1、General Catalog A4454.qxd 10/1/07 1:29 PM Page 2 RadioFans.CN 收音机爱 好者资料库 Table of Contents 1BirdElectronic Corporation 1-866-695-4569www.bird- TABLE OF CONTENTS Spectrum Analysis SignalHawk SH-36S .3-4 Antenna and Cable Testing Site Analyzer6000EX.5-6 Site Analyzer2500EX.5-6 Site Analyzer1700EX and

2、1700EXP.5-6 Antenna and Cable Monitor.7 Antenna Testers .7 Laboratory Grade Instruments Calibration Cart.8 Dual Sensor internal Pre-Amplifier+24 dB gain, internal FREQUENCY Range 100 kHz to 3.6 GHz Resolution 1 Hz Uncertainty 1ppm Temperature Drift 1ppm/C Reference Aging 1ppm/year SPECTRAL PURITY 30

3、 kHz from carrier-85 dBc / (RBW Hz)1/2 100 kHz from carrier-100 dBc / (RBW Hz)1/2 100 kHz from carrier-124 dBc / (RBW Hz)1/2 BANDWIDTH Resolution100 Hz - 1 MHz in 1,3,10 steps Video 10 Hz - 1 MHz in 1,3,10 steps AMPLITUDE Measurement Range-135 dBm to +20 dBm Dynamic Range 66 dB, intermod-free Noise

4、Floor -135 dBm DANL Inherernt Spurious-80 dBm Input Related Spurious-70 dBc Amplitude Accuracy 1.0 dB typ, 1.5 dB max DISPLAY Screen8.4”, SVGA, indoor/outdoor Reference Level-140 dBm to +30 dBm, User selectable or autoscale Resolution800 x 600 pixels UnitsdBm, W, mW,W, dBV, dBmV, dBV, V, mV,V, db/m2

5、, V/m2 Offset Range-99 to 99 dB Data Points705 displayed Sweep Time2 s, full span; 1 ms, zero span TRIGGER SourcesInternal, external TTL, internal video ConnectorBNC(F) A4454.qxd 10/1/07 1:29 PM Page 3 Text Here www.bird- 1-866-695-4569 BirdElectronic Corporation 4 SignalHawk Spectrum Analyzer Stand

6、ard Accessories Model 5010B Directional Power Sensor Model 5011 Terminating Power Sensor MODEL 5012 5010B 5011 5A2720-2 5A2745-1 50-A-MFN-30 10-A-MFN-30 2-A-MFN-20 100-SA-MFN-40 25-A-MFN-30 5-A-MFN-20 TC-MNFN-1.5 TC-MNFN-3.0 TC-MNMN-1.5 TC-MNMN-3.0 TC-MNFE-1.5 TC-MNFE-3.0 TC-MNME-1.5 TC-MNME-3.0 PA-

7、MNME PA-FNME PA-MNFE PA-FNFE 4240-550 4240-500-1 4240-500-2 4240-500-10 ANT-100* ANT-400* ANT-800* ANT-900* ANT-1800* ANT-1900* ANT-2400* 7002C870 USB-Mouse USB-HUB STANDARD ACCESSORIES Soft Carrying Case, Quick Start Manual, PC Tool Software CD, Serial Cable, USB Cable, USB Drive,AC Power Supply,Au

8、tomotivePower Adapter, Headphones, Connector Cover SignalHawkT M WIDEBAND POWER SENSOR (MODEL 5012) (See page 13) Wideband Power Sensor, 350 MHz to 4 GHz, 150 mW to 150 W Avg, 400 W Peak. Measures forward and reflected average,VSWR, return loss (dB), peak, burst average, crest factor and CCDF. Forwa

9、rd average power accu- racy is 4% (0.2 dB). DIRECTIONAL POWER SENSOR (MODEL 5010B) (See page 16) Directional Power Sensor, 2 to 2700 MHz, 100 mW to 10 kW, requires ele- ments. Measures forward and reflected average,VSWR, return loss (dB), and peak. Forward average power accuracy is 5% (0.2 dB). TERM

10、INATING POWER SENSOR (MODEL 5011) (See page 14) Terminating Power Sensor, 40 MHz to 4 GHz, 10W to 10 mW (-20 dBm to +10 dBm). Measures forward average power.Accuracy is 5% (0.2 dB). TERMINATING POWER SENSOR (MODEL 5011-EF) (See page 14) Terminating Power Sensor, 40 MHz to 12 GHz, 10W to 10 mW (-20 t

11、o +10 dBm) Measures forward average power.Accuracy is 5% (0.2 dB). Model 5012 Wideband Power Sensor POWER METER OPTION Data Logging Optional Power Sensors: 5012, 5010B, 5011 Wideband 5012: 350 MHz to 4 GHz, 150 mW to 150 W average, 400 W peak, Forward Directional 5010B: 450 kHz to 2.7 GHz, 100 mW to

12、 10 kW, Forward and Reflected Terminating 5011: 40 MHz to 4 GHz, 10 uW to 10 mW, 50 W Attenuator Option DESCRIPTION Wideband Power Sensor Directional Power Sensor Terminating Power Sensor Replacement Battery Replacement USB Drive-WinCE compatible Attenuator, 50 W, 30 dB, N(M)/N(F) Attenuator, 10 W,

13、30 dB, N(M)/N(F) Attenuator, 2 W, 20 dB, N(M)/N(F) Attenuator, 100 W, 40 dB, N(M)/N(F) Attenuator, 25 W, 30 dB, N(M)/N(F) Attenuator, 5 W, 20 dB, N(M)/N(F) Test Cable, 1.5 m, N(M)/N(F) Test Cable, 3.0 m, N(M)/N(F) Test Cable, 1.5 m, N(M)/N(M) Test Cable, 3.0 m, N(M)/N(M) Test Cable, 1.5 m, N(M)/DIN(

14、F) Test Cable, 3.0 m, N(M)/DIN(F) Test Cable, 1.5 m, N(M)/DIN(M) Test Cable, 3.0 m, N(M)/DIN(M) Adapter, N(M)/DIN(M) Adapter, N(F)/DIN(M) Adapter, N(M)/DIN(F) Adapter, N(F)/DIN(F) Adapter Kit, 7/16 DIN Adapter, N(F)/N(F) Adapter, N(M)/N(M) Adapter, N(M)/SMA(F) Field Strength Antenna, 136 to 221MHz,

15、SMA(M) Field Strength Antenna, 400 to 512MHz, SMA(M) Field Strength Antenna, 824 to 894MHz, SMA(M) Field Strength Antenna, 890 to 960MHz, SMA(M) Field Strength Antenna, 1710 to 1880MHz, SMA(M) Field Strength Antenna, 1850 to 1990MHz, SMA(M) Field Strength Antenna, 2400 to 2500MHz, SMA(M) Hard Transi

16、t Case USB Mouse, Portable, Optical USB HUB, 4 Port, Ultra Mini OPTIONAL ACCESSORIES * Note:Adapter 4240-500-10 required for field strength antenna. A4454.qxd 10/1/07 1:29 PM Page 4 Antenna and Cable Testing 5BirdElectronic Corporation 1-866-695-4569www.bird- Model SA-6000EX, Model SA-2500EX, Model

17、SA-1700EX (475 points)/3.5 seconds; (949 points)/6 seconds Trace Resolution238 (default), 475, or 949 per trace data points Storage Capacity15 Set-Ups/(500) 238 point traces Immunity to Rejects on-frequency signals up to +13 dBm Interfering Signals Maximum Input Signal+22 dBm Data Transfer9-pin RS-2

18、32 (DB9), compatible with serial port InternalRechargeable Lithium-Ion batteries. 3-hour minimum operating time.Auto shut-off conserves battery life. External DC9 to 16 VDC fused, 3A External AC90 to 264 VAC 45-66 Hz; AC/DC adapter required Operating Temperature-10C to 50C (14F to 122F) Storage Temp

19、erature-40C to 80C (-40F to 176F) Humidity95% 5% max., (non-condensing) AltitudeUp to 15,000 feet (4572 m) Dimensions10.5 x 8.4 x 3.3 (265 mm x 212 mm x 83 mm) Weight5.5 lbs. (2.5 kg) UpgradeableNoYes, SA-6000EXYes SA-6000EXYes, SA-6000EX Model SA-6000EX Site Analyzer Model SA-1700EX Site Analyzer S

20、ite Analyzer SITE ANALYZERSERIES MODEL SA-6000EX (25 - 6000 MHz), MODEL SA-2500EX (780 - 2500 MHz), MODEL SA-1700EX (25 - 1700 MHz), MODEL SA-1700EXP (25 - 1700 MHz) ONE UNIT covers the entire 25-6000 MHz range! Easy to operate and field ready for first-time, occasional and experienced users. Suitab

21、le for use in Worldwide Cellular and PCS/DCS; supporting measurement of CDMA, GSM,TDMA and AMPS modulation schemes. Other applications include 3G, Broadcast, Government,Tactical Military, Microwave, Paging, Public Safety,Trunking,WLAN and WLL, and TETRA (see model matrix). Color display is clearly v

22、isible in direct sunlight WIth a single download you can view as Distance to Fault or Measurement Match-no need to store two traces. FDR (Frequency Domain Relectrometry) measurement method results in a highly reliable assessment of the health of critical components in your system; ultimately providi

23、ng a “heads-up” before a failure occurs. Fault location or DTF mode indicates VSWR or Return Loss levels at each point along the cable and antenna system length. Cable Loss function measures insertion loss of the cable system over a given frequency range. BirdsSite Analyzeris the user-friendly test

24、solution for installing, maintaining, and troubleshooting your antenna and cable systems. Field engineers and technicians rely on this rugged handheld tool to get the job done.Wireless equipment manufacturers, service providers, contractors, tower erectors, and military field personnel world wide ap

25、prove of the analyzers precision VSWR and Return Loss results. This versatile unit also includes a Digital Power Meter option to accurately measure the output power of your base station.Wideband Power Sensors are available from Bird up to 4 GHz for use with this option, and are listed with the Acces

26、sories. A4454.qxd 10/1/07 1:29 PM Page 5 Antenna and Cable Testing www.bird- 1-866-695-4569 BirdElectronic Corporation 6 Model SA-6000EX, Model SA-2500EX, Model SA-1700EX 2% (1?) over remainder of power range, and at other than calibration frequencies Accuracy 4027F Series1% (2?) across power and fr

27、eqency range; 2% (2?) over remainder Casters4 locking swivel Connector Type*Customer Specified Operating PositionVertical only Power Requirements115/230 VAC, 10%, 50/60 Hz Ambient Temp Range0C to 45C (For 10 kW 0C to +40C) Storage Temperature-20C to +70C Humidity85% Max., Non condensing AltitudeLoad

28、 derated above 5,000 feet 5 kW (59F to 95F) operating temp. 2% at other frequencies 2% at other frequencies and power levels.Add 2% to uncertainty outside 25 10C Calibration Power Level1000 W units: 700 watts. 10 kW units: 1700 watts. Uniformity2% maximum unit to unit, at calibration frequency and p

29、ower levels. Speed2 readings per second. Maximum Power10 kW units - 12 kW max. 1 kW units - 1.2 kW max. CONNECTORSCustomer specified POWER REQUIREMENTS External DC12 VDC, supplied from Bird 4421 Power Meter PHYSICAL SPECIFICATIONS Dimensions5.2 L x 2.5 W x 3.25 H Weight 13 oz. (0.8 kg) ENVIRONMENTAL

30、 SPECIFICATIONS Operating Temperature15C to 35C (59F to 95F) Storage Temperature-40C to 80C (-40F to 176F) Humidity95% maximum (non-condensing) AltitudeUp to 10,000 feet (3,048 m) General EMCDesigned to carry CE mark (with immunity exception noted below) EmissionsEN-55011, 1991, Class B ImmunityEN-5

31、0082-1, 1995 SafetyEN-61010, 1993 in accordance with Council Directives 73/23/EEC and 93/68/EEC Calibration Cycle6 month. Performance before and performance after data to be supplied for units. 1%1% ACCURACYACCURACY BIRDModel 4027A Precision Power Sensors for Precision Process Applications Achieves

32、tighter, more consistent RF power measurements for improved yield. 1% accuracy at specified calibration frequencies and power levels. Direct, plug-in operation with the industry standard Bird Model 4421 RF Power Meter. Multiple sensors provide for measurement of 0.3 W - 10 kW over a 250 kHz - 170 MH

33、z frequency range. Birdsnew 4027A Series Power Sensors represent a family of sensors for use in semiconductor processing and other precision process applications. Intended for use with the industry standard BirdPrecision Laboratory Power Meter Model 4421, these products provide a threefold improveme

34、nt in long-term unit-to-unit accuracy. Model 4027A Power Sensor A4454.qxd 10/1/07 1:29 PM Page 11 Laboratory Grade Instruments www.bird- 1-866-695-4569 BirdElectronic Corporation 12 Model 4028 Power Sensor 4028 SERIES Power Sensor 4028A250K4028400K4028A2M4028A3M4028A4M4028A10M4028A25M4028B3M4028B10M

35、4028C10M Power Range1 kW - 20 kW1 kW - 25 kW500 W-50 kW Frequency250 - 400 kHz 400 - 550 kHz1.5 - 2.5 MHz2.5 - 3.5 MHz3.5 - 4.5 MHz10 - 15 MHz25 - 30 MHz2.5 - 4 MHz10 - 15 MHz10 - 15 MHz Accuracy 2% (1?) at calibration frequencies and power levels; 4% at other frequencies and power levels. Add 2% to

36、 uncertainty outside 25 10C VSWR Range1.0 to 2.0 (40.0 to 9.5 dB return loss) Directivity28 dB Insertion Loss 0.1 seconds add 0.1 W for D from 0.001 to 0.1 add 5% or reading for burst widths less than 1 s add 10% of reading for burst widths less than 0.5 s Wideband Power Sensor 13BirdElectronic Corp

37、oration 1-866-695-4569www.bird- Power Measurement Model 5012 Wideband Sensor and vDPM Software Sensor Characteristics - General Frequency Range350 MHz - 4 GHz Power Measurement Range0.15 W - 150 W average, 400 W peak Impedance50 ohm (nominal) Insertion Loss0.05 dB up to 1 GHz, 0.1 dB from 1 GHz to 4

38、.0 GHz Insertion VSWR1.05 up to 2.5 GHz, 100 MHz 800 ns min. Parameters26-99 MHz 1.5 s min. 2-25 MHz15 s min. Pulse Rep.Rate Peak15 pps min. Pulse Duty Factor1 x 10-4min. AccuracyTRUE AVERAGE POWER, 5% of reading (15C to 35C), 7% of reading (-10C to 50C) PEAK POWER, 8% of full scale Dynamic Range40:

39、1 (E.G. 50 W element measure 1.25 W to 50 W). Peak/Average 10 dB maximum with DPM elements Power Ratio Settling Time 2 seconds ConnectorsQC Type. Female N normally supplied. Insertion VSWR1.05:1 from 0.45 to 1000 MHz (with N connectors) Dimensions1.875 H x 1.875 W x 3.5 D (47.7 mm x 47.7 mm x 88.9 m

40、m) excluding connectors Weight1.12 lbs. (0.51 kg) Operating Temp.-10C to +50C Storage Temp.-40C to +75C Humidity95% max. (non-condensing) COMPATIBLE DEVICES 5000-EXDigital Power Meter SA-6000EXSite Analyzer,Antenna, repetition rate 30 pps and duty factor 1 x 104min. BatteryTwo 9-Volt alkaline transi

41、stor batteries AC Power120 VAC, 60 Hz or 220 VAC, 60 Hz (using Birdadapter) ConnectorsQC Type (Female N normally supplied) FinishLight Gray powder coat Nominal Size6 7/8 H x 5 1/8 W x 3 5/8 D, (includes connectors)(175 mm x 130 mm x 92 mm) Weight3 lbs. (1.4 kg) ElementsTables 1, 2, 3, 3A, 4, 5, 6 (p

42、ages 40-43) AccessoriesCase (page 46), spare batteries (page 45), extra QC connectors (page 44). MODEL 43P Portable Wattmeter PEAK POWER RETROFIT KIT 4300-400 Portable Wattmeter Power Range100 mW - 10 kW using BirdPlug-in Elements.* Frequency Range450 kHz - 2.7 GHz (depending on element) AccuracyCW

43、Mode: 5% full scale, Peak mode: 8% full scale ModulationNormal voice audio; or (Peak Mode) Rectangular Pulses Duty cycle: 2% (min), Repetition rate: 100 pps (min), Pulse width: 200 s (min) Battery Life48 hours typical WeightAdds 1 lb. to Model 43 HIGH-POWER WATTMETER 4305A Portable Wattmeter Power R

44、ange50 W - 25 kW using BirdPlug-in Elements.* Frequency Range450 kHz - 2.3 GHz (depending on element) Insertion VSWRwith N Connectors 1.05 max. Accuracy5% of full scale ConnectorsQC Type (Female N normally supplied) FinishGray powder coat Nominal Size6 5/16 H x 5 1/8 W x 4 1/4 D, (includes connector

45、s)(161 mm x 131 mm x 108 mm) Weight 3 1/4 lbs. (1.5 kg) Elements4305A element table below and 1 5/8AA table (page 42) AccessoriesCase (page 46) 4305A ElementsFrequency (MHz) Power.45-2.523050-125100-250400-10001100-1800 50 W50K7 2500 W2500B72500C72500E7 5000 W5000B7 10 kW10KH7 25 kW25KP7 VARIABLE RF

46、 TAP 4431 Portable Wattmeter Power and 5 kW max. 2 - 30 MHz, Frequency Range1 kW max. 30 - 1000 MHz* using BirdPlug-in Elements* Insertion VSWRwith N Connectors 1.07 max.* to 1000 MHz Accuracy5% of full scale Insertion Loss0.1 dB max. (2-512 MHz), 0.2 dB max. (512-1000 MHz)* RF Sample OutputVariable -15 to -70 dB from BNC (Female) port ConnectorsQC Type (Female N normally supplied) FinishGray powder coat Nominal Size6 7/8 H x 5 1/8 W x 3 5/8 D, (includes connectors)(175 mm x 130 mm x 92 mm) Weight3 1/2 lbs. (1.6 kg) ElementsTables 1, 2, 3, 3A, 4, 6 (pages 40-43) (within po