《FLUKE 16 Instruction Sheet 电路图.pdf》由会员分享,可在线阅读,更多相关《FLUKE 16 Instruction Sheet 电路图.pdf(16页珍藏版)》请在收音机爱好者资料库上搜索。
1、Model 16 English Instruction Sheet Page 1 16 Multimeter with Temperature Instruction Sheet P Read First: Safety Information To ensure that the meter is used safely, follow these instructions: Do not use the meter if the meter or test leads appear damaged, or if you suspect that the meter is not oper
2、ating properly. Disconnect the live test lead before disconnecting the common test lead. When using the probes, keep your fingers behind the finger guards on the probes. Do not use the VCheck mode to measure voltages in circuits that could be damaged by this modes low input impedance (2 k). Turn off
3、 power to the circuit under test before cutting, desoldering, or breaking the circuit. Small amounts of current can be dangerous. Do not apply more than 600V rms between a meter terminal and earth ground. Use caution when working with voltages above 60V dc or 30V ac rms. Such voltages pose a shock h
4、azard. PN 643657 June 1997 Rev.2, 3/98 1997, 1998 Fluke Corporation. All rights reserved. Printed in U.S.A. RadioFans.CN 收音机爱 好者资料库 Model 16 English Instruction Sheet Page 2 Symbols Press button. Press button to switch between modes. Double insulation. Manual ranging mode. ip14i.eps Automatic Range
5、Selection The meter defaults to autoranging when you turn it on. The 4000 mV range can be entered only with manual range selection. Manual Range Selection 16MULTIMETER OFF 600V COM CAT + To return to autoranging, press for 2 seconds, or change the measurement mode. ip15i.eps Battery Saver If the met
6、er is ON but inactive and not connected to voltage for more than 45 minutes, the display goes blank to preserve battery life. To resume operation, press any button. Battery Saver is disabled in MIN/MAX record mode. RadioFans.CN 收音机爱 好者资料库 Model 16 English Instruction Sheet Page 3 AC and DC Voltage A
7、lso refer to VCheck. Volts ACVolts DC Input Impedance 5 MInput Impedance 10 M 50 Hz to 400 Hz 16MULTIMETER OFF V 600V COM CAT + AC / DC DCAC 4000 mV 4V 40V400V600V 16MULTIMETER OFF V 600V COM CAT + AC / DC ip01i.eps Resistance and Continuity eR Turn off circuit power before testing. Also refer to VC
8、heck. ResistanceContinuity 16MULTIMETER OFF 600V COM CAT + A TEMPERATURE VCheck 16MULTIMETER OFF 600V COM CAT + A TEMPERATURE VCheck 1000 F (10% + 90) typical ?2.000V0.001V(1.9% + 2) 2 1. The 4000 mV range can be entered only in manual range mode. Use the 4000 mV range with accessories. 2. The beepe
9、r is guaranteed to come on at 250. The meter detects opens or shorts 250 s. Model 16 English Instruction Sheet Page 14 FunctionRangeResolutionAccuracyBurden Voltage (50 Hz to 400 Hz) 0 to 200 A0.1 A(2% + 3 counts)5 mV/A 0 to 200 A0.1 A(1% + 2 counts)5 M 2 k 10M 2 k 60 dB at dc 50 or 60 Hz ?600V rms1
10、00 dB at dc, 50 or 60 Hz50 dB at 50 Hz or 60 Hz Open Circuit Test Voltage Full Scale Voltage To 4.0 M 40 M ? 600V rms1.5V dc450 mV dc1.5V dc ?600V rms2.4-3.0V dc2.400V dc Short Circuit Current ?600V rms300 k at 600V. MIN MAX Recording Accuracy and Response Time Specified accuracy of the measurement
11、function 12 digits in dc for changes 200 ms in duration (40 digits in ac). Typical 100 ms response to 80%. Example 1: This would mean 1.2 when recording temperature. Example 2: This would mean 12 A when recording A or 12A if used with a dc amp probe (with a mV input). Model 16 English Instruction Sh
12、eet Page 15 MIN MAX Recording with Elapsed Time Elapsed TimeResolutionAccuracy 0 to 100 hours (99:59)1 minute0.3% typical Maximum Voltage Between any Terminal and Earth Ground:600V rms Display:3 3/4-digits, 4000 counts, updates 4/sec Operating Temperature:-10C to 50C (14F to 122F) Storage Temperatur
13、e:-30C to 60C (-22F to 140F) indefinitely (to -40C (-40F) for 100 hrs) Temperature Coefficient: (.1 x specified accuracy)/C (28C) Relative Humidity:0% to 90% (-10C to 35C; 14F to 95F) 0% to 70% (35C to 50C; 95F to 122F) Battery Type:9V, NEDA 1604 or IEC 6F22 Battery Life:650 continuous hours with al
14、kaline 450 continuous hours with carbon-zinc Shock, Vibration:3 meter drops. Size (H x W x L):3.46 cm x 7.05 cm x 14.23 cm (1.35 in x 2.75 in x 5.55 in) Weight:286g (10 oz) Safety:Designed to Protection Class II requirement of UL1244, ANSI/ISA-S82, CSA C22.2 No 231, and VDE 0411, and IEC 1010 overvo
15、ltage Category III (CAT III, 600 Volts). EMI Regulations:Complies with FCC Part 15, Class B, and VDE 0871B. Trademark of TV Product Services. Complies with EN 61010-1: 1993. Certifications: TUV, UL and VDE pending Model 16 English Instruction Sheet Page 16 LIMITED WARRANTY & LIMITATION OF LIABILITY
16、Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is three years and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or
17、end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Flukes opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate subst
18、antially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused produc
19、ts to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Bu
20、yer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Flukes warranty obligation is limited, at Flukes option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is retu
21、rned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized service c
22、enter. Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will p
23、rovide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYERS SOLE
24、AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOS
25、S OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of
26、 this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Fluke CorporationFluke Europe B.V. P.O. Box 9090P.O. Box 1186 Everett WA5602 B.D. Eindhoven 98206-9090The Netherlands 5/94