1、Phase Matrix, Inc. Instruments You Can Count On Phase Matrix, Inc. EIP 575B and 578B CW Frequency Counters Source Locking CW Microwave Frequency Counters with Selective Power Measurement Source Locking Frequency Range of 10 MHz to 20/26.5 GHz (110 GHz optional) Resolution to 10 kHz 200 msec phase-lo
2、ck time Keyboard controlled frequency limit selection Power measurement accuracy to 0.5dB typical -30 dBm sensitivity 200 Watt (+53 dBm) peak damage protection 200msec acquistion time 20 Mhz P-P FM tolerance up to a 10 MHz rate Page 1 575B 578B RadioFans.CN 收音机爱 好者资料库 Phase Matrix / EIP 575B and 578
3、B. . . . Source Locking Microwave Frequency Counters The Ideal Research Counters This family of Phase Matrix/EIP microwave frequency counters provides fully automatic source locking of virtually any electronically tunable source to the same accuracy and long term stability as the timebase oscillator
4、 in the counter. The ability of the 575B and the 578B to accurately set and stabilize the frequency of a source generator often eliminates the need for an expensive, synthesized signal generator. The 575B measures CW, FM and AM frequencies from 10 Hz to 20 GHz, and the 578B extends that range up to
5、26.5 GHz. With simultaneous power measurement capability, and options for a high stability time base, these high performance counters are ideally suited for applications in: Production Line testing R only Phase Matrix counters feature a YIG-preselected microwave input, which provides unparralled bur
6、nout protection, FM tolerance and frequency selectivity. The YIG preselector works like a tunable bandpass filter, preventing harmonics and other out-of-band spurious signals from interfering with measurement of the desired signal. It also protects the counter from accidental application of high lev
7、el signals (up to 200 watts peak), reducing downtime and the associated high cost of repairing damaged microwave circuitry. Selective Frequency and Power Measurements With a single connection, the 575B and 578B can simultaneously measure and display the input signals frequency and power level in the
8、 microwave band, eliminating the need for a seperate microwave power meter. Within the 25MHz bandwidth of the YIG-preselector, only the selected signals frequency and power level are measured. Signals to be analyzed are selected by keystroke entry of an individual center frequency, or search a range
9、 between a low and high frquency limit. This signal selectivity, combined with 20MHz of FM tolerance at all rates up to 10MHz, allows the 575B and the 578B to make accurate frequency and power level measurements even while the input signal is carrying traffic. Frequency Extension to 110 GHz Option 0
10、6 provides the ability to extend the frequency range of your 578B, in bands, up to 110 GHz. Remote sensors allow you to reach out to connect to virtually any wave guide system without the complications of the additional plumbing necessary to bring the signal to your counter. A wide selection of sens
11、ors provides measurement capability in the wave guide band that you are working in now, and the flexibility to change as your application changes without having to purchase another counter. Only Phase Matrix counters offer the unique YIG-preselected heterodyne technique. Page 2 YIG Filter RF Input 9
12、50MHz to BW=25MHz MIXER IF to Count Circuitry SRD L.O. All Phase Matrix Counters feature the unique YIG Preselected Heterodyne Down-Convertor. The frequency selective operation of the counters allows measurement of any individual signals frquency and power in a multi-signal environment. POWER (dBm)
13、FREQUENCY 0 +10 -5 -30 MEASURED SIGNAL RadioFans.CN 收音机爱 好者资料库 Page 3 Phase Matrix / EIP 575B and 578B. . . . The Ultimate Reasearch Instrument Automatic Broad-Band Tuning Operation of the source and counter combination is straightforward and automatic. Lock frequency is easily entered via the front
14、 panel keyboard or via standard GPIB interface. The counter automatically takes it from there, locking the source at the entered frequency. Frequency Storage and Recall For repetitive production testing, an operator can store up to nine lock frequencies and rapidly recall them as needed. This also r
15、educes typical lock times for steps over 10 MHz to300ms. Frequency Limits Automatic amplitude discrimination enables the 575B/578B counters to automatically select and measure the input signal with the highest level, and ignore all other harmonics and other spurious signals that are present. Frequen
16、cy Limits extend this signal selection capability by allowing you to select upper and lower limits, The counter will measure the frequency and power level of only the highest level signal within these limits - even if there are higher level signals present at the counters input. This gives you the a
17、bility to measure the frequency and power of a low level signal (such as a harmonic) even when a signal of much higher level (the fundamen- tal) is present. Power Measurement The 575B/578B family of microwave counters offers the optional ability to simulta- neously measure both the frequency and pow
18、er level through the same input. This often eliminates the need for a separate microwave power meter. With the 25 MHz bandwidth of the YIG tuned preselector, power measurement is made only of the displayed signal, not of its harmonics or other signals present. Thus you can simultaneously measure and
19、 display both frequency and power of individual signals in a multisignal environment. Easy keystroke entry of power offsets can be used to measure power deviation from a reference, or to compensate for losses in external hook-ups such as cable and attenuator losses. To FM (Phase-Lock) Input Microwav
20、e Signal Source or Sweeper Device Under Test Phase Matrix 575B/578B Counter Coupler or Splitter To External Sweep 0-100 Coarse Tune Input RF Output New Flexibility For GPIB-based ATE Systems The Phase Matrix 575B/578B family of counters offers new flexibility and efficiency in controller programming
21、 of your source. First, programming steps can be eliminated by letting the counter directly control the sources frequency over its entire frequency range. Second, only a single command string to the counter is needed to set and lock the source. Third, the signal source does not need to have GPIB cap
22、ability. The counter constantly monitors and corrects the source thereby relieving the controller of the task of checking the fre- quency and issuing correction commands. The ability to rapidly step and lock the signal source also saves test time as shown by these examples: Frequency StepTypical Loc
23、k Time 1 MHz200 ms 10 MHz300 ms 1 GHz500 ms Only three connections are required to coarse tune and then phase-lock an electrically tunable microwave signal source. The ability of the 575B and the 578B to accurately set and stabilize the frequency of a source generator often eliminates the need for a
24、n expensive, synthesized signal generator. RadioFans.CN 收音机爱 好者资料库 MODEL 575B and 578BBAND 1BAND 2BAND 3 Frequency Range Sensitivity Impedance Connector Input Coupling Maximum Operating Level Damage Level Acquisition Time Standard Center Frequency Mode Automatic Amplitude Discrimination FM Tolerance
25、 Maximum Tracking Speed VSWR Center Frequency Mode Frequency Limits 10 Hz-100 MHz 25mV rms 1M/20pF BNC (female) DC 120 V rms* 150 V rms* N/A N/A N/A Carrier remains in band Carrier remains in band N/A N/A N/A 10 MHz-1 GHz -20dBm 50 Ohms BNC (female) AC +10 dBm +27 dBm 800MHz/sec typical 2.5:1 typica
26、l N/A N/A 1-20 GHz (575B) 1-26.5 GHz (578B) -30 dBm 1-12.4 GHz -25 dBm 12.4 GHz-20 GHz -20 dBm 20 GHz-26.5 GHz (578B) 50 Ohms Precision Type N-female (575B) APC 3.5-female (578B) AC +10 dBm +45 dBm (30 watts) continuous +53 dBm (200 watts) peak pulsed (1uS PW, 0.1% duty) 200ms 800MHz/sec typical 2.5
27、:1 typical Keyboard controlled. Unit will measure signal within 5 MHz of entered frequency. Signals of equal amplitude must be seperated by 40 MHz Keyboard controlled. Unit will measure largest signal within set limits. Signals outside desired range must be seperated by 200 MHz (typical) from either
28、 limit. *Above 1KHz, decreases 6dB/octave down to 3.0 V rms SPECIFICATIONS Page 4 BAND 4 (option 06, 578B only) Frequency Range Sensitivity Connector Maximum Operating Level Damage Level Acquisition Time Amplitude Discrimination 26.5 GHz - 110 GHz -25 dBm typical Depends on remote sensor +5 dBm +10
29、dBm 1 second typical 10 dB Power Measurement Time Base: Standard TCXO Crystal Frequency Stability Output Frequency External Time Base GPIB (IEEE-488/1978) Programmabilty GPIB General Warranty Frequency Resolution Display Frequency Accuracy Test Sample Rate Reset Frequency Offset Frequency Multiply C
30、omputer Interface Certifications Operating Temperature Power Net Weight Shipping Weight Dimensions Standard Accessories Frequency Range Accuracy Resolution Minimum Level Display Offset Range Offset Resolution Offset Input Measurement Time Measurement Window 10 MHz Aging Rate Short Term Temperture Li
31、ne Variation 10 MHz square wave, 1V P-P min into 50 Requires 10 MHz, 1VP-P min into 300 Functions, special functions and diagnostics are programmable. Address settable from the front panel. Compatible IEEE STD-488. SH1, AH1, T5, L3, SR1, RL1, DC1 and DT1 implimented. 1-20 GHz (575B) 1-26.5 GHz (578B
32、) 1.2 dB typical (0 to 50C, input padded by 3 dB) 0.5 dB typical (25C, input padded by 3 dB) Power: 0.1 dB Frequency:100 kHz to 1 GHz (selectable) via GPIB 1 Hz to 1 GHz (selectable) via GPIB Equal to counter sensitivity Simultaneous frequency and power reading -99.9 dB to +99.9 dB 0.1 dB Keyboard o
33、r optional GPIB 1 Gate Time + 50ms + Freq Measurement Time 25 MHz nominal 1x10-7/month, 1x10-6/year 1x10-9 rms for one sec. averaging time 1x10-6, 0 to 50C 1x10-7, 10% line voltage 1 year Standard (Extendable to 3 years) Selectable 0.1 Hz to 10 MHz in band 1, 1 Hz to 1 GHz in bands 2 and 3. 12-digit
34、 LED sectionalized to read GHz, MHz, kHz, Hz or GHz, MHz, kHz, dBm. 1 count time base error. Front panel selected service diagnostics and user information. Varies time between measurements, from 0 sec to 10 sec. HOLD freezes display indefinitely. Resets display to zero and initiates new acquisition.
35、 Displayed frequency is offset by the entered value to 1 Hz resolution. Displayed frequency is multiplied by an entered integer from 1 to 99 and displayed to 1 kHz resolution. OFFSET is added or subtracted to obtain y = mx b result. GPIB (IEEE 488/1978) CE Certified for EMI/RFI to EN50011 and EN5008
36、2-1 Certified for Safety to IEC 1010-1 (1990) 0 to 50C. 100/120/140/200/220/240/VAC 10%, 50 to 400 Hz; 60 VA typical. 26 lbs. (11.8 kg). 32 lbs. (14.5 kg). 3.5” H x 16.75” W x 14.0” D (89 mm H x 425 mm W x 356 mm D). Power cord, Operating manual. SPECIFICATIONS Page 5 SPECIFICATIONS Page 6 Source Lo
37、cking Specifications Lock Time (typical) Output Drive (maximum) Capture Range Output Connector Phase Lock Spectrum Required Source Characteristics Frequency Range Resolution Accuracy Long Term Stability Polarity Bandwidth Coarse Tune Phase-Lock Recall Stored Data Coarse Tune Phase-Lock Coarse Tune P
38、hase-Lock External SweepBandwidth5Hz minimum Coarse Tune InputTuning Sensitivity10 MHz/V minimum 10 GHz/V maximum FM (Phase-Lock) InputBandwidth2 kHz minimum Tuning Sensitivity: Voltage Driven Input2 MHz/V min 1 GHz/V max Current Driven Input0.1 MHz/mA min 50 MHz/mA max Noise Floor vs. Input Frequen
39、cy The noise floor extends from the carrier to approximately the loop bandwidth. Beyond this, the noise floor decreases 12 dB/bandwidth octave. The noise floor is the greater of: 1) -70dBc/Hz or 2) (20log F) -65 dBc/Hz where F= Input frequency in GHz. 10 MHz-20 GHz (575B), 10 MHz-26.5 GHz (578B) 10
40、kHz (2.5 kHz 50 MHz) Equal to counters timebase Equal to counters timebase Automatically selected User selectable, 10 kHz, 2kHz, 500Hz, or counter automatically selects the widest bandwidth capable of locking. 50 msec + 1 counter acquisition time period for source bandwidths greater than 100 Hz; lim
41、ited by source tuning speed below 100 Hz. 200 ms 100 ms + 1 counter acquisition period (limited by source tuning speed.) 0 to +10V into 5K ohms min. 10V into 5K ohms min. for source gain constant 64 MHz/V. 75mA into 10K ohms max. for source gain constant 64 MHz/V. 4.5mA into 10K ohms max. for source
42、 gain constant 3.2 MHz/mA. Entire range of selected counter band, limited by the maximum output drive. Source gain constant multiplied by maximum output drive. Rear Panel BNC, female Rear Panel BNC, female Specifications and ordering information subject to change without notice. MODEL 575B MODEL 578
43、B OPTION 05 StabilityAging Rate Short Term Temperture Line Variation Retrace 5x10-10/day, (After 24 hour warm up). 1x10-10 rms for one sec. averaging time 3x10-8, 0 to 50C 2x10-10, 10% line voltage 5x10-9 of final value 10 minutes after counter is turned on at 25C ORDERING INFORMATION 10 Hz - 20 GHz
44、 Source Locking Microwave Frequency Counter 10 Hz - 26.5 GHz Source Locking Microwave Frequency Counter 01 02 05 06 09 10 14 15 010 020 031 032 040 Digital to Analog Converter Power Measurement High Stability Ovenized Time Base Frequency Extension Rear Panel Signal Input 24” Chasis Slides 2 Year War
45、ranty Extension (3 years total) MIL-STD 45662 (ANSI Z540-1:94) Transit Case Rack Mount Kit Extra Operating Manual (one supplied at no cost) Maintenance and Service Manual (includes operation information) Service Kit SPECIFICATIONS High Stability Ovenized Timebase Page 7 Options Accessories OPTION 01
46、 Option 01 will convert any three consecutively displayed digits to an analog voltage output. A display of 000 produces 0 volts output; 999 produces 0.999 volts full scale. Output is updated after every display update. Digital to Analog Converter OPTION 02 Option 02 measures power of signals applied
47、 to the Band 3 input. Power and frequency are simultaneously displayed to 0.1 dB and 100kHz resolution, respectively. Option 02 also allows power offsets from -99.99 to +99.99 dB (0.1 dB resolution) to be input from the keyboard or via GPIB. Power Measurement Frequency Extention Accessories 590 Freq
48、uency extention cable kit 091 26.5-40 GHz remote sensor, waveguide 092 40-60 GHz remote sensor, waveguide 093 60-90 GHz remote sensor, waveguide 094 90-110 GHz remote sensor, waveguide 095 50-75 GHz remote sensor, waveguide 096 33-50 GHz remote sensor, waveguide 097 26.5-50 GHz remote sensor, coax N
49、ote: All remote sensors require cable kit 590 and extended frequency Option 06 Specifications and ordering information subject to change without notice. For More Information Contact: Phase Matrix, Inc. 109 Bonaventura Dr. San Jose, CA. 95134 USA tel: 408-428-1000 fax: 408-428-1500 toll free: 877-4PhaseM Page 8 Datasheet Prepared By: Sonic Imagery Labs and PixelJam Productions Copyright 1999 Phase Matrix, Inc. All Rights Reserved Printed in the USA Revision 10/99 Phase Matrix, Inc 575B and 578B Source Locking CW Microwave Frequency Counters with