1、AVO INTERNATIONAL Archcliffe Road Dover Kent CT17 9ENTel: +44 (0) 1304 502100 EnglandFax:+44 (0) 1304 207342 510 Township Line Road Blue Bell PA 19422-2795Tel: +1 (215) 646-9200 U.S.A.Fax:+1 (215) 643-2670 4651 S.Westmoreland Road DallasTel: +1 (800) 723-2861 (U.S.A.only) TX 75237-1017Te l : +1 (214

2、) 330-3203 (Intern a t i o n a l ) U.S.A.Fax:+1 (214) 337-3038 MEGGERSA 29, Alle de Villemomble 93340 Le Raincy ParisTel: +33 (1) 43.02.37.54 FranceFax:+33 (1) 43.02.16.24 This instrument is manufactured in the European Union.The Company reserves the right to change the specifi cation or design with

3、out prior notice. MEGGER is the registered Trade Mark of AVO INTERNATIONAL LIMITED. This data uses the comma as the decimal marker to align with general European usage. CopyrightAVO INTERNATIONAL LIMITED. Part No 6172-215 Edition 1 - 2CC Repair and Warranty New instruments are guaranteed for 1 year

4、from the date of purchase by the User. Any unauthorized prior repair or adjustment will automatically invalidate the Warranty. Instrument Repair and Spare Parts For service requirements for MEGGER Instruments contact :- AVO INTERNATIONAL orAVO INTERNATIONAL Archcliffe Road 510 Township Line Road Dov

5、er Blue Bell Kent, CT17 9ENPA 19422-2795 EnglandU.S.A. Tel: +44 (0) 1304 502243Tel: +1 (215) 646-9200 Fax:+44 (0) 1304 207342Fax:+1 (215) 643-7215 or an approved repair company. Avo Megger FlexiClamp 200 28/5/99 11:24 am Page 1 RadioFans.CN 收音机爱 好者资料库 MEGGERFlexiClamp 200 User Guide THEINSTRUMENTMUS

6、T ONLY BEUSED BYTRAINED AND COMPETENTPERSONS Symbols used on the instrument Caution:refer to accompanying notes. Equipment protected throughout by Double Insulation (Class II) Equipment complies with relevant EU Directives SAFETY WARNINGS The section of wire under test must be clean, free of debris,

7、 and undamaged. Measurements beyond maximum selected range must not be taken. When taking measurements above 30 V RMS, extreme care must be taken, with the hand kept behind the hand guard. Do not use on uninsulated conductors at a voltage greater than 1000 V. Do not operate the instrument with the b

8、attery cover removed. Do not operate the instrument if any part of it is damaged. Do not operate the instrument in environments subject to high temperature, damp, humidity or excessive vibration. Safety Warnings must be read and understood before the instrument is used, and observed during use. The

9、FlexiClamp 200 is a rugged lightweight clamp meter, fo r measuring a.c current to 40 Amps in 2 or 3 wire, round or fl at cables without the need to break the circuit, separate the cores, or remove equipment covers. Current in single core cables can be measured to 199,9 Amps. O p e r a t i o n 1.Set

10、the 2 position slide switch to select Single or Multi-wire cable. 2.D e t e rmine the cable Ty p e, and set the rotary switch to the appropriate position. For single core cables select the single wire position. 3.Press the jaw opening lever to open the jaws. Fit the jaws squarely around the cable sh

11、eath and in line with the cable. 4.Align the cable in the shoulder slot between the jaws, and release the trigger to close the jaws on the cable. Avo Megger FlexiClamp 200 28/5/99 11:25 am Page 2 RadioFans.CN 收音机爱 好者资料库 Features and Controls Jaw Opening lever 5. When measuring the current in a fl at

12、 cable, the cable must be positioned as follows: The proximity of other current carrying conductors may affect the reading. Keeping a minimum distance of 125mm (5”) from these conductors will minimise this. 6.Read the current directly from the display. The Hold button holds the reading on all ranges

13、. Auto Shut Off To conserve battery power, the Auto Shut Off turns off the instrument after approximately 3 minutes. The instrument can be switched back on by turning the rotary switch to Off and then On again. Amps Cable Type selection Data Hold push Battery Compartment cover Tactile Hand guard Mul

14、tiwire Single Wire Selector Shoulder slot RadioFans.CN 收音机爱 好者资料库 Specifi cation Measuring Ranges: Single wire mode0 to 199,9 Amp 2-or-3-wire mode0 to 40,0 Amp Resolution:0,1 Amp. Accuracy:At 22C (72F) and rated frequency Single wire2% of reading 2 digits 2-or-3-wire mode Flat or Twin cable5% of rea

15、ding 2 digits. Round Cable12% of reading 2 digits. Calibration at 12 month intervals is recommended Temperature Range:-0 - 40C (32F - 104 F) Humidity Range:0% to 95% RH Power Supply:1 x PP3 - 9V battery (IEC 6LR61 type) Battery life:Typically 50 hours continuous use or 20 weeks of normal daily use.

16、L ow Battery Indicator:when battery voltage falls below 7 V.Remove the battery if the instrument is likely to remain unused for an extended period of time. Battery Replacement:The battery cover can be released by the insertion of a screw-driver (as shown below).Lever up and remove the battery cover.

17、 Replace the exhausted battery, and slide the cover on securely. To replace SLIDE into position Safety: The instruments meet the requirements for double insulation to IEC 1010-2-032, EN61010-2-032 to Category I I I*, 1000 Volts on insulated cable. (*Relates to transient overvoltage likely to be foun

18、d in fi xed installation wiring). E.M.C:The instrument meets EN 50081-1 and EN 50082-1 (1992) Case Dimensions:110mm x 229mm x 45mm (413”x 9”x 134”) Max.Jaw Opening:25,4mm (1”) Weight:315g (11oz) including batteries Cleaning:Wipe disconnected instrument with a clean cloth damped with soapy water or Isopropyl Alcohol (IPA). Accessories SuppliedPart Number User Guide6172-215 Carrying pouch with belt loop8101-101 Avo Megger FlexiClamp 200 28/5/99 11:25 am Page 4