《Biddle MLS2000_UG 电路图.pdf》由会员分享,可在线阅读,更多相关《Biddle MLS2000_UG 电路图.pdf(121页珍藏版)》请在收音机爱好者资料库上搜索。
1、Optical Power Meter MEGGER MLS2000 User Guide Guide de lutilisateur Benutzerhandbuch Guida per lutente Gua del Usuario Gebruikersgids Anvndarmanual Brugervejledning Brukerhndbok Kyttohjeet MEGGER RadioFans.CN 收音机爱 好者资料库 2 Contents Introduction3 User Controls and Display4 Operation5 Batteries6 Specif
2、i cation7 Accessories8 Care and Maintenance8 Repair and Warranty9 Symbols used on the Instrument are: Caution: refer to accompanying notes. Equipment complies with relevant EU Directives. Warning: Laser Radiation RadioFans.CN 收音机爱 好者资料库 SAFETY WARNINGS This instrument is designed for testing fi bre
3、optic installations and so meets the safety requirements of IEC 60825-1: 1994 (including amendment A11: 1996) and IEC 60825-2: 1995 (including amendment A1: 1998). This products output levels are within the Accessible Emission Limits (AEL) for a Class 1 Laser Product and so does not generate any opt
4、ical hazards internally. However it can be used to test optical fi bres in environments where light sources that would cause an optical hazard could be present. This corresponds to working within the AEL for Class 1, Class 2, Class 3A and Class 3B lasers, therefore, please take note of the following
5、 safety warnings: Under no circumstances should a connector end-face, prepared optical fi bre or fractured optical fi bre be viewed directly unless the power received from the fi bre is known to be safe (as defi ned by IEC 60825) and under local control. AVOID EXPOSURE TO BEAM if the accessible radi
6、ation is within the AEL for Class 3B lasers. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS if the accessible radiation is within the AEL for Class 3A lasers. DO NOT STARE INTO BEAM if the accessible radiation is within the AEL for Class 2 lasers. The instrument should not be used
7、if any part of it is damaged. Refer to operating instructions for further explanation and precautions. Safety Warnings and Precautions must be read and understood before the instrument is used. They must be observed during use. NOTE: THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT
8、 PERSONS. RadioFans.CN 收音机爱 好者资料库 4 Introduction Thank you for purchasing this quality AVO product. Before attempting use of your new instrument please take the time to read this user guide, ultimately this will save you time, advise you of any precautions you need to take and could prevent damage t
9、o yourself and the instrument. The MLS2000 is a stable optical dual Laser source that can be used in conjunction with an optical power meter for optical loss testing of fi bre optic cables. It has been pre-calibrated to output 1310 nm or 1550 nm respectively for an output level of 6 dBm into a 9/125
10、 single-mode fi bre. 5 1.0 User Controls and Display 1.1 On /Off Switch To turn the unit on, depress the ON/OFF switch. The unit defaults to CW (Continuous Wave) and 1310 nm output on power up, this is indicated by the CW and the 1310 nm LED illuminating. To turn the unit off, depress the ON/OFF swi
11、tch again. 1.2 CW / MOD Switch Used to select the Laser output to either CW or 1 kHz modulation. Selection is indicated by the illumination of the appropriate LED. To change back to previous mode, depress the CW/MOD switch again. 1.3 Wavelength () Switch To select the 1550 nm laser, depress the lamb
12、da switch. Selection is indicated by the illumination of the 1550 nm LED. To change back to the 1310 nm laser output, depress the switch again. Selection is indicated by the illumination of the 1310 nm LED 1.4 LO BATT LED This LED illuminates when the internal alkaline batteries require replacement
13、or NiCd/NiMH batteries require recharging. 1.5 CHARGE LED This LED illuminates when the external Mains adapter is connected to the source indicating that the rechargeable batteries are on charge. See section 3.0 for details. 6 2.0 Operation This instrument can be used in conjunction with an optical
14、power meter for multiple applications including Optical Loss Testing, Optical Continuity Testing, Acceptance Testing of Fibre Transmitters and Received Power Testing of optical receivers. There are multiple techniques to achieve these types of tests, but a typical procedure is detailed below: 2.1 Op
15、tical Loss Testing Take an optical light source and power meter with appropriate patch cords and mating adapter (uniter) to match the optical fi bre under test. Clean all the connectors and connect the light source via the fi rst patch cord, the uniter and the second patch cord to the power meter so
16、 the attenuation of both cords can be eliminated. The link to be tested is then inserted between them so the optical loss associated only with this link can be found. This test is normally repeated multiple times with the interconnections between the patch cord and the fi bre under test disconnected
17、 and reconnected before each time and an average result taken to ensure repeatability and stability. 2.2 Optical Continuity Testing Use an optical light source (of a known output power) and power meter with patch leads of a known optical loss and a uniter matched to the optical fi bre under test. Cl
18、ean all the connections and insert the link to be tested between the light source and the power meter. Measure the output of the light source through the fi bre under test and check that it is above a pre- determined power level. This is a more simple go, no go test. 2.3 Acceptance Testing of Fibre
19、Transmitters Use a power meter with a suitable dynamic range for the transmitter under test and patch leads of a known optical loss. Clean all the connections and connect the power meter to the transmitter via the patch cord. Turn on the transmitter and allow the output to stabilise before measuring
20、 the output and comparing the result to an acceptance standard or versus historical data. This test is normally repeated multiple times with the interconnections disconnected and reconnected before each time and an average result taken to ensure repeatability and stability. 2.4 Received Power Testin
21、g Use a power meter with a suitable dynamic range for the receiver under test and an adapter to match the connections on the receiver. Clean all the connections and connect the power meter to the fi bre supplying the receiver under test so that the power meter is now where the receiver would normall
22、y go. Turn on the optical transmitter of the fi bre system and allow the output to stabilise before measuring the output at the receiver and comparing the result to the input specifi cations of the receiver. This test is 7 normally repeated multiple times with the interconnections disconnected and r
23、econnected before each time and an average result taken to ensure repeatability and stability. The MLS2000 is supplied and confi gured for use with a 2 LR6 (AA) dry cells. A 12V DC charger (See Optional Accessories) can be used as a dual power source; this will not apply a charge to the dry cells wh
24、ile fitted. Alternatively, within the battery compartment there is a switch to change the battery type from alkaline to NiCd/NiMh. If the DC charger is now connected to the instrument with rechargeable batteries in it (the switch is set to NiCd/NiMh) then the batteries will start to recharge. Allow
25、14 16 hours to fully charge a rechargeable battery. Do NOT attempt to recharge alkaline cells, over heating would occur and the instrument may be damaged. When the switch is set to NiCd/NiMh, only fi t rechargeable cells. 3.0 Batteries 8 4.0 Specifi cation 4.1 Optical Specifi cation Source Type:Dual
26、 Laser Wavelength:1310 nm and 1550 nm Wavelength Accuracy: 30 nm Output Waveform:CW or internally chopped 1k Hz Spectral FWHM:3 nm typically. Output Level:Typically -6 dBm into 9/125 Multimode fi bre Output Stability:Typically 0.05 dB over 1 hour 23C Stabilisation Time:Typically 30 seconds from powe
27、r up 23C 4.2 General Specifi cation Safety:This instrument is designed for testing fi bre optic installations and so meets the safety requirements of IEC 60825-1: 1994 (including amendment A11: 1996) and IEC 60825-2: 1995 (including amendment A1: 1998). This products output levels are within the Acc
28、essible Emission Limits (AEL) for a Class 1 Laser Product and so does not generate any optical hazards internally. EMC: Complies with Electromagnetic Compatibility Specifi cations BS/EN61326-1-1997 - Performance Criteria A (Light industrial - Class B) Batteries: 2 LR6 (AA), Manganese-alkali or nicke
29、l- cadmium or nickel-metal-hydride cells (For dry cells, the switch in the battery compartment must be set to Alkaline.) Battery Consumption: 40 mA nominal Power Down:Manual only. Case Dimensions:160mm x 83mm x 30mm Instrument Weight:220g Operational Temperature: -10C to +50C (14F to 122F) Operation
30、al Humidity: 95% at 40C (104F) Storage Temperature: -20C to 70C (-4F to158F) 9 Optional Accessories:Part No. Single Mode Patch Cord with FC / SC Connectors (1 metre)22440-007 Single Mode Patch Cord with FC / FC Connectors (1 metre)22440-008 Single Mode Patch Cord with FC / ST Connectors (1 metre)224
31、40-009 Single Mode Patch Cord with ST / ST Connectors (1 metre)22440-015 Single Mode Patch Cord with SC / SC Connectors (1 metre)22440-016 Multimode Patch Cord with FC / FC Connectors (1 metre)22440-010 Multimode Patch Cord with FC / ST Connectors (1 metre)22440-011 Multimode Patch Cord with FC / SC
32、 Connectors (1 metre)22440-012 Multimode Patch Cord with ST / ST Connectors (1 metre)22440-013 Multimode Patch Cord with ST / SC Connectors (1 metre)22440-014 Multimode Patch Cord with SC / SC Connectors (1 metre)22440-017 Multimode Patch Cord with ST / SMA 9mm Connectors (1 metre)22440-018 Multimod
33、e Patch Cord with FC / SMA 9mm Connectors (1 metre)22440-023 Multimode Patch Cord with SC / SMA 9mm Connectors (1 metre)22440-024 MPM Power Meter Adaptor with FC connector6220-715 MPM Power Meter Adaptor with ST connector6220-716 MPM Power Meter Adaptor with SC connector6220-717 In-line gender chang
34、ing adaptor with Multimode ST connectors22440-019 5.0 Accessories 5.0 Accessories (cont). In-line gender changing adaptor with Single mode SC connectors22440-020 In-line gender changing adaptor with Multimode SC connectors22440-021 In-line gender changing adaptor with Single mode ST connectors22440-
35、022 In-line gender changing adaptor with Single mode FC connectors22440-023 Bare Fibre adaptor SC connector25970-034 Bare Fibre adaptor FC connector25970-035 Bare Fibre adaptor ST connector25970-036 *Bare Fibre adaptor Single mode / Multimode body25970-037 UK DC Power Supply27900-050 USA DC Power Su
36、pply27900-051 EU DC Power Supply27900-052 Rechargeable Battery 25985-023 Included Accessories:Part No. User Guide6172-627 Test ceci ne chargera pas les piles sches lorsquelles sont utilises. Alternativement, dans le compartiment des piles se trouve un commutateur pour modifi er le type de piles dalc
37、alines en NiCd/NiMh. Si le chargeur en courant continu est maintenant connect linstrument avec des piles rechargeables (le commutateur est plac sur NiCd/NiMh), les piles commenceront alors se recharger. Il faut entre 14 et 16 heures pour entirement recharger une pile rechargeable. Nessayez pas de re
38、charger des piles alcalines, il se produirait une surchauffe et linstrument pourrait tre endommag. Lorsque linterrupteur est plac sur NiCd/NiMh, nemployer que des piles rechargeables. 22 4.0 Specifi cations 4.1 Spcifi cations optiques Type de source:Laser double Longueur donde:1310 nm et 1550 nm Prc
39、ision de longueur donde: 30 nm Forme donde de sortie: mode continu ou interrompu 1kHz Fwhm spectral: typiquement 3 nm Niveau de rendement: typiquement -6 dBm dans la fi bre mode simple 9/125 Stabilit de rendement: typiquement 0.05 dB au-del d 1 heure 23C Temps de stabilisation: en gnral 60 secondes
40、partir de la mise sous tension 23C 4.2 Spcifi cations Gnrales Scurit:Cet instrument est conu pour mesurer les installations fi bres optiques et rpond ainsi aux exigences de scurit de la CIE n 60825-1 de 1994 (y compris lamendement A11 de 1996) et n 60825-2 de 1995 (y compris lamendement A1 de 1998).
41、 Les niveaux de sortie de ce produit sont inclus dans les limites accessibles dmissions (AEL) pour un produit laser de catgorie 1 et ne produisent ainsi aucun risque optique en interne. CEM : Conforme aux Prescriptions de Compatibilit Electromagntique NF/EN61326-1-1997 Critres de Performance A (Indu
42、striel lger - Classe B) Piles: 2 LR6 (AA). Piles alcalines au manganse ou au nickel-cadmium ou aux hydrures mtalliques de nickel (pour les piles sches, le commutateur dans le compartiment des piles doit tre positionn sur alcaline.) Consommation des piles: nominal 40 mA Mise hors tension: manuelle un
43、iquement Dimensions du botier: 160 mm x 83 mm x 30 mm Poids de linstrument: 220g Temprature de fonctionnement: -10C +50C (14F 122F) Humidit de fonctionnement: 95% 40C (104F) Temprature de stockage: -20C 70C (-4F to158F) 23 5.0 Accessoires Accessoires en option:Numro de pice. Cordon de branchement Mo
44、de simple avec connecteurs FC / SC (1 mtre)22440-007 Cordon de branchement Mode simple avec connecteurs FC / FC (1 mtre)22440-008 Cordon de branchement Mode simple avec connecteurs FC / ST (1 mtre)22440-009 Cordon de branchement Mode simple avec connecteurs ST/ ST (1 mtre)22440-015 Cordon de branche
45、ment Mode simple avec connecteurs SC / SC (1 mtre)22440-016 Cordon de branchement Multimode avec connecteurs FC / FC (1 mtre)22440-010 Cordon de branchement Multimode avec connecteurs FC / ST (1 mtre)22440-011 Cordon de branchement Multimode avec connecteurs FC / SC (1 mtre)22440-012 Cordon de branc
46、hement Multimode avec connecteurs ST / ST (1 mtre)22440-013 Cordon de branchement Multimode avec connecteurs ST / SC (1 mtre)22440-014 Cordon de branchement Multimode avec connecteurs SC / SC (1 mtre)22440-017 Cordon de branchement Multimode avec connecteurs ST / SMA 9mm (1 mtre)22440-018 Cordon de
47、branchement Multimode avec connecteurs FC / SMA 9mm (1 mtre) 22440-023 Cordon de branchement Multimode avec connecteurs SC / SMA 9mm (1 mtre) 22440-024 Adaptateur de Mesureur de puissance MPM avec connecteur FC6220-715 Adaptateur de Mesureur de puissance MPM avec connecteur ST6220-716 Adaptateur de
48、Mesureur de puissance MPM avec connecteur SC6220-717 Adaptateur de changement de genre en ligne avec connecteurs ST Multimode22440-019 5.0 Accessoires Adaptateur de changement de genre en ligne avec connecteurs SC Mode simple22440-020 Adaptateur de changement de genre en ligne avec connecteurs SC Mu
49、ltimode22440-021 Adaptateur de changement de genre en ligne avec connecteurs ST Mode simple22440-022 Adaptateur de changement de genre en ligne avec connecteurs FC Mode simple22440-023 Connecteur SC dadaptateur Fibre nue25970-034 Connecteur FC dadaptateur Fibre nue25970-035 Connecteur ST dadaptateur Fibre nue25970-036 *Corps dadaptateur fi bre nue mode simple / multimode25970-037 Alimentation lectrique CC Royaume-Uni27900-050 Alimentation lectrique CC Etats-Unis27900-051 Alimentation lectrique CC Union Europenne27900-052