1、English73 Series III Instruction Sheet. Panel 1 73 Series III Multimeter Instruction Sheet Read First: Safety Information W To avoid damage to the meter, electric shock or injury: Never use the meter if the meter or test leads look damaged. Be sure the test leads and rotary switch are in the correct

2、 position for the desired measurement. Never measure resistance in a circuit when power is applied. Never touch the probes to a voltage source when the test leads are plugged into the 10 A or 300 mA input jack. Never use the meter on circuits that exceed 4800 volt-amps. Never apply more than the rat

3、ed voltage between any input jack and earth ground. Be careful when working with voltages above 60 V dc or 30 V ac rms. Such voltages pose a shock hazard. Keep your fingers behind the finger guards on the test probes when making measurements. W Warning To avoid false readings, which could lead to po

4、ssible electric shock or personal injury, replace the battery as soon as the low battery indicator (M) appears. Symbols W Caution: Important Information. See instruction sheet. MAN Manual Range. T Double Insulation. M Low battery. Replace battery. CAT II Overvoltage Installation Category per IEC 610

5、10-1-95. CAT II instruments protect against transients from equipment supplied from the fixed installation, e.g., TV, PC, and household appliances. PN 1646063 February 2002 (English) 1997, 1998, 2002 Fluke Corporation. All rights reserved. Printed in China. RadioFans.CN 收音机爱 好者资料库 English73 Series I

6、II Instruction Sheet. Panel 2 Terminals 300 mA 10A FUSED 600V CAT V COM Milliamps Amps Volts, Ohms, Diode Test Common Terminal hr2f.eps See Specifications for overload protection. Pushbutton Use the pushbutton to either select a fixed range or put the meter in the Automatic Touch Hold mode. Autorang

7、e The meter defaults to autorange when first turned on. Manual Range Manual ranging is available in V ac, V dc, ohms, A ac, and A dc. The manual range mode and Touch Hold mode are mutually exclusive. MAN is displayed when the meter is in the manual range mode. Momentary + _ V MAN hr14f.eps To return

8、 to autorange, press R for 1 second or change the measurement function. RadioFans.CN 收音机爱 好者资料库 English73 Series III Instruction Sheet. Panel 3 Automatic Touch Hold Mode W Warning To avoid electric shock, do not use the Touch Hold mode to determine if a circuit with high voltage is dead. The Touch H

9、old mode will not capture unstable or noisy readings. The Touch Hold mode automatically captures and displays stable readings. Press R for 2 seconds. HOLD is displayed when the meter is in the Touch Hold mode. 2 seconds + _ V DC V DC _ + _ single beep VVV HOLDHOLD V DC HOLD hr3f.eps When the meter c

10、aptures a new input, it beeps and a new reading is displayed. Note Stray voltages can produce a new reading. To exit the Touch Hold mode, press R or change the measurement function. The Touch Hold mode and manual range mode are mutually exclusive. Bar Graph The bar graph shows readings relative to t

11、he full scale value of a displayed measurement range and indicates polarity. hr16f.eps RadioFans.CN 收音机爱 好者资料库 English73 Series III Instruction Sheet. Panel 4 Standby If the meter is on but is inactive for an hour (20 minutes in diode test), the screen goes blank and displays selected bar graph segm

12、ents. To resume operation, turn the rotary switch or press R. AC and DC Voltage (K L mL) + _ + _ V AC V DC + _ Volts ACVolts DCMillivolts DC V V V mV hr4f.eps Resistance (e) Turn off the power and discharge all capacitors. An external voltage across a component will give invalid resistance readings.

13、 + _ k hr6f.eps English73 Series III Instruction Sheet. Panel 5 Diode Test (G) Forward Bias Single Beep Reverse Bias Shorted Open or Good Diode Bad Diode + _ + _ Bad Diode + _ Good Diode + _ hr7f.eps English73 Series III Instruction Sheet. Panel 6 Continuity Test ( R ) + _ + _ hr5f.eps If continuity

14、 exists (resistance 210 ), the beeper sounds continuously. The meter beeps twice if it is in the Touch Hold mode. Current (? A) W Warning To avoid injury, do not attempt a current measurement if the open circuit voltage is above the rated voltage of the meter. To avoid blowing an input fuse, use the

15、 10 A jack until you are sure that the current is less than 300 mA. Turn off power to the circuit. Break the circuit. (For circuits of more than 10 amps, use a current clamp.) Put the meter in series with the circuit as shown and turn power on. DC + _ 1 4 3 2 VA hr8f.eps English73 Series III Instruc

16、tion Sheet. Panel 7 Holster The snap-on holster absorbs shocks and protects the meter and comes with a Flex-Stand. To protect the front of the meter, put the meter face down in the holster. hr15f.eps Maintenance W Warning To avoid electric shock, personal injury, or damage to the meter: Do not servi

17、ce this product other than as described in this Instruction Sheet unless you are a qualified technician and have the required equipment and service information. Remove any input signals prior to removing test leads and opening case. When servicing the meter, use only specified replacement parts. Do

18、not allow water to get in the case. W Caution To avoid damaging meter components, lift up the end of the battery as shown. To avoid contamination or static damage, do not touch the circuit board without proper static protection. For maintenance procedures not described in this Instruction Sheet, con

19、tact a Fluke Service Center. English73 Series III Instruction Sheet. Panel 8 Internal Fuse Test 300 mA 5-8 0.5OKOK 10 A OKOK hr10f.eps Battery and Fuse Replacement W Warning To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the lo

20、w battery indicator (M) appears. Note Before opening the case, make sure the test leads are removed and the rotary switch is turned to OFF. F1 F2 hr11f.eps English73 Series III Instruction Sheet. Panel 9 Cleaning To clean the meter, use a damp cloth and mild detergent; do not use abrasives or solven

21、ts on the meter. Contacting Fluke To contact Fluke, call: 1-888-99-FLUKE (1-888-993-5853) in U.S.A 1-800-36-FLUKE in Canada +31-402-678-200 in Europe +81-3-3434-0181 Japan +65-738-5655 Singapore +1-425-446-5500 from other countries Visit Flukes web site at: . Register your meter online at: . ItemDes

22、cription Part No.Qty. BT1Battery, 9 V, NEDA 1604/IEC 6F22 NEDA 1604A/IEC 6LR61 696534 614487 1 F1*Fuse, F630 mA, 250 V, Min Interrupt Rating 1500 A, IEC 127-1 7406701 F2*Fuse, F11 A, 1000 VAC/DC, Min Interrupt Rating 17 kA 8032931 * For safety, use exact replacement English73 Series III Instruction

23、Sheet. Panel 10 General Specifications Maximum Voltage Between any Terminal and Earth Ground 600 V DisplayDigital: 3,200 counts, updates 2.5/sec Analog: 31 segments, updates 25/sec Response Time of Digital Display V ac 2 s V dc 1 s 1 s to 320 k, 2s to 3.2 M, 10 s to 32 M Operating Temperature0C to 5

24、0C Storage Temperature-40C to 60C Temperature Coefficient0.1 x (specified accuracy) / C (28C) Electromagnetic Compatibility in RF field of 3 V/m on all functions except M Total accuracy = Specified accuracy plus +2.0 % of range for all functions except: 320.0 mV range: total accuracy = specified acc

25、uracy + 1.0 % of range 320.0 range: total accuracy = specified accuracy + 8 % of range Relative Humidity except 32 M Range: 32 M Range only: 0 % to 90 % (0 C to 35 C) 0 % to 70 % (35 C to 50 C) 0 % to 80 % (0 C to 35 C) 0 % to 70 % (35 C to 50 C) AltitudeOperating: 2000 meters Storage: 12,000 meters

26、 Battery Type9 V, NEDA 1604 or 6F22 or 006P, or NEDA 1604A or 6LR61 Battery Life2000 hrs typical with alkaline 1600 hrs typical with carbon zinc Continuity Beeper4096 Hz Shock, Vibrationper MIL-T-PRF 28800F Class III, Sinusoidal, Non Operating Size (H x W x L)2.8 cm x 7.5 cm x 16.6 cm (1.12 in x 2.9

27、5 in x 6.55 in) Weight340 g (12.0 oz) Safety600 V CAT II per ANSI/ISA S82.01- 1994, EN 61010-1: 1993, CSA C22.2 No 1010.1-92, UL 3111-1. EMC RegulationsEN 61326-1: 1997 Certifications/Listings English73 Series III Instruction Sheet. Panel 11 Accuracy Specifications Accuracy is specified for a period

28、 of one year after calibration, at 18 C to 28 C (64 F to 82 F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the RMS value of a sine wave input. Accuracy specifications are given as: ( % of reading + number of least significant digits ) Function

29、RangeAccuracy L3.200 V, 32.00 V, 320.0 V 600 V (0.3 %+1) (0.4 %+1) mL 320.0 mV (0.3 %+1) K (45 to 500 Hz, 3.2 V range. Other ranges 45 Hz to 1 kHz) 3.200 V, 32.00 V, 320.0 V, 600 V (2 %+2) (2 %+2) ?320.0 3200 , 32.00 k, 320.0 k, 3.200 M 32.00 M (0.5 %+2) (0.5 %+1) (0.5 %+1) (2 %+1) ? ?2.0 V (1% typi

30、cal) FunctionRangeAccuracy Typical Burden Voltage ? (45 Hz to 1 kHz) 32.00 mA, 320.0 mA 10.00 A * (2.5 %+2) (2.5 %+2) 6 mV/mA 50 mV/A A32.00 mA, 320.0 mA 10.00 A * (1.5 %+2) (1.5 %+2) 6 mV/mA 50 mV/A * 10 A continuous, 20 A overload for 30 seconds maximum. English73 Series III Instruction Sheet. Pan

31、el 12 Overload protection for all functions and ranges: 600 V. FunctionInput Impedance (Nominal) L, mL, K 10 M, 120 dB at dc, 50 Hz, or 60 Hz K60 dB dc to 60 Hz 60 dB at 50 Hz or 60 Hz Open Circuit Test Voltage Full Scale Voltage To 3.2 M32 M e3.1 V dc 2.8 V dc (typical) 440 mV dc 420 mV dc (typical) 1.4 V dc 1.3 V dc (typical) G R3.1 V dc2.0 V dc Typical Short Circuit Current e400 A G R500 A GVFTypical Test Current 0.0 V 0.6 V 1.2 V 2.0 V 0.5 mA 0.4 mA 0.3 mA 0.1 mA