Biddle 210170_UG 电路图.pdf

上传人:cc518 文档编号:199763 上传时间:2025-03-08 格式:PDF 页数:6 大小:288.93KB
下载 相关 举报
Biddle 210170_UG 电路图.pdf_第1页
第1页 / 共6页
Biddle 210170_UG 电路图.pdf_第2页
第2页 / 共6页
Biddle 210170_UG 电路图.pdf_第3页
第3页 / 共6页
亲,该文档总共6页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Biddle 210170_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle 210170_UG 电路图.pdf(6页珍藏版)》请在收音机爱好者资料库上搜索。

1、MEGGER210170 Insulation clean, and with no broken or cracked insulation. Replacement fuses must be of the correct size, type and rating. Symbols used on the instrument Caution: risk of electric shock Caution: refer to accompanying notes Equipment protected throughout by Double Insulation (Class II)

2、NOTE THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. RadioFans.CN 收音机爱 好者资料库 OPERATION Default Voltage measurement The 210170 will act as a default voltmeter (0 to 600 V a.c.) with any of the Insulation test positions selected. The Test push must not be pressed when makin

3、g a voltage test. Note:- The 210170 is internally fuse protected to 500 V. For fuse protection with supplies above 500 V, use Fuse Probe Kit FPK5. 1.Select any Insulation test position with the rotary selector switch. 2.Carefully connect the test leads to the circuit under test. Do not press the Tes

4、t push. 3.Read the voltage measurement from the voltmeter scale. 4.Carefully disconnect the test leads. Low Resistance measurement () 1.Select with the rotary selector switch. 2.Ensure that all test leads are clean and in good condition, and connect them to the isolated circuit under test. 3.Any poi

5、nter deflection indicates a live circuit, and testing should be aborted. 4.Press the Test push, and keep it pressed while turning the generator handle. 5.Read the measurement from the k scale. 6.Disconnect the test leads. Insulation Testing (M) Automatic circuit discharge is effective when the test

6、button is released, and decaying voltage is indicated by the scale needle until the circuit is discharged. 1.Select M with the rotary selector switch. 2.Ensure that all test leads are clean and in good condition, and connect them to the isolated circuit under test. 3.Any pointer deflection indicates

7、 a live circuit, and testing should be aborted. 4.Press the Test button, and keep it pressed while turning the generator handle. 5.Read the measurement from the M scale. 6.Release the Test push and monitor any scale needle movement to confirm when any discharging voltage decays to zero. 7.When the c

8、ircuit has discharged, disconnect the test leads. Refer to Safety Warnings before using the instrument MEASUREMENT SCALES RadioFans.CN 收音机爱 好者资料库 Using the Guard Terminal For basic insulation tests and where there is little possibility of surface leakage affecting the measurement, it is unnecessary

9、to use the guard terminal. In cable testing, there may be surface leakage paths across the insulation between the bare cable and the external sheathing due to the presence of moisture or dirt. Where it is required to remove the effect of this leakage, particularly at high testing voltages, a bare wi

10、re may be bound tightly around the insulation and connected via the third test lead to the guard terminal G. The guard terminal is at the same potential as the negative terminal. Since the leakage resistance is effectively in parallel with the resistance to be measured, the use of the guard causes t

11、he current flowing through surface leakage to be diverted from the measuring circuit. The instrument therefore reads the leakage of the insulator, ignoring leakage across its surface. SPECIFICATION Insulation Ranges Measuring Ranges:0 - 20,000 M at all test voltages Test Voltages (d.c.):100 V; 250 V

12、; 500 V; 1kV on open circuit Test V. Accuracy:5% Short Cct. Current:220 A nominal on all ranges Accuracy:3% of scale length on a 3.08 inch arc length Low resistance Range Measuring Range:0 - 5000 Open Cct. Voltage:3 V 5% Short Cct. Current:30 mA 10% Accuracy:3% of scale length on a 3.08 inch arc len

13、gth Default Voltage measurement Range:0 - 600 V a.c. Accuracy:2.5% of scale length General Specifications Overload rating:The 210170 is protected for connection to Power distribution systems up to 300 V Line - Ground, and 500 V Line - Line for Installation Category III*. Terminal Characteristics Lea

14、kage path to +ve terminal to G terminal to -ve terminal Tightly bound bare wire RadioFans.CN 收音机爱 好者资料库 AVO INTERNATIONAL Archcliffe Road Dover Kent CT17 9ENTel: +44 (0) 1304 502100 EnglandFax: +44 (0) 1304 207342 PO Box 9007 Valley Forge PA 19484-9007Tel: +1 (610) 676-8500 U.S.A.Fax: +1 (610) 676-8

15、610 4271 Bronze Way Dallas TX 75237-1017Tel: +1 (800) 723-2861 (U.S.A. only) U.S.A.Tel: +1 (214) 330-3203 (International) Fax: +1 (214) 337-3038 MEGGER SARL 29 Alle de Villemomble, 93340 Le Raincy ParisTel: +33 (1) 43.02.37.54 FranceFax: +33 (1) 43.02.16.24 This instrument is manufactured in the Uni

16、ted Kingdom. The company reserves the right to change the specification or design without prior notice. MEGGER is the registered Trade Mark of AVO INTERNATIONAL LIMITED. Copyright , AVO INTERNATIONAL LIMITED. Part No. 6172-382 - Edition 3 - Printed in England - 11GG Temp. Range: Operating: 14F to 12

17、2F Storage:4F to 158F Humidity: Operating: 70% RH at 68F, 50% RH at 104F Storage:95% RH at 95F Automatic Discharge: Capacitive circuits are automatically discharged when the Test push is released following an insulation test. Power Supply:Low voltage brushless a.c. generator Fuses:2 x 500 mA (F) 500

18、 V H.B.C. 10 kA min 114“ x 14“ To check these fuses, short all three test leads together and set the rotary selector switch on any Insulation test position. Press the Test push and keep it pressed while turning the generator handle. The needle should register approximately 2 M. A zero reading indica

19、tes that the G fuse has ruptured. An Infinity reading indicates that the +ve fuse has ruptured. Fuse Replacement: Held in a screw type holder located in the base of the instrument. Use a flat blade screwdriver to release the center part of the holder, and remove the ruptured fuse. Replace with fuse(

20、s) of the correct type, size and rating. Weight:2.2 lb Dimensions:814” (including generator handle) x 5” x 5” Cleaning:Wipe disconnected instrument with a clean cloth dampened with soapy water or Isopropyl Alcohol IPA) *Relates to transient overvoltage likely to be found in fixed installation wiring

21、. ACCESSORIES SuppliedPart Number User Guide6172-382 Test lead set comprising:- 1 black, 1 red, 1 green test lead, with alligator clips 6220-436 Test Record Card (5 supplied)210949 Optional Carrying case 217740 Fuses (500mA) x 5 6121-289 Fused probe kit FPK56111-288 Black test lead with large alliga

22、tor clip6220-295 Red test lead with large alligator clip6220-586 Green test lead with large alligator clip6220-587 Test Record cards (Pack of 20)6111-216 Publication - A Stitch in TimeAVTM21-P8B 0.5A(F) 500V HBC(10 kA) Guard fusePositive fuse REPAIR AND WARRANTY The instrument contains static sensit

23、ive devices, and care must be taken in handling the printed circuit board. If an instruments protection has been impaired it should not be used, but sent for repair by suitably trained and qualified personnel. The protection is likely to be impaired if for example; it shows visible damage; fails to

24、perform the intended measurements; has been subjected to prolonged storage under unfavourable conditions, or has been subjected to severe transport stresses. NEW INSTRUMENTS ARE GUARANTEED FOR 1 YEAR FROM THE DATE OF PURCHASE BY THE USER. Note: Any unauthorized prior repair or adjustment will automa

25、tically invalidate the Warranty. INSTRUMENT REPAIR AND SPARE PARTS For service requirements for MEGGERInstruments contact :- AVO INTERNATIONALorAVO INTERNATIONAL Valley Forge Corporate CenterArchcliffe Road 2621 Van Buren AvenueDover Norristown, PA 19403Kent, CT17 9EN U.S.A.England Tel: +1 (610) 676

26、-8579Tel: +44 (0) 1304 502243 Fax: +1 (610) 676-8625 Fax: +44 (0) 1304 207342 or an approved repair company. Approved Repair Companies. A number of independent instrument repair companies have been authorised for repair work on most MEGGERinstruments, using genuine MEGGER spare parts. Consult the Ap

27、pointed Distributor / Agent regarding spare parts, repair facilities, and advice on the best course of action to take. Returning an Instrument for Repair If returning an instrument to the manufacturer for repair, it should be sent freight pre-paid to the appropriate address. A copy of the invoice and of the packing note should be sent simultaneously by airmail to expedite clearance through Customs. A repair estimate showing freight return and other charges will be submitted to the sender, if required, before work on the instrument commences.

展开阅读全文