1、534 Main Street, Westbury, NY 11590 IET LABS, INC. in the GenRad T TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 Contents p. 2 Applic. pp. 4-8 Selection pp. 9-11 Products pp. 12-87 GenRad prod ucts pp. 50-87 Index p. 89 1 USES: Meters used for impedance measurements (inductance, capaci- tan

2、ce, and resistance) to characterize the performance of a variety of elec- trical components and materials. Test Resistors, Capacitors, Inductors or any type of passive component Testing Electronic Components Calibration Lab Features 0.02% Accuracy for RLC 0.0001 Accuracy for DQ mea- surements. Progr

3、ammable test voltages from 5mV to 1.275Vrms Up to 30 or 50 measurements per second respectively, with high speed option Wide range of measurement parameters IEEE-488 Bus and Component Handler Option Programmable test frequencies from 12Hz to 100kHz for maxi- mum testing versatility. A full, five-dig

4、it LED display for RLC ; four-digit readout for D and Q Digibridge 1689 1689M-Variable up to 50 measurements per second with high speed option, complements automatic handling equip- ment to maximize throughput. 2 selectable measurement modes: Continuous and Triggered with averaging available in each

5、 ensures measurement flexibility. Optional IEEE-488 Bus and Handler Interface enable remote programming and allow the addition of a component handler to optimize throughput. Wide choice of measurement parameters allow you to work with familiar units. A full, five-digit LED display for RLC measuremen

6、ts and a four-digit readout for D and Q testing, simultaneously dis- play both test results for each measurement, automatically. Guarded Kelvin measurement techniques protect measurement integrity. Automatic limit comparison and binning ensure fast, mistake-proof sorting of components. Fast and Accu

7、rate RLC Measurements RadioFans.CN 收音机爱 好者资料库 534 Main Street, Westbury, NY 11590 IET LABS, INC. in the GenRad T TEL: (516) 334-5959 (800) 899-8438 FAX: (516) 334-5988 Contents p. 2 Applic. pp. 4-8 Selection pp. 9-11 Products pp. 12-87 GenRad prod ucts pp. 50-87 Index p. 89 2 ORDERING INFORMATION SP

8、ECIFICATIONS Measurement Parameters: C/D, L/Q, R/Q, or C/R (series or parallel) Test Frequencies: Over 500 programmable test frequencies (12Hz to 100kHz) 0.01% Accuracy. Applied Voltage: 5mV to 1.275V (programmable in 5mV steps). Measurement Speed: Up to 30 measurements/second with High Speed Option

9、 (1689). Up to 50 measurements/second with High Speed Option. (1689M). Measurement Mode: Continuous or Triggered with averaging up to 256 measurements. Display Format: Dual Display featuring 5 full digit LED for RLC and 4 full digit LED for DQR Bin Number, Delta RLC, Delta %, Value Automatically pos

10、itioned decimal points and minus signs where appropriate. Individual LED indicators for parameters, units, and measurement conditions. GO/No GO Lights Bias: Internal 2.0VDC External up to 60VDC Automatic Functions: Auto ranging with manual hold Auto parameter (RLC) with manual selection Binning: Thi

11、rteen pass bins for RLC Two fail bins, RLC and DQR Interfaces: IEEE-488/Handler Interface option, High speed Measurement/IEEE-488/Handler Interface option Ranges: Extended Ranges Parameter Direct Reading Range Ratio and DQ in PPM R 0.00001 to 99999k 0.00010 to 9999.9G L 0.00001mH to 99999H 0.00010nH

12、 to 9999.9MH C 0.00001pF to 99999F 0.00010aF to 9999.9F R with C 0.0001 to 9999k not extended D with C 0.0001 to 9999 1 to 9999ppm Q with R or L 0.0001 to 9999 1 to 9999 ppm Accuracy: (Primary parameter) Basic RLC 0.02%. (Secondary parameter) Basic DQ 0.0001 Zeroing: Open and short circuit compensat

13、ion. General Features: Charged Capacitor Protection (1 Joule) DQ in PPM Keyboard Lock (Store Test Conditions) Bin Count Summary Constant Voltage Mode (25 source) Programmed Integration Time Programmed Delay (1 to 99999ms) Median Value Mode Test Fixture: 4-Terminal Kelvin 1689: Built-in 1689M: BNC Co

14、nnectors Temperature Effects (Typical): R,L or C 5ppm / C Q or D to 2ppm / C + (3ppm / C) x frequency in kHz. Dimensions: (w x h x d): 1689: 14.781 x 4.40 x 13.50in (375.4 x 111.8 x 342.9mm) (w x h x d): 1689M: 17.25 x 5.625 x 15.160in (438.15 x 142.87 x 385.2mm) Weight: 1689: 10 lbs. (4.5kg) net, 1

15、5.1lbs. (6.83kg) shipping. 1689M: 14 lbs. (6.41kg) net, 19.1lbs. (8.63kg) shipping. Accessories Supplied: Axial lead Adapters (1689 only) 1689-9602 BNC to BNC Extender Cable with Banana/Alligator Clips (1689M only) Power Cable Instruction Manual Calibration Certificate traceable to NIST Enviromental

16、: Operating: 0C to +50C Storage: -45C to +75C Humidity: 85% Power: 90 - 250V AC 50 or 60 Hz 60W max 1689-9700 1689 Precision RLC Digibridge 1689-9750 1689M Precision RLC Digibridge Includes: 4200-0300 AC Power Cable 1689-0120 Instruction Manual 1657-5995 Axial Lead Adaptors (1689 only) 1689-9602 BNC

17、 Extender Cable (1689M only) No P/N Calibration Certificate traceable to NIST Optional Accessories: 1689-9630 High Speed IEEE/Handler Interface 1658-9620 IEEE/Handler Interface 1689-9601 BNC Adapter 1689-9602 BNC to BNC Extender Cable* 1657-9600 Banana/Alligator Clip Extender Cable 1688-9600 874 Con

18、nector Extender Cable 1689-9600 Remote Test Fixture 7000-05 Chip Component Tweezers 1689-9605 GO/NO GO Remote Test Fixture 1689-9604 Calibration Kit 7000-03 Kelvin Clip Extender Cable 1689-9611 Rack Kit for 1689M only Digibridges 1689 & 1689M RLC Testers 1689 & 1689M RLC Testers p. 2 of 2 RadioFans.CN 收音机爱 好者资料库