable DC Power Supply INSTRUCTION MANUAL MODEL 9130 RadioFans.CN 收音机爱 好者资料库 Safety information Please review the following safety precautions before operating our equipment. General information The following safety precautions should be observed before using this pro

2、duct and any associated instrumentations. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information carefully before usin

3、g the product. Refer to this manual for complete product specifications. If the product is used in a manner not specified, the protection provided by the product may be impaired. Before performing any maintenance, disconnect the line cord and all test cables. Protection from electric shock Operators

4、 of this instrument must be protected from electric shock at all times. The responsible body must ensure that operators are prevented access and/or insulated from every connection point. In some cases, connections must be exposed to potential human contact. Under these circumstances personnel must b

5、e trained to protect themselves from the risk of electric shock. If the circuit is capable of operating at or above 1000 volts, no conductive part of the circuit may be exposed. Definition of users Responsible body is the individual or group responsible for the use and maintenance of equipment is op

6、erated within its specifications and operating limits, and for ensuring that operators are adequately trained. This product should only be used as intended. Users must be trained in electrical safety procedures and proper use of the instrument. Users must be protected from electric shock and contact

7、 with hazardous live circuits. Service is only to be performed by qualified service personnel. Safety symbols and terms Connect it to safety earth ground using the wire recommended in the user manual. The symbol on an instrument indicates that the user should refer to the operating instructions loca

8、ted in the manual. Complies with the essential requirements of the European directives. Certification We certify that this product met its published specifications at time of shipment from the factory. RadioFans.CN 收音机爱 好者资料库 1 TABLE OF CONTENTS 1. INTRODUCTION. 3 2. QUICK START. 4 2.1 Front enable

9、or disable parallel or series tracking mode; store and recall operating states or enable/disable individual outputs. The 9130 is ideally suited for applications in Electronic Test, Production and Service, where multiple independent DC supplies are required and bench space is at a premium. Key Featur

10、es ? 3 independent, fully programmable and electrically isolated outputs ? Series or parallel operation ? Display Voltage and Current for of all 3 channels simultaneously ? Over Current (OCP) and Over Temperature (OHT) protection ? Very compact foot print ( 2U x 1/2) ? Bright and easy to read displa

11、y (VFD technology) ? High resolution, accuracy and stability ? Output on/off control ? Low ripple and low noise ? SCPI compatible command set, communicate via USB or RS232 port ? Application Software for front panel emulation and simple test sequence generation ? 50 memory locations for instrument s

12、tate storage & recall ? Convenient data entry via knob or numerical key pad ? Rack mount kit available 4 2. Quick Start This chapter will help you getting acquainted with the front panel operation of this power supply. 2.1 Front & Rear Panel Front panel 1 2 3 4 5 6 7 1 VFD display 2 Rotary knob 3 Ma

13、in power switch 4 Numerical key pad and “Esc” key 5 Function keys 6 Cursor position & Channel Selection keys, “Enter” key 7 Output terminals 5 Rear Panel 1 2 3 4 5 6 1) Terminal block for GND reference and additional negative output terminal 2) AC receptacle 3) Ventilation holes 4) Interface connect

14、or for remote control of power supply 5) 110V/220V AC Power selection switch 6) Fuse compartment 2.2 Preliminary Checkout The following steps will help you verify that the power supply is ready for use. 1Check the list of supplied items Verify that you have received the following items with your pow

15、er supply. If anything is missing, contact your authorized B+K Precision distributor. Power cord Instruction manual Calibration Report Communication cable Software installation disk 6 2Connect the power cord and turn on the power supply When you turn on the power supply, the front- panel display wil

16、l light up briefly while the power supply performs its power- on self- test. All the VFD annunciators will turn on at once. Check for any missing display segments. In the event that there is no response when you turn on the power supply, refer to section 5 of this chapter for additional information.

17、 3. System Checkout At power up, the instrument will automatically perform a self test routine. During this time, the following should be displayed: System Test, Please wait! followed by 0.000V 0.000V 0.000V Or: Note: The first row is the output voltage for channels 1 3. The second row will display

18、the on/off state or the output current of each channel. In case the self test routine is not successful, you may see one of the following: If the EEPROM is damaged, the VFD will display the following: EEPROM Error If the last operation data which should be stored in the EEPROM was lost you should se

19、e Data Check Error If the latest data about off- time in EEPROM was lost, the VFD will display Load OffTime Fail If the calibration data stored in the EEPROM was lost, the VFD will display 10.000V 11.000V 3.000V 2.000A 3.000A 3.000A 7 CH X Lost Calibration. Note: “X” denotes the channel for which ca

20、libration data was lost. If the calibration data in the EEPROM is corrupted or the factory calibration values are lost, the VFD will display the following: Lost Factory Calibration Note: You will see a “?” on the VFD, in case of any errors are encountered during the self test routine. 4Output Verifi

21、cation The following procedures verify that the power supply outputs the correct voltage and current levels and properly responds to entries from the front panel. ? Voltage Output Checkout The following steps verify basic voltage functions without load. 1) Turn on the power supply. 2) Turn on the ou

22、tputs using the On/Off key Note: Flashing voltage values indicates that the power supply is in “Set mode, Set mode means that the VFD display shows the set values for voltage and current. In “meter mode” the display will indicate the actual output voltage and current. 3) Check that the front- panel

23、voltmeter properly responds to number key entries Enter a different voltage value and wait a few seconds until the meter mode activates. Verify that the actual output value voltage is identical to the set value. Also verify that the displayed current value is close to zero. 4) Ensure that the voltag

24、e level can be adjusted from zero to the maximum rated value. 5) Verify channels 2 & 3 according to steps 1) 4) ? Current Output Current The following steps check basic current functions with a short across the power supplys output. 1) Turn on the power supply 2) Turn the output off Press On/Off key

25、 to ensure that the outputs are off. (bottom row indicates “OFF”) 3) Connect the (+) and (- ) output terminals of channel 1 with a short, insulated test lead. Use a wire size sufficient to handle the maximum current. 4) Set the voltage value with 1V 5) Turn on the output using the On/Off key. 6) Adj

26、ust the current value Enter a different current value, wait until the instrument is in meter mode, then make sure that the 8 displayed current value (actual output value) is the same as the set value. 7) Ensure that the current can be adjusted from zero to the maximum rated value. 8) Turn off the po

27、wer supply and remove the short wire from the output terminals. 9) Verify channels 2 & 3 according to steps 1) 8) 5If the Power Supply Does Not Turn On Use the following steps to help resolve problems you might encounter when turning on the instrument. 1). Verify that there is AC power applied to th

28、e power supply. Verify that the power cord is firmly plugged into the power receptacle on the rear panel of the power supply. Make sure the power outlet you are using is working properly and verify that the power supply is turned on. 2). Verify the power-line voltage setting. Make sure the voltage s

29、elector switch is set according to the present line voltage (110VAC or 220VAC). Change the voltage setting if its not correct. 3). Verify that the correct power-line fuse is installed. Model Fuse Description Fuse 3.15A T250V(220V AC) 9130 Fuse 6.30A T250V(110V AC) If the fuse is blown replace it acc

30、ording to the table above. 6To Adjust the Carrying Handle To adjust the position, grasp the handle on each side and pull outwards, then rotate the handle to the desired position. Bench-top viewing positions Carrying position 9 7. To Rack Mount the Instrument You can mount the power supply in a stand

31、ard 19- inch rack cabinet using the IT- E151 rack mount kit. Note: Remove the carrying handle and the two plastic ears before rack- mounting the instrument. To remove the handle, grasp the handle on the side, pull outwards and rotate it to a special position where the arrow on the handle and the arr

32、ow on the plastic ears are in opposite directions. Now you can pull the handle outwards. After removing the handle, you can remove the two plastic ears with a screw driver. 10 3. Specifications 3.1 Specifications Parameter 9130 Voltage 030V2,05V1 Current 03A2,03A1 Output ratings LVP* 031V2,06V1 Volt

33、age 0.01%+3mV Load Regulation (of output+offset) Current 0.01%+3mA Voltage 0.01%+3mV Line Regulation (of output+offset) Current 0.1%+3mA Voltage 1mV Programming Resolution Current 1mA Voltage 1mV Readback Resolution Current 1mA Voltage 0.03%+10mV Programming accuracy (12 months) (of output+offset) C

34、urrent 0.1%+5mA Voltage 0.03%+10mV Readback accuracy (25 C 5 C) (of output+offset) Current 0.1%+5mA Ripple: 1mVrms/3mVp- p Ripple & noise Voltage Noise: 3mVrms Voltage 0.03%+10mV Temperature coefficient (0 C 40 C) (of output+offset) Current 0.1%+5mA Voltage 0.03%+10mV Readback Temperature Coefficien

35、t (of output+offset) Current 0.1%+5mA Tracking Accuracy Series Operation Current 0.05%+10mA Voltage 0.02%+5mV Tracking Accuracy Parallel Operation Current 0.1%+20mA Time set 1s999999s Output Timer Resolution 1s Weight 19.8 lbs, (9 kg) Dimensions 214.5mm(W) 88.2mm (H) 354.6mm (D) 8.45in(W) x 3.8in(H)

36、 x 13.9in(D) *) LVP: Limit Voltage Protection. Limits the voltage than can be set either via the front panel or remote control command. NOTE: Specifications and information are subject to change without notice. Please visit for the most current product information. 11 3.2 Supplemental Characteristic

37、s State Storage Memory 50 user- configurable stored states Recommended Calibration Interval 1 year AC Input Ratings (selectable via switch on the rear panel) 220AV10%,4763Hz 110AV10%,4763Hz Maximum power consumption Model 9130 Power 750VA Cooling Fan cooled Operating Temperature 0 to 40 C for max ra

38、ted output Storage Temperature - 20 to 70 C for storage environment. Environmental Conditions Designed for indoor use in an installation category II, pollution degree 2 environment. Designed to operate at maximum relative humidity of 95% and at altitudes of up to 2000 meters. 12 4. Front-panel Opera

39、tion So far we have covered the quick start chapter which briefly introduced the front panel operation and how to check basic voltage and current functionality. This chapter describes in detail how to operate the instrument manually via the front- panel keys. 4.1 Front-panel Operation Overview ? The

40、 power supply is shipped from the factory ready for front- panel operation mode. At power- on, the power supply will automatically enter the front- panel operation mode and the instrument can be controlled via the font panel keys and knob. The power supply enters remote mode as soon as a valid remot

41、e command is received via the communication connector in the rear. Switching to remote mode does not impact the supplys output parameters. In remote mode, front- panel operation is disabled. If the power supply is in remote mode, and the LOCAL key is not disabled, you can revert to manual mode by pr

42、essing the LOCAL key . ? The power supply is in Meter mode when it is powered on. In this mode, the VFD will display the actual voltage and current output value. If the user adjusts the knob while in this mode, the power supply will automatically enter Set mode then revert back to meter mode and dis

43、play the modified voltage and current values. ? The output of the power supply can be enabled/disabled from the front panel by pressing the On/Off key. ? The VFD also displays operation states or error information. “”means the power supply is in remote mode. If an error occurred, ”?” will be display

44、ed. ? If the power supply is in Set mode, you can modify parameters using the knob. If the power supply is in menu operation, the knob is used for menu selection. If the power supply is in the regular output mode you can use the knob to set the voltage value. ? If “?” is displayed on the VFD, please

45、 consult the submenu “error information” for more details (see chapter 4.4). 13 4.2 Panel Description 4 12 7 5 3 6 Esc 0 98 Recall Menu Enter V-setV-setI-setI-set Save On/Off 09 Use keys 13 to control the output state of the 3 channels。Use keys 46 to set the voltage and keys 79 to set the current va

46、lue for each channel. V-setV-set Set the voltage value I-setI-set Set the current value Save Save the current setup of the power supply to internal memory Recall Recall the setup from internal memory Menu Set general parameters of the power supply On/Off Set the output state of the power supply Up a

47、rrow key, select a menu or channel Down arrow key, select a menu or a channel 4.3 VFD Description and Wiring Diagram Explanation of annunciators on the display OFF The output is off. The key panel is locked. The power supply is in remote mode. ? There is some error or fault with the power supply. Indicates the channel currently selected 4.4 Menu Descriptions Press Menu to indicate operation mode. View the menu on the VFD, and use the keys or the knob to 14 s

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 仪器仪表 > B+K

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号