1、 M S1-5010 Diagnostic Insulation Tester User Guide RadioFans.CN 收音机爱 好者资料库 GSAFETY WARNINGS Safety Warnings and Testing Precautions must be read and understood before the instrument is used. They must be observed during use The circuit under test must be switched off, de-energised and isolated befor

2、e test connections are made. The test terminal panel and side recess panel must be kept in a dry, clean condition. Circuits must be discharged before disconnecting the test leads - Capacitive loads can be lethal. See Testing Precautions. Circuit connections must not be touched during a test. In cert

3、ain circumstances, break-down of the circuit under test may cause the instrument to terminate the test in an uncontrolled manner, possibly causing a loss of display and warning indications while the circuit remains energised. In this event, it is important that the circuit is discharged and the inst

4、rument is turned off, before touching any connections. Replacement fuses must be of the correct type and rating. The instrument should not be used if any part of it is damaged. Refer to Testing Precautions for further explanations and precautions. 2 Symbols used on the instrument GCaution: Refer to

5、accompanying notes. FRisk of electric shock. cEquipment complies with relevant EU Directives tEquipment protected throughout by Double Insulation (Class II). NOTE THE INSTRUMENT MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS. RadioFans.CN 收音机爱 好者资料库 Contents Safety Warnings 2 General De

6、scription4 Features and Controls 5 Battery or Mains Operation6 Mains supply re-charging 6 12 V supply re-charging 6 Battery Charging Notes 6 Setting up procedures 7 Setup Language 7 Setup IR, SV and DD Tests 7 Setup PI Tests 7 Disable a Test Mode 8 Enable a Test Mode 8 Delete Stored Test Results 9 S

7、et / Reset Date and Time 9 Set / Reset Printer Baud rate 10 Set / Reset PC Baud rate 10 Setup / Reset Power On code 10 Setup / Reset Setup code 11 Set / Reset Date format 11 Set / Reset Current limit 11 Set / Reset Data Output Rate 11 Set / Reset Locking test button 12 Operation 13 Testing Precautio

8、ns 13 Performing tests - General 14 Using the Filter 15 Fault Conditioning (Burn) 16 Remote Operation 16 Test Mode Summary 17 Insulation Resistance Testing 17 Polarization Index Testing 17 Dielectric discharge Testing 18 Step Voltage Testing 18 Fault Conditioning (Burn) 19 Data Retrieve20 Display st

9、ored Test results 20 Download stored Test results to a printer 20 Downloading Test results to a PC 20 Application Notes 21 Preventive Maintenance 21 Insulation testing concepts 22 Test Techniques 23 Using the Guard terminal 23 Measurements above 100 G23 Circuit block diagram 24 Calibration Check 24

10、Appendix 125 Specification26 Accessories27 Repair and Warranty28 3 RadioFans.CN 收音机爱 好者资料库 The S1-5010 is an advanced insulation tester for all types of electrical equipment offering measurement capability up to several T. The instrument performs automatic tests, enabling consistent operation withou

11、t operator input, stores results and can be operated from a PC. Flexible power supply options and robust, portable construction allow the instrument to be used in a wide variety of applications. It is particularly suitable for analyzing the insulation of large machines, HV generators and cables. Whe

12、n turned On, voltage in excess of 50 volts across the + and - terminals will be indicated on the display, together with the flashing HV symbols. Switchable filtering allows stable readings to made when in the presence of high levels of 50 Hz or 60 Hz interference. P P P Po o o ol l l la a a ar r r r

13、i i i iz z z za a a at t t ti i i io o o on n n n I I I In n n nd d d de e e ex x x x and D D D Di i i ie e e el l l le e e ec c c ct t t tr r r ri i i ic c c c D D D Di i i is s s sc c c ch h h ha a a ar r r rg g g ge e e e tests are performed automatically, and test duration and voltages can be ad

14、justed according to user preference for these tests. A S S S St t t te e e ep p p p V V V Vo o o ol l l lt t t ta a a ag g g ge e e e test can also be performed automatically, with a voltage of 2500 V or 5000 V and a fixed test duration of 5 minutes. It is also possible to restrict operation to user

15、 defined voltages, to disable the graph plotting or to disable certain types of tests. This is all done using the S S S Se e e et t t tu u u up p p p screen. The settings can be security code protected. It is also possible to set a general security code to prevent unauthorized use of the instrument.

16、 The S1-5010 can be powered from the main supply, or by the its own internal rechargeable battery which provides for at least 8 hours of continuous testing. The battery symbol ,in the bottom left of the display indicates battery capacity. Connecting power to the supply connector, or to the 12 volt c

17、onnector in the side recess panel will automatically charge the battery whether the instrument is switched O O OOn n n n or O O OOf f f ff f f f. A high level of internal isolation allows the S1-5010 to be used while the battery is being recharged. An internal battery management system switches the

18、instrument off after ten minutes of inactivity. Test results and settings will not be lost when the instrument is switched off. Test results are stored internally but the RS232 connection allows an external computer to receive results in real time or to receive results previously stored. Safe testin

19、g is achieved with a double insulated plastic case, double insulated test lead connectors, a one second delayed start test button, high voltage warning symbols , flash on the display, and the test terminal HV warning light flashes. A socket in the side recess panel provides a 5 volt logic signal to

20、drive an external warning light. Capacitive loads are automatically discharged at the end of a test. Beneath the display, four tactile keys normally control:- - Electrical noise Filter - Contrast - Back-light. General Description 4 RS232 connection Download Real time or Batch results to PC. Remote o

21、peration. 12 V d.c. connection Plug in supply of 10 - 15 V to charge the battery Battery Charge Indicator Mains connection Plug in supply of 95 - 265 V a.c. to charge the battery. Fuse 200 mA - 250 V HV On indicator connection 5 V logic signa output. (To connect an external HV indicator) Side recess

22、 Panel Features and Controls Power On / Off Switch Press to turn On / Off. Left Hand Cursor keys Press to:- i) Select and highlight the required mode. ii)Select test Results / exit the screen; return back to the screen and then set the code back to ON. 5. Press the END key to exit back to the Menu s

23、creen. 6. Switch the instrument Off, pause, and then switch back On again. The ENTER THE SECURITY CODE input screen is displayed. 7. Enter (and remember) the new 3 digit security code using the +, -and NEXT keys. On completion, press the OKkey. The instrument powers up and the Menu screen is display

24、ed. Setting Up Procedures 10 11 Set / Reset Setup Code To set or re-set the 3 digit Setup code, the code is switched from OFF to ON. The screen is then exited and on re-entry, the required user definable 3 digit code is entered. This Setup code must then be entered by anyone wishing to access the Se

25、tup screens. 1.From the Menu screen, use the left hand cursor keys to select and highlight SETUP. 2. Press the CHANGEkey. The SETUP screen is displayed. 3. Press the NEXT key. The SETUP MODE screen is displayed. 4. Use the left hand cursor keys to select and highlight SETUP SECURITY CODE. 5. Press t

26、he CHANGEkey to set the code to ON (or OFF). If an exisiting code is to be changed, set the code to OFF; exit the screen; return back to the screen and then set the code back to ON. 6. Press the ENDkey to exit back to the Menu screen. 7.Highlight SETUP, and press the CHANGEkey. The ENTER THE SECURIT

27、Y CODE screen is displayed. 8.Enter (and remember) the new 3 digit security code using the +, -and NEXT keys. 9.Press the ENDkey to return back to the Menu screen. Note:- Persons with access to the Setup mode will also be able to access (and control) the Power On code. Set / Reset Date Format Date f

28、ormat can be selected as DD / MM / YY - YY / MM / DD - MM / DD / YY. Note that changes to the Date format will only be shown in subsequent test data. 1.From the Menu screen, use the left hand cursor keys to select and highlight SETUP. 2. Press the CHANGEkey. The SETUP screen is displayed. 3. Press t

29、he NEXTkey. The SETUP MODE screen is displayed. 4. Use the left hand cursor keys to select and highlight DATE FORMAT. 5. Press the CHANGEkey to select the appropriate sequence for Day (DD) Month (MM) and Year (YY). 6. Press the ENDkey to return back to the Menu screen. Set / Reset Current limit 1. F

30、rom the Menu screen, use the left hand cursor keys to select and highlight SETUP. 2. Press the CHANGEkey. The SETUP screen is displayed. 3. Press the NEXTkey. The SETUP MODE screen is displayed. 4.Use the left hand cursor keys to select and highlight CURRENT LIMIT. 5. Press the CHANGEkey to select 2

31、 mA or 5 mA. 6. Press the ENDkey to return back to the Menu screen. Set / Reset Data Output Rate - for Real time output 1. From the Menu screen, use the left hand cursor keys to select and highlight SETUP. 2. Press the CHANGEkey. The SETUP screen is displayed. 3. Press the NEXTkey. 4. Press the NEXT

32、key again. DATA OUTPUT EVERY. is displayed. 5. Press the Changekey. The + and - controls are displayed. 6. Using the + and -keys, adjust the Data Rate as required. Maximum = 1 second, Minimum = 60 seconds 7. Press the OKkey. 8. Press the ENDkey to return back to the Menu screen. 12 Set / Reset Locki

33、ng Test button The red Test button defaults to locking, when pushed for more than 1 second. The button can be set to Locked or Unlocked. 1.From the Menu screen, use the left hand cursor keys to select and highlight SETUP. 2. Press the CHANGEkey. The SETUP screen is displayed. 3.Press the NEXTkey. 4.

34、Press the NEXTkey again. 5.Use the left hand cursor keys to select and highlight TEST BUTTON. 6. Press the Changekey to select LOCKING, or NOT LOCKING, as required. Note:- If NOT LOCKING is selected,Fault Conditioning - (BURN) mode is not available. 7. Press the OKkey. 8. Press the ENDkey to return

35、back to the Menu screen. Testing Precautions The S1-5010 can generate up to 5 mA at 5000 V. Circuit connections must not be touched when testing. When turned On, voltage in excess of 5 volts across the + and - terminals will be indicated on the display. The voltage indicator and automatic discharge

36、features of the S1-5010 should be regarded as additional safety features and not a substitute for normal safe working practice. When carrying out prolonged unattended tests, care should be taken ensure that harm or damage cannot be caused. When using theBURN feature, care must be taken that no harm

37、or damage can be caused. The test terminal area and side recess panel recess must be kept in a dry, clean condition. If any part of the instrument is damaged, it should not be used, but returned to the manufacturer or an approved repair company. Fuse replacement must be of the correct type and ratin

38、g. See Specification. Should the plug on the power cord not be the type for your socket outlets (receptacles), do not use an adaptor. Use a suitable alternative power cord. Wires in power cords are coloured as follows: -U.K / InternationalU.S.A. Earth (GroundYellow/Green Green NeutralBlueWhite Phase

39、 (Line) Brown Black If using a fused plug, a 3 Amp fuse to BS1362 should be fitted. Operation 13 The circuit under test must be completely de-energized and isolated before test connections are made Working with Capacitive Loads Charged Circuit Discharge Capacitive circuits charged to several kV can

40、be lethal. Circuits must be discharged before handling and connecting the test leads, and similarly before disconnecting the test leads. At the end of a test, any external capacitance is discharged automatically and the warning devices will continue to indicate until the terminals are in a safe cond

41、ition. While the instrument design incorporates maximum safety, safe working practice should assume that the instrument discharge circuit and warning devices could fail, and a shorting link should be connected across capacitive loads before handling them *Automatic discharge must not be relied upon

42、as an alternative to normal safe working practice. *Care must be taken to prevent capacitive circuits becoming disconnected during a test, leaving the circuit in a charged state. Dielectric Absorption Some capacitive items exhibit an effect called Dielectric Absorption. The dielectric can absorb cha

43、rge during the test. After the item is discharged, the absorbed charge is released back onto the capacitive plates effectively raising the voltage of the item, possibly to dangerous levels. Safe working practice dictates that tested items should be firmly shorted out with a shorting link, after disc

44、harge, until required for use Performing Tests - General Ensure that all test leads are clean and in good condition, and firmly connect them to the instrument and to the isolated circuit under test. Switch the instrument On by pressing the yellow On / Off switch once. The calibration check runs to c

45、heck the operation of the measurement system and correct any small calibration errors which may occur during the life of the instrument. The Menu screen is displayed on completion of the calibration check. If necessary, adjust the contrast setting using the .key. The key allows the back light to be

46、switched On or Off. (Switching the back light off, will conserve battery power by 10%). Select the required Test mode using the left hand cursor keys. Test time shown in the bottom right hand corner of the display indicates maximum test duration before it is stopped automatically. (Maximum test dura

47、tion is 90 minutes). Accept the default test time or use the right hand cursor keys to select and highlight the time indicator. Press the CHANGE key, followed by the + / -keys to set the required time. The required Test Voltage is selected with the right hand cursor keys. For specific types of test,

48、 pre-determined default voltages are set. For instance, the Step Voltage test only offers test voltage options of 2500 or 5000 volts. The VARI position gives the option to select a non- standard voltage between 25 and 5000 V d.c., or to continuously vary the voltage in 25 V steps during a test by us

49、ing the right hand cursor keys. Battery condition indication is given in the bottom left hand corner of the display. If the battery becomes completely exhausted the instrument will refuse to operate. Recharge the battery as soon as possible. If the battery is not recharged it could degrade to a state where it will not recharge. Note:- Test results and settings are protected by a backup battery so these will not be lost. To start a Test, press the red button for at least one second. Two bleeps are sounded and the F, flashing test terminal indicator light, a