1、OPERATING INSTRUCTIONS DIGITAL POWER METER MODEL 5000 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 INSTRUCTION BOOK DIGITAL POWER METER MODEL 5000 AND POWER SENSORS MODELS 5010, 5011, AND 5011-EF Copyright 2003 by Bird Electronic Corporation Instruction Book P/N 920-5000S Rev. E. THRULINE is a Re

2、gistered Trademark of Bird Electronic Corporation Microsoft and Windows are registered trademarks of the Microsoft Corporation RadioFans.CN 收音机爱 好者资料库 I am not blank i Safety Precautions The following are general safety precautions that are not necessarily related to any specific part or procedure,

3、and do not necessarily appear elsewhere in this publication. These precautions must be thoroughly understood and apply to all phases of operation and maintenance. Keep Away From Live Circuits Operating personnel must at all times observe normal safety regulations. Do not replace components or make a

4、djustments inside the equipment with high voltage turned on. To avoid casualties, always remove power. Shock Hazard Do not attempt to remove the RF transmission line while RF power is present. Radiated RF power is a potential health hazard. Do Not Service or Adjust Alone Under no circumstances shoul

5、d any person reach into an enclosure for the purpose of service or adjustment of equipment except in the presence of someone who is capable of rendering aid. Chemical Hazard Dry cleaning solvents for cleaning parts may be potentially dangerous. Avoid inhalation of fumes or prolonged contact with ski

6、n. Bird Model 5000 Digital Power Meter ii Safety Earth Ground An uninterruptible earth safety ground must be supplied from the main power source to test instruments. Grounding one conductor of a two conductor power cable is not sufficient protection. Serious injury or death can occur if this groundi

7、ng is not properly supplied. Resuscitation Personnel working with or near high voltages should be familiar with modern methods of resuscitation. Safety Symbols The caution symbol appears on the equipment indicating there is important information in the instruction manual regarding that particular ar

8、ea. ?NOTE: Calls attention to supplemental information WARNING Warning notes call attention to a procedure which, if not correctly performed, could result in personal injury. CAUTION Caution notes call attention to a procedure which, if not correctly performed, could result in damage to the instrume

9、nt. iii Warning Statements The following safety warnings appear in the text where there is danger to operating and maintenance personnel, and are repeated here for emphasis. Caution Statements The following equipment cautions appear in the text whenever the equipment is in danger of damage, and are

10、repeated here for emphasis. WARNING Never attempt to connect or disconnect RF equipment from the transmission line while RF power is being applied. Leaking RF energy is a potential health hazard. WARNING Disconnect from external power before any disassembly. The potential for electric shock exists.

11、CAUTION When connecting the TPS, only turn the connector nut. Damage may occur if torque is applied to the sensor body. CAUTION Ground all instruments before connecting the TPS. Electric shock could damage the sensor. CAUTION Use a Bird adapter only and do not use the adapter with the batteries remo

12、ved. Bird Model 5000 Digital Power Meter iv Safety Statements USAGE ANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY THE MANUFACTURER MAY IMPAIR THE INSTRUMENTS SAFETY PROTECTION. USO EL USO DE ESTE INSTRUMENTO DE MANERA NO ESPECIFICADA POR EL FABRICANTE, PUEDE ANULAR LA PROTECCIN DE SEGURIDA

13、D DEL INSTRUMENTO. CAUTION Do not exceed 2 W average or 125 W peak power for 5 s when using the TPS or TPS-EF. Doing so will render the sensor inoperative. CAUTION Harsh or abrasive detergents and some solvents can damage the display unit and information on the labels. CAUTION Always turn off the DP

14、M before connecting or disconnecting a sensor. CAUTION Replace only with Ni-MH rechargeable A batteries. Nominal Voltage 1.2V; Capacity 2700mAhr. v BENUTZUNG WIRD DAS GERT AUF ANDERE WEISE VERWENDET ALS VOM HERSTELLER BESCHRIEBEN, KANN DIE GERTESICHERHEIT BEEINTRCHTIGT WERDEN. UTILISATION TOUTE UTIL

15、ISATION DE CET INSTRUMENT QUI NEST PAS EXPLICITEMENT PRVUE PAR LE FABRICANT PEUT ENDOMMAGER LE DISPOSITIF DE PROTECTION DE LINSTRUMENT. IMPIEGO QUALORA QUESTO STRUMENTO VENISSE UTILIZZATO IN MODO DIVERSO DA COME SPECIFICATO DAL PRODUTTORE LA PROZIONE DI SICUREZZA POTREBBE VENIRNE COMPROMESSA. SERVIC

16、E SERVICING INSTRUCTIONS ARE FOR USE BY SERVICE - TRAINED PERSONNEL ONLY. TO AVOID DANGEROUS ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING UNLESS QUALIFIED TO DO SO. SERVICIO LAS INSTRUCCIONES DE SERVICIO SON PARA USO EXCLUSIVO DEL PERSONAL DE SERVICIO CAPACITADO. PARA EVITAR EL PELIGRO DE DESCARGAS

17、ELCTRICAS, NO REALICE NINGN SERVICIO A MENOS QUE EST CAPACITADO PARA HACERIO. Bird Model 5000 Digital Power Meter vi WARTUNG ANWEISUNGEN FR DIE WARTUNG DES GERTES GELTEN NUR FR GESCHULTES FACHPERSONAL. ZUR VERMEIDUNG GEFHRLICHE, ELEKTRISCHE SCHOCKS, SIND WARTUNGSARBEITEN AUSSCHLIELICH VON QUALIFIZIE

18、RTEM SERVICEPERSONAL DURCHZUFHREN. ENTRENTIEN LEMPLOI DES INSTRUCTIONS DENTRETIEN DOIT TRE RSERV AU PERSONNEL FORM AUX OPRATIONS DENTRETIEN. POUR PRVENIR UN CHOC LECTRIQUE DANGEREUX, NE PAS EFFECTUER DENTRETIEN SI LON NA PAS T QUALIFI POUR CE FAIRE. RF VOLTAGE MAY BE PRESENT IN RF ELEMENT SOCKET - K

19、EEP ELEMENT IN SOCKET DURING OPERATION. DE LA TENSION H.F. PEAT TRE PRSENTE DANS LA PRISE DE LLMENT H.F. - CONSERVER LLMENT DANS LA PRISE LORS DE LEMPLOI. HF-SPANNUNG KANN IN DER HF-ELEMENT- BUCHSE ANSTEHEN - ELEMENT WHREND DES BETRIEBS EINGESTPSELT LASSEN. PUEDE HABER VOLTAJE RF EN EL ENCHUFE DEL E

20、LEMENTO RF - MANTENGA EL ELEMENTO EN EL ENCHUFE DURANTE LA OPERACION. IL PORTAELEMENTO RF PU PRESENTARE VOLTAGGIO RF - TENERE LELEMENTO NELLA PRESA DURANTE IL FUNZIONAMENTO. vii About This Manual This instruction manual guides users through the operation and maintenance of the Bird 5000 Digital Powe

21、r Meter (DPM), as well as the Bird 5010 Directional Power Sensor (DPS) and Bird 5011 and 5011-EF Terminating Power Sensors (TPS). Typography There are two types of keys on the DPM. A hard key has a specific function which is indicated on the key. The key names for hard keys are set in bold typeface,

22、 e.g. Press the ON key. Speed keys, which appear under the display, have a different label depending upon the function selected. The names appear at the bottom of the display, directly above the corresponding key. The key names for speed keys are set in bold italic typeface, e.g. Press the SCALE Key

23、. In this manual, speed keys will also be referred to by number, with speed key 1 being the key on the left. Figure 2 on page 2 shows these speed key numbers. Chapter Layout Introduction Identifies the parts of the DPM, describes the functions of the various keys, and explains the meaning of the ind

24、icators which may be displayed. Also lists the items supplied and optional equipment available. Installation Gives directions for connecting the DPM, and discusses the various power sources. Bird Model 5000 Digital Power Meter viii Operation Explains how to make measurements with the DPM, and the sp

25、ecial functions used with specific sensors. Maintenance Lists routine maintenance tasks for the Digital Power Meter, and troubleshooting tips for common problems. Specifications and battery information are also included. Changes to this Manual We have made every effort to ensure this manual is accur

26、ate at the time of publication. If you should discover any errors or if you have suggestions for improving this manual, please send your comments to our factory. This manual may be periodically updated, when inquiring about updates to this manual refer to the part number and revision level on the ti

27、tle page. ix Table of Contents Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . i About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . .vii Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Items Supplied . . . . . . . . . . .

28、. . . . . . . . . . . . . . . . . .1 Component Description . . . . . . . . . . . . . . . . . . . . . .2 Display Description . . . . . . . . . . . . . . . . . . . . . . . . .4 Speed Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Indicators . . . . . . . . . . . . . . . . . . . .

29、. . . . . . . . . . . . .6 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Optional Equipment . . . . . . . . . . . . . . . . . . . . . . . . .7 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Power Supply. . . . . . . . . . . . . . . .

30、 . . . . . . . . . . . . . .9 DPM Connection . . . . . . . . . . . . . . . . . . . . . . . . . .11 RF Connections . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Directional Power Sensor (DPS) . . . . . . . . . . .11 Terminating Power Sensor (TPS) . . . . . . . . . .12 Operation. . . . . . .

31、 . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Normal Operation. . . . . . . . . . . . . . . . . . . . . . . . . .13 Loading Setups . . . . . . . . . . . . . . . . . . . . . . . .14 Directional Power Sensor . . . . . . . . . . . . . . . . . . .14 Setting Forward Scale. . . . . . . . . .

32、. . . . . . . . .14 Terminating Power Sensor . . . . . . . . . . . . . . . . . .15 Zeroing Sensor . . . . . . . . . . . . . . . . . . . . . . . .15 TPS-EF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Clean

33、ing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Charging Batteries . . . . . . . . . . . . . . . . . . . . . . . . .17 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . .18 x Battery Replacement . . . . . . . . . . . . . . . . . . . . . . .20 Customer Service

34、. . . . . . . . . . . . . . . . . . . . . . . . . .21 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Attenuators do not require elements. The Bird 5011 frequency range is 40 MHz 4 GHz. The 5011-EF frequency range is 40 MHz 12 GHz. Includes interface cable. Automobile Ci

35、garette Lighter Adapter (P/N 5A2238-1) Connects the DPM to a standard 12V automotive cigarette lighter jack. Soft Carry Case (P/N 5000-030) Convenient and protective. Cutouts allow for operation without removal from the case. Hard Carry Case (P/N 5000-035) Protective case holds DPM, sensor, and acce

36、ssories. Attenuators Windows 95 or later, 2 MB free hard disk space; VGA monitor, open Com port. Includes interface cable. Serial to USB Adapter (P/N DC-DB9-U) Converts the serial cable to USB. Lets the DPM be connected to a PCs USB port if the serial port is unavailable. 9 Chapter 2Installation Pow

37、er Supply The DPM uses a rechargeable Nickel-Metal Hydride battery pack. Charge life is a minimum of 100 hours continuous usage. “Low Bat” is displayed when the batteries require charging. ?NOTE: For optimum battery life, charge the batteries only after “Low Bat” is displayed. The DPM can use an ext

38、ernal power source. Using the DPM with the ac adapter or the 12V cigarette lighter adapter will also charge the battery. Charging time from full discharge is 8 hours using the ac adapter. When using the cigarette lighter adapter, charge time will depend on the car battery charge. ? AC Mains Adapter

39、To use the ac adapter. insert the adapters barrel connector into the DPMs external dc connector (See Figure 2 on page 2). Insert the adapter plug into a wall receptacle. ? Automobile Cigarette Lighter Adapter Insert the adapters barrel connector into the DPMs external dc connector. Insert the adapte

40、r plug into a cigarette lighter jack. CAUTION Use a Bird adapter only and do not use the adapter with the batteries removed. Bird Model 5000 Digital Power Meter 10 Figure 4 DPM Connections Installation 11 DPM Connection Although unlikely, it is possible to corrupt the power sensor firmware by connec

41、ting it to the DPM while the DPM is on. To prevent this, always turn the DPM off before connecting or disconnecting a sensor. Connect the power sensor to the “Sensor” port on the DPM using the sensor cable provided. If you are using the optional PCTool software, connect the PCs serial port to the “R

42、S-232” port on the DPM. RF Connections Directional Power Sensor (DPS) Connect the DPS to the RF line so that the arrow on the DPS points towards the load. The element in the forward socket should be inserted with its arrow pointing in the direction of forward power, as shown below. The reflected ele

43、ment should point in the direction of reverse power. The forward elements power rating must be 10 x the reverse elements rating. CAUTION Always turn off the DPM before connecting or disconnecting a sensor. WARNING Never attempt to connect or disconnect RF equipment from the transmission line while R

44、F power is being applied. Leaking RF energy is a potential health hazard. Bird Model 5000 Digital Power Meter 12 Terminating Power Sensor (TPS) RF connections are the same for the TPS-EF and the TPS. In most cases, the TPS should be connected to an attenuator or a directional coupler. For example, t

45、o measure a transmitter with power output between 0.1 and 50 Watts, use a 40 dB, 50 Watt attenuator. Insert the attenuator between the TPS and the RF source. Only connect the TPS directly to the source if the RF power will be less than 10 mW. Figure 5 DPS Element Orientation CAUTION Ground all instr

46、uments before connecting the TPS(-EF). Electric shock could damage the sensor. CAUTION When connecting the TPS or the TPS-EF, only turn the connector nut. Damage may occur if torque is applied to the sensor body. CAUTION Do not exceed 2 W average or 125 W peak power for 5 s when using the TPS or the

47、 TPS-EF. Doing so will render the sensor inoperative. 13 Chapter 3Operation The Bird Digital Power Meter is very easy to operate. Once a sensor is connected, turn the DPM on and take a reading. Additional commands are available, depending on the sensor used. Normal Operation ? Connect the sensor. ?

48、Turn on the DPM. ? Set the measurement units by pressing FWD Units and RFL Units. ? If you know the system loss or are using an attenuator, add the losses (in dB) of all components in the system. For attenuators and other frequency- dependent components, use the loss at the measured frequency. Then,

49、 press OFFSET and enter the total loss in dB. This will allow you to read the actual line power. The DPM accepts offsets from 0 to 100 dB. ? Turn on the RF source. ? Read the power level on the display. ?NOTE: The analog bar graph will respond immedi- ately to changes in the RF power. The major and minor displays will respond after a delay of 1 to 13 seconds, depending on the power level. Bird Model 5000 Digital Power Meter 14 Loading Setups When used with the optional PCTool software, setups can be stored in the DPM. Loading a setup will set the forward scale (f