1、Manual Supplement 2008-2009 Fluke Corporation. All rights reserved. Printed in U.S.A. xx Manual Title: 5700A/5720A Series II Service Supplement Issue: 6 Print Date: November 2007 Issue Date: 7/09 Revision/Date: Page Count: 3 This supplement contains information necessary to ensure the accuracy of th

2、e above manual. This manual is distributed as an electronic manual on the following CD-ROM: CD Title: 5700A/5720A CD Rev. EN61010; CSA C22.2 No. 1010; ANSI/ISA S82.01- 1994 To: Safety.Complies with IEC61010-1, (2nd Edition), CAN/CSA-C22.2 No. 61010-1-04, and UL Std. No. 61010-1 (2nd Edition) Change

3、#3 On page 3-68, replace Table 3-37, with the following: 5700A/5720A Series II Output Load Resistors Frequency Measured Distortion Max. Distortion 2 V 100 ,1/8 W 10 Hz 0.054 % 20 Hz,1 kHz, 20 kHz, 50 kHz 0.039 % 100 kHz, 0.0405 % 200 kHz 0.3055 % 500 kHz 0.5055 % 20 V 1, W 10 Hz 0.0535 % 20 Hz, 20 k

4、Hz 0.0385 % 100 kHz 0.054 % 200 kHz, 500 kHz 0.304 % 200 V 10 K, 5 W 10 Hz, 20 Hz, 50 kHz 0.055 % 100 kHz 0.225 % 300 V 1 15 K, 5 W 40 Hz 0.1 % 300 V 1 15 K, 5 W 50 kHz 0.3 % 300 V 1 15 K, 5 W 70 kHz 0.4 % 1 The 5700A/5720A Series II maximum volt-Hertz product is (2.2 x 10 7). The 300V level assumes

5、 that a Fluke 5725A Amplifier is attached. Change #4 On page 3-39, replace step 1 with the following: 1. Connect the equipment as shown in Figure 3-15 and set the rear panel CALIBRATION 2. switch to the ENABLE position. RadioFans.CN 收音机爱 好者资料库 Manual Supplement 5700A/5720A Series II Service 2 7/09 C

6、hange #5 On page 5-9, Table 5-1 replace the F1 entry with the following: Reference Designator Description Fluke Stock No. Tot Qty Notes FUSE,.25X1.25, 1.5A,250V,SLOW (200V, 220V, 230V, 240V) 109231 1 F1 FUSE,.25X1.25, 3.0A,250V,SLOW (100V, 110V, 115V, 120V) 109280 1 Change #6, 50929 Replace page 1-3

7、5 with the following: AC Current Specifications 5720A Series II AC Current Specifications: 99 % Confidence Level Absolute Uncertainty 5 C from calibration temperature 1 Relative Uncertainty 1 C 24 Hours 90 Days 180 Days 1 Year 24 Hours 90 Days Range Resolution Frequency (Hz) (ppm output + nA) 220 A

8、1 nA 10 - 20 20 - 40 40 - 1 k 1k - 5 k 5k - 10 k 260 + 20 170 + 12 120 + 10 300 + 15 1000 + 80 280 + 20 180 + 12 130 + 10 320 + 15 1100 + 80 290 + 20 190 + 12 135 + 10 340 + 15 1200 + 80 300 + 20 200 + 12 140 + 10 350 + 15 1300 + 80 260 + 20 130 + 12 100 + 10 250 + 15 900 + 80 280 + 20 150 + 12 110

9、+ 10 280 + 15 1000 + 80 2.2 mA 10 nA 10 - 20 20 - 40 40 - 1 k 1k - 5 k 5k - 10 k 260 + 50 170 + 40 120 + 40 210 + 130 1000 + 800 280 + 50 180 + 40 130 + 40 220 + 130 1100 + 800 290 + 50 190 + 40 135 + 40 230 + 130 1200 + 800 300 + 50 200 + 40 140 + 40 240 + 130 1300 + 800 260 + 50 130 + 40 100 + 40

10、190 + 130 900 + 800 280 + 50 150 + 40 110 + 40 220 + 130 1000 + 800 22 mA 100 nA 10 - 20 20 - 40 40 - 1 k 1k - 5 k 5k - 10 k 260 + 500 170 + 400 120 + 400 210 + 700 1000 + 6000 280 + 500 180 + 400 130 + 400 220 + 700 1100 + 6000 290 + 500 190 + 400 135 + 400 230 + 700 1200 + 6000 300 + 500 200 + 400

11、 140 + 400 240 + 700 1300 + 6000 260 + 500 130 + 400 100 + 400 190 + 700 900 + 6000 280 + 500 150 + 400 110 + 400 220 + 700 1000 + 6000 (ppm output + A) 220 mA 1 A 10 - 20 20 - 40 40 - 1 k 1k - 5 k 5k - 10 k 260 + 5 170 + 4 120 + 3 210 + 4 1000 + 12 280 + 5 180 + 4 130 + 3 220 + 4 1100 + 12 290 + 5

12、190 + 4 135 + 3 230 + 4 1200 + 12 300 + 5 200 + 4 140 + 3 240 + 4 1300 + 12 260 + 5 130 + 4 100 + 3 190 + 4 900 + 12 280 + 5 150 + 4 110 + 3 220 + 4 1000 + 12 2.2 A 10 A 20 - 1 k 1 k - 5 k 5 k - 10 k 290 + 40 440 + 100 6000 + 200 300 + 40 460 + 100 7000 + 200 310 + 40 480 + 100 7500 + 200 320 + 40 5

13、00 + 100 8000 + 200 260 + 40 420 + 100 6000 + 200 280 + 40 440 + 100 7000 + 200 5725A Amplifier: 11 A 100 A 40 - 1 k 1 k - 5 k 5 k - 10 k 370 + 170 800 + 380 3000 + 750 400 + 170 850 + 380 3300 + 750 440 + 170 900 + 380 3500 + 750 460 + 170 950 + 380 3600 + 750 300 + 170 700 + 380 2800 + 750 330 + 1

14、70 800 + 380 3200 + 750 Note: Maximum output from the calibrators terminals is 2.2 A. Uncertainty specifications for 220 A and 2.2 mA ranges are increased by a factor of 1.3 plus 2 A when supplied through 5725A terminals. For the 5720A 220 A range, 1 kHz through 5 kHz and 5 kHz through 10 kHz, when

15、the output is coming from the AUX current terminal, use the 5700A Absolute Uncertainty Specifications. Specifications are otherwise identical for all output locations. 1. For fields strengths 0.4 V/m but 3 V/m, add 1 % of range. RadioFans.CN 收音机爱 好者资料库 5700A/5720A Series II Service Manual Supplement

16、 7/09 3 Replace page 1-36 with the following: 5720A Series II AC Current Specifications: 95% Confidence Level Absolute Uncertainty 5 C from calibration temperature 1 Relative Uncertainty 1 C 24 Hours 90 Days 180 Days 1 Year 24 Hours 90 Days Range Resolution Frequency (Hz) (ppm output + nA) 220 A 1 n

17、A 10 - 20 20 - 40 40 - 1 k 1k - 5 k 5k - 10 k 210 + 16 130 + 10 100 + 8 240 + 12 800 + 65 230 + 16 140 + 10 110 + 8 250 + 12 900 + 65 240 + 16 150 + 10 115 + 8 270 + 12 1000 + 65 250 + 16 160 + 10 120 + 8 280 + 12 1100 + 65 210 + 16 110 + 10 80 + 8 200 + 12 700 + 65 230 + 16 130 + 10 90 + 8 230 + 12

18、 800 + 65 2.2 mA 10 nA 10 - 20 20 - 40 40 - 1 k 1k - 5 k 5k - 10 k 210 + 40 130 + 35 100 + 35 170 + 110 800 + 650 230 + 40 140 + 35 110 + 35 180 + 110 900 + 650 240 + 40 150 + 35 115 + 35 190 + 110 1000 + 650 250 + 40 160 + 35 120 + 35 200 + 110 1100 + 650 210 + 40 110 + 35 80 + 35 160 + 110 700 + 6

19、50 230 + 40 130 + 35 90 + 35 170 + 110 800 + 650 22 mA 100 nA 10 - 20 20 - 40 40 - 1 k 1k - 5 k 5k - 10 k 210 + 400 130 + 350 100 + 350 170 + 550 800 + 5000 230 + 400 140 + 350 110 + 350 180 + 550 900 + 5000 240 + 400 150 + 350 115 + 350 190 + 550 1000 + 5000 250 + 400 160 + 350 120 + 350 200 + 550

20、1100 + 5000 210 + 400 110 + 350 80 + 350 160 + 550 700 + 5000 230 + 400 130 + 350 90 + 350 170 + 550 800 + 5000 (ppm output + A) 220 mA 1 A 10 - 20 20 - 40 40 - 1 k 1k - 5 k 5k - 10 k 210 + 4 130 + 3.5 100 + 2.5 170 + 3.5 800 + 10 230 + 4 140 + 3.5 110 + 2.5 180 + 3.5 900 + 10 240 + 4 150 + 3.5 115

21、+ 2.5 190 + 3.5 1000 + 10 250 + 4 160 + 3.5 120 + 2.5 200 + 3.5 1100 + 10 210 + 4 110 + 3.5 80 + 2.5 160 + 3.5 700 + 10 230 + 4 130 + 3.5 90 + 2.5 170 + 3.5 800 + 10 2.2 A 10 A 20 - 1 k 1 k - 5 k 5 k - 10 k 230 + 35 350 + 80 5000 + 160 240 + 35 390 + 80 6000 + 160 250 + 35 420 + 80 6500 + 160 260 +

22、35 450 + 80 7000 + 160 200 + 35 300 + 80 5000 + 160 230 + 35 350 + 80 6000 + 160 5725A Amplifier: 11 A 100 A 40 - 1 k 1 k - 5 k 5 k - 10 k 370 + 170 800 + 380 3000 + 750 400 + 170 850 + 380 3300 + 750 440 + 170 900 + 380 3500 + 750 460 + 170 950 + 380 3600 + 750 300 + 170 700 + 380 2800 + 750 330 +

23、170 800 + 38 3200 + 750 Note: Maximum output from the calibrators terminals is 2.2 A. Uncertainty specifications for 220 A and 2.2 mA ranges are increased by 1.3 plus 2 A when supplied through 5725A terminals. For the 5720A 220 A range, 1 kHz through 5 kHz and 5 kHz through 10 kHz, when the output is coming from the AUX current terminal, use the 5700A Absolute Uncertainty Specifications. Specifications are otherwise identical for all output locations. 1. For fields strengths 0.4 V/m but 3 V/m, add 1 % of range.